• Title/Summary/Keyword: Temperature independent

Search Result 1,009, Processing Time 0.034 seconds

Experimental Analysis of Boil-Off Gas Occurrence in Independent Liquefied Gas Storage Tank (독립형 액화가스 저장탱크의 BOG 발생에 대한 실험적 분석)

  • Cha, Seung-Joo;Bae, Jin-Ho;Lee, Dong-Ha;Kim, Tae-Wook;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.380-385
    • /
    • 2018
  • With the tightening of environmental regulations (i.e., IMO Tier III), natural gas (NG) has been spotlighted as an eco-friendly fuel with few air pollutants other than nitrogen oxides (NOx) and sulfur oxides (SOx). For reasons of economic efficiency, it is mainly stored and transported in a liquid state at $-163^{\circ}C$, which is a cryogenic temperature, using a liquefied gas storage tank. Accordingly, it is necessary to reduce the boil-off gas (BOG) occurrence due to the heat flow according to the temperature difference between the inside and outside of the storage tank. Therefore, in this study, a BOG measurement test on an independent-type storage tank made up of SUS304L was carried out. The test results showed the tendency for BOG occurrence according to the temperature under different filling ratios.

Effects of Onion Powder and Baking Temperature on the Physicochemical Properties of Cookies

  • Kim, Hye-Ran;Seog, Eun-Ju;Lee, Jun-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.12 no.3
    • /
    • pp.160-166
    • /
    • 2007
  • Response surface methodology (RSM) was used for the optimization of the baking process of cookies made with onion powders (onion cookie). Experiments were carried out according to a central composite design, selecting onion powder content $(1.15{\sim}8.86%)$ and baking temperature $(155.9{\sim}184.1^{\circ}C)$ as independent variables and pH, titratable acidity, moisture content, density, spread factor, CIE color parameters $(L^{\ast}-$, $a^{\ast}-$, and $b^{\ast}-values)$, and hardness as response variables. pH decreased with increasing amount of onion powder and baking temperature. Moisture content also decreased as the baking temperature increased. $L^{\ast}-$ and $b^{\ast}-values$ decreased but $a^{\ast}-values$ increased with increasing onion content and baking temperature. Most polynomial models developed by RSM were highly effective to describe the relationships between the studied factors and the responses. Overall optimization, conducted by overlaying the contour plots under investigation, was able to point out the optimal range of the independent variables within which the six responses were simultaneously optimized. The point chosen as representative of this optimal region corresponded to 4.01% onion powder content and $161.84^{\circ}C$ baking temperature. The predicted dependent or response values in the optimal region were: pH=6.87, moisture content=2.77%, $L^{\ast}-value=68.45$, $a^{\ast}-value=1.98$, $b^{\ast}-value=34.64$, and spread factor=9.41.

A Study on the Physical Properties of xB2O3-yBi2O3-zPbO-5SiO2 Glass System (xB2O3 -yBi2O3-zPbO-5SiO2계 유리의 전기적인 특성)

  • Joung, Maeng Sig;Ju, Kyung Bok;Lee, Nam Han
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.111-117
    • /
    • 2001
  • The temperature dependence of dielectric constant and electrical conductivity for the BBPS glasses system was studied over a temperature range between $30^{\circ}C$ and $500^{\circ}C$ and at a frequency ranged from $10^3$ Hz to $10^7$ Hz. The dielectric constant ${\varepsilon}$ at room temperature of $xB_2O_3-yBi_2O_3-zPbO-5SiO_2 $ glasses was measured to be 15 at $10^5$ Hz for all samples and found to be almost frequency independent. At the relatively low temperature ranger (<$70^{\circ}C$), the dielectric constant was almost temperature independent and above that it increased with increasing temperature: the rate of increase being different at different frequencies. This behavior could be explained on the basis of the presence of molecular dipoles. The dielectric constant was found to depend on the composition as well as the crystalline phases formed in the glass matrix.

  • PDF

EHL Analysis of connecting Rod Bearings Considering Effects of Temperature Variation (온도 변화의 영향을 고려한 커넥팅 로드 베어링의 EHL 해석)

  • 김병직;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.114-120
    • /
    • 2000
  • EHL analysis of connecting rod bearing is proposed which includes effects of temperature variation in lubrication film. Lubrication film temperature is treated as a time-dependent, two-dimensional variable which is averaged over the film thickness, while connecting rod big end temperature is assumed to be time-independent and three-dimensional. It is assumed that a portion of the heat generated by viscous dissipation in the lubrication Him is absorbed by the film itself, and the remainder flows into the bearing surface. Mass-conserving cavitation algorithm is applied and the effect of variable viscosity is included to solve the Reynolds equation. Simulation results of the connecting rod bearing of internal combustion engine are presented. It is shown that the temperature variation has remarkable effects on the bearing performance. It is concluded that the EHL analysis considering effects of the temperature variation is strongly recommended to predict the bearing performance of connecting rod big end On internal combustion engine.

  • PDF

Thermal Strain and Temperature Measurements of Structures by Using Fiber-Optic Sensors (광섬유 센서를 이용한 구조물의 열변형 및 온도 측정)

  • 강동훈;강현규;류치영;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.184-189
    • /
    • 2000
  • Two types of fiber-optic sensors, EFPI(extrinsic Fabry-Perot interferometer) and FBG(fiber Bragg grating), have been investigated for measurement of thermal strain and temperature. The EFPI sensor is only for measurement of thermal strain and the FBG sensor is for simultaneous measurement of thermal strain and temperature. FBG temperature sensor was developed to measure strain-independent temperature. This sensor configuration consists of a single-fiber Bragg grating and capillary tube which makes it isolated from external strain. This sensor can then be used to compensate for the temperature cross sensitivity of a FBG strain sensor. These sensors are demonstrated by embedding them into a graphite/epoxy composite plate and by attaching them on aluminum rod and unsymmetric graphitelepoxy composite plate. All the tests were conducted in a thermal chamber with the temperature range $20-100^{\circ}C$. Results of strain measurements by fiber-optic sensors are compared with that from conventional resistive foil gauge attached on the surface.

  • PDF

Thermal post-buckling analysis of a laminated composite beam

  • Akbas, Seref D.
    • Structural Engineering and Mechanics
    • /
    • v.67 no.4
    • /
    • pp.337-346
    • /
    • 2018
  • The purpose of this study is to investigate thermal post-buckling analysis of a laminated composite beam subjected under uniform temperature rising with temperature dependent physical properties. The beam is pinned at both ends and immovable ends. Under temperature rising, thermal buckling and post-buckling phenomena occurs with immovable ends of the beam. In the nonlinear kinematic model of the post-buckling problem, total Lagrangian approach is used in conjunction with the Timoshenko beam theory. Also, material properties of the laminated composite beam are temperature dependent: that is the coefficients of the governing equations are not constant. In the solution of the nonlinear problem, incremental displacement-based finite element method is used with Newton-Raphson iteration method. The effects of the fibber orientation angles, the stacking sequence of laminates and temperature rising on the post-buckling deflections, configurations and critical buckling temperatures of the composite laminated beam are illustrated and discussed in the numerical results. Also, the differences between temperature dependent and independent physical properties are investigated for post-buckling responses of laminated composite beams.

EHL Analysis of Connecting Rod Bearings Considering Effects of Temperature Variation (온도 변화의 영향을 고려한 커넥팅 로드 베어링의 EHL 해석)

  • 김병직;김경웅
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.228-235
    • /
    • 2001
  • EHL analysis of connecting rod bearing is proposed which includes effects of temperature variation in lubrication film. Lubrication film temperature is treated as a time-dependent, two-dimensional variable which is averaged over the film thickness, while connecting rod big end temperature is assumed to be time-independent and three-dimensional. It is assumed that a portion of the heat generated by viscous dissipation in the lubrication film is absorbed by the film itself, and the remainder flows into the bearing surface. Mass-conserving cavitation algorithm is applied and the effect of variable viscosity is included to solve the Reynolds equation. Simulation results of the connecting rod bearing in internal combustion engine are presented. It is shown that the temperature variation has remarkable effects on the bearing performance. It is concluded that the EHL analysis considering effects of the temperature variation is strongly recommended to predict the connecting rod bearing performance in internal combustion engine.

The Effect of Thermal Properties on Temperature Development of Concrete (열적성질을 고려한 콘크리트의 수화발열특성에 관한 연구)

  • Shon, Myung-Soo;Park, Yon-Dong;Kim, Hoon;Kim, Ho-Young;Lee, Yang-Soo;Kang, Suck-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.97-102
    • /
    • 1997
  • In this study, a predictive method which was modified from KIshi's model for the temperature development of concrete was developed by using mineral compounds of clinker and pozzolans. Temperature dependent heat generation of reaction was also considered. Specific heat considering the effect of mix proportion and temperature was calculated with experimental data in the literatures. Thermal conductivity considering the effect of mix proportion and temperature was experimentally investigated. Through this research it was found that the developed method considering thermal properties accurately predicted adiabatic temperature rise of concrete without the experiment. It was also found that the thermal conductivity of concrete could be predicted by the volume ratio of each component of mix proportion and was independent of temperature within the normal climatic range.

  • PDF

Sensibility Classification Algorithm of EEGs using Multi-template Method (다중 템플릿 방법을 이용한 뇌파의 감성 분류 알고리즘)

  • Kim Dong-Jun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.12
    • /
    • pp.834-838
    • /
    • 2004
  • This paper proposes an algorithm for EEG pattern classification using the Multi-template method, which is a kind of speaker adaptation method for speech signal processing. 10-channel EEG signals are collected in various environments. The linear prediction coefficients of the EEGs are extracted as the feature parameter of human sensibility. The human sensibility classification algorithm is developed using neural networks. Using EEGs of comfortable or uncomfortable seats, the proposed algorithm showed about 75% of classification performance in subject-independent test. In the tests using EEG signals according to room temperature and humidity variations, the proposed algorithm showed good performance in tracking of pleasantness changes and the subject-independent tests produced similar performances with subject-dependent ones.

Simulation of the hot water ONDOL heating system by response factor method (應答係數法에 의한 溫水 溫室 暖房 시스템의 Simulation)

  • 조상준;민만기;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.3
    • /
    • pp.409-424
    • /
    • 1987
  • Simulation on the hot water ONDOL heating system was made in order to investigate the variation of room temperature and specific fuel consumption of boiler. Heat balance equation was derived by response factors and solved implicitly. Variation of room temperature and specific fuel consumption of boiler were calculated with respect to the thickness of room floor, the absorptivity of wall for solar radiation, on-off temperature range of boiler and air exchange. The results show that specific fuel consumption of boiler is independent of the thickness of room floor and decreases with increasing the absorptivity of wall and on-off temperature range of boiler. However, it increases with increasing the air exchange. They also show that, when the absorptivity and on-off temperature range of boiler are increased, the amplitudes of room temperature variation increase.