• Title/Summary/Keyword: Tendons

Search Result 527, Processing Time 0.023 seconds

Dynamic Instability of Submerged Floating Tunnels due to Tendon Slack (긴장재 느슨해짐에 따른 해중 터널의 동적 불안정 거동)

  • Won, Deok Hee;Kim, Seungjun
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.401-410
    • /
    • 2017
  • This study deals with dynamic instability of a tendon moored submerged floating tunnel (SFT) due to tendon slack. In general, environmental loadings such as wave and current govern SFT design. Especially, the wave force, whose amplitude and direction continuously change, directly induces the dynamic behavior of the SFT. The motion of the floating tube, induced by the wave force, leads dynamic response of the attached tendons and the dynamic change of internal forces of the tendons significantly affects to the fatigue design as well as the structural strength design. When the severe motion of the SFT occurs due to significant waves, tendons might lose their tension and slack so that the floating tube can be transiently instable. In this study, the characteristics of dynamic instability of the SFT due to tendon slack are investigated performing hydrodynamic analysis. In addition, the effects of draft, buoyancy-weight ratio, and tendon inclination on tendon slack and dynamic instability behavior are analytically investigated.

The Effect of Hyaluronate-Carboxymethyl Cellulose on Tissue Adhesion after Achilles Tendon Tenorraphy in Rats (백서의 아킬레스 건 봉합 후 Hyaluronate-Carboxymethyl cellulose가 조직 유착에 미치는 영향)

  • Lee, Jung-Hee;Jeong, Bi-O;Kim, Gou-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of Sodium hyaluronate-Sodium carboxymethyl cellulose (HA-CMC) on tissue adhesion after tenorrhapy in tenotomized Achilles tendon of the Sprague-Dawley rat. Materials and Methods: Twenty-eight legs of 14 Sprague-Dawley rat were used in study. After tenotomy of the Achilles tendons, tenorrhaphies were performed. Simple tenorrhaphy without any other procedures were performed on the left Achilles tendons (control group), and additional HA-CMC injections were done prior to the tenorrhaphy on the right Achilles tendons (HA-CMC group). Gross and histological examinations were made to identify differences between the two groups, 1, 2, 6, 8, 10, 12 and 14 weeks respectively. Results: Distinct decrease in granulation tissues and adhesions were seen in the HA-CMC group during gross inspection at 6 and 8 week after the operation. On histological analysis of the HA-CMC group, although increased infiltrations of inflammation cells were observed during 1 week, less adhesion were seen at 6, 8 and 10 weeks after the operation. In HA-CMC group, superior healing processes were seen at 6, 8 and 10 weeks and less fibrotic changes, compared to control group, were seen at 2 and 6 weeks. Conclusion: Prevention of adjacent tissue adhesion was made possible through decrease in collagen deposition and fibrosis by injecting HA-CMC before tenorrhaphy of Achilles tendon. Also, histologically faster healing process of the collagen fibers within the Achilles tendon was observed.

  • PDF

Reconstruction of the Extremities with Lateral Arm Free Flap (외측 상완 유리 판을 이용한 사지 재건술)

  • Lee, Jun-Mo;Lee, Ju-Hong;Kim, Hak-Ji
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.51-57
    • /
    • 2004
  • Introduction: To cover the exposed tendons and bones in the foot and hand which need coverage and abundant vascular flow, lateral arm flaps were transferred. Lateral arm flap is a thin and innervated fasciocutaneous flap with a lower lateral cutaneous nerve and posterior radial collateral artery. Materials and methods: From October 1992 through September 2003, we have performed 5 lateral arm flaps for reconstruction of the exposed achilles tendons in 2 cases and the exposed forearm extensors, 2nd to 5th metacarpal bones and scaphoid each 1 case. The causes were traffic accident in 2 cases and machinary injury in 3 cases. Age range was between 31 to 74 (average 50) and all male except 1. Posterior lateral collateral artery and venae comitantes were anastomosed by end to end in 3 cases and vena comitante in 2 cases. Lower lateral cutaneous nerve was anastomosed with a branch of superficial radial nerve in 2 cases. Results: The results were evaluated by survival of the flap, sensory discrimination, cosmesis and comfort in the activities of the daily living. All flaps were survived. Sensory recovery was graded as deep cutaneous pain sensibility in 2 cases. Cosmesis was moderately satisfied and comfort was good except 1 as moderate. Postoperative defatting procedure was done in 1 case and skin abrasion was occurred in 1 case. Conclusion: Lateral arm flap was suitable for coverage of the exposed achilles tendons and exposed forearm extensors, metacarpals and scaphoid in the wrist.

  • PDF

Flexural Strength Evaluation of PSC Beam with Loss of PS Tendon Area (PS강재의 단면적 감소에 따른 PSC보의 휨강도 평가)

  • Park, Soon-Hyung;Kim, Yong-Tae;Youn, Seok-Goo;Kim, Eun-Kyum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.309-312
    • /
    • 2008
  • This paper describes ultimate load tests which were performed to show the effects of prestress loss and tendon corrosion on the flexural strength of post-tensioned concrete beams and the occurrence of wire fracture. Five test specimens were fabricated in laboratory with the variations of the prestress of tendons and the loss of tendon area. For two specimens, small area of tendon at the center of the beam was exposed by using diameter 25mm drill and the exposed tendon was corroded using accelerated corrosion equipment. During the tests, deflections, crack width, and strain changes were measured and acoustic events were monitored with two acoustic sensors. Tests results show that the ultimate flexural strength of test specimens with corroded tendons is smaller than the predicted flexural strength which is calculated considering the loss of tendon area. It is considered that estimation of flexural strength of PSC beams with corroded tendons is very complicated just based on the loss of tendon area obtained by one-side visual inspection.

  • PDF

An Experimental Study on Behavior of Multi-Spliced Girder with Dry Joint (건식접합부를 갖는 Multi Spliced 주형의 거동에 관한 실험적 연구)

  • Kim Kwang-Soo;Seo Bong-Won;Park Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.229-236
    • /
    • 2005
  • To cope with increasing requirements of cost reduction, labor saving, and rapid construction, the purpose of this study is to investigate the structural behavior of PSC monolithic and spliced girders. Three tests were conducted on reduced-scale girder specimens having same type. This paper presents the result of experimental studies on the load-deflection behavior in which different joint and amount of tendon as major variables were investigated. The first one used a monolithic girder was arranged with three tendons. The second one used a spliced girder was joined with three tendons after producing five segments. And the third girder was produced in same conditions with the second girder and arranged with additional tendons. The experimental results show the difference of behavior between monolithic and spliced girders.

Axisymmetric Modeling of Dome Tendons in Nuclear Containment Building I. Theoretical Derivations (원전 격납건물 돔 텐던의 축대칭 모델링 기법 I. 이론식의 유도)

  • Jeon Se-Jin;Chung Chul-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.521-526
    • /
    • 2005
  • Prestressing tendons in a nuclear containment building dome are non-axisymmetrically arranged in most cases. However, simple axisymmetric modeling of the containment has been often employed in practice to estimate structural behavior for the axisymmetric loadings such as an internal pressure. In this case, the axisymmetric approximation is required for the actual tendon arrangements in the dome. Some procedures are proposed that can implement the actual 3-dimensional tendon stiffness and prestressing effect into the axisymmetric model. Prestressing tendons, which are arranged in 3 or 2-ways depending on a containment type, are converted into an equivalent layer to consider the stiffness contribution in meridional and hoop directions. In order to reflect the prestressing effect, equivalent load method and initial stress method are devised and the corresponding loads or stresses are derived in terms of the axisymmetric model. In a companion paper, the proposed schemes are applied into CANDU and KSNP(Korean Standard Nuclear Power Plant) type containments and are verified through some numerical examples comparing the analysis results with those of the actual 3-dimensional model.

The Effects of Computer Game Exposure on Musculoskeletal Pathological Symptoms in Adolescents

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.1
    • /
    • pp.55-60
    • /
    • 2018
  • Objective: This study aimed to analyze the effects of computer game exposure on pathological musculoskeletal symptoms in adolescents. Method: This study included 10 male junior high school students who used computers less than 3 times a week for 1 hr per day. The subjects were asked to play computer games for 4 hr. Magnetic resonance imaging of the hand and wrist, from the distal radius and ulnar head to the distal phalanges, and radiography of the cervical vertebrae were performed before and after playing computer games. For each dependent variable, a paired t-test was performed to identify significant changes before and after a 4-hr active computer game (p<.05). Results: The horizontal diameters of the flexor tendons in the index and middle fingers were significantly reduced after playing computer games. The horizontal diameters of the flexor tendons of other fingers did not show any significant differences, but there was a tendency toward a decrease after playing computer games. There was no significant change in the cervical lordosis angle before and after playing computer games. However, the cervical lordosis angle was relatively decreased. Conclusion: The results of this study showed that computer game exposure had direct and indirect effects on morphological changes of flexor tendons. In addition, playing computer games for long periods of time can have a negative effect on normal functioning of the musculoskeletal system, with the possible development of abnormalities. However, computer game exposure in adolescents cannot be decisively identified as a factor causing pathological symptoms, based on the results of this study alone. Thus, longterm longitudinal studies on the overall musculoskeletal system are necessary.

Development of Long-Span Railway Bridges Design Using IPC Girder (IPC 거더를 이용한 장지간 철도교 설계에 관한 연구)

  • Jang, Won-Seok;Park, Jun-Myung;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.149-158
    • /
    • 2003
  • It is customary that tendons and sectional dimensions are calibrated and tendon forces are applied at once at the initial stage to keep the subsequent stresses occuring at different loading stages within the allowable stresse in prestressed concrete (PSC) bridge design. However, this traditional tensioning method usually results in a too conservative sectional depth in view of ultimate capacity of a girder. A new design method which can realize the reduction of sectional depth of PSC girder is theoretically suggested in this study. Tendons are tensioned twice at different loading stages: the initial stage and the stage after fresh slab concrete is cast. It can be shown that according to this technique, sectional depth can be significantly reduced and larger span can be realized compared to traditional ones. In this paper, there is an example about the design of bridge by means of new PSC design theory, having a longer span than a existing railway bridge. Also, a new method by continuous tendon profiles is presented to be continuous a IPC bridge.

Verification of External Magnetization based EM Technique for Diagnosing Residual Tensile Stress in Aged PSC Structures (노후 PSC 구조물의 잔여 긴장 응력 진단을 위한 외부 자화 EM 기법 검증)

  • Soon-Jeon Park;Sehwan Park;Jaehoon Choi;Kyo-Young Jeon;Junkyeong Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.4
    • /
    • pp.251-257
    • /
    • 2023
  • This study entailed an investigation of a tensile stress measurement method for prestressed concrete (PSC) tendons by utilizing external magnetization. The target of this study are PS structures that have been constructed and in use. An optimal external magnetization based elasto-magnetic (EM) sensor was designed using finite element analysis considering various factors, such as coil arrangement and size, that could influence the PS tendons inside the PSC girder. The residual tensile stress resulting from the external magnetization of the girder was then determined. Further, theoretical verification was performed using the numerical and material data used in the finite element analysis for sensor design. The calculated values of strength of magnetization at the target location were matched with the finite element analysis results. Thus, the designed sensor and the feasibility of magnetizing the tendons inside the PSC I-girder using an EM sensor were validated.