• 제목/요약/키워드: Termination

검색결과 1,176건 처리시간 0.032초

고주파용 Termination 파워저항의 제작 (The fabrication of rf termination power resistor)

  • 류제천;김동진;강병돈;구본급;강전홍;유광민;유권상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.553-555
    • /
    • 2002
  • We were fabricated of rf power resisotor on AlN substrates by thick film process. The characteristics of capacitance and microwave are measured by digital LCR meter and Network analyzer(HP8532D). The results are shown that capacitances are slight greater and microwave characteristics are good values.

  • PDF

고온초전도 DC 케이블 시스템용 PPLP 및 GFRP의 절연 특성 (Dielectric Breakdown Characteristics of PPLP and GFRP for HTS DC Cable System)

  • 김상현;최재형;김우진;장현만;이수길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.5-9
    • /
    • 2011
  • DC high-temperature superconducting(HTS) cable system has attracted a great deal of interest from the view point of low loss, dense structure and large capacity. A HTS cable system is made of cable and termination. The insulating materials and insulation technology must be solved for the long life, reliability and compact of cable system. In this paper, we will report on the dielectric breakdown characteristics of insulating materials for HTS cable and termination. The AC, DC and lightning impulse breakdown strength of laminated polypropylene paper(PPLP) and glass fiber reinforced plastic(GFRP) have been measured under nitrogen pressures in the range of 0.l-0.4MPa. PPLP and GFRP are found to have a significantly higher DC breakdown strength. Also, DC surface flashover voltage of negative polarity is slightly higher than that of positive polarity in GFRP.

154kV 케이블 콘넥터의 설계와 특성 평가 연구 (Performance and Design of Cable Termination for 154kV Class)

  • 조한구;김광용;이철호;이용순
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.112-112
    • /
    • 2010
  • The purpose of development is to localize a connector for connection of cable and GIS for underground transmission system. The cable connector for GIS provides electrical insulation of GIS housing part and makes connection of ultra high voltage electrical apparatus and power cable by controlling electrical stress between electrodes of power cable termination. Generally Korean switchgear makers are using a connector for GIS made by foreign companies. We manufactured sample by best structure design of great capacity conductor connecting part and then modified the design by analysis of shape and section. We completed the suitable sample for current cycling test condition of conductor connecting part sample and ensured surge characteristics of line by short-time current test.

  • PDF

운전 과제 동안 노인의 브레이크 반응시간의 특성 (Characteristics of Brake Response Time During the Driving Performance in the Elderly)

  • 신화경;이호철
    • The Journal of Korean Physical Therapy
    • /
    • 제21권3호
    • /
    • pp.81-86
    • /
    • 2009
  • Purpose: This study compared the characteristics of the brake response time during the driving task between elderly and younger drivers. Methods: The participants consisted of an elderly group (n=12) and a younger group (n=12). The brake response time (BRT), which consisted of the reaction time (RT) and movement time (MT), was assessed in an actual driving car. The BRT was measured at the initiation and termination of the brake response for the driving task Results: The elderly group showed a significantly longer delay in the initiation and termination of the brake response than the younger group. The BRT correlated significantly with both the RT and MT. However, the RT showed a more significant correlation. Conclusion: A delay in the initiation and termination of the brake response may have clinical implications. A further study will be needed to determine the different factors contributing to the driving performance of elderly drivers.

  • PDF

Statistical Analysis of Bivariate Recurrent Event Data with Incomplete Observation Gaps

  • Kim, Yang-Jin
    • Communications for Statistical Applications and Methods
    • /
    • 제20권4호
    • /
    • pp.283-290
    • /
    • 2013
  • Subjects can experience two types of recurrent events in a longitudinal study. In addition, there may exist intermittent dropouts that results in repeated observation gaps during which no recurrent events are observed. Therefore, theses periods are regarded as non-risk status. In this paper, we consider a special case where information on the observation gap is incomplete, that is, the termination time of observation gap is not available while the starting time is known. For a statistical inference, incomplete termination time is incorporated in terms of interval-censored data and estimated with two approaches. A shared frailty effect is also employed for the association between two recurrent events. An EM algorithm is applied to recover unknown termination times as well as frailty effect. We apply the suggested method to young drivers' convictions data with several suspensions.

Operation-level Early Termination Algorithm for Inter-predictions in HEVC

  • Rhee, Chae Eun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권4호
    • /
    • pp.235-242
    • /
    • 2016
  • The emerging High-Efficiency Video Coding (HEVC) standard attempts to improve coding efficiency by a factor of two over H.264/Advanced Video Coding (AVC) at the expense of an increase in computational complexity. Mode decision with motion estimation (ME) is still one of the most time-consuming computations in HEVC, as it is with H.264/AVC. Thus, fast mode decisions are not only an important issue to be researched, but also an urgent one. Several schemes for fast mode decisions have been presented in reference software and in other studies. However, the conventional hierarchical mode decision can be useless when block-level parallelism is exploited. This paper proposes operation-level exploration that offers more chances for early termination. An early termination condition is checked between integer and fractional MEs and between the parts of one partition type. The fast decision points of the proposed algorithm do not overlap those in previous works. Thus, the proposed algorithms are easily used with other fast algorithms, and consequently, independent speed-up is possible.

Design of Main Body and Edge Termination of 100 V Class Super-junction Trench MOSFET

  • Lho, Young Hwan
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.565-569
    • /
    • 2018
  • For the conventional power MOSFET (metal-oxide semiconductor field-effect transistor) device structure, there exists a tradeoff relationship between specific on-state resistance (Ron,sp) and breakdown voltage (BV). In order to overcome this tradeoff, a super-junction (SJ) trench MOSFET (TMOSFET) structure with uniform or non-uniform doping concentration, which decreases linearly in the vertical direction from the N drift region at the bottom to the channel at the top, for an optimal design is suggested in this paper. The on-state resistance of $0.96m{\Omega}-cm2$ at the SJ TMOSFET is much less than that at the conventional power MOSFET under the same breakdown voltage of 100V. A design methodology for the edge termination is proposed to achieve the same breakdown voltage and on-state resistance as the main body of the super-junction TMOSFET by using of the SILVACO TCAD 2D device simulator, Atlas.

반도전 재료를 이용한 Resistivity grading 방식의 XLPE절연 전력케이블용 시험단말에 관한 연구 (A study on the application of testing termination for XLPE Power Cable by Resistivity Grading Method Using Semi-conductive material)

  • 이창영;신두성;;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1105-1107
    • /
    • 1999
  • The purpose of termination for high voltage tests of XLPE power cable is to prevent flashover during the breakdown test of specimen as well as to withstand the specified voltage between its conductor and screen without failure. For easier treatment and simpler construction of testing termination, resistivity grading method using semi-conductive material was employed. Based on the fundamental theory, its failure characteristics by changing the resistivity of semi-conductive material on the insulation surface was investigated. With two layers construction by difference resistivity on their surfaces, much improved result than that of one resistivity was obtained through the experiment for MV cable.

  • PDF

GPU를 이용한 3차원 텍스쳐 기반 볼륨 렌더링의 속도 향상 기법 (Acceleration Techniques for 3D Texture Based Volume Rendering using GPU)

  • 이중연;구기범
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2006년도 한국컴퓨터종합학술대회 논문집 Vol.33 No.1 (A)
    • /
    • pp.118-120
    • /
    • 2006
  • 최신 GPU는 일반 CPU보다 10배 이상 빠른 연산능력을 갖추고 있는데다가 사용자가 직접 프로그래밍 할 수 있기 때문에 이를 이용한 고속 볼륨 렌더링 알고리즘에 대한 연구가 활발하게 진행되고 있다. 그러나 스트림 프로세싱에 특화 돼있는 GPU의 특성상 early ray termination과 empty space skipping을 구현하는 것이 쉽지만은 않다. 특히 지금까지 제안됐던, 프록시 도형(proxy geometry)을 사용하는 볼륨 렌더링 알고리즘은 empty space skipping은 비교적 효율적으로 구현하지만 early ray termination의 지원은 상대적으로 미비했다. 본 논문에서는 스텐실 버퍼와 OpenGL 확장(extension)을 이용한 2-Pass 알고리즘을 통해서 early ray termination과 empty space skipping을 동시에 구현하는 방법을 제시하고, 그 성능을 측정했다.

  • PDF

생쥐 LP1-1 세포에서 S phase 동안 nuclear matrix에 고정되어 있는 복제 끝점 (Termination Sites of fleplication Are Anchored to the Nuclear Matrix during S Phase in Mouse LPI-1 Cells)

  • 이형호;이갑열
    • 한국동물학회지
    • /
    • 제37권3호
    • /
    • pp.318-323
    • /
    • 1994
  • The association of replication origins/termini with nuclear matrix during S phase was investigated by DNase digestion of halo structures in synchronized mouse LPI-1 cells. The binding of parental DNA to nuclear matrix was constant throughout S phase. When nuclear matrix was isolated from the cells pulse-labeled with 3H-thvmidine at various stases of S phase, total 3H-labels associated with nuclear matrix were specifically higher at So, Sa and Ss stages than other stases of S phase, suggesting that the newly synthesized DNAs at those stages are not excluded out of nuclear matrix. Similar patterns were obsenred from the pulse-chase experiments, in which cells were pulse-labeled at each stage of S phase and further incubated for 1 hr. These results suggest that the replication origins and termini are fixed at the nuclear matrix, and that the nuclear matrix binding fractions of DNA at 3C-pause may contain a large population of replication origins and termination sites.

  • PDF