• Title/Summary/Keyword: Tendon

Search Result 1,580, Processing Time 0.027 seconds

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

Comparative Analysis of Double Bundle and Single Bundle ACL Reconstruction with Tibialis Anterior Allograft (동종건을 이용한 단일다발 및 이중다발 전방십자인대 재건술의 비교 분석)

  • Kim, Deok-Weon;Lee, Kang;Kim, Young-Woo;Yang, Sang-Jin;Seo, Jeong-Gook;Kim, Jin-Goo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.198-204
    • /
    • 2008
  • Purpose: The purpose of this study is to analyze the merits and demerits of double bundle reconstruction and achieve improvements hereafter, by comparing the results of double bundle and single bundle reconstruction using tibialis anterior allograft. Materials and Methods: Twenty seven patients were divided to undergo either double bundle(n=14) or single bundle(n=13) reconstruction with tibialis anterior allograft tendon. The evaluation methods were AP laxity with KT-2000 arthrometer, isokinetic knee strength measurements, pivot-shift test, IKDC subjective score, Lysholm knee score, Tegner activity score, radiographic evaluations with postoperative MRI, and second look arthroscopy. Results: Lysholm knee score and Tegner activity score were significantly better in double bundle reconstruction. In pivot-shift test, single bundle reconstruction was evaluated as grade 0 in 10 of the knees, grade 1 in 1, and grade 2 in 2. Double bundle reconstruction was evaluated as grade 0 in 13, and grade 2 in 1. In second look arthroscopy, single bundle was evaluated as excellent in 6 of the knees, fair in 7, anteromedial bundle of double bundle reconstruction was excellent in 13 and fair in 1, and posterolateral bundle was excellent in 4, fair in 9, and poor in 1. There were no significant differences in other evaluations. Conclusion: Favorable outcome may be expected with double bundle reconstruction of ACL. However there are still need for improvement in terms of reconstruction technique and rehabilitation protocol to reduce PL bundle injury.

  • PDF

Clinical Outcomes of Minimum 12-Month Follow-Up of Anatomical Double Bundle ACL Reconstruction with a Longitudinally Split Tibialis Anterior Allograft (종분할된 전경골 동종건을 이용한 해부학적 전방 십자 인대 이중다발 재건술의 최소 12개월 임상 결과)

  • Seo, Young-Jin;Song, Si Young;Kim, In Sung;Ahn, Jung Tae;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.99-107
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the clinical results after a anatomical double bundle ACL reconstruction using a longitudinally split tibialis anterior allograft. Materials and Methods: We evaluated 24 patients with a minimum follow-up of 12 months who had undergone anatomical double bundle ACL reconstructions. The grafts utilized in all cases were tibialis anterior allografts which were longitudinally split into two strands. A standard rehabilitation protocol was applied in all patients. The pre- and post-operative data including Lysholm scores, International Knee Documentation Committee (IKDC) scores, Lachman test, pivot shift test and the side-to-side differences of anterior laxity measured by KT-2000 arthrometer were analyzed by use of a statistical method Results: The mean side-to-side instrumented laxity measured by the KT-2000 arthrometer significantly improved to a mean of $1.04{\pm}0.80\;mm$ (P < 0.001). The Lysholm knee scores also improved from $58.34{\pm}15.32$ to $86.25{\pm}6.48$ after surgery (P < 0.001). The patients exhibited improved IKDC scores (A: 15 cases, B; 9 cases) at the final follow-up, compared to preoperative scores (B: 5, C: 10, D: 9). Conclusion: Our data demonstrated that clinical results of anatomical double bundle ACL reconstruction with a split tibialis anterior allograft are encouraging with excellent side-to side laxity, significantly improved Lysholm knee score, IKDC score, Lachman and pivot shift data.

  • PDF

Results of the Reconstruction of Anterior Cruciate Ligament with Freshfrozen Achilles Allograft and of the Second-look Arthroscopy (신선 동결 동종 아킬레스건을 이용한 전방 십자인대 재건술 후 2차 관절경소견)

  • Yoo, Jae-Doo;Kim, Sung-Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.111-116
    • /
    • 2007
  • Purpose: To assess the clinical results of ACL reconstruction with a fresh frozen Achilles allograft, retrospectively and the findings of the graft in second look arthroscopy. Materials and Methods: Twenty-eight ACL reconstructions using fresh frozen Achilles tendon allograft were included in this study between March 1999 and February 2003. The average age was 31.2 years old and the average follow-up was 16.6 months(range: 12-26 months). The clinical evaluation was done by KT-1000 arthrometer, Lysholm knee score, range of motion, Lachman and pivot-shift test. Results: In the last follow-up of Lachman test, 21 cases showed normal, 5 cases grade 1, 2 cases grade 2 and 1 case grade1. The results of pivot-shift test data, 23 cases(82.1%) were normal, 4 cases(14.3%) grade 1, 1 case(3.6%) grade 2. The mean maximum side-to-side difference was improved from 6.75mm preoperatively to 2.46mm in the last follow-up. Lysholm knee score was improved from 73.5 preoperatively to 91.6 in last follow-up. Re-rupture of the ACL graft was found in one case and one case of wound infection in the tibial incision was found. The 6 cases showed the good synovialization of the ACL graft. Conclusion: The anterior stability was restored with ACL reconstruction using fresh frozen Achilles allografts and the good synovialization was found in the second-look arthroscopy

  • PDF

Influence of Korean Red Ginseng Water Extract on Recovery of Hepatic Function in Hypercholesterolemic Mice Fed High Cholesterol Diet (홍삼물추출물이 고콜레스테롤 식이로 유도된 고콜레스테롤 혈증에서 간 기능 회복에 미치는 영향)

  • Song, Yong-Bum;Kyung, Jong-Soo;Park, Sung-Bum;Wee, Jae-Joon;Do, Jae-Ho;Kim, Young-Sook
    • Journal of Ginseng Research
    • /
    • v.32 no.4
    • /
    • pp.283-290
    • /
    • 2008
  • Hypercholesterolemia is associated with many pathological states such as fat deposit in the tendon and skin, hepatomegaly, pancreatitis and heart attack. The present study was focused on the effect of Korean red ginseng water extract (RGWE) on the recovery of hepatic function that was deteriorated in high-cholesterol diet fed mice. Mice were divided into 6 groups ; normal diet group (AIN-2WK), 4 week-high-cholesterol diet group (CHOL-4WK), 2 week-high-cholesterol + 2 week-normal diet group (CHOL-2WK), 2 week-high-cholesterol + 2 week-normal diet + RGWE treated group (R100, R300, R500). RGWE treated group received normal diet and RGWE at daily doses of 100, 300, 500 mg/kg b.w. for 2 weeks after the 2 weeks feeding of high-cholesterol diet. The results are as follows : 1. The hepatic weight and total hepatic lipid weight were markedly lower in RGWE treated group than those in the CHOL-4WK or CHOL-2WK group, indicating that ginseng inhibited hepatic hypertrophy. 2. Total hepatic cholesterol and HDL-cholesterol in normal diet conversion group (CHOL-2WK) were significantly reduced compared with the high cholesterol group (CHOL-4WK). The lowering effect was significantly reinforced by RGWE administration. 3. Hepatic triglyceride level of CHOL-4WK group was markedly lower than that of the normal group (AIN-2WK). However, the level was significantly increased in CHOL-2WK and RGWE treated group. The result indicated that ginseng administration and diet conversion exert normalizing effects of hepatic function. 4. The lipid peroxide levels in RGWE treated groups were markedly lower than CHOL-2WK group. These results suggest that Korean red ginseng water extract can be useful as a dietary supplement for the treatment of obesity or hypercholesterolemia by improving lipid metabolism and hepatic function.

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

Arthroscoic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Gratt - Effect of the Additional Fixation after Fixation of the Graft with Intrafix - (자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 - INTRAFIX system을 이용한 경골부 고정 후 부가적 고정의 효과 -)

  • Yoo, Jae-Doo;Roh, Kwon-Jae;Shin, Sang-Jin;Yoon, Jong-Suk;Yeo, Sung-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.51-55
    • /
    • 2005
  • Purpose: To compare the stability and clinical result after anterior cruciate ligament reconstructed knee after graft fixation using Intrafix in tibial tunnel with or without additional tibial post fixation. Materials and Methods: We analyzed 37 cases which were treated with four-strand hamstring tendon autograft during the period from May 2002 to January 2003. The grafts were fixed with Rigidfix system (Mitek Product, Johnson and Johnson, USA) in femur tunnel and Intrafix system (Mitek Product, Johnson and Johnson, USA) in tibial tunnel. After tibial fixation, additional tibial post fixation was done, which was determined by the serial case number prospectively. Patients were followed for average of fourteen months(range, thirteen to twenty-five months) At the time of final follow-up, patients were evaluated in terms of Lachman test, pivot shift test, Lysholm scores, IKDC (International Knee Documentation Committee) assessment, side-to-side KT-1000 maximum-manual arthrometer differences. Results: At last follow-up, Lysholm score was average 93.1(range: 65 to 98), IKDC assessment revealed that 26 cases had score of A, 10 cases had score of B and 1 case had score of C. The average maximum-manual KT-1000 arthrometer side ?to-side difference was 2.5 mm$(0{\sim}6mm)$. There was one case in which the Lachman test was graded as 2+ and four cases in which the Lachman test was graded as 1+ and the remaining thirty-two cases were normal by Lachman test. One case had a 2+ pivot-shift, and 2 cases had a 11 pivot-shift. The remaining 34 knees were normal on pivot -shift testing. The average maximum-manual KT-1000 arthrometer side-to-side difference was average 2.8 mm$(0{\sim}6mm)$ in Intrafix only group and average 2.2 mm$(0{\sim}4mm)$ in additional fixation group (P>0.05). Conclusion: Without additional tibial fixation, the stability of the anterior cruciate reconstructed knee with hamstring graft which was fixed with Intrafix was restored.

  • PDF

Clinical Results of ACL Reconstruction in the Immature Adolescent via Transphyseal Approach in Tibia Based on a New Indication Paradigm (새로운 수술적응증에 의한 골 미성숙 전방십자인대 손상 환자에서의 성장판을 통과하는 전방십자인대 재건술의 결과)

  • Lee, Dong Chul;Shon, Oog Jin;Park, Chul-Hyun;Kwon, Moon Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose: To evaluate clinical and radiologic outcomes of transphyseal anterior cruciate ligament (ACL) reconstruction in patients with open physes who were selected with authors' new operative indications. Materials and Methods: We evaluated 15 patients with open physes who underwent a transtibial ACL reconstruction and were followed up for 4~6 years after surgery. Our operative indications involved 1) choronologic age of ${\geq}$ 16 in male and ${\geq}$ 14 in female, 2) open physes of ${\leq}$ 2 mm width, and 3) Risser sign and Tanner stage of ${\geq}$ 3. Tibialis anterior tendon allograft was used in all patients, and endobutton and bioscrew were used for femoral and tibial fixations, respectively. Functional outcomes were evaluated using Lysholm Knee Scoring scale, Tegner activity scale, and International Knee Documentation Committee (IKDC) 2000 subjective score. Physical examinations to evaluate stability involved Lachman and pivot shift tests. For radiographic results, we evaluated side to side differences of anterior displacement in stress views. In addition, with use of scannograms taken at last follow-up, we examined side to side differences of femorotibial angles, anatomical and mechanical lateral distal femoral angles, mechanical medial proximal tibial angles and leg lengths. Results: The mean Lysholm Knee score was 51(40-61) points preoperatively and 97(94-100) points at last follow up. The mean Tegner activity score was 2.6 points preoperatively and 7.1 points at last follow up. The mean IKDC score was 32.6 points preoperatively and 88.3 points at last follow up. The mean anterior displacement of the tibia was improved from 6.7(${\pm}1.0$) mm to 1.9(${\pm}0.9$) mm. There were no leg length discrepancies over 5 mm and no statistically significant differences in all the radiographic variables representing growth disturbance. Conclusion: This study suggests that patients with open physes who selected by authors' new indication would safely undergo transphyseal ACL reconstruction with successful outcomes.

  • PDF

The Clinical Results of ACL Reconstruction with Tibialis Allograft Using Hybrid Femoral Fixation and $Retroscrew^{(R)}$ (Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 사용한 동종 경골건 이용 전방 십자 인대 재건술의 임상적 결과)

  • Kim, Doo-Sub;Rah, Jung-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.8-13
    • /
    • 2009
  • Purpose: We used tibialis allograft for the reconstruction of ACL and used Hybrid femoral fixation utilizing $Endobutton^{(R)}$ and $Rigidfix^{(R)}$ for femoral fixation, and used $Retroscrew^{(R)}$ and additional fixation for tibial fixation to evaluate the clinical results. Materials and Methods: The ACL reconstruction were performed from February 2004 to February 2007 utilizing Hybrid femoral fixation and $Retroscrew^{(R)}$ and 32 patients, 32 cases which were available for year-long observation (12 to 25 months). The clinical results (Lysholm knee score, IKDC grade) and the radiologic results(bone tunnel expansion, Telos anterior displacement test) were evaluated. Results: The Lysholm knee score was improved from the average of $67.9{\pm}5.4$ points (range: 51~77) before operation and to $94.1{\pm}6.8$ points (range: 68~98) at the last follow up (p<0.05). 22 cases (69%) were evaluated normal (A), 9 cases (28%) were evaluated nearly normal (B) and only 1 case (3%) was evaluated not normal (C) at IKDC final evaluation and no case was evaluated abnormal. From $Telos^{(R)}$ stress x-ray evaluation, difference from the opposite knee was improved average 13.2 mm{\pm}5.8 (range: 6~21 mm) to average $3.4\;mm{\pm}2.8$ (range: 0~11 mm) after operation (p<0.05). The femoral and tibial tunnel were widened by 18.7% and 9.6% in the AP view and 12.4% and 8.5% in the lateral view, respectively (p<0.05). However, any statistic significance was not observed between bone tunnel expansion and knee joint functions (p>0.05). Conclusion: An ACL reconstruction with tibialis allograft using Hybrid femoral fixation and $Retroscrew^{(R)}$ enabled anatomical fixation of the graft tendon with satisfactory clinical results.

  • PDF

Short-term Follow up Study of Calcific Tendinitis Using Ultrasonography Guided Injection (석회화 건염에 대한 외래 초음파 유도 주사 치료요법의 단기추시결과)

  • Sim, Jung-Hyun;Kwon, Jae-Bum;Park, Chang-Min;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.77-83
    • /
    • 2011
  • Purpose: We compared with USG-guided steroid injection group and blind steroid injection group for the treatment of calcific tendinitis to evaluate the effectiveness of the treatment modalities. Materials and Methods: We reviewed two groups of calcific tendinitis treated with steroid injection and follow up upto 6 month after injection. Group I was blind injection for 88 patient with average age of 53years old and female gender in 77%. Group II was USG- guided injection for 102 patients with average age of 54years old and female gender in 85%. We compared follow up results according to age, gender, size of tendon involvement, initial VAS score, and phase of the calcific tendinitis between two groups. Results: At 6 month's follow up period, USG-guided injected group was more prevalent compared to blind injection group with 92%(94/102) and 72%(64/88) (P<0.05). In Group I, 77%(49/64) patients have improved symptom. And in Group II, 92%(86/94) patients have improved symptom in formative or resorptive phase. Despite of symptom improvement, calcium deposit is remained 47%(30/64) in Group I, and 20%(19/94) in Group II. Conclusion: Conservative treatment of Shoulder calcific tendinitis patients through USG-guided injection is more effective than Blind injection in pain relief & calcium decrease. The patients USG-guided injected group was more prevalent in follow up at outpatient clinic, throughout more accurate injection with improved confidence.

  • PDF