• 제목/요약/키워드: Temperature of aggregate

검색결과 361건 처리시간 0.026초

Manufacturing lightweight aggregate uses high content of sewage sludge for non-structural concrete

  • Phung Trong-Quyen;Kim, Duck-Mo;Mun, Kyoung-Ju;Soh, Yang-Seob
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.124-127
    • /
    • 2003
  • Sewage sludge and clay used as raw materials in the study. Green aggregates contain different contents by dried weight of the sewage sludge, up to 80 percent is manufactured and burning conditions of soak temperature, soak time and rate of temperature increase. influence of burning condition and mixing ratio on specific gravity of burned aggregate are discussed. The appropriate burning condition to all aggregates is evaluated. Aggregates result form the thermal treatment get specific gravity under 0.8, water absorption fewer than 7.5 percent, and aggregate crushing value from 28 to 53. As the result, aggregates can be available as the lightweight aggregate for non-structural concrete.

  • PDF

잔골재의 종류에 따른 초속경콘크리트의 특성에 관한 연구 (A Study on the Characteristics of Rapid-set concrete as to Fine aggregate Kinds)

  • 정해동;강의주;이환우;장희석;김명식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.417-422
    • /
    • 2001
  • The purpose of this study is to investigate experimentally the workability, compressive and flexural strength properties of rapid-set concrete with various mixture. The kinds of fine aggregate(river sand, sea sand, crushed sand), water-cement ratio(40%, 45%, 50%), sand-aggrega to ratio(33%, 36%, 39%) were chosen as the experimental parameters. Test variables are temperature of concrete, slump, air contents, compressive and flexural strength. The compressive and flexural strength for 3 hours and 6 hours were tested. As result, it was shown that temperature of concrete involved 45$^{\circ}C$, some time later decreased. The workability were decreasing in steps as the sand-aggregate ratio increased and crushed sand was the highest value. Higher compressive and flexural strength was shown following the order of river sand, sea sand, crushed sand regardless of sand-aggregate ratio. But the values of gap was just a little.

  • PDF

초기 재령 콘크리트의 종파 속도와 강도의 상관관계 (Correlation between Longitudinal Wave Velocity and Strength of Early-aged Concrete)

  • 이휘근;이광명;김동수
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.67-74
    • /
    • 2000
  • The usage of nondestructive testing on early-aged concrete leads to enhacned safty and allows effective scheduling of construction, thus making it possible to maximize the time and cost efficiencies. In this study, a reliable nondestructive strength evaluation method for early-aged concrete using the longitudinal wave velocity is proposed. Compression tests were performed to examine factors influencing the velocity-strength relationship of concrete, such as water-cement (w/c) ratio, fine aggregate ratio, curing temperature, and curing condition. The test results show that a change in the w/c ratio and curing temperature has minor effect on the velocity-strength relationship/ However, curing condition significantly influences the velocity-strength relationship of early-aged concrete. Moreover, the longitudinal wave velocity increases with decreasing fine aggregate ratio. It is concluded from this study that the strength evaluation of early-age concrete can be achieved by a nonlinear equation which considers the effects of curing condition and fine aggregate ratio.

양생온도에 따른 다공성 경량골재를 활용한 샌드위치 패널심재의 강도 특성 (Strength Properties of Sandwich Panel core using Cellular lightweight Aggregate according to Curing Temperature)

  • 노정식;김대규;도정윤;문경주;소양섭
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.35-38
    • /
    • 2003
  • The purpose of this study is to investigate the manufacture of light weight concrete panel using the artificial light-weight aggregate as a part of the substitution of foamed styrene and polyurethane because of narrow allocable temperature Bone in use. The experimental parameter of this study is 40, 60 and 8$0^{\circ}C$ of curing temperature at 100% relative humidity and the type of admixture such as cement, 6mm glass fiber and St/BA emulsion. Testing item is compressive and flexural strength and strength of specimen cured at standard condition is compared to that of specimen cured at 40, 60 and 8$0^{\circ}C$ of curing temperature at 100% relative humidity. As a result or this, it was revealed that the maximum or strength is developed in 6$0^{\circ}C$ or cure temperature at 100% relative humidity in case of the most of the specimen. Specimens modified by St/BA emulsion show the highest development of strength dependent on the curing tmeperature. So, it seems to be effective that evaporation curing method shoud be considered to curing the specimen as the panel core.

  • PDF

800℃ 조건에서의 시멘트 경화체의 균열 특성 (Cracking Behavior of Cement and Concrete Damaged by High Temperature of 800℃)

  • 지우람;박지웅;신기돈;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.26-27
    • /
    • 2017
  • In this study, the cracking characteristics of cured pastes at 800℃ were investigated by X-ray CT. The test specimens were fabricated with and without aggregate, and the heating rate condition was applied at rapid heating (10.0℃/min). It is considered that the rapid heating condition does not cause a temperature gradient phenomenon because the temperature difference between the surface and the center of the sample is small due to a low heating rate unlike an actual fire. The cracking condition of the specimens without aggregate was more severe than that of specimens with aggregate.

  • PDF

골재 혼입 유무에 따른 고온 수열 콘크리트의 압축강도와 B3B 휨강도 상관성 검토 (A review of the correlation between the compressive strength and B3B flexural strength of high-temperature hydrothermal concrete with or without aggregate mixture)

  • 권현우;임창민;김민혁;김영민;이건철;허영선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.89-90
    • /
    • 2022
  • In this study, the correlation between the compressive strength and the B3B bending strength of the high-temperature hydrothermal concrete according to the presence or absence of aggregate incorporation was examined. As a result of the experiment, as the heating temperature increases, the strength decreases and shows a high correlation.

  • PDF

Recovery of mortar-aggregate interface of fire-damaged concrete after post-fire curing

  • Li, Lang;Zhang, Hong;Dong, Jiangfeng;Zhang, Hongen;Jia, Pu;Wang, Qingyuan;Liu, Yongjie
    • Computers and Concrete
    • /
    • 제24권3호
    • /
    • pp.249-258
    • /
    • 2019
  • In order to investigate the strength recovery of fire-damaged concrete after post-fire curing, concrete specimens were heating at $2^{\circ}C/min$ or $5^{\circ}C/min$ to 400, 600 and $800^{\circ}C$, and these exposed specimens were soaked in the water for 24 hours and following by 29-day post-fire curing. The compressive strength and split tensile strength of the high-temperature-exposed specimens before and after post-fire curing were tested. The proportion of split aggregate in the split surfaces was analyzed to evaluate the mortar-aggregate interfacial strength. After the post-fire curing process, the split tensile strength of specimens exposed to all temperatures was recovered significantly, while the recovery of compressive strength was only obvious within the specimens exposed to $600^{\circ}C$. The tensile strength is more sensitive to the mortar-aggregate interfacial cracks, which caused that the split tensile strength decreased more after high-temperature exposure and recovery more after post-fire curing than the compressive strength. The mortar-aggregate interfacial strength also showed remarkable recovery after post-fire curing, and it contributed to the recovery of split tensile strength.

고온 및 냉각조건에 따른 콘크리트의 역학적특성에 관한 실험적 연구 (An Experimental Study on the Mechanical Properties of Concrete with High Temperatures and Cooling Conditions)

  • 김규용;강연우;이태규;최경철;윤민호
    • 한국건축시공학회지
    • /
    • 제12권3호
    • /
    • pp.323-331
    • /
    • 2012
  • 1970년대부터 고온을 받은 콘크리트의 압축강도, 탄성계수, 열응력 등 콘크리트에 영향을 미칠 수 있는 내적, 외적 인자들의 역학적 특성은 조사되어 왔다. 특히, 골재의 열적 특성이나 냉각 방법은 잔존 역학적 특성을 평가하는데 가장 중요하다. 본 연구에서는, 골재 종류와 냉각 방식에 따른 콘크리트의 역학적 특성에 대해 평가했다. 본 연구에서는 열적특성이 다른 일반 골재와 경량골재를 사용했다. 또한, ${\O}100{\times}200mm$ 원주형 공시체를 사용하여 목표 온도, 서냉 및 급냉조건 후에 역학적 특성을 평가하였다. 결과적으로, 보통 골재를 사용한 콘크리트는 경량골재를 사용한 콘크리트보다 냉각조건이 미치는 영향이 큰 것으로 나타났다. 그리고 냉각 속도가 빠르지 않을수록 콘크리트의 잔존 역학적 특성이 크게 나타났다.

플라이애시와 유리 발포 경량골재를 사용한 내화 마감모르타르의 특성 (Properties of Fire Resistant Finishing Mortar Using Fly Ash and Glass Forming Light Weight Aggregate)

  • 송훈
    • 한국건설순환자원학회논문집
    • /
    • 제3권4호
    • /
    • pp.374-381
    • /
    • 2015
  • 화재에 대한 건축물의 내화성능 확보를 위해서는 온도가 상승하더라도 허용범위 이내로 제어하고 탈락이나 손상 등이 발생하지 않아야 한다. 이에 대한 대책으로 부재 외면에 내화모르타르로 마감을 하는 것이 가장 효율적인 방법이다. 내화 마감모르타르는 고온에서 강도변화가 작고 열적으로 안정하며 열전도율이 낮은 경량재료라면 효과적으로 성능발현이 가능할 것이다. 본 연구는 내화 마감모르타르 개발을 위한 연구로 비교적 내화성능이 우수한 플라이애시 및 메타카올린 기반의 알칼리 활성화 결합재와 펄라이트 및 유리 발포 경량골재의 고온 특성에 대해 검토하였다. 실험결과 열전도율이 낮고 고온에서 비교적 안정적인 특성을 발현하여 내화 마감모르타르로 적용이 가능할 것으로 판단된다.

광산란과 입자포집을 이용한 동축류 확산화염 내의 실리카 입자의 성장 측정(I) - 화염온도의 영향 - (An Experimental Study of Silica Particle Growth in a Coflow Diffusion Flame Utilizing Light Scattering and Local Sampling Technique (I) - Effects of Flame Temperature -)

  • 조재걸;이정훈;김현우;최만수
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1139-1150
    • /
    • 1999
  • The evolution of silica aggregate particles in coflow diffusion flames has been studied experimentally using light scattering and thermophoretic sampling techniques. The measurements of scattering cross section from $90^{\circ}$ light scattering have been utilized to calculate the aggregate number density and volume fraction using with combination of measuring the particle size and morphology through the localized sampling and a TEM image analysis. Aggregate or particle number densities and volume fractions were calculated using Rayleigh-Debye-Gans and Mie theory for fractal aggregates and spherical particles, respectively. Of particular interests are the effects of flame temperature on the evolution of silica aggregate particles. As the flow rate of $H_2$ increases, the primary particle diameters of silica aggregates have been first decreased, but, further increase of $H_2$ flow rate causes the diameter of primary particles to increase and for sufficiently larger flow rates, the fractal aggregates finally become spherical particles. The variation of primary particle size along the upward jet centerline and the effect of burner configuration have also been studied.