• Title/Summary/Keyword: Temperature transmission

Search Result 1,623, Processing Time 0.031 seconds

A Study on the Telemetric Measuring System of the Underwater Information (수중정보의 원격계측시스템에 관한 연구)

  • 신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.7-11
    • /
    • 1988
  • This Paper describes technique for the design of system for telemetering the water temperature at sea. This telemetering device adopts FM-FM system, and its main carrier wave is 146.2MHz. The transmission power is about 1W, and the available distance of transmission is 2km. The telemetering time for the transmission and pause is controlled automatically by the CMOS programmable timer. The water temperature is measured by the electronic thermometer, it is varied by V-F converter which is built to a linear voltage controlled oscillator. The results of the experiment at the place where the receiver is off 2km from the transmitter, the water temperature measured with the mercury thermometer well agree with that of the telemetering device.

  • PDF

Characterization and Enhancement of Package O2 Barrier against Oxidative Deterioration of Powdered Infant Formula

  • Jo, Min Gyeong;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.1
    • /
    • pp.13-16
    • /
    • 2018
  • Powdered infant formula is susceptible to oxidation in the presence of oxygen. Even though the product is usually packaged in nitrogen atmosphere, the oxygen ingress through the package layer may occur in case of flexible pouches and affects the oxidation of the product. $O_2$ barrier of the package is thus important variable to protect the product from oxidative deterioration. $O_2$ barrier property was investigated for aluminum-laminated small pillow packs of $3.5{\times}17.5cm$. Storage temperature and combination of primary and secondary packages were evaluated as variables affecting the barrier for conditions of empty pouch flushed with nitrogen. Apparent oxygen transmission rate of the primary package exposed to air was $2.32{\times}10^{-3}mL\;(STP)\;atm^{-1}\;d^{-1}$ at $30^{\circ}C$ and its temperature dependence could be explained by activation energy of $28.5kJ\;mol^{-1}$ in Arrhenius relationship. The additional secondary package of nylon/PE film containing 20 primary packages was ineffective in modulating package $O_2$ transmission and was only marginally helpful when combined with oxygen scavenger. The same was true in suppressing the product oxidation when the primary package was filled with 14 g of the formula.

An Experimental Study on Heat Transmission Characteristics of the Conventional and Prefabricated Ondol (기존온수온돌과 조립식 온수온돌의 전열특성에 관한 실험적 연구)

  • Min, J.H.;Lee, C.G.;Jang, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.611-621
    • /
    • 1995
  • The objectives of this study are to find out and to analyze the heat transmission characteristics of the conventional and prefabricated Ondol systems. To compare the thermal characteristics of these Ondol, a real sized Ondol model is set in a chamber. Hot water whose temperature is varied from $45^{\circ}C$ to $60^{\circ}C$ with $5^{\circ}C$ interval is supplied to each Ondol system. At that time the temperature distribution of floor surface, the amount of supplied heat, the heat radiation aspect and the heat loss from the floor to the underground are measured and analyzed simultaneously. As a result, even if the supplied hot water temperature to the prefabricated Ondol panel is lower by about $5^{\circ}C$ than that of the conventional Ondol panel, the net radiant effect is same. Heat radiation efficiency of the prefabricated Ondol panel is over 5% better than that of the conventional Ondol panel. It takes 12 hours for the conventional Ondol and 45 minutes for the prefabricated Ondol, respectively to reach steady state.

  • PDF

CORRECTION METHOD OF ESTIMATED INSERTION-LOSS WITH FLOW

  • Nishimura, Tsuyoshi;Usagawa, Tsuyoshi;Ebata, Masanao
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.746-751
    • /
    • 1994
  • The four-terminal transmission matrix method has been widely used to estimate the insertion-loss. However, the predictins using the equations in the four-terminal transmission matrix method do not reflect a practical phenomenon accurately, In this paper, the correction method to derive the insertion-loss for a constant sound pressure source is presented. The method of correction to the four-terminal transmission matrix method was proposed by rewriting the real and imaginary parts as they depend solely on the flow velocity. Then the result was compensated for by adding the component of the temperature gradient.

  • PDF

Structural and Morphological Changes of Co Nanoparticles and Au-10at.%Pd Thin Film Studied by in Situ Heating in a Transmission Electron Microscope

  • Ji, Yoon-Beom;Park, Hyun Soon
    • Applied Microscopy
    • /
    • v.47 no.3
    • /
    • pp.208-213
    • /
    • 2017
  • The microstructural changes in Co nanoparticles and an Au-10at.%Pd thin film have been investigated using an in situ heating holder with a micro-electro-mechanical system (MEMS). In Co nanoparticles, two phases (face-centered cubic and hexagonal close-packed crystal structures) were found to coexist at room temperature and microstructures at temperatures, higher than $1,000^{\circ}C$, were observed with a quick response time and significant stability. The actual temperature of each specimen was directly estimated from the changes in the lattice spacing (Bragg-peak separation). For the Au-10at.%Pd thin film, at a set temperature of $680^{\circ}C$, the actual temperature of the sample was estimated to be $1,020^{\circ}C{\pm}123^{\circ}C$. Note that the specimen temperature should be carefully evaluated because of the undesired effects, i.e., the temperature non-uniformity due to the sample design of the MEMS chip, and distortion due to thermal expansion.

Chromatic Dispersion Compensation via Mid-span Spectral Inversion with Periodically Poled $LiNbO_3$ Wavelength Converter at Low Pump Power

  • Kim, Min-Su;Ahn, Joon-Tae;Kim, Jong-Bae;Ju, Jung-Jin;Lee, Myung-Hyun
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.312-318
    • /
    • 2005
  • Mid-span spectral inversion (MSSI) has to utilize high optical pump power, for its operation principle is based on a nonlinear optical wavelength conversion. In this paper, a low pump-power operation of MSSI-based chromatic dispersion compensation (CDC) has been achieved successfully, for the first time to our knowledge, by introducing a noise pre-reduction scheme in cascaded wavelength conversions with periodically poled $LiNbO_3$ waveguides at a relatively low operation temperature. As preliminary studies, phase-matching properties and operation-temperature dependence of the wavelength converter (WC) were characterized. The WC pumped at 1549 nm exhibited a wide conversion bandwidth of 59 nm covering the entire C-band and a conversion efficiency of -23.6 dB at 11 dBm pump power. CDC experiments were implemented with 2.5 and 10 Gb/s transmission systems over 100 km single-mode fiber. Although it is well-known that the signal distortion due to chromatic dispersion is not critical at a 2.5 Gb/s transmission, the clear recovery of eye patterns was identified. At 10 Gb/s transmission experiments, eye patterns were retrieved distinctly from seriously distorted ones, and notable improvements in bit-error rates were acquired at a low pump power of 14 dBm.

  • PDF

Characteristics of Contact resistivity on RTP annealing temperature and time after Plasma ion implant (플라즈마 이온주입 후 RTP 열처리 온도와 시간에 따른 접촉저항 특성)

  • Choi, Jang-Hun;Do, Seung-Woo;Lee, Yong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.5-6
    • /
    • 2009
  • In this paper, plasma ion implant is performed with $PH_3$ gas diluted by helium gas on P-type Si wafer (100). Spike Rapid Thermal Processing(RTP) annealing performed for 30~60 sec from $800\;^{\circ}C$ to $1000\;^{\circ}C$ in $N_2+O_2$ ambient. Crystalline defect is analyzed by Transmission Electron Microscope(TEM) and Double crystal X-ray Diffraction(DXRD). Contact resistivity($\rho c$), contact resistance(Rc) and sheet resistance(Rs) are analyzed by measuring Transfer Length Method(TLM) using 4155C analysis. As annealing temperature increase, Rs decrease and ${\rho}c$ and Rc increase at temperature higher than $850\;^{\circ}C$. We achieve low Rs, ${\rho}c$ and Rc with Plasma ion implant and spike RTP.

  • PDF

Assessment of Particulate Matters from an Exhaust Gas for Conventional and Low Temperature Diesel Combustion in a Compression Ignition Engine (압축 착화 엔진에서 기존 및 저온 디젤 연소에서 발생하는 배기가스의 입자상 물질에 관한 특성 비교)

  • Jung, Yongjin;Shin, Hyun Dong;Bae, Choongsik
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.183-186
    • /
    • 2012
  • The characteristics of particulate matters (PM) from an exhaust gas for conventional and low temperature diesel combustion (LTC) in a compression ignition engine was experimentally investigated by the elemental, thermogravimetric analysis. Morphology of PM was also studied by the transmission electron microscopy. PM for LTC shows that it contains more volatile hydrocarbons, which can be easily evaporated than conventional regime. PM for LTC is comprised of smaller primary particles.

  • PDF

Effects of Magnetic Characteristics on Coefficient of Thermal Expansion in Fe-Ni-Co-C Invar Alloy for Transmission Line (송전선 강심용 Fe-Ni-Co-C 합금의 열팽창계수에 미치는 자기적 특석의 영향)

  • Kim, Bong-Seo;Kim, Byung-Geol;Lee, Hee-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1346-1348
    • /
    • 2001
  • Generally, Invar alloy shows very low thermal expansion characteristics, lower than $2{\times}10^{-6}$/K approximately. To apply Fe-Ni-Co-C Invar alloy as a core material for large ampacity transmission line we studied the effects of magnetic properties on coefficient of thermal expansion. The coefficient of thermal expansion(CTE) suddenly decreases with addition of a little carbon(0.08%), increases with the increasing carbon and has a constant value at the composition over than 1.0%C. The trend of Curie temperature change with carbon is similar with that of CTE. Therefore, the CTE has a linear relationship with Curie temperature. However, the CTE linearly decreases with the ratio of saturation magnetization and Curie temperature(${\sigma}_s/T_c$).

  • PDF

Analysis of Distribution Power System with Thermal Conductor Distribution Lines (내열 도체가 적용된 가공 배전선의 적용 영향에 관한 연구)

  • Kim, Myong-Hyon;Lee, Kyone-Tae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.243-244
    • /
    • 2015
  • Power system has been improved during for a long time by customers demand. Power suppliers has researched the power system component for more electricity transmission. One of the research is apply the thermal conductors in new cable. The operational temperature of thermal conductors is higher than normal aluminum that thermal conductor is composed of aluminum, Zr(zirconium) and etc. Increase of operational temperature is growth of the transmission capability. Power suppliers was concerned about the increase of operation temperature by thermal conductors. Therefore, the thermal conductor has the possibility that expanded application in power system. In this paper analysed effect of thermal conductor in power distribution system.

  • PDF