• Title/Summary/Keyword: Test Installation

Search Result 1,493, Processing Time 0.032 seconds

Investigating the Effects of Teaching Based on an Analysis of High School Students' Knowledge State of Concepts Associated with Astronomical Observation (고등학교 천체관측 관련 개념의 지식상태 분석에 따른 교수-학습 효과)

  • Yoon, Ma-Byong
    • Journal of the Korean earth science society
    • /
    • v.32 no.7
    • /
    • pp.902-912
    • /
    • 2011
  • The purpose of this study was to investigate the effects of teaching based on analysis of a hierarchy of the concepts associated with astronomical observation as well as each learner's status of knowledge through analytical methods of the knowledge state. A test instrument was developed to measure high school students' concepts associated with astronomical observation before instruction. The learners' psychological hierarchy associated with astronomical observation that the participants possessed showed the order of 'motion of the earth${\rightarrow}$coordinate system${\rightarrow}$astronomical observation (mechanism of the telescope${\rightarrow}$installation of the telescope${\rightarrow}$observation through the telescope)', and so was the hierarchy of teaching (70.6%). The learners' knowledge state that is supposed to be similar each other in the ability of observing celestial bodies was different even through they scored the same on the concept test. There were cases with the knowledge state well-structured and not well-structured, which suggests that differentiated instruction with appropriate teaching-learning prescriptions be prepared. An analysis of the knowledge state can play the role of both preparing individualized learning prescriptions and formative evaluation. In the unit dealing with astronomical observation of Earth ScienceI, teaching according to the psychological hierarchy of learners rather than the order in which the textbook syllabi were presented scored significantly higher (p<0.05) on the level of concept achievements. This result suggests that the teacher can help students achieve more efficient in learning by analyzing the learner's knowledge state and reordering the syllabi of the textbook in teaching the concepts associated with astronomical observation.

Plans to Improve Safety Experience Education through the Experimental Analysis of Evacuation Equipment (피난기구 사용시간 실험분석을 통한 안전체험교육 개선방안)

  • Lee, Jeong Il;Lee, Sung Eun
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.35-42
    • /
    • 2019
  • The aim of this study is to investigate the direction of improvement of safety experience education through the analysis of the evacuation time experiment. For the study, test subjects were divided into groups of similar body size and weight. The test subjects were directly experienced four evacuation devices, and the experience time was measured. As a result of the analysis of the total time from the installation of the evacuation device to the escape, the time was measured in the order of Descending Life Line-Tilt-Down Rescue Line-Vertical Escape Chute-air safety mat. In the case of evaluating the evacuation time using evacuation mechanisms, the evacuation time was measured in the order of air safety mat-Tilt-Tilt-Down Rescue Line-Descending Life Line-Vertical Escape Chute. In the first and second experiments of the Descending Life Line, time differences were observed. The escape time using the Descending Life Line was reduced in the second experiment than in the first experiment. As shown in this result, education through experience has shown that behavioral confidence and time can be managed. The conclusion of this study is that the goal of safety education is to minimize human life and property damage. Therefore, in order to bring this effect to more people, it is necessary to make efforts to keep self-safe through experiential education.

Normal Operation Characteristics of 30kW Scale CVCF Inverter-Based Micro-grid System (30kW급 CVCF 인버터 기반의 Micro-grid의 정상상태 운용특성에 관한 연구)

  • Ferreira, Marito;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.662-671
    • /
    • 2020
  • Recently, for the purposes of reducing carbon dioxide(CO2) emissions in the island area, countermeasures to decrease the operation rate of diesel generator(DG) and to increase one of renewable energy sources(RES) is being studied. In particular, the demonstration and installation of stand-alone micro-grid(MG) system which is composed of DG, RES and energy storage system(ESS) has been implemented in some island areas such as Gapa-do, Gasa-do and Ulleung-do island. However, many power quality(PQ) problems may be occurred due to an intermittent output of RES including photovoltaic(PV) system and wind power(WP) system in a normal operating of constant voltage & constant frequency(CVCF) inverter-based MG system. Therefore, this paper presents a modeling of the 30kW scale MG system using PSCAD/EMTDC, and also implements a 30kW scale CVCF inverter-based MG system as test devices to analyze normal operating characteristics of MG system. From the simulation and test results, it is confirmed that the proposed methods are useful and practical tools to improve PQ problems such as under-voltage, over-voltage and unbalanced load in CVCF inverter-based MG system.

Reversed Lateral Load Tests on RC Frames Retrofitted with BRB and FRP (좌굴방지가새와 FRP로 보강된 RC골조의 반복 횡하중 실험)

  • Lee, Han-Seon;Lee, Kyung-Bo;Hwang, Seong-Jun;Cho, Chang-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.683-692
    • /
    • 2011
  • In piloti-type low-rise RC residential buildings, severe damages have been usually concentrated at piloti stories under the earthquake. In this study, a piloti story was retrofitted by installation of buckling-restrained braces (BRB's) to increase strength and stiffness of piloti story and by application of fiber reinforced polymer (FRP) sheet on columns to avoid the brittle shear and axial failure of columns. To verify this retrofit performance, reversed cyclic lateral load tests were performed on 1:5 scale bare and retrofitted frames. The test results showed that yield strength (43.2 kN) appeared to be significantly larger than design value (30 kN) due to the increase of strength in the compression side, but the stiffness value (11.6 kN/mm) turned out to be approximately one-half of the design value (24.2 kN/mm). The reasons for this difference in stiffness were due to slippage at joint between the frame and the BRB's, displacement and rotation at footing. The energy absorption capacity of the retrofitted frame was 7.5 times larger than that of the bare frame. The change of the number of load cells under the footing from 2 to 1 reduced lateral stiffness from 11.6 kN/mm to 6 kN/mm, which was only three times larger than that of the bare frame (2.1 kN/mm).

Cybertrap : Unknown Attack Detection System based on Virtual Honeynet (Cybertrap : 가상 허니넷 기반 신종공격 탐지시스템)

  • Kang, Dae-Kwon;Hyun, Mu-Yong;Kim, Chun-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.6
    • /
    • pp.863-871
    • /
    • 2013
  • Recently application of open protocols and external network linkage to the national critical infrastructure has been growing with the development of information and communication technologies. This trend could mean that the national critical infrastructure is exposed to cyber attacks and can be seriously jeopardized when it gets remotely operated or controlled by viruses, crackers, or cyber terrorists. In this paper virtual Honeynet model which can reduce installation and operation resource problems of Honeynet system is proposed. It maintains the merits of Honeynet system and adapts the virtualization technology. Also, virtual Honeynet model that can minimize operating cost is proposed with data analysis and collecting technique based on the verification of attack intention and focus-oriented analysis technique. With the proposed model, new type of attack detection system based on virtual Honeynet, that is Cybertrap, is designed and implemented with the host and data collecting technique based on the verification of attack intention and the network attack pattern visualization technique. To test proposed system we establish test-bed and evaluate the functionality and performance through series of experiments.

A Study on 8-Stage Loading Method of the Scaffolding Module for LNG Carriers (LNG 운반선 비계 모듈의 8단 탑재 방안 연구)

  • Shin, Sang-Hoon;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.78-85
    • /
    • 2020
  • The scaffolding system, which is a construction workbench of the cargo containment for a membrane LNG carrier, is a large truss structure composed of various members. To shorten the installation period and process of the scaffolding system, it is effective to enlarge the mounting unit from the existing two stages to eight stages. Owing to the increase in lifting load according to the large size of the module, the stresses around the pin and hole will be increased significantly. In this study, a tensile strength test and contact stress analysis were performed to confirm the structural safety. The relatively large hole deformation was observed visually near the average load generated in the vertical pipe at the top through tensile strength tests. A contact stress calculation confirmed the stress distribution around the hole. The contact problem was dealt with in terms of the Herzian contact stress. The possibility of 8-stage loading was examined by comparing the yield strength and contact stresses of failure critical locations. As a result, the 8-stage loading method of the existing scaffolding material was inadequate, and a new loading method with proper safety is proposed.

Development of a Shut-off Device of LP Gas Regulator for Home Use (가정용 LP가스 조정기 차단안전장치의 개발)

  • Kim Young-Gyu;Kim Pil-Jong;Kwon Boo-Kil;Park Gyo-Shik;Kim Ji-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.54-59
    • /
    • 2006
  • A safety device with shut-off function was developed for preventing intentional accidents that might happen by separating of cutting hoses connected to pressure regulators used in residential LP gas facility. For the verification of function and field adaptability, the safety device with shut-off function was tested in the state of joining the device to the regulator and a field test was carried out at home. This study shows that, at the inlet pressure of 0.07-1.56 MPa, the device shuts off the gas within the 5m length of hose regardless of the installation condition of the regulator. The shut-off flow rate increases in the order of perpendicular upward, horizontal and perpendicular downward. From the results of the field tests carried out at home for 5 months, there appears no problem using a gas range or a boiler. If the developed shut-off device is commercialized and distributed in the market the intentional accidents occurred by cutting or separating hoses can be prevented remarkably.

  • PDF

An Evaluation of Smeared Zone Due to Mandrel Penetration (맨드렐 관입에 기인하는 스미어 존의 평가)

  • 박영목
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.217-225
    • /
    • 2003
  • An experimental study was conducted to evaluate the smeared effect due to mandrel penetration into soft ground for a vertical drain installation. Laboratory tests were performed to investigate the formation of a smear zone, the variations of strength, and the consolidation characteristics in the disturbed zone using two types(CL at Yangsan site and OH at Pohang site) of soft clayey soils. The smear zone effect was evaluated focusing on mandrel shape, mandrel size, penetration speed, and ground condition. Based on laboratory test results, the diameter of the smear zone$(d_s)$ ranged from 3.08 and 3.92 times that of mandrel$(d_m)$. It was also found that the $(d_s/d_m)$ value of the circular shape of the mandrel is smaller than those of square and rectangular shapes. The value of $(d_s/d_m)$ decreased with larger mandrel size, lower penetration speed in the CL soil, and higher penetration speed in the OH soil. However, natural water content was minimally affected by $(d_s/d_m)$. Respectively, the coefficients of horizontal consolidation$(C_{hs})$ and horizontal Permeability$(K_s)$ of smear zone ranged from 0.81 to 0.87 times, and 0.73 to 0.83 times those of the undisturbed zone. Based on this study, the values of $C_{hs}, K_s$ and unconfined compressive strength$(q_{us})$ in the smear zone were the lowest at close vicinity of the mandrel and increased linearly with distance from the mandrel. Further, the $(q_{us})$ varied from 0.5 to 0.9 times that of the undisturbed zone strength.

Verification of Practicality for the SSBL and Pinger Synchronizing Biotelemetry Method and System through the Tracking of Fish (어류의 행동추적에 의한 SSBL · 핑거동기 바이오텔레메터리 방식과 시스템의 실용성 검증)

  • Park, Ju-Sam
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.1
    • /
    • pp.78-85
    • /
    • 2004
  • The new biotelemetry method and system that the installation and the treatment of equipment is convenient and the instantaneously detailed position of the fish attached a pinger is able to track comparatively easily had been developed, an practicality of it were verified in the water tank and the small sea port through the tracking of fish. The biotelemetry method had been gotten the three dimensional locations of fish to the receiving transducer by combining of the super short base line (SSBL) method to detect the direction of pinger and the pinger synchronizing method to measure the range from receiving transducer to pinger. The receiving system had been designed to realize the high precision or wide detection range by application of the basic design method for receiving system of biotelemetry and the hydrophone array configuration. From tracking test of carp in the water tank, the migration course and the velocity of carp was investigated and the observed migration course was compared with measurement. The measured migration course of carp coincided with the observation in the main and the position of carp was able to track three dimensionally. The velocity of carp measured by the moving average method was 11.2cm/s. From tracking test of yellowtail in the small sea port, the migration course and the velocity of yellowtail was investigated at natural condition. The position of yellowtail was able to track three dimensionally and the velocity of it measured by moving average method was 43.9cm/s.

Estimation on Discharge Capacity of Prefabricated Vortical Drains Considering Influence Factors (영향인자를 고려한 연직배수재의 통수능 평가)

  • Shin Eun-Chul;Park Jeong-Jun;Kim Jong-In
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.9
    • /
    • pp.13-23
    • /
    • 2005
  • The prefabricated vertical drains (PVDs) are one of the most widely used techniques to accelerate the consolidation of soft clay deposits and dredged soil. Discharge capacity is one of the factors affecting the behavior of PVDs. In the field, a PVD is confined by clay or dredged soil, which is normally remolded during PVD installation. Under field conditions, soil particles may enter the PVD drainage channels, and the consolidation settlement of the improved subsoil may cause 131ding of the PVD. These factors will affect the discharge capacity of the PVDs. In this study an experimental study was carried out to estimate the discharge capacity of three different types of PVDs by utilizing the large-scale laboratory model testing and small-scale laboratory model testing equipments. The several factors such as confinement condition (confined by soft marine clay or dredged soil) and variations of the discharge capacity were studied with time under soil specimen confinement, The test results indicated that discharge capacity decreases with increasing load, time, and hydraulic gradient. With load application, the cross-sectional area of the drainage channel of PVD decreases because the filter of PVD is pressed into the core. The discharge capacity of the soft marine clay-confined PVDs is much lower than that of the dredged soil-confined PVDs.