• Title/Summary/Keyword: Temperature test equipment

Search Result 329, Processing Time 0.025 seconds

Breakdown Properties of Cryogenic Coolant for Pancake Coil Type High $T_{c}$ Superconducting Equipment (Pancake coil형 고온초전도 기기의 응용을 위한 극저온 냉매의 절연파괴 특성)

  • 백승명;정종만;이진호;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.185-188
    • /
    • 2002
  • In the design of superconducting power equipments such as transformer, cable and fault current limit, knowledge of the dielectric behavior of both liquid and gaseous at very low temperatures is very importance. Especially, Electrical properties of liquid nitrogen($LN_{2}$) and gaseous nitrogen($GN_{2}$) have become of great interest again since the discovery of high temperature superconductors. However, many sources of $LN_{2}$and $GN_{2}$ problems in the test of pancake coil model arising form the deficiency of insulation data. Therefore, this paper describes the results of an experimental study on the ac breakdown voltage($V_{B}$) properties of $LN_2$ and Air under the electrode of simulated HTS pancake coil. The ac breakdown voltage of $GN_{2}$ have been measured by pancake coil-pancake coil gaps over the temperature range of 293 K to 77 K.

  • PDF

Gate Leakage Current Characteristics of GaAs MESFETS′ with different Temperature (GaAs MESFET의 온도변화에 다른 게이트 누설전류 특성)

  • 원창섭;김시한;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.50-53
    • /
    • 2001
  • In this study, gate leakage current mechanism has been analyzed for GaAs MESFET with different temperatures ranging from 27$^{\circ}C$ to 300$^{\circ}C$ . It is expected that the thermionic and field emission at the MS contact will dominate the current flow. Thermal cycle is applied to test the reliability of the device. From the results, it is proved that thermal stress gradually increases the gate leakage current at the same bias conditions and leads to the breakdown and failure mechanism which is critical in the field equipment. Finally the gate contact under the repeated thermal shock has been tested to check the quality of Schottky barrier and the current will be expressed in the analytical from to associate with the electrical characteristics of the device.

  • PDF

Study for Synthetic Oil Performance Test Comparing with Mineral Gear oil in an Agitator Gear Box:Power consumption, Temperature, Oil & parts life for the Heavy load gear box in the Phosphoric Acid Plant (뉴스초점 - 광유와 합성유의 에너지 소비량, 온도변화 등의 성능시험 비교 고찰)

  • Lee, Jae Keun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.45 no.6
    • /
    • pp.28-32
    • /
    • 2012
  • Namhae chemical is one of the largest fertilizer manufacturing company in Korea which company has operating 4 unit agitator gear boxes and producing variety kinds of fertilizer production. The gearbox operating temperature of agitator is approximated in $55^{\circ}C{\sim}90^{\circ}C$ and required to keep operating continuous without stopping. The system required high performance oil and longer oil drain interval as limited workforce in maintenance team. It was lubricated by mineral gear oil of ISO VG 320 and also need to change to new oil frequently. Namhae Chemical would expect to keep stable operating condition without shut down and consider, lower cost of operation and equipment protection.

  • PDF

A Study on Performance Degradation Analysis of Gas Turbine Combined Heat and Power Plant (가스터빈 열병합발전소 성능저하 분석에 관한 연구)

  • Kim, Hong Joo;Kim, Byeong Heon;Oh, Byeong Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.248-255
    • /
    • 2016
  • In this study, the degree of performance changes between the guaranteed performance and the performance after a certain operating start time is calculated by using the performance test of gas turbine CHP. The reason of the performance degradation will then be analysed. For some results of the CHP plant performance tests the comprehensive electric power output was 8,380 kW lower than the guaranteed performance, and the gas turbine's output was reduced to about 250 kW whenever ambient temperatures rose to $1^{\circ}C$. Also, causes of the performance degradation of gas turbines are ambient temperature rise, temperature aging and air compressor's efficiency drop.

A Study on Design of the Temperature Testing Equipment Malfunction Monitoring System (온도시험 장비 오류 감시 시스템 설계에 관한 연구)

  • Yoon, Myung-Seob;Park, Koo-Rack
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.435-436
    • /
    • 2019
  • 본 논문에서는 첨단 정밀 전자장치의 신뢰성 시험을 위해 사용하는 온도시험 장비의 오동작이 발생이 되면, 시험담당자에게 문자메시지를 통해 현재 시험장비가 오동작 중임을 알릴 수 있는 시스템을 제안한다. 제안시스템은 기존에 오픈 소스를 이용한 시험장비의 오동작 여부를 모니터를 하는 시스템에 시험담당자에게 이 사실을 SMS로 전달하는 시스템을 추가한 것이다. 정밀 전자장치는 출고전에 온도시험 장비를 사용하여 설정한 저온, 고온 온도 상황에서 각각 정상적으로 장치가 동작하는지의 여부를 확인하게 된다. 만약 이 상황하에서 온도 시험장비가 설정한 저온의 온도 이하 혹은 설정한 고온의 온도 이상 등의 오동작이 발생되면, 수억원에 이르는 고가의 시험대상 제품이 손상을 입어 폐기하는 경우가 생긴다. 제안한 시스템은 시험 운용자가 자리를 비우는 야간에 특히 유용한 시스템으로서 온도시험장비와 별도의 전원을 사용하여 그 신뢰성을 높이는 장점을 가진다.

  • PDF

The Effect of Changes in Polymerization Conditions of Orthodontic Acrylic Resin on Maximum Load (Orthodontic Acrylic Resin의 중합조건 변화가 최대하중에 미치는 영향)

  • Lee, Gyu Sun
    • Journal of Technologic Dentistry
    • /
    • v.35 no.2
    • /
    • pp.127-136
    • /
    • 2013
  • Purpose: In order to find out the impact of changes in polymerization conditions of orthodontic acrylic resin on maximum load. Methods: While maintaining mixing ratio 3:1 of polymer and monomer in spray-on way in the production condition of polymerization temperature $25^{\circ}C$ or $37^{\circ}C$ for 10 minutes or 30 minutes of polymerization time by pressure $3kfg/cm^2$ or $6kfg/cm^2$ in the lab maintaining $25^{\circ}C$ of room temperature, the change in maximum load rise rate was tested by producing 5 acrylic resin specimens for orthodontics per group to meet the standards of $25mm{\times}2mm{\times}2mm$ and using INSTRON with the 3rd bar 2mm in diameter and parallel support bending device of $15{\pm}0.1mm$ as test equipment showing 30.00mm/min of crosshead speed, $50{\pm}16$ N/min of load ratio in the laboratory of $24^{\circ}C$ room temperature and as a result, the following results were obtained. Results: 1. When increasing pressure from $3kfg/cm^2$ to $6kfg/cm^2$, maximum load was lowered by -4.285%. 2. When increasing polymerization time from 10 minutes to 30 minutes, maximum load rose by 3.848%. 3. When increasing polymerization temperature from $27^{\circ}C$ to $37^{\circ}C$, maximum load rose by 5.854%. Conclusion: Considering the above test results that polymerization time and polymerization temperature when polymerizing acrylic resin for orthodontics according to changes in working conditions had an impact on the rate of rise of maximum load values but the rate of rise was lowered when increasing pressure from $3kfg/cm^2$ to $6kfg/cm^2$, we came to a conclusion that high pressure more than necessary does not affect the rate of rise of maximum load.

An analysis of the Wi-Ni Carbide Alloy Diffusion Bonding technique in its application for DME Engine Fuel Pump

  • Chun, Dong-Joon
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.246-251
    • /
    • 2020
  • Dimethyl Ether(DME) engine use a highly efficient alternative fuel having a great quantity of oxygen and has a advantage no polluting PM gas. The existing DME fuel cam material is a highly expensive carbide alloy, and it is difficult to take a price advantage. Therefore the study of replacing body area with inexpensive steel material excluding piston shoe and contact area which demands high characteristics is needed. The development of WC-Ni base carbide alloy optimal bonding composition technique was accomplished in this study. To check out the influence of bonding temperature and time, bonding characteristics of sintering temperature was experimented. The hardness of specimen and bonding rate were measured using ultrasound equipment. The bonding state of each condition was excellent, and the thickness of mid-layer, temperature and maintaining time were measured. The mid-layer thickness according to bonding temperature and maintaining time were observed with optical microscope. We analyzed the micro-structural analysis, formation of bonding specimen, wafer fabrication and fuel cam abrasion test. Throughout this study, we confirmed that the fuel cam for DME engine which demands high durability against velocity and pressure is excellent.

Server Room Temperature Condition in Data Center with Cold Aisle Containment System (냉복도 밀폐시스템을 적용한 서버실의 실내온도조건)

  • Jung, Yong-Ho;Chang, Hyun-Jae;Seo, Jang-Hoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.79-84
    • /
    • 2013
  • In this study, a cold aisle containment system was proposed among various strategies to reduce the energy waste by recirculation air from the hot aisle. To verify the effectiveness of the cold aisle containment system, a test bed which is similar to an actually existing server room was set up in the Internet Data Center(IDC) building. Comparative experiments, conventional open type cooling system and cold aisle containment system were carried out under actual conditions. The result revealed that the range of inlet temperature of the server system was $20{\sim}25^{\circ}C$ in an existing cooling system and the range of inlet temperature dropped below $20^{\circ}C$ by the cold aisle containment system. After all, cold aisle containment system was proved to be the solution for energy saving cooling system.

Evaluation for Moisture Susceptibility of Asphalt Mixtures using Non-Destructive Impact Wave (비파괴 충격파를 이용한 아스팔트 공시체의 수분민감도 평가)

  • Jang, Byung Kwan;Kim, Do Wan;Mun, Sung Ho;Jang, Yeong Sun
    • International Journal of Highway Engineering
    • /
    • v.15 no.3
    • /
    • pp.53-63
    • /
    • 2013
  • PURPOSES : This study is to evaluate moisture susceptibility of asphalt mixtures by using non-destructive impact wave and to determine durability so as to decrease the gap between before and after freezing in the future. METHODS : Using non-destructive impact wave, this study is to determine the dynamic modulus of asphalt specimen. Furthermore, the results obtained from two experiment accelerometers are used for the dynamic modulus determination. The dynamic moduli of specimens are compared with those of the freezing-thawing specimens. RESULTS : Test results showed that the dynamic modulus before freezing and thawing environment loads at each temperature dropped about 3.7% after the environmental loads. Furthermore, correlation analysis indicates that transition of dynamic modulus at each point is about 89.59%. CONCLUSIONS: Evaluation of asphalt mixtures using non-destructive impact wave has excellent repeatability and simple equipment for the test. Consequently, the method in the study will be useful for evaluating the characteristics of a various asphalt mixtures.

Conjugated Heat Transfer Analysis of Electric Heater (전기식 히터 복합 열유동 해석)

  • Shim, Chang-Yeul;Park, Soon-Sang;Han, Poong-Gyoo;Kim, Young-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.973-976
    • /
    • 2011
  • In this paper, the conjugated heat transfer anslysis was performed about an electric heater used in a combustion test equipment of a combustor engine to figure out a physical phenomenon that heater coil was periodically cut during heating test. The result of analysis is that the temperature of coil at coil inlet region was increased locally because the velocity of air was slow in that region. The coil of heater was moved to 25mm downstream so that the structure stability of coil was assured by the decrease of the coil temperature due to increase of an air velocity.

  • PDF