• 제목/요약/키워드: Tesla coil

검색결과 59건 처리시간 0.028초

개의 경막외 혈종의 자기공명영상학적 진단 (MAGNETIC RESONANCE IMAGING APPEARANCE OF EPIDURAL HEMATOMA IN DOG)

  • 최치봉;김휘율;김수관;배춘식
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권5호
    • /
    • pp.488-491
    • /
    • 2005
  • A 3-year-old female, 5kg, Shih-tzu developed an acute onset of depression, disorientation, hypersalivation, nystagmus after falling down 2 meter height place. In plain skull radiography, there was fracture line in the frontal and parietal bones and next day magnetic resonance imaging examination was performed. Magnetic resonance imaging of the brain was performed with 3.0 Tesla unit. Under general anesthesia, the dog was placed in prone with its head positioned in a birdcage coil. Transverse, sagittal and coronal fast spin echo images of the brain were obtained with the following pulse sequences: T1 weighted images (TR = 560 ms and TE = 18.6 ms) and T2 weighted images (TR = 3500 ms and TE = 80 ms). Magnetic resonance imaging showed epidural hematoma in the left frontal area resulting in compression of the adjacent brain parenchyma. Left lateral ventricle was compressed secondarily and the longitudinal fissure shifted to the right, representing mass effect. The lesion was iso-to slightly hyperintense on T1 weighted image and iso-slightly hypointense signal on T2 weighted image. At necropsy, there was a skull fracture and epidural hematoma in the left frontal area. Magnetic resonance imaging of epidural hematoma is reviewed.

고자장 MRI에서의 영상 영역에 대한 B1+ 균질성 (B1+ Homogenizaion over Whole Field of View in High Field MRI)

  • 김홍준;손혁우;조영기;유형석
    • 한국전자파학회논문지
    • /
    • 제23권1호
    • /
    • pp.96-100
    • /
    • 2012
  • 정 자장($B_0$)의 세기가 7 T(Tesla) 또는 9.4 T 고자기장 MRI(Magnetic Resonance Imaging) 시스템은 정 자장의 세기가 1.5 T 또는 3 T MRI(Magnetic Resonance Imaging) 시스템에 비하여 인가된 RF(Radio Frequency) 필드의 높은 불균질성을 보여준다. 다채널(multi-channel) RF 코일에서는 인가된 RF 자장($B_1^+$)의 불균질성을 개선시키기 위해서 각각의 코일 소자(element)에 인가되는 전류의 크기와 위상을 독립적으로 조절할 수 있다. 선택된 관심 영역에서의 RF 자장이 균일하도록 RF 코일의 각 요소로 들어가는 최적화된 전류의 크기와 위상 값을 얻기 위해서 iterative 방법과 함께 convex 최적화 방법이 사용된다. 이러한 방법을 입증하기 위하여 9.4 T MRI 시스템에 RF 코일의 공진 주파수가 400 MHz을 가지는 다채널 전송 선로 코일이 인체 두상 모형과 함께 모델링되었으며, 이 코일에 의하여 자장이 얻어진다. 9.4 T MRI 시스템을 위한 시뮬레이션 결과가 자세히 논의된다.

DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports (A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF

Superconducting Magnet Power Supply System for the KSTAR 2nd Plasma Experiment and Operation

  • Choi, Jae-Hoon;Lee, Dong-Keun;Kim, Chang-Hwan;Jin, Jong-Kook;Han, Sang-Hee;Kong, Jong-Dae;Hong, Seong-Lok;Kim, Yang-Su;Kwon, Myeun;Ahn, Hyun-Sik;Jang, Gye-Yong;Yun, Min-Seong;Seong, Dae-Kyung;Shin, Hyun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.326-330
    • /
    • 2013
  • The Korea Superconducting Tokamak Advanced Research (KSTAR) device is an advanced superconducting tokamak to establish scientific and technological bases for attractive fusion reactor. This device requires 3.5 Tesla of toroidal field (TF) for plasma confinement, and requires a strong poloidal flux swing to generate an inductive voltage to produce and sustain the tokamak plasma. KSTAR was originally designed to have 16 serially connected TF magnets for which the nominal current rating is 35.2 kA. KSTAR also has 7 pairs of poloidal field (PF) coils that are driven to 1 MA/sec for generation of the tokamak plasma according to the operation scenarios. The KSTAR Magnet Power Supply (MPS) was dedicated to the superconducting (SC) coil commissioning and $2^{nd}$ plasma experiment as a part of the system commissioning. This paper will describe key features of KSTAR MPS for the $2^{nd}$ plasma experiment, and will also report the engineering and commissioning results of the magnet power supplies.

68 cm 상온 보아를 갖는 MRI용 초전도마그네트에 관한 연구 (The Study on the Superconducting MRI Magnet of 68 cm in Room Temperature Bore)

  • 진흥범;오봉환;조전욱;오상수;권영길;하동우;이언용;김해종;김옥곤;최병주;류강식
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.142-146
    • /
    • 1996
  • In this paper, we present the main research results on the 2 Tesla class - superconducting MRI magnet which we have developed. Multi section type superconducting MRI main coil and various superconducting shims were designed and fabricated for obtaining the high field homogeneity, which is requested in the MR imaging. After assembling the magnet with room temperature bore cryostat field homogenity has been measured and analyzed by NMR field mapping system. According to this, field homogeneity of 22 ppm / 30 cm dsv was confirmed.

  • PDF

뇌척수액 미세순환을 통한 래트 내이 외림프의 가돌리늄 조영제 증강 특성 (Enhancement Characteristics of Gadolinium Contrast Agent in the Rat Inner Ear Perilymph through CSF microcirculation)

  • 김민정;이상열;이희중;이태관;장용민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권4호
    • /
    • pp.193-198
    • /
    • 2022
  • Contrast enhanced magnetic resonance imaging using gadolinium-based contrast agent (GBCA) is a very useful in vivo technique to visualize the inner ear pathology including endolymphatic hydrops. Although systemic intravenous (IV) administration can visualize the perilymph space, the visualization was possible by indirect passage of contrast agent through blood-perilymph barrier. All animal experimental procedures were performed under anesthesia with 5% isoflurane. Lipopolysaccharide (LPS) was instilled into the left tympanic cavity through the tympanic membrane using a sterile 27gauge needle to induce hydrops model. Tucker-Davis Technologies system was used to measure Auditory Brainstem Responses (ABRs). For intracerebroven-tricular (ICV) administration, 25 µmol of GADOVIST (Bayer, Berlin, Germany) was used and diluted GADOVIST injection was 10 µl. MR imaging was acquired with a 9.4 Tesla MRI scanner. Transmit-receive volume coil with 40 mm inner diameter and 75 mm out diameter was used. ICV administration well demonstrated the strong enhancement along the cerebrospinal fluid (CSF) microcirculation pathway including CSF fluid in the subarachnoid space and CSF space of the inner ear structures. On the other hand, IV administration showed no contrast enhancement along the CSF microcirculation pathway and showed weak enhancement in the inner ear structures. In case of rat hydrops model, ICV administration showed that the reduced contrast enhancement in the perilymph space of the hydrops induced inner ear compared to the contrast enhancement in the perilymph space of the normal inner ear. New systemic ICV administration method provide contrast enhancement of GBCA in the inner ear through CSF microcirculation pathway.

Human in-vivo 31P MR Spectroscopy of Benign and Malignant Breast Tumors

  • Jeong Mi Park;Jae Hyung Park
    • Korean Journal of Radiology
    • /
    • 제2권2호
    • /
    • pp.80-86
    • /
    • 2001
  • Objective: To assess the potential clinical utility of in-vivo 31P magnetic resonance spectroscopy (MRS) in patients with various malignant and benign breast lesions. Materials and Methods: Seventeen patients with untreated primary malignant breast lesions (group I), eight patients with untreated benign breast lesions (group II) and seven normal breasts (group III) were included in this study. In-vivo 31P MRS was performed using a 1.5 Tesla MR scanner. Because of the characteristics of the coil, the volume of the tumor had to exceed 12 cc (3×2×2 cm), with a superoinferior diameter at least 3 cm. Mean and standard deviations of each metabolite were calculated and metabolite ratios, such as PME/PCr, PDE/PCr, T-ATP/PCr and PCr/T-ATP were calculated and statistically analyzed. Results: Significant differences in PME were noted between groups I and III (p=0.0213), and between groups II and III (p=0.0213). The metabolite ratios which showed significant differences were PME/PCr (between groups II and III) (p=0.0201), PDE/PCr (between groups I and III, and between groups II and III) (p=0.0172), T-ATP/PCr (between groups II and III) (p=0.0287), and PCr/T-ATP (between groups II and III) (p=0.0287). There were no significant parameters between groups I and II. Conclusion: In-vivo 31P MRS is not helpful for establishing a differential diagnosis between benign and malignant breast lesions, at least with relatively large lesions greater than 3 cm in one or more dimensions.

  • PDF

FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle (Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI)

  • 한재복;최남길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.101-106
    • /
    • 2009
  • 본 연구는 FLASH 펄스파형을 이용하여 숙임각(flip angle ; FA)변화에 따른 T1 강조영상의 신호강도(signal intensity ; SI)와 대조도 대 잡음비(contrast to noise ratio ; CNR)를 비교함으로써 복부검사에서의 최적의 T1효과를 나타내기 위한 FA를 알아보고자 하였다. 2008년 9월부터 12월까지 본원을 내원하여 복부 MRI 검사를 시행한 환자 20명(남 : 12명, 여 : 8명, 연령 범위 : $28{\sim}63$세, 평균 : 51세)을 대상으로 하였다. 영상 장비는 3Tesla MR scanner(Magnetom Tim Trio, SIEMENS, Germany)였으며, 8 channel body array coil을 사용하였다. 사용된 영상변수는 FLASH 펄스파형과 TR : 120 ms, TE : minimum, FOV : $360{\times}300\;mm$, Matrix : $256{\times}224$, Slice : 6 mm, scan time : 15초로 Breath-hold 기법을 이용하였다. 복부 영상은 물 신호를 동시에 측정하기 위해 관심영역(FOV) 안에 물을 채운 50 ml syringe를 놓고 $10^{\circ}$부터 $90^{\circ}$까지 $10^{\circ}$ 간격으로 FA에 변화를 주면서 얻었다. 획득한 영상은 간(liver), syringe내부의 물(water), 비장(spleen), background의 신호강도(SI)와 대조도 대 잡음비(CNR)를 각각 측정하였으며 신호강도는 관심영역을 설정한 다음 각 부위에서 3번씩 측정하고 그 평균값을 구하였다. 영상 전체의 평가에서는 변이계수(coefficient of variation)를 적용하여 전체영상의 신호강도 균일도를 알아보았고 통계 분석은 SPSS for window version 17.0을 이용하였다. 간(liver)의 신호강도는 $475.54{\pm}81.76$으로 FA $40^{\circ}$에서 가장 높게 나타났으며 syringe내부의 물의 신호는 $475.97{\pm}68.98$로 FA $20^{\circ}$에서 가장 높았으며 FA가 높아짐에 따라 다른 조직의 신호보다 많은 감소를 보였다. 비장의 신호는 $443.02{\pm}55.77$로 FA $30^{\circ}$에서 가장 높은 신호강도를 보였으며 FA가 높아짐에 따라 신호가 감소하였다. 조직의 신호강도에서 Liver vs Water와 Liver vs Spleen은 FA $30^{\circ}$를 제외한 전 구간에서 통계적으로 유의한 차이를 보였고 Water vs Spleen은 FA $60^{\circ}$, FA $70^{\circ}$, FA $80^{\circ}$에서만 유의한 차이를 보였다(p < 0.01). 전체영상의 신호강도는 $175.42{\pm}57.93$으로 FA $10^{\circ}$에서 가장 낮게 나타났으며 FA가 높아짐에 따라 증가하다가 떨어지는 양상을 보였다. 또한 변이계수(coefficient of variation)는 FA $10^{\circ}$와 FA $20^{\circ}$에서 33.02와 31.43으로 가장 높게 나타났다. FA $10^{\circ}$와 FA $20^{\circ}$는 전체영상의 신호강도 균일도가 다소 떨어지는 영상으로 왜곡이 심하게 나타났다. CNR은 liver-water에서 FA $30^{\circ}$에서 12.73으로 가장 낮게 나타났고 FA $10^{\circ}$에서 -46.97, FA $80^{\circ}$에서 29.36으로 가장 높게 나타났다. liver-spleen의 CNR에서는 FA $10^{\circ}$에서 -3.18로 가장 낮게 나타났으며 FA $80^{\circ}$에서 9.65로 가장 높게 나타났다. 결론적으로 FLASH 펄스 파형을 사용한 복부 영상에서 최적의 T1효과를 나타내기 위해서는 FA $80^{\circ}$를 사용하는 것이 유용할 것으로 생각된다.

  • PDF

1-GFLOPS DSP를 이용한 자기공명영상 스펙트로미터 설계 (Design of MRI Spectrometer Using 1 Giga-FLOPS DSP)

  • 김휴정;고광혁;이상철;정민영;장경섭;이동훈;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권1호
    • /
    • pp.12-21
    • /
    • 2003
  • 목적 : 기존의 일반적인 스펙트로미터보다 향상된 성능을 가진 새로운 스펙트로미터를 설계 및 제작하였다. 대상 및 방법 : 초당 10억번의 부동 연산 능력을 갖춘 TMS320C6701 DSP를 이용하여 연속적으로 변하는 복잡한 경사자계파형을 실시간으로 계산하여 출력할 수 있고, 선택 단면을 interactive하게 조절할 수 있는 스펙트로미터를 설계, 제작하였다. 설계된 스펙트로미터는 DSP 기반의 디지털 제어부와 파형을 만들고 변조 및 복조를 수행하는 아날로그부로 구성되어 있다 RF 신호의 변조 및 복조는 디지털 기술을 사용하여 정밀도와 안정성을 높였다. 고속 병렬영상을 위하여 하나의 측정 보드당 4채널까지 측정할 수 있도록 하였고, 고속 DSP를 이용하여 빠른 재구성이 가능하도록 하였다. 결과 : 제작된 스펙트로미터를 1.5 테슬라 전신자기공명영상 시스템에 장착하여 다양한 방법으로 성능을 시험하였다. 디지털 변조/복조 방식에서 요하는 정밀한 위상 제어를 확인할 수 있었고, phase array 코일 영상을 통하여 다중 채널 측정시스템의 성능을 검증할 수 있었다. 개발된 스펙트로미터를 기존의 상품화된 스펙트로미터와 비교해 볼때 보다 정밀한 위상 제어가 가능한 것으로 나타났다. 결론 : Interactive하게 영상의 단면을 선택하고, 실시간 계산에 의한 파형출력은 나선주사 심장영상과 같은 첨단의 영상기법에 요구되는 스펙트로미터의 기능이다 또한 다채널 측정시스템도 병렬영상을 위한 필수적인 기능이다. 본 논문에서는 초당 10억번의 부동소수점 연산이 가능한 TMS320C6701 디지털신호처리기를 사용하여 이러한 기능들을 가진 스펙트로미터를 설계, 제작하였다. 디지털 방식의 변조/복조 기술을 채택하여 정밀한 위상제어가 가능하였다. 개발된 스펙트로미터를 FSE, GE, angiography 등 다양한 영상방법에 적용하여 성능을 확인하였으며, 기존의 제품보다 뛰어난 화질의 영상을 얻을 수 있었다.

  • PDF

초고해상도 미세영상 기법을 이용한 Mouse 뇌의 자기공명영상 연구 (High-Resolution MRI Study on Mouse Brain Using Micro-Imaging)

  • 한덕영;윤문현;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.142-147
    • /
    • 2008
  • 목적 : 본 연구는 핵자기공명 분광기를 개조한 미세영상 기법을 이용하여, 동물실험에 주류를 이루는 mouse를 대상으로, 0.1 mm 이내의 초고해상도 자기공명영상을 5분 정도 시간 안에 획득할 수 있는 방법을 개발하고자 하였다. 대상 및 방법 : 사용된 mouse는 C57BL/6로서 무게 50 그램 이내의 mouse를 사용하였다. 본 연구에 활용된 초전도 자석은 구경 89 mm, 4.7 T의 자기장 세기를 가진 수직형 자석이며, 사용된 샘플 코일의 직경은 30 mm 이고, 사용된 펄스시퀀스는 fast spin echo (FSE) 및 gradient echo (GE) 기법들이다. 결과 : 최적의 자기공명영상 파라미터를 확보하면서 2차원 영상으로서 수소밀도 및 T2 강조 영상을 획득하였다. 영상으로부터 mouse 뇌의 미세부분까지 상세히 해부학적 구조를 확인할 수 있었고, 또한 입체적인 정보를 획득하기 위하여 3D 영상도 부가적으로 획득하였다. 조영제를 이용한 dynamic contrast 연구에 3D 영상이 매우 유용하였다. 결론 : 본 연구를 통하여 mouse 뇌에 대한 고해상도 자기공명영상 획득을 위한 최적의 파라미터를 확보할 수 있었고, 또한 성공적인 자기공명영상도 획득하였다. 즉, 사람이나 다른 소동물뇌의 경우와 같이 mouse 뇌 조직의 다양한 부위의 미세부분을 확인할 수 있는 충분한 고해상도의 영상을 획득하였다. 최근 국내에서 mouse를 이용한 자기공명영상 연구가 시작되었으나 아직 초기단계라고 평가할 수 있고, mouse는 다른 동물에 비하여 취급/관리하기 쉬우므로 향후 mouse를 이용한 뇌 연구가 활성화 될 것으로 사료된다.

  • PDF