• Title/Summary/Keyword: Temperature distribution characteristic

Search Result 291, Processing Time 0.033 seconds

Modeling Dynamic Behavior and Injection Characteristic of a GDI Injector (GDI 인젝터의 동적 거동과 분사 특성에 대한 모델링)

  • Lee, Kye Eun;Kim, Na Young;Cho, Young Jun;Lee, Dong Ryul;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.22 no.4
    • /
    • pp.210-217
    • /
    • 2017
  • A gasoline direct injection engine has an intake air temperature can be lowered by the fuel vaporization in the combustion chamber increase the volume efficiency is high compression ratio. Therefore, study for injection rate and characteristics which influence mixture formation in combustion chamber is important. Movement of the injector needle has a direct effect on the injection of the fuel, such as formation of cavitation, the fuel injection rate, etc. Therefore, recent studies on the dynamic characteristics of the injector considering the movement of the needle have been reported, but it takes a lot of time and cost to experimentally confirm the movement of the needle inside the injector. In this study, AMESim, a commercial 1-D code, and Star-CCM+, a 3-D CFD code, were used to predict the dynamic performance of the injector with needle motion. In order to predict the movement of the needle under the high pressure, the result of the surface pressure distribution according to the movement of the needle was derived by using the morphing technique of flow analysis. In addition, we predicted the injection rate of the injector considering the movement of the needle in conjunction with the 1-D code. The injection rate of the injector was measured by the BOSCH's method and the results were similar to those of the simulation results. This method can predict the injection rate and injection characteristics and this result is expected to be used to predict the performance of gasoline direct injection engines with low cost and time in the future.

The Molecular Simulation Study for the Adsorption of $H_2S,\;NH_3$ and $CH_3SH$ on Graphite Carbon (Graphite Carbon에 $H_2S,\;NH_3$$CH_3SH$의 흡착에 대한 분자모사 연구)

  • 신창호;김종열;이영택;김정열;김승준
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.25 no.1
    • /
    • pp.59-69
    • /
    • 2003
  • The adsorption characteristics of H$_2$S, NH$_3$and $CH_3$SH on the graphite carbon have been investigated using Grand Canonical Monte Carlo(GCMC) method with universal force field (UFF) and dreiding force field. Most of the activated carbons used in vapor phase adsorption have the micropore of 6$\AA$ to 20$\AA$ and the specific surface area of ca. 1000 m$^2$/g, as the result of $N_2$ adsorption by BET method. For the more efficient comparison, the activated carbons have been manipulated with different pore sizes. The adsorption characteristics of H$_2$S, NH$_3$and $CH_3$SH have been considered at various temperatures and pressures. The adsorption amount using Dreiding force field is predicted to be lower than that using UFF. As the temperature is going to high, the adsorption amount of adsorbates is decreased due to their vaporization. Considering the pore size effect, the adsorption characteristic depends on the adsorbate size, polarity and interaction between adsorbates, etc. At all cases employed in this study, NH$_3$ is barely adsorbed and $CH_3$SH is preferentially adsorbed on the graphite carbon. Our theoretical result is qualitatively good agreement with the experimental observation. However, there are some quantitative discrepancies depending on the functional groups and pore size distribution on the real activated carbons used in experiment.

A Study on the Heat Transfer Phenomenon through the Glazing System (창호를 통한 열전달 현상에 관한 연구)

  • Kang, Eun-Yul;Oh, Myung-Won;Kim, Byung-Sean
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

Prediction of Ozone Concentration by Multiple Regression Analysis in Daegu area (다중회귀분석을 통한 대구지역 오존농도 예측)

  • 최성우;최상기;도상현
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.687-696
    • /
    • 2002
  • Air quality monitoring data and meteorology data which had collected from 1995. 1. to 1999. 2. in six areas of Daegu, Manchondong, Bokhyundong, Deamyungdong, Samdukdong, Leehyundong and Nowondong, were investigated to determine the distribution and characteristic of ozone. A equation of multiple regression was suggested after time series analysis of contribution factor and meteorology factor were investigated during the day which had high concentration of ozone. The results show the following; First, 63.6% of high ozone concentration days, more than 60 ppb of ozone concentration, were in May, June and September. The percentage of each area showed that; Manchondong 14.4%, Bokhyundong 15.4%, Deamyungdong 15.6%, Samdukdong 15.6%, Leehyundong 17.3% and Nowondong 21.6%. Second, correlation coefficients of ozone, $SO_2$, TSP, $NO_2$ and CO showed negative relationship; the results were respectively -0.229, -0.074, -0.387, -0.190(p<0.01), and humidity were -0.677. but temperature, amount of radiation and wind speed had positive relationship; the results were respectively 0.515, 0.509, 0.400(p<0.01). Third, $R^2$ of equation of multiple regression at each area showed that; Nowondong 45.4%, Lee hyundong 77.9%, Samdukdong 69.9%, Daemyungdong 78.8%, Manchondong 88.6%, Bokhyundong 77.6%. Including 1 hour prior ozone concentration, $R^2$ of each area was significantly increased; Nowondong 75.2%, Leehyundong 89.3%, Samdukdong 86.4%, Daemyungdong 88.6%, Manchondong 88.6%, Bokhyundong 88.0%. Using equation of multiple regression, There were some different $R^2$ between predicted value and observed value; Nowondong 48%, Leehyundong 77.5%, Samdukdong 58%, Daemyungdong 73.4%, Manchondong 77.7%, Bokhyundong 75.1%. $R^2$ of model including 1 hour prior ozone concentration was higher than equation of current day; Nowondong 82.5%, Leehyundong 88.3%, Samdukdong 80.7%, Daemyungdong 82.4%, Manchondong 87.6%, Bokhyundong 88.5%.

Optical Characteristic Analysis of Electrodeless Lamp due to the Density Difference of Mercury (수은의 밀도차에 의한 무전극 램프의 광특성 분석)

  • Lee, Kye-Seung;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.477-486
    • /
    • 2017
  • For the analysis of the optical characteristics of electrodeless lamps, all the lamp surface temperatures have been treated the same. However, the interpretation of optical properties in this way has not been sufficient in terms of accuracy. In this paper, to overcome this problem, we divided the inside of the bulb into two parts, hot spot and cold spot, and analyzed the density difference of mercury by different temperatures. Here, it is assumed that the distribution of temperature and density is linear. The effect of optical characteristics through redistribution of hot spot and cold spot density was analyzed. It was also confirmed that the ratio of the density of the redistributed discharge gas has a great influence on the saturation of the optical characteristics. Therefore, it is proved that the design method through the domestic setting is very useful in the actual design, and the method for shortening the time for stabilizing the optical characteristics is obtained.

Structural Improvement for Crack of Integrated Circuit in Single Board Computer by Structure Analysis (단일보드컴퓨터 구조해석을 통한 집적회로 균열현상의 구조적 개선)

  • Ryu, Jeong-min;Lee, Yong-jun;Sohn, Kwonil
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.460-465
    • /
    • 2019
  • In this study, we aim to derive a solution from the structural analysis for electrical failure of single board computers for computing navigation information. By analyzing the characteristic factor, we identify that crack occur on the central processing unit board due to a certain structural problem, and that the physical effect by the crack make communication function be impossible to perform, which it causes booting error. In order to find the location of excessive stress causing the crack, structural analysis for the single board computer is done. From the structural analysis, the areas where stress concentration occurs are identified, and improvement methods changing the structures are developed. As a result, we shows that stresses are reduced entirely on the stress distribution for the improved structure. In addition, heat analysis shows that changing the structure to reduce stresses is not affect to the heat radiation, and the thermal resistance of the actual equipment is verified by measuring the temperature of the heat sink applied with the improved structure.

Habitat Classification and Distribution Characteristic of Aquatic Insect Functional Feeding Groups in the Geum River, Korea (금강 수계 서식지 유형분류 및 수서곤충 섭식기능군 분포특성)

  • Park, Young-Jun;Kim, Ki-Dong;Cho, Young-Ho;Han, Yong-Gu;Kim, Yeong-Jin;Nam, Sang-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.5
    • /
    • pp.691-709
    • /
    • 2011
  • This study was performed to classify habitat types depending on environmental factors and to find out distribution characteristics of functional feeding groups of aquatic insects which were collected at that habitat types. Field survey was conducted twice in a year for every spring and fall from 2007 to 2008 for 38 sites in the Geum River. During the field survey 15 environmental factors were measured at each 38 sites and analyzed by similarity analysis method to classify habitat types. The result of similarity analysis showed that the 38 sites could be grouped into 7 classes like as C1 and C3 class belong to Head water(HD), C2 and C4 and C5 class belong to Middle stream(MS), C6 and C7 class belong to Large River(LR) based on euclidean distances 4. And also, we could extract the main environmental factors affecting the classification of habitat types such as Stream Width and Elevation of physical environmental factors, Water Temperature, Conductivity and DO of chemical environmental factors, percentages of Sand, Silt and Gravel of substrate factors. Total 142 species of aquatic insects in 46 families, 9 orders were collected during the field surveys and the occurrence number of species and individuals showed high correlation with the Velocity factor and the percentage of Sand factor of each habitat types. In addition, correlation analysis between functional feeding groups and environmental factors represented that (1) Filtering-collectors(FC) affected by Velocity, Stream Width and Silt, (2) Gathering-collector(GC) affected by Velocity, (3) Predator(P) affected by Elevation, Velocity, Boulder, Conductivity and Sand, (4) Plant-piecer(PP) affected by Water Width and Silt, (5) Scraper(SC) affected by Elevation and Conductivity, (6) Shredder(SH) affected by Elevation, Boulder, DO, pH, Conductivity and Water Temperature respectively. As a result of this study, Elevation, Stream Width, Velocity, Conductivity, Water Temperature and percentage of Sand factors which were deduced by stepwise multiple regression analysis had correlations($r{\geqq}0.600$, p<0.01) with biota community inhabitation. Therefore these six environmental factors were regarded as major environmental factors that might affect highly the distribution of functional feeding groups in stream ecosystem of the Geum River.

Spatial and Temporal Variability of Residual Current and Salinity according to Freshwater Discharge in Yeoungsan River Estuary (방류 유무에 따른 영산강 하구역의 시공간적 잔차류 및 염분 변화)

  • Kim, Jong-Wook;Yoon, Byung Il;Song, Jin Il;Lim, Chae Wook;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.103-111
    • /
    • 2013
  • In this study, field measurements were conducted in the section about 7 km from sea dike to westward. The observations of along channel current were carried out, and water temperature and salinity were measured simultaneously at 10 stations during one tidal cycle, and sampling interval is 1 hour. The maximum ebb current is about 1.5 m/s at the surface layer but flood current is 0.4 m/s at the bottom layer during discharge period. Residual current during river discharge shows two layer structures which is typical characteristic of the estuary system. On the other hand, residual current during a period with no discharge has shown multi-layer structure different from general estuarine systems. The distribution of high salinity can be seen at the bottom layer as the effect of discharge does not reach down to the bottom layer during discharge. As a result, freshwater is not effected at the bottom layer during observation, and mixing of surface layer to bottom layer is reduced by stratification.

Phytohydrography and the Vertical Pattern of Nitracline in the Southern Waters of the Korean East Sea in Early Spring (춘계 한국 동해 남부해역에서의 식물 수문학적 수역과 질산염약층의 수직양상)

  • Shim, Jae Hyung;Yang, Sung Ryull;Lee, Won Ho
    • 한국해양학회지
    • /
    • v.24 no.1
    • /
    • pp.15-28
    • /
    • 1989
  • A study on quantitative phytoplankton samples, hydrographic conditions (temperature, salinity, dissolved oxygen), and nutrients has been performed in the southern waters of the Korean East Sea in early spring. Phytoplankton community showed close correlation with hydrographic conditions. This study area could be divided into three phytohydrographic regions; 1) East Korean Warm Water Region (a branch of Tsushima Current), 2) North Korean Cold Water Region, and 3) offshore water region not affected by other two water regions. Vertical distribution of phytoplankton is dependent upon stability of water column and nutrient concentration. Nutrient concentration shows characteristic distribution according to water masses. N/P ratio of ca. 3 in surface layer indicates that nitrogen is the major limiting nutrient in this area. N/P removal ratio was 12.54 ($r^2$ = 0.96), consistent with the Redified ratio. Primary nitrite maxima at the nitracline depths are thought to be formed by phytoplankton exudation. Secondary nitrite maximum was observed in coastal area with dissolved oxygen content of >5.2 ml/l much higher than <0.25 ml/l in other areas. The mechanism of secondary maximum is different from that of other regions, and whether it may be due to in situ degradation of organic matter by bacterial activity is still open to discuss.

  • PDF

The Acclerated Life Test of Hard Disk In The Environment of PACS (PACS 환경에서 하드디스크의 가속 수명시험)

  • Cho, Euy-Hyun;Park, Jeong-Kyu;Chae, Jong-Gyu
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.63-70
    • /
    • 2015
  • In this paper, we estimate the life cycle from acceleration life test about the hard disk of disk array of image storage of PACS. Webuil distribution was selected by the Anderson-Darling goodness-of-fit test with data of down time at $50^{\circ}C$ and $60^{\circ}C$. The equality test of shape parameter and scale parameter was conducted, so that the probability distribution estimated from data of down time at $50^{\circ}C$ and $60^{\circ}C$ was not statistically significant. The shape parameter was 1.0409, The characteristic life was 24603.5 hours at normal user condition($30^{\circ}C$) by the analysis of weibull-arrhenius modeling which included the acceleration factor of temperature, and The activation energy was 0.5011 eV through arrhenius modeling. The failure analysis of the failure samples of acceleration test and the samples of market return was conducted, so that the share percentage of failure mode was detail difference but the rank of share percentage was almost same. This study suggest the test procedure of acceleration test of hard disk drive in PACS using environment, and help the life estimation at manufacture and use.