• 제목/요약/키워드: Temperature efficiency

검색결과 5,860건 처리시간 0.032초

An Experimental and Numerical Study on Thermal Performance of a Regenerator System with Ceramic Honeycomb

  • Ryou, Hong-Sun;Noh, Dong-Soon;Hong, Sung-Kook;Lee, Seong-Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • 제15권3호
    • /
    • pp.357-365
    • /
    • 2001
  • The aim of this paper is to perform the experiment and the numerical simulation for investigating the heat transfer in a regenerator system with ceramic honeycomb and to suggest a useful correlation for optimization of the regenerator system. For achieving this, the effects of some parameters were investigated, e. g., switching time, cell size and length of honeycomb on the mean temperature efficiency. The measured temperatures by R-type thermocouples were compared with the predictions by means of the commercial package, STAR-CD. A useful correlation for thermal efficiency was newly proposed as a function of the normalized switching time, defined in terms of switching time, cell size and length of honeycomb. The results showed that the thermal efficiency is above 90% and the normalized heat exchange rate is higher than 80% when the normalized switching time is less than 1000.

  • PDF

코어드 와이어 피딩에 의한 Cu 용탕에의 합금 첨가 시 효율 평가 (Evaluation on the Efficiency of Cored Wire Feeding in Addition of Alloying Elements into Cu Melt)

  • 강복현;김기영
    • 한국주조공학회지
    • /
    • 제33권6호
    • /
    • pp.248-253
    • /
    • 2013
  • To add alloying elements into a pure copper melt, the wire-feeding efficiency of cored (alloy containing) wire was evaluated using a commercial, computational fluid-dynamics program. The model design was based on an industrial-scale production line. The variables calculated included wire feed rate, melt temperature, wire diameter, melt flow rate and wire temperature. Efficiency was evaluated after a series of calculations based on the penetration depth of the alloy-wire into the molten copper bath. Of the five variables investigated, the wire feed rate and wire diameter were the most influential factors affecting the feeding efficiency of the cored-wire.

열역학 제2법칙에 의한 압축과정의 합리적 효율 (Rational Efficiency of Compression Processes by the Second Law of Thermodynamics)

  • 정평석
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1200-1210
    • /
    • 1990
  • 본 연구에서는 먼저, 단열 압축기 또는 단열압축 과정에 대한 기존의 효율들, 즉 등 엔트로피 효율과 폴리트로픽 효율 및 엑서지 효율에서의 출력에 해당하는 양의 의미를 검토하고, 이들을 엑서지 출력을 일반화 시킨 형태의 일종으로서 설명하며, 기 타의 가능한 효율을 정의하고, 나아가 같은 논리를 압축과정 중 외부와 열교환이 있는 비단열 압축과정에 대하여 확장 적용시켜 비단열 압축과정에서의 열역학 제2법칙적 출 력 및 효율들을 정의하고 그들의 특성을 살펴보려 한다.

원형휜-원형관 열교환기의 휜효율 이론에 관한 수치적 검증 (VERIFICATION OF FIN EFFICIENCY THEORY FOR THE CIRCULAR FINNED-TUBE HEAT EXCHANGER BY NUMERICAL EXPERIMENT)

  • 강희찬;임복빈;이종휘
    • 한국전산유체공학회지
    • /
    • 제14권4호
    • /
    • pp.7-12
    • /
    • 2009
  • The purpose of the present study is to investigate the convective heat transfer characteristics and the validity of fin efficiency of the circular finned-tube heat exchanger by using commercial CFD code. The heat transfer coefficient obtained by using the laminar model was 22% overestimated to the experimental data. The fin surface temperature compared with the experimental data measured by the liquid crystal method. The fin efficiency by the present numerical experiment, defined as normalized and averaged fin surface temperature, was greater than the theoretical fin efficiency and the difference is increased at high value of the factor $mr{\phi}$.

순산소 연소 기본 사이클의 작동조건 변화에 따른 성능해석 (Influence of Operating Conditions on the Performance of a Oxy-fuel Combustion Reference Cycle)

  • 박병철;손정락;김동섭;안국영;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2971-2976
    • /
    • 2008
  • Recently, there has been growing interest in the oxyfuel combustion cycle since it enables high-purity CO2 capture with high efficiency. However, the oxyfuel combustion cycle has some important issues regarding to its performance such as the requirement of water recirculation to decrease a turbine inlet temperature and proper combustion pressure to enhance cycle efficiency. The purpose of the present study is to analyze performance characteristics of the oxyfuel combustion cycle with different turbine inlet temperatures and combustion pressures. It is expected that the turbine inlet temperature improves cycle efficiency, on the other hand, the combustion pressure has specific value to display highest cycle efficiency.

  • PDF

에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구 (Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner)

  • 이홍원;문정호;배영돈;박종철
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.204-216
    • /
    • 1992
  • In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

  • PDF

Combustion Efficiency of Boron Carbide Fuel Solid Fuel Ramjet

  • Lee, Tae-Ho
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.722-725
    • /
    • 2004
  • An experimental investigation was conducted to investigate the effects of the equivalence ratio and air mass flux on the combustion efficiency in a solid fuel ramjet used fuel grains which were highly loaded with boron carbide. Combustion efficiency increased with increasing equivalence ratio (grain length), and decreasing air mass flux. Higher inlet air temperature produced higher combustion efficiencies, apparently the result of enhanced combustion of the larger boron particles those bum in a diffusion controlled regime. Short grains which considered primarily of the recirculation region produced larger particles and lower combustion efficiencies. The result of the normalized combustion efficiency increased with inlet air temperature, is coincident with the result of the Brayton cycle thermal and the total efficiency relating to the heat input.

  • PDF

반 실험적 방법을 통한 고체 램 제트 성능에 대한 흡입 공기 온도의 영향 (Inlet Air Temperature Effect on the Performance Efficiency of the Solid Fuel Ramjet through Semi-empirical Method)

  • 이태호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.29-33
    • /
    • 2005
  • 고체 램 제트 추진기관에서도 일반 로켓 추진기관에서와 같이 Isp 즉 추력을 증대 시키기 위하여 고체 입자들을 연료에 함유시킨다. 이러한 고체입자가 포함된 연료들은 매우 짧은 연소실 체류시간 때문에 연소 효율의 증대가 필수적이며 흡입공기 온도가 중요한 역할을 한다. 이 흡입공기 온도가 램 제트 성능에 미치는 영향을 조사하였다 성능조사는 실험적 방법에 한계가 있어 연소실험을 통한 연소효율을 이용하여 반-실험적으로 조사하였다. 연소실 흡입공기 온도에 영향을 미치는 인자는 자유 유동장 즉 대기 온도와 비행 마하 수이며 이들에 대한 효과를 조사하였다.

  • PDF

옥상녹화가 PV모듈 발전량에 미치는 영향 고찰 (A study on the effect that the green roof has on the performance of PV module)

  • 유동철;이응직
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.113-119
    • /
    • 2012
  • This study aims to examine the effect of the combined application of green roof and PV system on the PV efficiency by measuring the temperature and performance of PV module in order to reduce the temperature on the roof using roof planting system and determine the potential of efficient increase in solar-light power generation. In the experimental methodology, either monocrystalline or polycrystalline PV module was installed in green roof or non-green roof, and then the surface temperature of PV was measured by TR-71U thermometer and again the performance, module body temperature, and conversion efficiency were measured by MP-160, TC selector MI-540, and PV selector MI-520, respectively. As a result, the average body temperature of monocrystalline module was lower by $6.5^{\circ}C$ in green roof than in non-green roof; that of polycrystalline module was lower by $8.8^{\circ}C$ in green roof than in non-green roof. In the difference of generation, the electricity generation of monocrystalline module in green roof was 46.13W, but that of polycrystalline module was 68.82 W, which indicated that the latter produced 22.69W more than the former.

작동유체에 따른 유기랭킨사이클(ORC)의 열역학적 성능에 관한 연구 (Study of Working Fluids on Thermodynamic Performance of Organic Rankine Cycle (ORC))

  • 김경훈
    • 한국수소및신에너지학회논문집
    • /
    • 제22권2호
    • /
    • pp.223-231
    • /
    • 2011
  • The thermal efficiency of energy-to-power conversion becomes uneconomically low when the temperature of heat source drops below $370^{\circ}C$. ORC (Organic Rankine Cycle) has attracted much attention in last few years due to its potential in reducing consumption of fossil fuels and relaxing environmental problems, and its favorable characteristics to exploit low-temperature heat sources. In this work thermodynamic performance of ORC using nine working fluids is comparatively assessed. Special attention is paid to the effect of system parameters such as turbine inlet temperature and pressure on the characteristics of the system such as volumetric flow rate and quality at turbine exit, latent heat, net work as well as thermal efficiency. Results show that in selection of working fluid it is required to consider various criteria of performance characteristics as well as the thermal efficiency. Results also show that the system efficiencies become same irrespective of kind of working fluid when the temperature of heat source decreases to low range.