• 제목/요약/키워드: Tension Wire

검색결과 247건 처리시간 0.025초

AC loss comparison of Bi-2223 and coated conductor HTS tapes under bending

  • Kim, Hae-Joon;Cho, Jeon-Wook;Sim, Ki-Deok;Kim, Jae-Ho;Kim, Seok-Ho;Jang, Hyun-Man;Lee, Soo-Gil
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권4호
    • /
    • pp.41-45
    • /
    • 2007
  • Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motor and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. AC loss is also important consideration for many large-scale superconducting devices. In the fabrication of the devices, the critical current $(I_c)$ of the high temperature superconductor degrades due to many reasons including the tension applied by bending and thermal contraction. These bending or tension reduces the $I_c$ of superconducting wire and the $I_c$ degradation affects the AC loss of the wire. The $I_c$ degradation and AC loss (self field loss) of Bi-2223 HTS and Coated conductor were measured under tension and bending conditions at 77K and self-field.

오토백 인장장치의 적용성 (Application by Auto Back Tension System)

  • 박상국
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.66-72
    • /
    • 2006
  • The ground anchoring has been utilized over 40 years. It is growing the application of the removal ground anchor with tension force for holding earth retaining constructions in the city. It transmits tension stress of prestressed steel wire through grouting to fixed the ground that is of great advantage adjacent ground stability. Nowadays, we can find the compression dispersion anchor on many site. But, it has some problems in behavior of anchors because of impossible to tense p.c strand uniformly under the existing equipment due to different length of p c strand. Hence, motive of this research was to study the application of the newly developed tension system, that analyze and compare with the current anchoring method build on the data of in-site test and laboratory test. As a result, in case of auto back tension system, it became clear that tension pressure was equally distributed among the steal wires but the existing tension system showed sign of instability by indicating stress deflection of about 30% compare with design load. This can cause an ultimate failure of the concentrated p.c strand and a shear failure of ground.

  • PDF

고강도 저손실 가공송전선의 개발(I) - 기계적 특성 (Development of High Strength and Low Loss Overhead Conductor(I) - Mechanical Properties)

  • 김병걸;김상수;박주환
    • 한국전기전자재료학회논문지
    • /
    • 제18권12호
    • /
    • pp.1152-1158
    • /
    • 2005
  • New conductor is developed by using high strength nonmagnetic steel(NM) wire as the core of overhead conductor. This conductor is called ACNR overhead conductor(Aluminum Conductor Nonmagnetic Steel Reinforced). Formed by the combination of aluminum alloy wire and high strength nonmagnetic steel wire, it has about the same weight and diameter as conventional ACSR overhead conductor. To enhance properties beneficial in an electrical and mechanical conductor during the process of high strength nonmagnetic steel wire, we made a large number of improvements and modifications in the working process, aluminum cladded method, and other process. ACNR overhead conductor, we successfully developed, has mechanical and electrical properties as good as or even better than conventional galvanized wire. Microstructure of raw material M wire was austenite and then deformed martensite after drawing process. Strength at room temperature is about $180kgf/mm^2\~200kgf/mm^2$. NM wire developed as core of overhead conductor shows heat resistant characteristics higher than that of HC wire used as core of commercial ACSR overhead conductor, Strength loss was not occur at heat resistant test below $600^{\circ}C$. Fatigue strength of vibration fatigue is about $32kgf/mm^2\~35kgf/mm^2$ and that of tension-tension fatigue is $90kgf/mm^2\~120kgf/mm^2$ which is $50\~65\%$ of tensile strength.

와이어방전가공시 북량현상 예측에 관한 연구 (A Study on the Hand Drum Form Predict in the Wire Electric Discharge)

  • 김선진;성백섭
    • 한국정밀공학회지
    • /
    • 제20권1호
    • /
    • pp.70-78
    • /
    • 2003
  • The purpose of this study was to present the method to choose the optimization machining condition for the wire electric discharge machine. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. In this experiment, we changed no-node voltage to 7 and 9, pulse-on-time to 6$mutextrm{s}$, 8$mutextrm{s}$ and 10$mutextrm{s}$, pulse-off-time to 8$mutextrm{s}$, 10$mutextrm{s}$ and 13$mutextrm{s}$, and experimented on wire tension at room temperature by 1000gf, 1200gf, and 1400gf, respectively.

CRT 텐션 마스크의 장력 이완 저감을 위한 연구 (A Study for Reducing Tension Loosening in CRT Tension Mask)

  • 정일섭
    • 한국정밀공학회지
    • /
    • 제20권6호
    • /
    • pp.214-221
    • /
    • 2003
  • Tension mask assembly is positioned right behind the glass-made front panels of CRT type display devices. The frame-supported thin metal sheet contains numerous slits, through which electron beams are focused to enhance definition. Pretension is imposed on the masks, especially for enlarged flat screens, in order to avoid vibration due to acoustic or mechanical impact. High temperature assembly process subsequent to pretensioning, however, degenerates the creep resistance of common mask materials, and if tensile stress is high enough, tension on the mask may be loosened substantially due to creep deformation. In this study, the assembly is modeled as a combined structure of beams and wire array, and a numerical simulation is attempted for pretensioning followed by high temperature process. According to a model study, small amount of creep strain is likely to be generated, but its adverse influence is not negligible. Some structural modification measures to reduce the creep-induced tension loosening are proposed and evaluated. Also, optimal configuration of frame structure is sought for, which maintains high tension of masks and minimizes the possible creep of frame simultaneously.

지점부 상부슬래브에 PS강선 긴장된 강 박스거더교의 구조적 특성 분석 (Structural Characteristics Analysis of Steel Box Girder Bridge being stressed the PS Steel Wires at the Upper Slab of the Intermediate Support)

  • 차태권;장일영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권2호
    • /
    • pp.1-7
    • /
    • 2021
  • 강 박스거더 교량의 연속지점부 바닥판은 상부플랜지와 합성되는 구조이며 장경간 교량에서는 지점부 바닥판에 인장균열이 발생할 수 있는 구조로서 내구성 저하 등의 문제가 발생하고 있다. 이는 장경간 적용시 고정하중 및 활하중의 영향으로 슬래브의 교축방향 인장응력이 설계인장강도를 초과하기 때문이다. 이에 지점부 슬래브에 교축방향 철근을 추가하여 인장균열을 제어하고 추가의 압축응력 도입이 필요하다. 이러한 문제점 해결을 위해 연속지점부 상부슬래브의 인장응력 구간에 PS강선 긴장으로 압축응력을 도입하는 강 박스거더교의 구조계를 제안하였고, 이에 따른 구조적 성능을 유한요소해석과 실물시험체의 강선긴장 실험을 통해서 비교 검증하였다. PS강선 긴장을 통해 부모멘트부에 발생하는 슬래브의 인장응력 및 균열을 제어할 수 있는 압축응력을 도입하면 기존 강 박스거더교에 비해 구조안전성 개선 및 내구성능을 강화할 수 있다.

STD-11 Die-hole 와이어 컷 방전가공시 가공조건에 따른 북현상 고찰 (Hand drum forms of STD-11 Die-hole in Wire-cut Electronic discharge Machining Conditions)

  • 조규재
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.567-572
    • /
    • 2000
  • From the experimental study of W-EDM for alloyed steel, the characteristics such as Hand Drum Form and surface roughness have been observed and evaluated for various conditions. In square hole, the increase of IP as to made condition, the calculate high value of surface roughness. Also compare dimensionless square hole with circle hole' graph, In circle hole, if a value of surface roughness IP 6 in a side of circle it show a 0.4${\mu}{\textrm}{m}$ and in IP 8, 0.6${\mu}{\textrm}{m}$, in IP 10, 0.7${\mu}{\textrm}{m}$, in IP 12, 0.8${\mu}{\textrm}{m}$ higher than before. This figure show the surface roughness is higher than before, because a table move in either X-axis or Y-axis in square hole, on the contrary, in circle there table move in X-axis and Y-axis at the same time. hand drum form getting small when wire tension increase 1000gf to 1500gf, at the same working conditions. The smaller of off time, the maller of hand drum form in same condition and same wire tension. but if you compare square hole with circle hole' graph, hand drum form displayed in maintained term of working condision, on the contrary, in case of square hole variation of hand drum form is more increase than a grow of IP

  • PDF

MAG 용접의 스패터 발생 및 용적이행현상에 미치는 Si의 영향 (Effect of Si on Spatter Generation and Droplet Transfer Phenomena of MAG Wwlding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제17권3호
    • /
    • pp.36-43
    • /
    • 1999
  • The effect of Si content in welding wires on spattering characteristics and droplet transfer phenomena was studied. In MAG welding using 80% Ar-20% $CO_2$ shielding gas, spattering characteristics and droplet transfer phenomena were varied with Si content of wire. With increasing Si content, the spattering ratio and the ratio of large size spatter $(d\geq1.0mm)$ were increased. The increase of Si content in molten metal made surface tension increase due to reduction of oxygen content, which resulted from deoxidizing action of silicon. The increase of surface tension resulted in unstable transfer phenomena and arc instability in both short circuit and spray region. With changing Si content of wire, spattering characteristics and droplet transfer phenomena was directly influenced by the variation of surface tension, compared with the effect of arc stability.

  • PDF

강선적층방식을 이용한 냉간 단조용 초고압용기의 개발에 관한 연구

  • 박훈재;나경환;조남선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 추계학술대회 논문집
    • /
    • pp.77-81
    • /
    • 2001
  • The present study is concemed with the design of high pressure container reinforced by winding wire used as a die component in cold forming of metals. The stress analysis for the design of high pressure container has been made under an optimal design criterion. The wire-winding equipment and the tension control unit according to the theoretical winding force are installed. The circumferential stresses at the inner wall of die housing are measured every turn of wire-winding. The measure stresses are in good agreement with the analytically predicted ones.

1MVA 초전도 변압기 전류 통전 시험 (Transportation Current Test for 1 MVA HTS Transformer)

  • 박정호;송희석;김우석;김성훈;이동근;최경달
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.41-44
    • /
    • 2003
  • We manufactured double pancake type windings with BSCCO wire for 1MVA HTS transformer. To verify cracks of HTS wire and performance of manufactured windings, the transportation current was measured. In this paper, we present result of the transportation current test as a DC current and compare a drop of current performance of HTS wire due to tension and rounding during the manufacturing with technical data. We obtained good results and this will be useful for another manufacturing of HTS winding

  • PDF