• 제목/요약/키워드: Tension band technique

검색결과 16건 처리시간 0.022초

Percutaneus Cerclage Wiring in Distal Clavicle Fracture Type 2a - One Case Report - (원위 쇄골 골절 2a 형에서의 경피적 환상 강선 고정술 -1례 보고-)

  • Kim, Jae-Hwa;Lee, Soon-Chul;Cho, Duck-Yun;Yoon, Hyung-Ku;Lee, Yoon-Seok
    • Clinics in Shoulder and Elbow
    • /
    • 제9권1호
    • /
    • pp.124-129
    • /
    • 2006
  • Distal clavicular fracture frequently requires operative treatment due to high rate of non-union. The operative technique includes the tension band wiring, K- wire fixation, and cerclage wiring etc. Each method has disadvantages somewhat like pin migration or acromioclavicular joint injury and so on. For the distal clavicular fracture type 2a, because of its oblique fracture line, the cerclage wiring is suitable. We performed the cerclage wiring percutaneously under minimal incision without injury to periosteum for the patient who had the distal clavicular fracture type 2a, and the result was favorable.

Surgical Treatment of Olecranon Fractures

  • Koh, Kyoung-Hwan;Oh, Hyoung-Keun
    • Clinics in Shoulder and Elbow
    • /
    • 제20권1호
    • /
    • pp.49-56
    • /
    • 2017
  • Since the olecranon fractures are caused by relatively low-energy injuries, such as a fall from standing height, they are usually found without comminution. Less commonly they can be developed by high-energy injuries and have severe concomitant comminution or injuries to surrounding structures of the elbow. Because the fracture by nature is intra-articular with the exception of some avulsion-type fracture, a majority of olecranon fractures are usually indicated for surgical treatment. Even if there is minimal displacement, surgical treatment is recommended because there is a possibility of further displacement by the traction force of triceps tendon. The most common type of olecranon fracture is displaced, simple non-comminuted fracture (that is, Mayo type IIA fractures). Although tension band wiring was the most widespread treatment method for these fractures previously, there is some trends toward fixation using locking plates. Primary goal of the surgery is to restore a congruent joint and extensor mechanisms by accurate reduction and stable fixation so that range of motion exercises can be performed. The literature has shown that good clinical outcomes are achieved irrespective of surgical fixation technique. However, since the soft tissue envelope around the elbow is poor and the implants are located at the subcutaneous layer, implant irritation is still the most common complication associated with surgical treatment.

Applications of fiber optic sensors for structural health monitoring

  • Kesavan, K.;Ravisankar, K.;Parivallal, S.;Sreeshylam, P.
    • Smart Structures and Systems
    • /
    • 제1권4호
    • /
    • pp.355-368
    • /
    • 2005
  • Large and complex structures are being built now-a-days and, they are required to be functional even under extreme loading and environmental conditions. In order to meet the safety and maintenance demands, there is a need to build sensors integrated structural system, which can sense and provide necessary information about the structural response to complex loading and environment. Sophisticated tools have been developed for the design and construction of civil engineering structures. However, very little has been accomplished in the area of monitoring and rehabilitation. The employment of appropriate sensor is therefore crucial, and efforts must be directed towards non-destructive testing techniques that remain functional throughout the life of the structure. Fiber optic sensors are emerging as a superior non-destructive tool for evaluating the health of civil engineering structures. Flexibility, small in size and corrosion resistance of optical fibers allow them to be directly embedded in concrete structures. The inherent advantages of fiber optic sensors over conventional sensors include high resolution, ability to work in difficult environment, immunity from electromagnetic interference, large band width of signal, low noise and high sensitivity. This paper brings out the potential and current status of technology of fiber optic sensors for civil engineering applications. The importance of employing fiber optic sensors for health monitoring of civil engineering structures has been highlighted. Details of laboratory studies carried out on fiber optic strain sensors to assess their suitability for civil engineering applications are also covered.

The Treatment of One-Part Fractures of the Greater Thberosity of the Proximal Humerus (상완골 대결절 일분 골절의 치료)

  • Park Tae-Soo;Kim Tae-Seung;Park Ye-Soo;Kim Do-Hyeung;Kang Chang-Nam;Whang Kuhn-Sung
    • Clinics in Shoulder and Elbow
    • /
    • 제2권1호
    • /
    • pp.21-27
    • /
    • 1999
  • Purpose : The purpose of this study was to evaluate the functional outcomes of one-part fracture of the greater tuberosity that had been treated either by a conservative treatment or an operative approach. Materials and Method: Eighteen shoulders in 18 patients who had an one-part fracture of the greater tuberosity of the proximal humerus were managed, and the average follow-up period was 4 years and 10 months (range, 1 year to 8 years 6 months). Results: According to Neer's criteria for evaluation of results, in the group of 13 patients managed nonoperatively, the results were good or excellent in ten patients, fair in one, and poor in two. In the group managed operatively, the results were excellent in all five patients. Conclusion: If the displacement of the fragment is more than 5mm in young active patients, and more than 3mm especially in athletes and heavy laborers involved in overhead activity, the fragment should be mobilized, repaired and fixed into its original bed or a little bit inferolaterally with multiple heavy non-absorbable sutures, tension band technique, or cancellous screws and washers. We would suggest that the patients showing one-part fracture of the greater tuberosity of the proximal humerus should be evaluated individually.

  • PDF

Stability of PS Opals in Supercritical Carbon Dioxide and Synthesis of Silica Inverse Opals

  • Yu, Hye-Min;Kim, Ah-Ram;Moon, Jun-Hyuk;Lim, Jong-Sung;Choi, Kyu-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권7호
    • /
    • pp.2178-2182
    • /
    • 2011
  • Recently, the synthesis of ordered macroporous materials has received much attention due to its potential use as photonic band gap materials.$^1$ In this study, we have used the three-dimensional (3D) latex array template impregnated with benzenesulfonic acid (BSA), which is capable of catalyzing the reaction using tetraethyl orthosilicate (TEOS) as a precursor and distilled water. The polystyrene (PS) templates were reacted with TEOS in $scCO_2$ at 40 $^{\circ}C$ and at 80 bar. In the reactor, TEOS was filtrated into the PS particle lattice. After the reaction, porous silica materials were obtained by calcinations of the template. The stability test of the PS template in pure $CO_2$ was conducted before the main experiment. Scanning electron microscopy (SEM) images showed that the reaction in $scCO_2$ takes place only on the particle surface. This new method using $scCO_2$ has advantages over conventional sol-gel processes in its capability to control the fluid properties such as viscosity and interfacial tension. It has been found that the reaction in $scCO_2$ occurs only on the particle surface, making the proposed technique as more rapid and sustainable method of synthesizing inverse opal materials than conventional coating processes in the liquid phase and in the vapor phase.

Treatment of Transverse Patella Fracture with Minimally Invasive Load-Sharing Patellar Tendon Suture and Cannulated Screws (최소 침습 기법 슬개건 부하 분산 봉합술과 유관 나사못을 이용한 슬개골 횡골절의 치료)

  • Lee, Beom-Seok;Park, Byeong-Mun;Yang, Bong-Seok;Kim, Kyu-Wan
    • Journal of the Korean Orthopaedic Association
    • /
    • 제56권6호
    • /
    • pp.540-545
    • /
    • 2021
  • A transverse fracture is the most common type of displaced patella fracture requiring surgery. These fractures are commonly fixed with parallel Kirschner wires or screws that cross the fracture line, often with an additional tension band. Nevertheless, conventional fixation methods of patella fractures have prevalent complications caused by the protrusion of wires or pins. These complications necessitate additional surgery for hardware removal, increase medical cost, and can limit the function of the knee joint. This paper reports cases treated with a minimally invasive load-sharing percutaneous suture of the patella tendon. The procedure provides reliable fixation for transverse patella fractures, minimizes soft tissue injuries, preserves blood flow, and reduces postoperative pain. In addition, the procedure also reduces the irritation and pain caused by the internal fixture, thereby reducing the risk of restricted knee joint movement.