• Title/Summary/Keyword: Test Equipment

Search Result 3,390, Processing Time 0.036 seconds

Implementation of Impedance Matching Circuit for ATE (고속 ATE 시스템을 위한 임피던스 정합회로 구현)

  • Kim, Jong-Won;Seo, Yong-Bae;Lee, Yong-Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.4 s.17
    • /
    • pp.17-22
    • /
    • 2006
  • In the manufacturing processes of semiconductor, test process is important for quality of products. In the manufacturing process of dynamic memory, memory test is more important. So, automatic test equipment(ATE) is used necessarily. But, according to increase of speed of dynamic memory operation, the rapid test equipment is needed. Impedance matching between ATE and dynamic memory is expected to be an important problem for making a rapid test equipment over 1Gbps. According to increase of speed, inner impedance of ATE also works on important parameter for test. This paper is about the method that is for impedance matching of inner impedance and coaxial cable occurring in manufacturing of ATE. We proved effects of inner impedance by electric theory and verified the method of impedance matching using computer simulation.

  • PDF

Multi-body Dynamics and Structural Vibration Analyses of Smart UAV Ground Test Equipment (스마트 무인기 지상시험장치의 다물체 동역학 및 구조진동해석)

  • Park, Kang-Kyun;Kim, Dong-Hyun;Kim, Dong-Man;Choi, Hyun-Chul;Ahn, Oh-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.22-29
    • /
    • 2010
  • In this study, computational multi-body dynamics and structural vibration analyses including some impact condition have been conducted for the ground flight test system of the developed smart UAV model. Designed ground test system has four degree-of-freedom motions with limited motion control mechanism. Design safety margin designs for several structural components are tested and verified considering expected critical motions (pitching and rolling) of the test smart UAV model. Computational results for various analysis conditions are practically presented in detail. Futhermore, proper design modifications of the initially designed test equipment in order to guarantee or increase structural safety have been successfully conducted in the design stage.

Applicability Study of the Rapid Carbonation Test Equipment for Concrete (콘크리트 급속 촉진 탄산화 장비의 적용성 연구)

  • Choi, Young-Jun;Lee, Kwang-Myong;Kim, Joo-Hyung;Jung, Sang-Hwa;Lee, Myung-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.601-604
    • /
    • 2006
  • Reinforcement corrosion is the most important durability problem of reinforced concrete structures. One of the important factors affecting the steel corrosion is carbonation. However, existing carbonation test takes several months to obtain the results. Therefore, in this study, new rapid carbonation test equipment for concrete was developed and its applicability was investigated. The testing period can be reduced by increasing $CO_2$ concentration up to 100% in the equipment. It is found from the test results that the carbonation depth of concrete specimens tested for 2 weeks was $3{\sim}5$ times greater than that of specimens tested by existing test method. In conclusion, it would be possible to get the reliable test results enough to evaluate the durability of concrete structures in a short-period.

  • PDF

Improvement of Emissions from Diesel Engine according to the Korean Standard Test Cycle in the Construction Equipment (건설기계용 엔진의 국내 표준시험모드에 따른 배출가스 특성 및 개선)

  • Joo, Taeheun;Yu, Seunghun;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.4
    • /
    • pp.42-48
    • /
    • 2014
  • The emission standard of diesel engine on the construction equipment has been rapidly enhanced in advanced countries, because most of air pollutions was caused by construction equipment. So, all of the construction equipments will be tested for emission with standard measurement mode. But, the standard measurement mode of construction equipment is different for non-road and one for the road in korea. This study was conducted to measure emission characteristics of the construction equipment with changed standard measurement mode and to improvement the emissions experimentally.

Vibration Analysis of Inspection Equipment for a Semiconductor (반도체 검사 장비의 진동 분석)

  • Rim, Kyung-Hwa;An, Chae-Hun;Oh, Jung-Bae;Lee, Hyouk;Roh, Joon-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.569-574
    • /
    • 2008
  • Nowadays, the equipment for a semiconductor process is required to raise accuracy and productivity. Therefore, the natural frequency of the equipment has been lowered because it has been precise, rapid, large, and light. In order to improve the efficiency of production, it is necessary for the equipment to increase the operation speed, which causes inevitable vibration problems. In this paper, influence analysis of ball-screw in the equipment and evaluation method for the vibration on the base are presented based on the analyses of dynamic characteristics for the mechanical structure through the modal test.

  • PDF

Application of Reliability Growth Management for Construction Equipment Development Process (건설장비 개발과정에서 신뢰성성장관리 적용방법에 대한 연구)

  • So, Young-Kug;Jeon, Young-Rok;Ryu, Byeong-Jin
    • Journal of Applied Reliability
    • /
    • v.13 no.3
    • /
    • pp.175-190
    • /
    • 2013
  • This study considers reliability growth management as the excellent method for construction equipment development with the effect on decreasing COPQ(Cost of Poor Quality Cost) of new products. MIL-HDBK-189A(1981) and RADC-TR-84-20(1984) standards provide a general concept of reliability growth management including to reliability growth test, models and FRACAS(Failure Reporting and Corrective Action System). There is no study how to apply reliability growth management to construction equipment(or machine) development. This paper propose the method to apply it to construction equipment development process from the reliability target setting for developing products to launching them at market. It is expecially showing how to set target reliability for new developing equipment and the development risk to reach the reliability target in detail.

Design and Basic Performance Test of 4 Inch QC/DC Bellows for LNG Bunkering (LNG 벙커링용 4인치 QC/DC의 설계 및 기초 성능 실험)

  • Jang, Sung-Cheol;Seo, Chang-Myung;Kwen, Min-Soo;Eom, Jeong-Pil;Jung, Hyun-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.81-86
    • /
    • 2019
  • Although the localization rate of shipbuilding and marine equipment goods is set to be 70 percent by 2020, but the localization rate of equipment and materials for shipbuilding and marine facilities is currently 10 to 30 percent. For Korea's Big 3 shipbuilders, which build 70 percent of the world's largest shipbuilders, localization of shipbuilding equipment and equipment is an essential factor. In particular, there is a growing need to localize equipment and materials in terms of the number of lead standards and A/S. It is expected that there will be a rapid expansion of LNG carriers in the future, and it is necessary to develop equipment and equipment materials of LNG ships. In this study, the design and manufacture of LNG vessel equipment was conducted. Design and basic performance tests of 4-inch QCDC for LNG bunkering were conducted.

A Study for Development of Hydraulic Piston Pump for Driving Rescue Equipment (구난장치 구동용 유압 피스톤 펌프 개발에 관한 연구)

  • Lee, Jihwan;Lee, Kyongjun;Kim, Kyung Soo;Kang, Myeong Cheol;Lee, Hyun Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.255-263
    • /
    • 2018
  • This paper investigated design requirements for piston pumps, which were used as the power source of light rescue vehicle, and designed a piston pump satisfying such requirements. In order to satisfy the driving specification of the rescue device, the pump needs to be designed using the displacement volume of 110 cc/rev, the pressure of 350 bar and the rotation speed of 2,200 rev/min. The design was verified by flow and structural analyses respectively. The shape of the piston pump was optimized in terms of both flow characteristics and structural stability. A test equipment was also fabricated to verify the developed piston pump and test conditions were established. Finally, the developed piston pump was tested for its performance and operating temperature.

A Study on Fault History Management Equipment of Unmanned Aerial Systems (무인항공기 체계의 고장이력관리장비에 관한 연구)

  • Soh, Nahyun
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.3
    • /
    • pp.48-55
    • /
    • 2019
  • This paper presents a study on Fault History Management Equipment (FHME) of Unmanned Aerial Systems (UAS). UAS comprise of various types of electronic equipment for high reliability design for flight safety. Consequently, it is mandatory for each on-board equipment to have its own Built-In-Test (BIT) function, because rapid fault-detections for UAS are necessary. FHME is developed for the purposes of display, storage and management of such BIT results on ground. This paper describes the outline, development requirements, design and verification process of FHME.

Medical Clinics' quality Management of X-ray Units in Gyeongbuk Area (경북 지역 의원급의 X선 발생장치 정도관리 실태)

  • Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.267-275
    • /
    • 2010
  • Quality management of an x-ray unit drastically differs according to the type of establishment of medical institutions. Many primary medical institutions have it, but they do not pay much attention to quality management. In the study, Gyeongbuk area has been divided into four zones from January 4, 2010 to September 3, 2010, and four places were designated by city. Among medical institutions located at a total of 16 sites, the target was 8 places with X-ray emission equipment 10 years or more in use as well as 8 places with X-ray emission equipment less than 10 years in use. The 5 essential items of quality control were tested. In the test that checked for equipment it was found that sites with X-ray emission equipment 10 years or more in use didn't have ground connection (6.25%) while all of them passed the current leak test. In the exposure dose reproducibility test 4 sites with X-ray emission equipment 10 years or more in use (25%) and 1 site with X-ray emission equipment less than 10 years in use didn't pass the test. In the KVp accuracy test 5 sites with X-ray emission equipment 10 years or more in use (31.25%) and 2 sites with X-ray emission equipment less than 10 years in use (12.5%) didn't pass the test. In the tube current and tube current amount test 3 sites with X-ray emission equipment 10 years or more in use (18.75%) and 1 site with less than 10 years in use (6.25%) didn't pass the test. According to the findings of the present research, quality control at medical institutions with X-ray equipment 10 years or more in use was poorer than medical institutions with X-ray equipment less than 10 years in use. In this regard, administrative and technical measures need to be taken as soon as possible. In addition, owners of medical clinics or unit managers need to raise awareness, and it is necessary to revise a regular test cycle every year or every two years if they have old equipment or if the equipment is not used on a frequent basis. And it is also important to provide regular educational programs for quality management.