• Title/Summary/Keyword: Tendon graft

Search Result 141, Processing Time 0.025 seconds

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF

Results of the Reconstruction of Anterior Cruciate Ligament with Freshfrozen Achilles Allograft and of the Second-look Arthroscopy (신선 동결 동종 아킬레스건을 이용한 전방 십자인대 재건술 후 2차 관절경소견)

  • Yoo, Jae-Doo;Kim, Sung-Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.111-116
    • /
    • 2007
  • Purpose: To assess the clinical results of ACL reconstruction with a fresh frozen Achilles allograft, retrospectively and the findings of the graft in second look arthroscopy. Materials and Methods: Twenty-eight ACL reconstructions using fresh frozen Achilles tendon allograft were included in this study between March 1999 and February 2003. The average age was 31.2 years old and the average follow-up was 16.6 months(range: 12-26 months). The clinical evaluation was done by KT-1000 arthrometer, Lysholm knee score, range of motion, Lachman and pivot-shift test. Results: In the last follow-up of Lachman test, 21 cases showed normal, 5 cases grade 1, 2 cases grade 2 and 1 case grade1. The results of pivot-shift test data, 23 cases(82.1%) were normal, 4 cases(14.3%) grade 1, 1 case(3.6%) grade 2. The mean maximum side-to-side difference was improved from 6.75mm preoperatively to 2.46mm in the last follow-up. Lysholm knee score was improved from 73.5 preoperatively to 91.6 in last follow-up. Re-rupture of the ACL graft was found in one case and one case of wound infection in the tibial incision was found. The 6 cases showed the good synovialization of the ACL graft. Conclusion: The anterior stability was restored with ACL reconstruction using fresh frozen Achilles allografts and the good synovialization was found in the second-look arthroscopy

  • PDF

Digital Replantation in Industrial Punch Injuries (천공 펀치 기계에 의한 수지 절단부의 재접합술)

  • Lee, Kyu-Cheol;Lee, Dong-Chul;Kim, Jin-Soo;Ki, Sae-Hwi;Roh, Si-Young;Yang, Jae-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.19 no.1
    • /
    • pp.12-20
    • /
    • 2010
  • Purpose: Industrial punch accidents involving fingers cause segmental injuries to tendons and neurovascular bundles. Although multiple-level segmental amputations are not replanted to regain function, most patients with an amputated finger want to undergo replantation for cosmetic as much as functional reason. The authors describe four cases of digital amputation by an industrial punch that involved the reinstatement of the amputated finger involving a joint and neurovascular bundle. Amputated segments were replanted to restore amputated surfaces and distal segments. Methods: A single institution retrospective review was performed. Inclusion criteria of punch injuries requiring replantation were applied to patients of all demographic background. Injury extent (size, tissue involvement), operative intervention, pre- and postoperative hand function were recorded. Result: Four cases of amputations were treated at our institute from 2004 to 2008 from industrial punch machine injury. Average patient age was 32.5 years (25~39 years) and there were three males and one female. Sizes of amputated segments ranged from $1.0{\times}1.0{\times}1.2\;cm^3$ to $3{\times}1.5{\times}1.6\;cm^3$. Tenorrhaphy was conducted after fixing fractured bone of the amputated segments with K-wire. Proximal and distal arteries and veins were repaired using the through & through method. The average follow-up period was thirteen months (2~26 months), and all replanted cases survived. Osteomyelitis occurred in one case, skin grafting after debridement was performed in two cases. Because joints were damaged in all four cases, active ranges of motion were much limited. However, a secondary tendon graft enhanced digit function in two cases. The two-point discrimination test showed normal values for both static and dynamic tests for three cases and 9 mm and 15 mm by dynamic and static testing, respectively, in one case. Conclusion: Though amputations from industrial punch machines are technically challenging to replant, our experience has shown it to be a valid therapy. In cases involving punch machine injury, if an amputated segment is available, the authors recommend that replantation be considered for preservation of finger length, joint mobility, and overall functional recovery of the hand.

  • PDF

Two to Four Year Follow-Up Results after Anterior Cruciate Ligament Reconstruction Using Transtibial Femoral Tunnel at 10 or 2 O'clock Position (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 후 2~4년 추시 결과)

  • Cho, Sung-Do;Youm, Yoon-Seok;Jeong, Ji-Young;Park, Han-Chang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: To evaluate the 2 to 4-year follow-up results after arthroscopic anterior cruciate ligament (ACL) reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position. Materials and Methods: Eighty-six ACL reconstructions could be evaluated. Evaluations included 2000 International Knee Documentation Committee (IKDC) subjective knee score, Lachman test, Pivot-shift test, KT-1000 arthrometer measurement, 2000 IKDC knee examination and second-look arthroscopy. Results: Seventy-five patients (87.2%) had over 80 in 2000 IKDC subjective knee score. Eighty-three patients (96.5%) had 1+firm end or negative Lachmann test. Seventy-eight patients (90.7%) had a negative Pivot-shift test. Eighty-three patients (96.5%) had less than 5 mm difference by KT-1000 arthrometer. Eighty patients (93.0%) were normal or nearly normal by 2000 IKDC knee examination. Second-look arthroscopy was done in fifteen cases. Nine cases showed good synovialization, four cases showed partial synovialization, two cases showed poor synovialization and graft failure was noted in one case. Conclusion: ACL reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position resulted in a good outcome in terms of rotatory stability as well as antero-posterior stability.

  • PDF

The Reconstruction of Foot using Medial Plantar Flap (내측 족저 피판을 이용한 족부의 재건)

  • Chung, Duke-Whan;Lee, Jae-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.2
    • /
    • pp.153-161
    • /
    • 2002
  • Purpose : Plantar surfaces, calcaneal area, and region of Achilles insertion, which are extremely related with weight-bearing area and shoes application, must be reconstructed with glabrous and strong fibrous skin. Numerous methods of reconstructing defects of these regions have been advocated, but the transfer of similar local tissue as a cutaneous flap with preservation of sensory potential would best serve the functional needs of the weight-bearing and non-weight-bearing surfaces of this region. Therefore it is recommended to use the limited skin of medial surface of foot that is similar to plantar region and non-weight-bearing area. In this paper we performed the medial plantar flap transfered as a fasciocutaneous island as one alterative for moderate-sized defects of the plantar forefoot, plantar heel, and area around the ankle in 25 cases and report the result, availability and problem of medial plantar flap. Materials and methods : We performed proximally based medial plantar flap in 22 cases and reverse flow island flap in 3 cases. Average age was $36.5(4{\sim}70)$ years and female was 3 cases. The causes of soft tissue defect were crushing injury on foot 4 cases, small bony exposure at lower leg 1 case, posterior heel defect with exposure of calcaneus 8 cases, severe sore at heel 2 cases, skin necrosis after trauma on posterior foot 4 cases, and defect on insertion area of Achilles tendon 6cases. Average follow up duration was 1.8(7 months-9.5 years) years. Results: Medial plantar flaps was successful in 22 patients. 18 patients preserved cutaneous branches of medial plantar nerve had sensation on transfered flap but diminished sensation or dysesthesia. At the follow up, we found there were no skin ulceration, recurrence of defect or skin breakdown in all 18 patients. But there was one case which occurred skin ulceration postoperatively among another 4 cases not contained medial plantar nerve. At the last follow up, all patients complained diminished sensation and paresthesia at medial plantar area distally to donor site, expecially with 4 patients having severe pain and discomfort during long-time walking. Conclusion : Medial plantar island flap based on medial plantar neurovascualr pedicle have low failure rate with strong fibrous skin and preserve sensibility of flap, so that it is useful method to reconstruct the skin and soft tissue defect of foot. But it should be emphasized that there are some complications such like pain and paresthesia by neuropraxia or injury of medial plantar nerve at more distal area than donor site. We may consider that medial plantar flap have limited flap size and small arc of rotation, and require skin graft closure of the donor defect and must chose this flap deliberately.

  • PDF

Reconstruction of Electrical Burned Hand by Posterior Tibial Arterial Free Flap (후경골 동맥 유리 피판에 의한 수부 전기 화상의 재건)

  • Choi, Soo-Joong;Seo, Eun Min;Lee, Chang Ju;Chang, Jun Dong;Kim, Suk Wu;Lee, Sang Hun;Lee, Dong Hun;Seo, Young jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.14-23
    • /
    • 2004
  • Introduction: The hand and wrist are particularly susceptible to electrical burn. Skin defect with damage or exposure of underlying vital structure requires coverage by skin flap especially in case of the need for late reconstruction. We are reporting 4 cases of electrical burned hand treated by posterior tibial arterial free flap. The commonly used skin flaps such as scapular flap or groin flap are too bulky so that they are not satisfactory in function and cosmetic appearance. So we tried to cover them with a more thin skin flap. Materials and Method: From January 2002 to June 2003, four cases of hand and wrist electrical burn were covered using posterior tibial arterial free flap. All the cases were due to high voltage electrical burn. Age ranged from 31 years to 38 years old and all the cases were male patients. Recipient sites were 2 wrist, one thenar area and one knuckle of 2.3rd MP joint. Additional procedures were flexor tenolysis (simultaneous), FPL tenolysis and digital nerve graft (later) and extensor tendon reconstruction (later). Result: All the flap have survived totally without any complication including circulatory concern about the donar foot. Posterior tibail arterial free flap was so thin that debulking procedure was not required. Conclusion: For skin coverage of the hand & wrist region, posterior tibial arterial free flap have many advantages such as reliable anatomy, easy dissection and easy anastmosis with radial or ulnar artery and possibility of sensory flap. The most helpful advantage for hand coverage is its thinness. So we think this flap is one of the very useful armamentarium for reconstructive hand surgery.

  • PDF

Reconstruction of Anterior Cruciate Ligament in Adolescent (청소년기에 시행한 전방십자인대 재건술)

  • Song Eun Kyoo;Shim Sang Don;Kim Hyung Jong;Kim Hyung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.101-108
    • /
    • 2002
  • Purpose: To evaluate the clinical results of anterior cruciate ligament (ACL) reconstruction and to know the results of physeal injury by transphyseal tunnel in adolescents who had remaining growth potential. Materials and Methods : This study involved 12 patients under 19 years old out of 445 patients, who underwent ACL reconstruction between 1993 and 2001. The mean age at the time of operation was 15.9 $(13.1\~16.9)$ years and fellow-up period was 45.1 $(24\~120.6)$ months in avrarge. Autologous quadrupled hamstring tendon was used as graft in 11 cases and bone-patellar tendon-bone in 1 case. Clinical results were evaluated by Lysholm Knee Scoring Scale, range of motion and return to preinjury sports activities. Radiologic results were evaluated by $Telos^{\circledR}$ device. Bone maturity were analyzed by chronological age, standing height and the width of growth plate in AP and lateral view of knee joint at preoperatively. The growth disturbances were evaluated by measuring femorotibial angle, anatomical and mechanical lateral distal femoral angle, mechanical medial proximal tibial angle and leg length and by comparing those of uninjured site in last follow-up teleoroentgenogram. Results : The mean Lysholm Knee score was 51 $(25\~63)$points preoperatively and 98 $(94\~100)$ points at last follow up. The mean anterior displacement of the tibia by using $Telos^{\circledR}$ device was improved from 13.5 $(6\~27)$ mm to 2.9 $(1\~4)$ mm and there were no significant instabilities of the knee in all cases. There were no leg length discrepancies over 1 cm and no statistically significant abnormal alignment of the knee joint in all cases. Conclusion: ACL reconstruction using transphyseal tunnel for restoring stability and knee function is assumed as a good mettled of treatment without significant leg length discrepancy and abnormal alignment of the knee joint.

  • PDF

The Effects of Calcium-Phosphate Coated Xenogenic Bone and Type I Collagen for Bone Regeneration on the Calvarial Defects in Rabbits (Ca-P 박막 이종골과 제 1형 교원질이 토끼 두개골 결손부의 골재생에 미치는 영향)

  • Kim, Chang-Han;Park, Jin-Woo;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.223-241
    • /
    • 2004
  • The purpose of this present study evaluated the osseous response around Ca-P coated xenogenic bone and compared osteogenic potential of Ca-P coated xenogenic bone to that of combination with type I collagen derived from bovine tendon as a biocompatible binder to prevent migration of bone particle on the repair of calvarial defects in rabbits. To study the effects of Ca-P coated xenogenic bone and collagen on bone healing, four 5-mm-diameter skull defect were made in calvaria with trephine filled with an autogenous bone chip or Ca-P coated xenogenic bone or Ca-P coated xenogenic bone and type I collagen (1:1 mixture by volume) or left empty. The defects were evaluated histologically at 1, 2, 4 and 8 weeks following implantation. Ca-P coated xenogenic bone at the calvarial defects of rabbits showed osteoconductivity at the margin of defect in the early stage of bony healing, but no direct contact with new bone was observed. With time passed by, it was resorbed slowly and showed consistent inflammatory reaction. An additional use of type I collagen derived from bovine tendon improved clinical handling, but no new bone formation was observed histologically. Above all, autogenous bone graft showed most prominent healing in quantity and density of new bone formation. According to this study, the use of Ca-P coated xenogenic bone alone and combination with type I collagen did not showed effective healing in quantity and density of new bone formation.

New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL (전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기)

  • Ha Chul-Won;Awe Soo-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.195-199
    • /
    • 2002
  • This article is to report a new technique for reconstruction of the anteromedial and posterolateral bundles of anterior cruciate ligament by separate tensioning and fixation of the each bundle. Method : Tibial and femoral tunnels were made with conventional technique of anterior cruciate ligament reconstruction. Tibial tunnel was enlarged $5\~7$ mm in anterior-posterior direction to make oval it in cross section. When preparing the Achilles tendon allograft, bone plug portion was trimmed as the conventional technique. The tendinous portion was trimmed as two separate bundles by dividing the tendinous portion longitudinally, so the graft is shaped like 'Y'. The bone plug portion of allograft was inserted into the femoral tunnel and fixed with absorbable cross pins. Two ligamentous portionss of the distal part of the grafts were tensioned separately at the external orifice. Anteromedial bundle was fastened under maximum tension with the knee flexed 90 degrees by post-tie method. The posterolateral bundle was fixed by the same technique with the knee in full extension. Then, an absorbable interference screw was inserted between the two bundles upto the upper end of the tibial tunnel, to get more initial rigidity of the reconstructed graft as well as to locate the two bundles in more anatomic position.

  • PDF

A Comparison of the Results of BPTB and Hamstring ACL Autograft - Function, Stability & Tunnel Expansion - (골-슬개건-골 및 슬괵건을 이용한 전방 십자 인대 재건술의 비교 - 술후 슬관절의 기능, 안정성 및 대퇴, 경골터널 확장정도에 대하여 -)

  • Jung Young Bok;Tae Suk-Kee;Lim Jung Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • Purpose : The purpose of this study was to compare the results of ACL reconstruction using bone-patellar tendon-bone to hamstring. Materials and Methods : Thirty-two ACL reconstructions with autogenous BPTB and eighteen reconstructions with hamstring were compared in terms of functional outcome, stability and tunnel expansion. Results : The functional score of BPTB group was higher than hamstring group in OAK(Orthopadishe Arbeitsguppe Knie) and IKDC(International Knee Documentation Committee) system. In BPTB group, OAK scores were 71.6$({\pm}10.0)$ preoperatively and 88.5$({\pm}7.9)$ finally. In hamstring group, OAK scores were 73.9$({\pm}11.5)$ and 82.5$({\pm}12.9)$ respectively. There was no difference in stability checked by either $KT-1000^{TM}$ or stress view. Anterior tibial translation measured by $KT-1000^{TM}$ were 2.4$({\pm}1.8)$mm in BPTB and 2.3$({\pm}2.4)$mm in hamstring group. Anterior tibial translation in stress view were 2.8$({\pm}3.4)$mm in BPTB and 2.8$({\pm}2.5)$mm in hamstring group. There was no difference in tibial tunnel expansion but femoral tunnel was more enlarged in hamstring group than BPTB (P=0.03). Conclusion : As there was no difference in stability between two groups, it seems prudent to select either graft defend on such factors as anterior knee pain, skeletal maturity and cosmetic concern. Tunnel expansion seems not to affect stability, but further study is needed to confirm that decrease of which might improve stability.

  • PDF