• Title/Summary/Keyword: Temperature imaging

Search Result 687, Processing Time 0.025 seconds

Imaging and Manipulation of Benzene Molecules on Si Surfaces Using a Variable-low Temperature Scanning Tunneling Microscope

  • Hahn, J. R.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.7
    • /
    • pp.1071-1074
    • /
    • 2005
  • A variable-low temperature scanning tunneling microscope (VT-STM), which operates from 77 to 350 K in ultrahigh vacuum, was built and used to study imaging and manipulation of benzene molecules on Si surfaces. Four types of benzene adsorption structures were first imaged on the Si(5 5 12)-2x1 surface. Desorption process of benzene molecules by tunneling electrons was studied on the Si(001)-2xn surface.

Effect of Aceclofenac on the Skeletal Muscle (Aceclofenac이 골격근 형태에 미치는 효과)

  • Song, Myung-Soo;Kim, Tea-Yeal;Yoon, Hee-Jong;Jang, Ki-Yen
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.597-605
    • /
    • 2000
  • There has been several usual ways to cure pain in osteological muscle: use oral medicine or injection, or apply medicine to a sore place. The purpose of this study was to examine, by using thermometer and digital infrared thermographic imaging, how much the permeation of aceclofenac, an anodyne and antiphlogistic, into sore skin brought a change to skin temperature after that was' applied to it. The findings of this study were as below; 1. A cream made of aceclofenac yielded $0.61^{\circ}C$ difference in temperature, but the difference wasn't statistically significant. 2. An aceclofenac to which oleic acid was added went through microemulsion and applied, and there was $0.3^{\circ}C$ change in temperature, the biggest significant difference(P<.05), after approximately 15 minutes passed. 3. An aceclofenac to which labrasol was added went through microemulsion and applied, and there was a growing rise in temperature with the lapse of time. After 30 minutes passed, the final temperature showed $1.25^{\circ}C$ rise, which was a significant change(P<.05). 4. As the temperature was measured by digital infrared thermographic imaging, there was about $3.97^{\circ}C$ fall, the biggest change, which was significant(P<.05). The findings of this study suggested that the application of aceclofenac to sore skin caused a change in skin temperature, as that permeated into it.

  • PDF

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

Analysis The Intensity of Weathering of The Rock Surface Using 3D Terrestrial Laser Scanner and Thermal Infrared Instrument (열적외선 기기와 3차원 레이저 스캐너를 이용한 암석 표면의 풍화강도 분석)

  • Lee, Soo-Gon;Cho, Hang-Kyo;Xu, Jing
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1324-1333
    • /
    • 2010
  • This paper is used in a recent civil engineering field in three-dimensional laser-meter tiles using thermal imaging cameras for the weathered rock slopes precisely measured indirectly, to the degree that began in the will. In the field is difficult to access the degree of weathering of the rock slope to the existing direct way to compensate for the shortcomings of 3D Terrestrial Laser Scanner and weathering characteristics of rocks using thermal imaging cameras to get the information to analyze the degree of rock weathering is. Intensity of 3D TLS and the thermal camera with image analysis to analyze the degree of weathering of bedrock in the field of core drilling targeting indoor laboratory tests were analyzed through the study. Granite, gneiss, sandstone, much of the cancerous samples, each experiment has a 40 per category, each of which 30 were used to analyze the data collected. That degree of rock weathering, the rock, depending on the strength of the Intensity values can change, depending on the level of thermal imaging camera, also weathered the changes in temperature could see. Intensity is the strength of weak rocks, the more value decrease, the temperature of the thermal imaging camera through the swell Intensity and notice that the temperature had an inverse relationship. Intensity value of the low strength of weak rock, but the value came out of the rocks have been proved to be largely dependent on the contrast. The contrast of the surface rocks are weathered dark Intensity values lower temperature to swell the contrary, the degree of weathering can be distinguished.

  • PDF

Microwave and RF Heating for Medical Application under Noninvasive Temperature Measurement Using Magnetic Resonance

  • Nikawa, Yoshio;Ishikawa, Akira
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.244-249
    • /
    • 2010
  • Recent development of magnetic resonance imaging (MRI) equipment enables interventional radiology (IVR) as diagnosis and treatment under MRI usage. In this paper, a new methodology for magnetic resonance (MR) scanner to apply not only diagnostic equipment but for treatment one is discussed. The temperature measuring procedure under MR is to measure phase shift of $T_1$, which is the longitudinal relaxation time of proton, for the position inside a sample material with the application of pulsed RF for heating inside the sample as artificial dielectrics. The result shows the possibility to apply MR as temperature measuring equipment and as a heating equipment for applying such as hyperthermia heating modality.

Automatic Intelligent Asymmetry Detection Using Digital Infrared Imaging with K-Means Clustering

  • Kim, Kwang Baek;Song, Doo Hoen
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.180-185
    • /
    • 2015
  • Digital infrared thermal imaging is a non-invasive adjunctive diagnostic technique that allows an examiner to visualize and quantify changes in skin surface temperature. The asymmetry of temperature differences between the diseased and the contralateral healthy body parts can be automatically analyzed and has been studied in many areas of medical science. In this paper, we propose a method for intelligent automatic asymmetry detection based on a K-means analysis and a YCbCr color model. The implemented software successfully visualizes an asymmetric distribution of colors with respect to the patients’ health status.

Effect of Injection Pressure on the Flash Boiling Spray from Simple Orifice Nozzle (인젝터 압력이 단공노즐 감압비등 분무에 미치는 영향)

  • Lee, Hyunchang;Cha, Hyunwoo;Kang, Donghyeon
    • Journal of ILASS-Korea
    • /
    • v.27 no.1
    • /
    • pp.42-49
    • /
    • 2022
  • Flash boiling occurs in a couple of modern engineering systems and understanding its mechanism is important. In this experimental study, discharge coefficient of flash boiling spray from simple orifice nozzle was measured, and backlight imaging was acquired at injection pressure to 6.0 bar and temperature to 163℃ for the purpose. Pressurized water by pump was used for working fluid and was heated by electric heater and ejected through simple orifice nozzle diameter of 0.5 mm. High speed camera with long distance microscope was used for backlight imaging in two FoV having magnification of 3.3 and 0.64. The decrease of discharge coefficient according to degree of superheating and evolution of flash boiling spray imaged at various pressure and temperature were explained by the pressure field inside the injector.

THE BASIC PRINCIPLES AND TECHNICAL TRENDS OF THERMAL IMAGING SYSTEMS (적외선 열 영상장비의 기본원리 및 기술동향)

  • Hong, S.M.;Song, I.S.;Kwon, W.K.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1255-1259
    • /
    • 1992
  • All matter above absolute zero emits thermal energy. Thermal imaging system converts the infrared radiation of a scene into a live picture of that scene : the thermal image is a pictorial representation of temperature differences. This paper has outlined the principles of thermal imaging and has briefly reviewed the history, and the present day and future technology.

  • PDF

Advances in High TG Hole Transporters

  • Gelsen, Olaf;Lischewski, V.;Leonhardt, J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.355-356
    • /
    • 2006
  • The glass transition behavior of OLED materials is very important for both processing and lifetime. We report about the correlation between the structure of selected small molecule Hole Transport Materials (HTM's) and their glass transition temperature. The thermal stability of devices manufactured with them was investigated. The results give researchers and engineers some information which are helpful for designing new molecules and processing them in device making.

  • PDF

Standardization Study of Thermal Imaging using the Acupoints in Human Body (적외선 체열 영상의 표준화 연구 부위별 대표 혈위를 중심으로)

  • Choi, Young-Chon;Lim, Chung-San;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.113-122
    • /
    • 2008
  • Objective: The purpose of this study was to invigorate the use of infrared thermal imaging apparatus as a diagnostic tool in Oriental medicine by providing standard temperature on specific acupoints. Methods: Subjects for the study was recruited through an advertisement in the school homepage(www.sangji.ac.kr) explaining the objectives and methods. 100 volunteers agreeing to terms were selected and measured the full body thermal image. Common acupoints used in the clinical surrounding were chosen and final 63 acupoints were selected for the measurement. Male/female and right/left readings were obtained for the analysis. Results: Following results were obtained from analyzing the body temperature of 50 male subjects and 50 female subjects 1. Subjects participating in the study ranged from 19 years of age to 44 years. Median male age at $26.86{\pm}6.02$ and female age at $22.88{\pm}2.74$, respectively. 2. For all acupoints, no significant differences were witnessed between the gender and right, left side of the body. 3. 10 acupoints from the facial region(18 bilateral), 8 acupoints from the chest/abdomen region(10 bilateral), 6 acupoints from the back region(11 bilateral), 17 acupoints from the upper extremity(34 bilateral), and 22 acupoints from the lower extremity(44 bilateral) were chosen. 4. In the facial region, BL2 showed the highest temperature and GV26 showed the lowest. 5. In the chest/abdomen region, CV22 showed the highest temperature and CV6 showed the lowest. 6. In the back region, GV14 showed the highest temperature and BL23 showed the lowest. 7. In the upper extremity region, jianqian(extra point) showed the highest temperature and baxie(extra point) showed the lowest. 8. In the lower extremity region, KI1 and bafeng(extra point) shoed the highest temperature and BL40 showed the lowest. Conclusions: Based on the standard body temperature measured on specific acupoints throughout the body, we hope these findings can trigger further studies on applications of infrared thermal imaging and clinical usage in the field of oriental medicine.