• 제목/요약/키워드: Tendon

검색결과 1,556건 처리시간 0.027초

Local dynamic characteristics of PZT impedance interface on tendon anchorage under prestress force variation

  • Huynh, Thanh-Canh;Lee, Kwang-Suk;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제15권2호
    • /
    • pp.375-393
    • /
    • 2015
  • In this study, local dynamic characteristics of mountable PZT interfaces are numerically analyzed to verify their feasibility on impedance monitoring of the prestress-loss in tendon anchorage subsystems. Firstly, a prestressed tendon-anchorage system with mountable PZT interfaces is described. Two types of mountable interfaces which are different in geometric and boundary conditions are designed for impedance monitoring in the tendon-anchorage subsystems. Secondly, laboratory experiments are performed to evaluate the impedance monitoring via the two mountable PZT interfaces placed on the tendon-anchorage under the variation of prestress forces. Impedance features such as frequency-shifts and root-mean-square-deviations are quantified for the two PZT interfaces. Finally, local dynamic characteristics of the two PZT interfaces are numerically analyzed to verify their performances on impedance monitoring at the tendon-anchorage system. For the two PZT interfaces, the relationships between structural parameters and local vibration responses are examined by modal sensitivity analyses.

Effect of Carrageenan on the Tendon of Skeletal Muscle of the Rat

  • Hong Gi-Youn;Park Seung-Taeck;Jekal Seung-Joo;Lee Kang-Chang
    • 대한의생명과학회지
    • /
    • 제10권3호
    • /
    • pp.259-262
    • /
    • 2004
  • The aim of present study was to examine the effect of carrageenan on the tendon of skeletal muscle of rat. The tendon damage was induced by injection of carrageenan into skeletal hind muscle of rats. Rats were killed on 48 hours after carrageenan injection. The resulting tendons were fixed with 10% neutral buffered formalin (NBF), dehydrated, embedded, sectioned by 4 μm, and stained by phosphotungstic acid hematoxylin (PTAH) or hematoxylin-eosin (H-E). Carrageenan induced the segregation of tendon fibers, intratendinous cleft, segregation of muscle cell group, wave arrangement of tendon fiber. The results suggest that carrageenan induced tendon damage of rat's skeletal muscle by morphological changes.

  • PDF

Unusual Isolated Complete Tear of Subscapularis and Biceps Long Head Tendon Associated with Heterotopic Ossification

  • Sohn, Hoon-Sang;Baek, Duck In;Shon, Min Soo
    • Clinics in Shoulder and Elbow
    • /
    • 제17권3호
    • /
    • pp.127-133
    • /
    • 2014
  • Heterotopic ossification (HO) within the substance of the subscapularis tendon is a rare lesion which remains a poorly described condition with little known of the exact mechanisms involved. Furthermore, its clinical importance remains still unclear. To our knowledge, there are no studies present to data regarding HO within the substance of the subscapularis tendon, even with resultant isolated complete tear of the subscapularis tendon. Here we present a case of huge HO associated with unusual isolated complete tear of subscapularis tendon concomitant with tear of biceps long head tendon. After arthroscopic debridement for the complete tear site of biceps long head tendon, mini-open excision of the ossification and subscapularis repair with suture anchor fixation were performed. The patient showed complete recovery of strength and function of the subscapularis at subsequent 24 months follow up.

텐던 구동 로봇 메커니즘의 일반화된 그래프 표현 (Generalized Graph Representation of Tendon Driven Robot Mechanism)

  • 조영수;정주노;김두형
    • 로봇학회논문지
    • /
    • 제9권3호
    • /
    • pp.178-184
    • /
    • 2014
  • Tendon driven robot mechanisms have many advantages such as allowing miniaturization and light-weight designs and/or enhancing flexibility in the design of structures. When designing or analyzing tendon driven mechanisms, it is important to determine how the tendons should be connected and whether the designed mechanism is easily controllable. Graph representation is useful to view and analyze such tendon driven mechanisms that are complicatedly interconnected between mechanical elements. In this paper, we propose a method of generalized graph representation that provides us with an intuitive analysis tool not only for tendon driven manipulators, but also various other kinds of mechanical systems which are combined with tendons. This method leads us to easily obtain structure matrix - which is the one of the most important steps in analyzing tendon driven mechanisms.

Deep Vein Thrombosis after Achilles Tendon Repair: A Case Report

  • Jang, Hoseong;Shin, Yong Eun;Kim, Sung Hyun;Park, Hyun-Woo
    • 대한족부족관절학회지
    • /
    • 제20권1호
    • /
    • pp.39-42
    • /
    • 2016
  • Achilles tendon rupture is thought to be increasing with participation in sports activities. Both operative and non-operative treatments of Achilles tendon rupture include a period of immobilization. Complications following treatment of the Achilles tendon rupture include recurrence of rupture, flexor weakness, infection, and wound problems. However, deep vein thrombosis (DVT) after operative treatment of the Achilles tendon has not been reported. We report on a case of DVT after Achilles tendon repair.

FBG 센서를 내장한 스마트 강연선 개발 (Development of Smart Tendon Instrumented with Optical FBG Sensors)

  • 김재민;김영상;김현우;서동남;윤정방
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.33-38
    • /
    • 2007
  • This paper reports an attempt to develop 7-wire steel tendon which is instrumented with optical FBG sensors. The tendon is devised to replace the king cable, which is located in the center of the tendon, by a steel tube in which the FBG sensor are attached along the hole using a high-mobility polyester resin. The circular steel tube has typical of 5 mm outer diameter and 1 mm inner diameter, and can easily be manufactured by means of an pultrusion process. Using the tube, in this study, three different types of one meter-long smart tendons are fabricated depending on mixture ratio of polyester resin and initiator. The performance of the FBG sensors as well as mechanical characteristics of the prototype are tested through the tensile test. Test results shows that the proposed smart tendon is in principle very effective for measuring the working strain of the tendon.

  • PDF

Management of the paralyzed face using temporalis tendon transfer via intraoral and transcutaneous approach Temporalis tendon transfer

  • Choi, Ji Yun;Kim, Hyo Joon;Moon, Seong Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.24.1-24.6
    • /
    • 2018
  • Temporalis tendon transfer is a technique for dynamic facial reanimation. Since its inception, nearly 80 years ago, it has undergone a wealth of innovation to produce the modern operation. Temporalis tendon transfer is a relatively minimally invasive technique for the dynamic reanimation of the paralyzed face. This technique can produce significant and appropriate movement of the lateral oral commissure, more closely mimicking the normal side. The aim of this article is to review the technique of temporalis tendon transfer involving transferring of the coronoid process of the mandible with the insertion of the temporalis tendon via intra-oral and transcutaneous approach.

소아에서 발생한 아킬레스건의 골화증 - 증례보고 - (Ossification of the Achilles tendon in a child - A case report -)

  • 서진수;김진환;주석규
    • 대한족부족관절학회지
    • /
    • 제6권2호
    • /
    • pp.224-228
    • /
    • 2002
  • Ossification of the Achilles tendon is a rare condition to be distinguished from the more frequently occuring tendon calcification. It is characterized by the presence of an ossific mass contained within the fibrocartilaginous substance of the tendon and is usually associated with prior surgery or trauma to the tendon. We treated a 13 year old girl with ossification of the Achilles tendon after sprain-like injury. We excised it one year later and the microscopic finding of the extirpated bony mass revealed fully maturated lamellar bone.

  • PDF

모노 텐던 앵커 헤드의 변형 추정을 위한 수치해석 (Numerical Analysis for the Deformation of a Mono Tendon Anchor Head)

  • 박장호;양현주;조정래
    • 한국안전학회지
    • /
    • 제29권1호
    • /
    • pp.25-30
    • /
    • 2014
  • This paper deals with a numerical study on the deformation of a mono tendon anchor head. The anchor head is used to introduce the compression to concrete, and consists of wedges and a head. All kinematics, material and contact nonlinearity are included in the precise analysis of a mono tendon anchor head. A numerical study on a mono tendon anchor head is performed to investigate effects of friction and eccentricity of load by ABAQUS. From the numerical results, it is verified that the deformation of a mono tendon anchor head is affected by characteristics of materials, boundary condition between wedge and anchor head, eccentricity of load, etc.

Flexor Tendon Rupture Secondary to Gout

  • Jeremy V. Lynn;Amy L. Strong;Kevin C. Chung
    • Archives of Plastic Surgery
    • /
    • 제50권5호
    • /
    • pp.492-495
    • /
    • 2023
  • Extra-articular deposition of monosodium urate crystals is a widely recognized manifestation of gout. However, gouty infiltration of flexor tendons in the hand resulting in tendon rupture is exceedingly rare. This case report highlights a patient with gouty infiltration of flexor tendons in the right middle finger resulting in rupture of both the flexor digitorum profundus and flexor digitorum superficialis. Given the extent of gouty infiltration and need for pulley reconstruction, the patient was treated with two-stage flexor tendon reconstruction. Febuxostat was prescribed preoperatively to limit further deposition of monosodium urate crystals and continued postoperatively to maximize the potential for long-lasting results. Prednisone was prescribed between the first- and second-stage operations to prevent a gout flare while the silicone rod was in place. In summary, tendon rupture secondary to gouty infiltration is the most likely diagnosis in patients with a history of gout presenting with tendon insufficiency.