• Title/Summary/Keyword: Test Installation

Search Result 1,495, Processing Time 0.026 seconds

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

Remote Communication of sensor data in Ballast Water Treatment System (선박 평형수 처리 시스템에서 센서 데이터의 원격 통신)

  • Kim, Chin-Hoon;Kim, Joo-Man;Kim, Byoung-Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.139-147
    • /
    • 2014
  • The ballast water may be discharged into another sea area with marine organisms, it caused problems to disturb the marine ecosystem. So, in order to remove these environmental risk factors, the IMO has mandated the installation of BWTS to the all ships. Our monitoring system diagnose and predict a failure of BWTS by analyzing the sensor information of BWTS collected from which the ships scattered in the ocean of several. This paper presents the design and implementation of communication modules for BWTS remote monitoring considering the satellite communication charge fee. In the our study, we implemented the safety and cost-saving communication modules by LabVIEW program. The collected sensor informations is encrypted and compressed by LabVIEW modules running on RIO. Then they will be transfer to the land server and will be decrypt to enable monitoring in the land server. For the verification, we build the test modules which can verify from collecting the sensor data to consuming them in the monitoring server. We carried out 20 times for the data pattern in all of case. So, we verified the excellent functionality and reliability through the experimental result.

The performance evaluation of the polymer arm insulator for a compact transmission line tower (친환경적인 컴팩트 송전탑용 폴리머 절연암의 성능평가에 관한 연구)

  • Song, Hong-Jun;Park, Gi-Ho;Kim, Gwan-Hyung;Byun, Gi-Sik;Hwang, Yeong-Yeun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.341-347
    • /
    • 2009
  • As a right-of-way security for the high power transmission line tower construction is becoming more and more difficult, the friendly environmental compact tower design is required. For a proper insulation for the compact tower, the polymer material are being tried. Some countries has already adapted, in the various polymer application and management data, polymer arm insulator to the transmission tower, and shown a stable operation. However, in our country, the polymer arm insulator has left much to be desired in the installation on the transmission line tower. But polymer material has been developed by high strength and technology and is expected to be used in various electric equipments. The polymer arm insulator is a one of good electric insulation materials to expand the power supply capacity in the rapid power demand increasement In this research, the new polymer am insulator is designed and its electric specifications are analyzed. Its mechanical specifications is verified through the field test on the compact tower which is modified by the polymer arm insulator.

Study on characteristics of noncontact vibrating displacement sensor (비접촉식 진동 변위센서의 특성에 관한 연구)

  • Cho, C.W.;Cho, S.T.;Yang, K.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2011
  • This thesis is about the result of conducting a specific experiment for the development of noncontact vibration displacement sensor for measuring the spindle vibration that is used for conditional monitoring of machinery. One should be careful when using the eddy current type displacement sensor because the sensitivity of it is different according to the quality of the material. While the probe used for nondestructive inspection adopts the effect of transmitting the material by using the high frequency domain, the eddy current type displacement sensor uses the lower frequency of around 1MHz. Also, while the nondestructive probe uses the method of enhancing output by using the resonance zone, the vibration displacement sensor utilizes the stable zone by avoiding the resonance zone. Since the oscillator of the converter uses the "L" element as Probe, its characteristic changes with the variation of a relevant impedance. In other words, if the length of Probe's Cable gets extended (Impedance increase), the sensitivity declines accordingly. The effect of surrounding temperature was small, but the influence of the quality of Sensor Coil used was high. Moreover, following an experimental demonstration of the phenomenon where the sensitivity decreases as the frequency of the tested material increases from a frequency response test, the maximum frequency that could be measured was approximately 1KHz. It was noted that the degree of precision could be maintained by using the gap of the probe in the linear zone at the installation site.

Evaluation of Drain Capacity in Tunnel Drainage System using Drainboard (바닥배수판을 이용한 터널 배수시스템의 통수능 평가)

  • Bae, Gyu-Jin;Lee, Gyu-Phil;Lee, Sung-Won;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.1
    • /
    • pp.13-20
    • /
    • 2006
  • This study proposes a new concept of a tunnel central drainage system by using a drain board to make a breakthrough on difficulties in the installation of conventional drainage system and draw-down of its drain capacity especially in long tunnels. A fundamental study has been performed for evaluation of the drain capacity of the planar drainage system adopted in this study. In fact, the system proposed makes possible to omit the side, transverse as well as central drainage pipes required in the conventional system, even if its drain capacity and any guideline for design are not available to date. In this circumstance, it is carried out to investigate the correlation between drain capacities and, shapes and posit ions of the columns of the drain board in terms of a variety of water inflows through hydrological model tests. It is shown from the tests that a drain capacity is highly influenced by the shape and the distance between the columns of a drain board in flowing direction, and a round rectangular shape of the columns leads to the highest capacity of drainage. And also, the shorter distance between the columns in flowing direction, the higher drain capacity would be achieved.

  • PDF

Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling (로봇 냉각을 위한 수냉식 냉각판의 성능 평가)

  • Lee, Suk-Won;Karng, Sarng-Woo;Hwang, Kyu-Dae;Kim, Seo-Young;Rhee, Gwang-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.189-196
    • /
    • 2008
  • The increase of system weight due to installation of cooling devices adds electrical and mechanical loads of humanoid robot, and in return, results in much heat. Therefore, the weight of cooling system is a critical issue for robot cooling. In this study, we propose non-metallic cold plates to deal with such problems. We compare thermal performances between one metallic cold plate and five different types of non-metallic cold plates. A metallic cold plate is totally made of copper. Five non-metallic PC(polycarbonate) cold plates, which are designed to reduce the overall weight of robot cooling system, are composed of a polycarbonate cover with different types of base plate. The overall heat transfer coefficients per unit mass and thermal resistances are obtained for the cold plates. The metallic cold plate shows the best thermal performance. It is interesting to note that the PC cold plate with an aluminum base plate with 18 channels shows the best overall heat transfer coefficient per unit mass. Most polycarbonate cold plates display fairly comparable thermal performance with more reduced system weight compared to the metallic cold plate.

A Study on the User-driven Urban Park Development Plan Awareness Survey - Focusing on Lawns·Grass Area - (의식조사를 통한 이용자 중심의 도시공원 조성방안 연구 - 잔디·녹지공간을 중심으로 -)

  • Seo, Jung-Young;Sung, Hyun-Chan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.61-72
    • /
    • 2009
  • This study aims to analyze the current situation of and issues in the structure of urban neighborhood parks and park facility installation in cities in Gyeonggi-do. Then, based on its findings, plans to improve the space structure of the parks were examined and suggested to raise the city environment improvement function and green area base function of urban parks and fully satisfy users' needs for pleasant rest, recreation and cultural activities. The findings showed that, within parks, the area of grass where access was restricted reached about 24.4% in average. In other words, only 75.6% of total park area could be freely used by park visitors. As for an improvement plan, the grass area where access is limited may be converted into a gras area that can be freely used to raise the park use area, which currently stands only at 75.6%, to 100%. The result of cross analysis through Chi-Square Test regarding lawn use as well as regarding (dis)agreement with reduction of lawn, based on the investigation of cognition, showed a significant agreement of park users with reduction of green areas. Therefore it is considered that lawn space must be reduced according the result of the analysis, to set up plans for facility space that would meet the desires of users. The analysis of user behaviors revealed that many of them used square spaces and walks; therefore it is considered that re-structuring of space is necessary according to local characteristics. This study also made some policy suggestion. urban parks must be a base of city green areas to counter climate changes. When developing a park creation plan, a user demand survey must be conducted in advance. In addition. grass construction methods should be improved to tolerate foot pressure.

A Study on PM10 Control in Subway Tunnels Using Natural Polysaccharide Dust Collecting Agent (천연 다당류 먼지포집제를 이용한 지하철 터널 내 PM10 제어에 대한 연구)

  • Lee, Han-Seob;Hwang, Su-Jin;Hwang, Hyun-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.122-129
    • /
    • 2017
  • Objectives: Most of the $PM_{10}$ in subway stations is spread by the train-induced wind from the tunnels. Therefore, in order to improve air quality in subway stations, it is important to remove the $PM_{10}$ from the tunnels. After the installation of PSD (platform screen doors), the influence of train-induced wind and $PM_{10}$ at the platform has decreased, but is estimated to have increased in subway tunnels. This study was conducted to investigate the control of $PM_{10}$ in subway tunnels by applying a 500-fold diluted solution mixed with a humectant using a natural polymer. Methods: For this purpose, we tested the dust reduction effect in a laboratory and corrosion test and water pollution using fish and aquatic plants for the natural dust collecting agent. In the tunnel of a subway station, we used the natural dust collecting agent over 15 days. The study was carried out on $PM_{10}$ control during operation, which accounts for more than 70% of subway dust. Results: As results, the natural dust collecting agent exhibited an excellent dust control effect, and it was safe for water quality and soil. It showed the effect of controlling $PM_{10}$ in the subway tunnel by 49.5- 64.7% over 15 days. The use of the dust collecting agent for the control of $PM_{10}$ could be confirmed in the subway. Conclusion: It is necessary to clearly explain the major portions of chemical components contained in $PM_{10}$ to figure out the characteristics of $PM_{10}$ and to develop effective reduction measures to decrease the adverse effects of $PM_{10}$ in the subway.

Case History Evaluation of Axial Behavior of Micropiles (소구경말뚝의 축방향 거동에 대한 사례 연구)

  • Jeon Sang-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.25-32
    • /
    • 2004
  • This paper examines the results of full-scale field tests on micropiles and side resistance is evaluated with respect to axial displacements and soil properties. Both cohesive and cohesionless soils are included in this evaluation. For all practical purposes, the developed load-displacement relationship and the geotechnical soil properties for each micropile and soil type can be used to represent the available data well through normalized average values and empirical correlations. There is a significant difference in load-carrying capacity between micropiles and drilled shafts that results primarily from the micropile pressure-grouting installation effects on the state of stress in the ground. The results show that micropiles can have a significant increase of capacity over larger-diameter drilled shafts at shallower depths with D/B < 100 or so. In cohesive soils, the typical increase is on the order of 1.5 with values as high as 2.5. For cohesionless soils, the typical increases are in the range of 1.5 to 2.5 with values as high as 6.

Case Studies on Ground Improvement by High Pressure Jet Grouting(II) Effect on the Ground Reinforcement and Cut off of Ground Water Behind Temporary Retaining Walls (고압분사주입공법에 의한 지반개량사례연구(II) -흙막이벽 배면지반보강 및 차수효과)

  • Yun, Jung-Man;Hong, Won-Pyo;Jeong, Hyeong-Yong
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.5-16
    • /
    • 1996
  • When braced excavation with temporary retaining wall installation, is performed in loose sand with high ground water level boiling may be induced and considerable damage on the excavation works and structures in the vicinity can take place. Recently, for the purpose of reinforcement of ground and cut-off of ground water behind the temporary retaining wall, high pressure jet grouting is widely used. The purpose of this paper is to investigate the effects of jet grouting on ground reinforcement and cut -off of the ground water behind temporary retaining walls for braced excavation. A series of both laboratory and field tests has been performed. The test results show that high pressure jet grouting has sufficient effects on reinforcement of stiffness of ground and retaining wall. The permeability of the improved ground was 10-f_ 10-3cm l s smaller than those of the original ground. Therefore, the effect on cut off of ground water behind temporary retaining walls could be improved by high pressure jet grouting method.

  • PDF