• Title/Summary/Keyword: Tendon integrity

Search Result 37, Processing Time 0.023 seconds

Prognostic factors affecting structural integrity after arthroscopic rotator cuff repair: a clinical and histological study

  • Pei Wei Wang;Chris Hyunchul Jo
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.1
    • /
    • pp.10-19
    • /
    • 2023
  • Background: Tendon degeneration contributes to rotator cuff tears; however, its role in postoperative structural integrity is poorly understood. The purpose of this study was to investigate the factors associated with postoperative structural integrity after rotator cuff repair, particularly focusing on the histology of tendons harvested intraoperatively. Methods: A total of 56 patients who underwent primary arthroscopic rotator cuff repair between 2009 and 2011 were analyzed. A 3-mm-diameter sample of supraspinatus tendons was harvested en bloc from each patient after minimal debridement of the torn ends. Tendon degeneration was assessed using seven histological parameters on a semi-quantitative grading scale, and the total degeneration score was calculated. One-year postoperative magnetic resonance imaging was used to classify the patients based on retear. Results: The total degeneration scores in the healed and retear groups were 13.93±2.03 and 14.08±2.23 (P=0.960), respectively. Arthroscopically measured anteroposterior (AP) tear sizes in the healed and retear groups were 24.30±12.35 mm and 36.42±25.23 mm (P=0.026), respectively. Preoperative visual analog scale pain scores at rest in the healed and retear groups were 3.54±2.37 and 5.16±2.16 (P=0.046), respectively. Retraction sizes in the healed and retear groups were 16.02±7.587 mm and 22.33±13.364 mm (P=0.037), respectively. The odds of retear rose by 4.2% for every 1-mm increase in AP tear size (P=0.032). Conclusions: The postoperative structural integrity of the rotator cuff tendon was not affected by tendon degeneration, whereas the arthroscopically measured AP tear size of the rotator cuff tendon was an independent predictor of retear. Level of evidence: III.

Osteogenic Potential of the Periosteum and Periosteal Augmentation for Bone-tunnel Healing

  • Youn Inchan;Suh J-K Francis;Choi Kuiwon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.101-110
    • /
    • 2005
  • Periosteum and periosteum-derived progenitor cells have demonstrated the potential for stimulative applications in repairs of various musculoskeletal tissues. It has been found that the periosteum contains mesenchymal progenitor cells capable of differentiating into either osteoblasts or chondrocytes depending on the culture conditions. Anatomically, the periosteum is a heterogeneous multi-layered membrane, consisting of an inner cambium and an outer fibrous layer. The present study was designed to elucidate the cellular phenotypic characteristics of cambium and fibrous layer cells in vitro, and to assess whether structural integrity of the tendon in the bone tunnel can be improved by periosteal augmentation of the tendon­bone interface. It was found the cells from each layer showed distinct phenotypic characteristics in a primary monolayer culture system. Specifically, the cambium cells demonstrated higher osteogenic characteristics (higher alkaline phosphatase and osteocalcin levels), as compared to the fibrous cells. Also in vivo animal model showed that a periosteal augmentation of a tendon graft could enhance the structural integrity of the tendon-bone interface, when the periosteum is placed between the tendon and bone interface with the cambium layer facing toward the bone. These findings suggest that extra care needs to be taken in order to identify and maintain the intrinsic phenotypes of the heterogeneous cell types within the periosteum. This will improve our understanding of periosteum in applications for musculoskeletal tissue repairs and tissue engineering.

The Usefulness of Ultrasound Diagnosis of Acute Tendon Injury in Hand (급성 건 손상 환자에서 초음파의 유용성)

  • Choi, Chang Yong;Lee, Han Jeong;Choi, Hwan Jun;Kim, Mi Sun
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.729-734
    • /
    • 2008
  • Purpose: The evaluation and management of a completely transected tendon of the hand is relatively clear. In most cases, the integrity is assessed by physical examination(eg, broken normal cascade, motion loss) but occasionally, It happens in troubles. because of pain, limited patient cooperation(eg, child, unconscious patient), and other associated injuries(eg, fractures, foreign bodies). Methods: From september 2006 to August 2007, 28 patients were evaluated with real time ultrasonography preoperatively and postoperatively. Twenty eight patients with injured tendon were evaluated using an HDI 5000 Sono CT(Philips Medical Systems, Bothell, WA) machine with a high resolution, 7.5MHz hockey stick linear probe. Dynamic evaluation was performed in real time. Results: Surgery was performed after the ultrasonographic evaluation. Sonographic diagnosis and intraoperative findings were correlated. Ultrasonographic findings show tendon discontinuity, gaps, and fluid collection. Conclusion: We conclude that ultrasonography is helpful in evaluating and managing acute tendon injury. Especially, in cases of completely lacerated tendon, ultrasonography can identify the location of the proximal tendon stump and partial lacerated tendon, ultrasonographic diagnostic tool can decrease misdiagnosis.

Radiologic and clinical outcomes of an arthroscopic bridging graft for irreparable rotator cuff tears with a modified Mason-Allen stitch using a plantaris tendon autograft: a case series with minimum 2-year outcomes

  • Hyun-Gyu Seok;Sam-Guk Park
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.406-415
    • /
    • 2023
  • Background: Surgical management of a massive rotator cuff tear (RCT) is always challenging. This study describes the clinical and radiological outcomes of patients who underwent bridging grafts using a plantaris tendon for an irreparable RCT. Methods: Thirteen patients with a massive RCT were treated with arthroscopic interposition of a folded plantaris tendon autograft between June 2017 and January 2020. For clinical evaluation, a visual analog scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, Disabilities of the Arm, Shoulder, and Hand (DASH) score, Constant-Murley score, and range of motion values were collected. For radiographic evaluation, standardized magnetic resonance imaging and ultrasonography were performed to check the integrity of the interposed tendon. Results: A statistically significant improvement at the final follow-up was evident in scores for the VAS (-3.0, P=0.003), ASES (24.9, P=0.002), D ASH (-20.6, P=0.001), and Constant-Murley values (14.2, P=0.010). In addition, significant improvement was shown in postoperative flexion (17.3°, P=0.026) and external rotation (27.7°, P<0.001). In postoperative radiologic evaluations, the interposed tendons were intact at the last examination in 12 of the 13 patients. No complications related to donor sites were reported. Conclusions: An arthroscopic bridging graft for irreparable RCTs using a modified Mason-Allen stitch and a plantaris autograft resulted in improved short-term radiological and clinical outcomes. Graft integrity was maintained for up to 2 years in most patients. Level of evidence: IV.

Risk factors of chronic subscapularis tendon tear

  • Hyung Bin Park;Ji Yong Gwark;Jae-Boem Na
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.4
    • /
    • pp.257-264
    • /
    • 2022
  • Background: Chronic subscapularis tendon tear (SBT) is a degenerative disease and a common pathologic cause of shoulder pain. Several potential risk factors for chronic SBT have been reported. Although metabolic abnormalities are common risk factors for degenerative disease, their potential etiological roles in chronic SBT remains unclear. The purpose of this study was to investigate potential risk factors for chronic SBT, with particular attention to metabolic factors. Methods: This study evaluated single shoulders of 939 rural residents. Each subject undertook a questionnaire, physical examinations, blood tests, and simple radiographs and magnetic resonance imaging (MRI) evaluations of bilateral shoulders. Subscapularis tendon integrity was determined by MRI findings based on the thickness of the involved tendons. The association strengths of demographic, physical, social, and radiologic factors, comorbidities, severity of rotator cuff tear (RCT), and serologic parameters for SBT were evaluated using logistic regression analyses. The significance of those analyses was set at p<0.05. Results: The prevalence of SBT was 32.2% (302/939). The prevalence of partial- and full-thickness tears was 23.5% (221/939) and 8.6% (81/939), respectively. The prevalence of isolated SBT was 20.2% (190/939), SBT combined with supraspinatus or infraspinatus tendon tear was 11.9% (112/939). In multivariable logistic regression analysis, dominant side involvement (p<0.001), manual labor (p=0.002), diabetes (p<0.001), metabolic syndrome (p<0.001), retraction degree of Patte tendon (p<0.001), posterosuperior RCT (p=0.010), and biceps tendon injury (p<0.001) were significantly associated with SBT. Conclusions: Metabolic syndrome is a potential risk factor for SBT, as are these factors: overuse activity, diabetes, posterosuperior RCT, increased retraction of posterosuperior rotator cuff tendon, and biceps tendon injury.

Effects of No Stiffness Inside Unbonded Tendon Ducts on the Behavior of Prestressed Concrete Containment Vessels

  • Noh, Sang-Hoon;Kwak, Hyo-Gyong;Jung, Raeyoung
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.805-819
    • /
    • 2016
  • The numerical simulation methodologies to evaluate the structural behaviors of prestressed concrete containment vessels (PCCVs) have been substantially developed in recent decades. However, there remain several issues to be investigated more closely to narrow the gap between test results and numerical simulations. As one of those issues, the effects of no stiffness inside unbonded tendon ducts on the behavior of PCCVs are investigated in this study. Duct holes for prestressing cables' passing are provided inside the containment wall and dome in one to three directions for general PCCVs. The specific stress distribution along the periphery of the prestressing duct hole and the loss of stiffness inside the hole, especially in an unbonded tendon system, are usually neglected in the analysis of PCCVs with the assumption that the duct hole is filled with concrete. However, duct holes are not small enough to be neglected. In this study, the effects of no stiffness inside the unbonded tendon system on the behaviors of PCCVs are evaluated using both analytical and numerical approaches. From the results, the effects of no stiffness in unbonded tendons need to be considered in numerical simulations for PCCVs, especially under internal pressure loading.

Acute Traumatic Medial Dislocation of the Tendon of the Long Head of the Biceps Brachii with Concomitant Subscapularis Rupture - A Case Report - (견갑하근 파열과 동반된 상완 이두근 장두의 외상성 내측 탈구 -1례보고-)

  • Kim Seung Key;Park Jong Beom;Choi Woo-Sung;Kim Ho- Tae;Chang Han
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.154-159
    • /
    • 1998
  • Medial dislocation of the long head of the biceps brachii is a rare condition that usually occurs in association with tears of the subscapularis, chronic impingement, capsular defects or a fracture of the lesser tuberosity. Less commonly, a biceps tendon dislocation may occur after an acute traumatic event. Following a dislocation, the biceps tendon will assume either an intra- or extra-articular position depending on whether or not the subscapularis tendon detaches from its humeral insertion. Magnetic resonance imaging has been found to provide valuable information concerning the location of the biceps tendon and the integrity of the subscapularis tendon. We present a patient with a traumatic dislocation of the biceps brachii tendon in which the diagnosis remained elusive for an extended period of time. In this case, he was evaluated using MRI and reconstruction was performed by restoring the tendon to its anatomical position.

  • PDF

Repair Integrity and Functional Outcomes after Arthroscopic Repair of Transtendinous Full-thickness Rotator Cuff Tears Minimum Two-year Follow-up

  • Kim, Kyung Cheon;Lee, Woo-Yong;Shin, Hyun Dae;Kim, Young-Mo;Han, Sun Cheol
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.183-188
    • /
    • 2017
  • Background: To evaluate the clinical outcomes and associated repair integrity in patients treated with arthroscopic repair for a transtendinous rotator cuff tear followed by resection of the remnant rotator cuff tendon. Methods: Between July 2007 and July 2011, we retrospectively reviewed patients who were treated for transtendinous full-thickness tears in the tendinous portion of the rotator cuff by arthroscopic repair. Clinical outcomes were evaluated using the American Shoulder and Elbow Surgeons (ASES) score, the Shoulder Rating Scale of the University of California at Los Angeles (UCLA), the Constant-Murley score, a visual analogue scale (VAS) pain score, and range of motion (ROM). The repair integrity was determined by magnetic resonance imaging or ultrasonography. Results: There were 19 shoulders with transtendinous full-thickness tears in the tendinous portion of the rotator cuff. The ASES, UCLA, Constant-Murley, and VAS pain scores showed significant improvements in function and symptoms (all p<0.001). The active ROM for forward flexion and abduction was also significantly improved (p=0.002 and p<0.001, respectively). The postoperative radiological examination showed cuff integrity without a re-tear in 68.4% of patients. However, the UCLA, ASES, and Constant-Murley scores were not significantly different between healed and re-torn group (p=0.530, p=0.885, and p=0.262, respectively). Conclusions: Although repair of transtendinous rotator cuff tears followed by resection of the remnant rotator cuff tendon in the footprint has a relatively high re-tear rate, no significant difference was observed in the short-term clinical results between the re-tear and healed groups.

Arthroscopic Repair of Traumatic Subscapularis Tendon Tear (외상성 견갑하건 파열의 관절경하 봉합술)

  • Cho, Su-Hyun;Cho, Hyung-Lae;Ku, Jung-Hoei;Hwang, Tae-Hyok;Park, Man-Jun;Choi, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.3
    • /
    • pp.180-187
    • /
    • 2010
  • Purpose: Rotator cuff tears involving the subscapularis are less common than those involving the superior and posterior rotator cuff. The purpose of the present study was to report the clinical results of repair of isolated traumatic tears of the subscapularis tendon. Materials and Methods: Fifteen patients (13 males, 2 females; mean age 46.2 years; range 35 to 52) with unilateral ruptures of the subscapularis tendon after trauma who underwent arthroscopic repair between February 2003 and October 2008 were reviewed retrospectively. All the cases were isolated tears of the subscapularis without the involvement of any other rotator cuff tendon and were followed for at least two years (mean 28 months). The entire subscapularis was involved in 9 cases and the tear was localized to the upper two thirds in 6 cases. The preoperative and postoperative status of patients with isolated subscapularis tears were analyzed using the Constant Score, American Shoulder and Elbow Society Index (ASES Index) and postoperative integrity was determined through magnetic resonance imaging. Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up. The constant shoulder score improved from 41.5 to 81.3 points (P<0.05) compared to before surgery and ASES index improved from 46.4 to 89.6 points (P<0.05) postoperatively. Thirteen patients (87%) were satisfied with the result of the treatment. The total tears were significantly more improved by surgery than the partial tears. In 12 of 15 patients (80%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 13 months postoperatively. The postoperative score was significantly lower for the patients with a failed repair than it was for those with an intact repair (P<0.05). Conclusion: Repair of traumatic isolated subscapularis tears through arthroscopic techniques effectively restores patient function with regard to pain, mobility, strength and postoperative tendon integrity. The postoperative integrity of the repair correlates with the functional results and the total tears were more improved by surgery than the partial tears, but future studies may be needed.

  • PDF