• Title/Summary/Keyword: Tenolysis

Search Result 6, Processing Time 0.018 seconds

Tenolysis after the reconstruction of PIP joint of the finger using second toe PIP joint free flap (제 2족지 근위지관절 유리피판술을 이용한 수지 근위지관절 재건 후 시행한 건박리술)

  • Park, Hyoung Joon;Lee, Dong Chul;Kim, Jin Soo;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.450-457
    • /
    • 2009
  • Purpose: The second toe PIP joint free flap is a method of reconstruction used for abnormalities of the PIP joint of the finger. We report the results of the additional tenolysis in patients with a difference between passive ROM and active ROM after second toe PIP joint free flap. Methods: From March 2001 to July 2008, tenolysis was performed in patients with a difference in their active and passive ROM after second toe PIP joint free transfer, performed on 14 fingers. We performed a retrospective analysis of the medical records, noting the clinical and radiological findings. In addition, we measured the preoperative and postoperative range of motion of the PIP joint. Results: The average active ROM was $22.5^{\circ}$ at the three months after the joint transfer surgery, and was $38^{\circ}$ after additional tenolysis between five months and twelve months after the joint transfer. Conclusions: Additional tenolysis, after the second toe PIP joint free flap, might be a good option for improved results in patients with difference in active and passive ROM of a transferred PIP joint.

Tumescent Local Anesthesia for Hand Surgery: Improved Results, Cost Effectiveness, and Wide-Awake Patient Satisfaction

  • Lalonde, Donald;Martin, Alison
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.312-316
    • /
    • 2014
  • This is a review article of the wide-awake approach to hand surgery. More than 95% of all hand surgery can now be performed without a tourniquet. Epinephrine is injected with lidocaine for hemostasis and anesthesia instead of a tourniquet and sedation. This is sedation-free surgery, much like a visit to a dental office. The myth of danger of using epinephrine in the finger is reviewed. The wide awake technique is greatly improving results in tendon repair, tenolysis, and tendon transfer. Here, we will explain its advantages.

Reconstruction of Electrical Burned Hand by Posterior Tibial Arterial Free Flap (후경골 동맥 유리 피판에 의한 수부 전기 화상의 재건)

  • Choi, Soo-Joong;Seo, Eun Min;Lee, Chang Ju;Chang, Jun Dong;Kim, Suk Wu;Lee, Sang Hun;Lee, Dong Hun;Seo, Young jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.14-23
    • /
    • 2004
  • Introduction: The hand and wrist are particularly susceptible to electrical burn. Skin defect with damage or exposure of underlying vital structure requires coverage by skin flap especially in case of the need for late reconstruction. We are reporting 4 cases of electrical burned hand treated by posterior tibial arterial free flap. The commonly used skin flaps such as scapular flap or groin flap are too bulky so that they are not satisfactory in function and cosmetic appearance. So we tried to cover them with a more thin skin flap. Materials and Method: From January 2002 to June 2003, four cases of hand and wrist electrical burn were covered using posterior tibial arterial free flap. All the cases were due to high voltage electrical burn. Age ranged from 31 years to 38 years old and all the cases were male patients. Recipient sites were 2 wrist, one thenar area and one knuckle of 2.3rd MP joint. Additional procedures were flexor tenolysis (simultaneous), FPL tenolysis and digital nerve graft (later) and extensor tendon reconstruction (later). Result: All the flap have survived totally without any complication including circulatory concern about the donar foot. Posterior tibail arterial free flap was so thin that debulking procedure was not required. Conclusion: For skin coverage of the hand & wrist region, posterior tibial arterial free flap have many advantages such as reliable anatomy, easy dissection and easy anastmosis with radial or ulnar artery and possibility of sensory flap. The most helpful advantage for hand coverage is its thinness. So we think this flap is one of the very useful armamentarium for reconstructive hand surgery.

  • PDF

Bilateral Digital Extensor Hypoplasia Correction: A Case Report and Systematic Review

  • Marudeen Aivaz;Esperanza Mantilla-Rivas;Ashleigh Brennan;John Thomas;Elizabeth L. Malphrus;Monica Manrique;Albert K. Oh;Gary F. Rogers
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.177-181
    • /
    • 2023
  • Digital extensor hypoplasia (DEH) is a rare malformation that presents with loss of active finger extension at the metacarpophalangeal (MCP) joints. Descriptions of optimal treatment and outcomes in this population are sparse. We describe successful operative treatment of a child with DEH involving the extensor digitorum communis, extensor digiti minimi, and the extensor indicis proprius tendons. The 5-year-old male patient was referred for severe limitation on bilateral finger extension since birth. He had been previously diagnosed with arthrogryposis and managed conservatively. Due to lack of improvement, magnetic resonance imaging was done evidencing hypoplasia/aplasia of the extensor tendons. The patient underwent successful tendon transfers using extensor carpi radialis longus to the common extensor tendons, and one hand required an additional tenolysis procedure. 2 years postoperatively, his MCP position and finger extension are markedly improved, and he is able to grip objects without limitation or difficulty. The patient returned to full activity without restriction.

Reconstruction of Mutilating Hand with Pollicization and Anteromedial Thigh Perforator Free Flap - A Case Report - (무지 형성술 및 전내측 대퇴부 천공지 피판의 연속 술기를 이용한 수부 절단 손상의 재건 - 증례 보고 -)

  • Lee, Hyun-Jic;Eo, Su-Rak;Cho, Sang-Hun
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.1
    • /
    • pp.56-60
    • /
    • 2012
  • Purpose: Thumb reconstruction plays most important role in hand injuries because total loss of a thumb constitutes about 40% disability in the hand. The reconstruction can be accomplished by pollicization, free toe-to-thumb transfer, wrap around procedure and lengthening extraction. However, we sometimes need consecutive or double free flaps in the reconstruction of mutilating hand injuries. Methods: We reconstructed a mutilating hand injury in a 54-years old man. Because of severe crushing injury of right thumb and index fingers, we reconstructed a thumb with pollicization using nearly amputated middle finger. Although it survived completely, the adjacent soft tissues which had been covered by fillet flap from the space past was necrosed on 1 month. We debrided the necrotic tissues and covered it with anteromedial thigh perforator free flap consecutively because he had an anatomical variation in branches of lateral femoral circumflex artery. Results: He had an uneventful postoperative course without any complication such as infection, dehiscence and flap necrosis. Three months later, he had undergone tenolysis and defatting procedure of flap site. He recovered the some amount of grip function and was happy with the result. Conclusion: In severe hand trauma including thumb amputation, thumb reconstruction using pollicization and perforator free flap could be an alternative option. It provides minimal donor site morbidity and an acceptable functional result.

  • PDF

Loop Suture Technique for Flexor Digitorum Profundus Tendon Repair in the Insertion Site (고리 봉합법을 이용한 심부 수지 굴건 종지부에서의 건봉합)

  • Lee, Kyu-Cheol;Lee, Dong-Chul;Kim, Jin-Soo;Ki, Sae-Hwi;Roh, Si-Young;Yang, Jae-Won
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.650-658
    • /
    • 2010
  • Purpose: In the case of repair for far distal parts of FDP (Flexor digitorum profundus) division, the method of either pull-out suture or fixation of tendon to the distal phalanx is preferred. In this paper, the results of a modified loop suture technique used for the complete division of FDP from both zone 1a and distal parts of zone 1b in Moiemen classification are presented. Methods: From July 2006 to July 2009, the modified loop suture technique was used for the 10 cases of FDP in complete division from zone 1a and distal parts of zone 1b, especially where insertion sites were less than 1 cm apart from a tendon of a stump. In a suture technique, a loop is applied to each distal and proximal parts of tendon respectively. Core suture of 2-strand and epitendinous suture are done with PDS 4-0. Out of 10 patients, the study was done on 6 patients who were available for the followup. The average age of the patients was 49.1 years (in the range from 26 to 67). 5 males and 1 female patients were involved in this study. There were 3 cases with zone 1a and distal parts of zone 1b. The average distance to the distal tendon end was 0.6 cm. There were 5 cases underwent microsurgical repair where both artery and nerve divided. One case of only tendon displacement was presented. The dorsal protective splint was kept for 5 weeks on average. The results of the following tests were measured: active & passive range of motion, grip strength test, key pinch and pulp pinch test. Results: The follow-up period on average was 11 months, in the range from 2 to 20 months. There was no case of re-rupture, but tenolysis was performed in 1 cases. In all 6 cases, the average active range of motion of distal interphalangeal joint was 50.8 degree. The grip strength (ipsilateral/contralateral) was measured as 88.7% and the pulp pinch test was 79.2% as those of contralateral side. Flexion contracture was presented in 2 cases (15 degree on average) and there was no quadrigia effect found. Conclusion: Despite short length of tendon from the insertion site in FDS rupture in zone 1a and distal parts of zone 1b, sufficient functional recovery could be expected with the tendon to tendon repair using the modified loop suture technique.