• Title/Summary/Keyword: Temperature calculation

Search Result 1,455, Processing Time 0.024 seconds

Properties of a HTS magnet consisting of pancake windings by using the E-J method

  • Kim, Young-Min;Kang, Myung-Hun;Paik, Kyoung-Ho;Cha, Guee-Soo;Jeon, Chang-Wan
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.4
    • /
    • pp.26-29
    • /
    • 2011
  • In a High temperature superconducting (HTS) tape with high aspect ratio, the magnetic field applied to the HTS tape can be different considerably within the HTS tape. The current distribution in the HTS tape is generally non-uniform because the current distribution is strongly dependent on the applied magnetic field. Non-uniform current distribution in a HTS tape has not been properly considered when the critical current has been estimated. This paper shows the calculation of critical current of a HTS magnet consisting of pancake windings. Non-uniform distribution of current in the HTS tape is considered during the calculation of the critical current. Results of calculation show the current concentrated in the middle part of the HTS tape which is used for one pancake winding.

The Calculation Method of Coal Pyrolysis Products Depending on the Coal Rank (탄종별 열분해 생성물의 조성 계산방법)

  • Pak, Ho-Young;Seo, Sang-Il
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.5
    • /
    • pp.442-451
    • /
    • 2010
  • This paper describes the calculation method to obtain the product composition of coal pyrolysis at high pressure and high temperature. The products of coal pyrolysis should be determined for the coal gasifier simulation, and this is the first step of the coal gasifier simulation. The pyrolysis product distribution greatly affects the coal gasifier efficiency such as carbon conversion, cold gas efficiency and the syngas composition at the outlet of the gasifier. The present calculation method is based on the coal ultimate/proximate analysis and several correlations among gasifier pressure, coal properties and pyrolysis products. The calculated products for 5 coals have been compared with those from the commercial pyrolysis model.

A Study of Mg Capping Inside p-tert-butylcalix[4]arene Adsorbed on a Ge(100) Surface

  • Shin, Minjeong;Lee, Myungjin;Lee, Hangil
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.135-135
    • /
    • 2013
  • The electronic and adsorption structures of Mg and p-tert-butylcalix[4]arene (p-TBCA) adsorbed onto a Ge(100) surface under a variety of sample conditions were characterized using high-resolution photoemission spectroscopy (HRPES) and their corresponding DFT calculation results. Interestingly, after 0.10 ML p-TBCA molecules had been adsorbed onto a Ge(100) surface, subsequent adsorption of a small amount of metallic Mg (~0.10 ML) resulted in the formation of a capped structure inside the pre-adsorbed p-TBCA molecules. The adsorption structures resulting from further deposition of Mg (~0.50 ML) onto the Ge(100) surface were monitored based on the surface charge state and Mg 2s core level spectrum. Work function measurements clearly indicated the electronic structures of the Mg and p-TBCA adsorbed onto the Ge(100) surface. Moreover, we confirmed that three different adsorption structures are experimentally favorable at room temperature through DFT calculation results.

  • PDF

A Study of Temperature Changes in the Dental Tissues Irradiated by $10.6{\mu}m$ Laser Beam ($CO_2$ 레이저 광의 조사조건에 따른 치아의 치수강내 온도상승에 관한 연구)

  • Ko, D. S.;Bak, Y. H.;Shin, S. H.;Eom, H. S.;Kim, U.;Lee, C. Y.
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.210-216
    • /
    • 1990
  • This study was performed to obtain fundamental data on temperature increases in the dental tissues irradiated by IO.opm laser radiation. For this purpose a experimental facility was established. which was composed of a CO2 laser. a shutter unit and a temperature sensing device. The temperature changes in the pulp chamber of extracted molars. during and after the laser irradiation. were measured as function of laser power. the time of irradration and the thickness of the sample. An empirical formula for the maximum temperature increases, $\DeltaT_m$ was derived from the measured data as follows; $\DeltaT_m=\alphaP\Delta\tauexp(-\betad)$$ where P. $\Delta\tau$ and d are the laser power(W). irradiation time{sec) and the thickness(mm) between pulp chamber and occlusal surface. respectively. Also a theoretical calculation model based on simplified assumptions were established and the results from the calculation were compared with the measured temperature data. A fairly good agreement was obtained.obtained.

  • PDF

The Effect of Flow Rate into Room by Natural Convection in Air Conditioner Duct (공조기 덕트 내의 자연대류가 실내 유입유량에 미치는 영향)

  • 공태우;정한식;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.160-166
    • /
    • 2001
  • A numerical analysis has been performed for natural convection in an air conditioner duct system. The governing equations were solved a finite volume method using a SIMPLE algorithm. In the calculation mode of duct, the room temperature was preserved at $25.0^{\circ}C$ and duct wall temperature had a temperature of 15, 20.0, 22.5, 23.75, 26.25, 27.5 30 and $35^{\circ}C$. The results of velocity vectors and contours have been represented for various parameters. Based on the numerical data, the relationships between temperature difference and flow rate into room was represented. In the case of $T_\gamma>T_\omega$, the equation for temperature difference and flow rate was $Q=0.0285\triangleT^0.4005$, and in the case of $T_\gamma>T_\omega$, the equation was $Q=0.0099\triangleT^0.4752$. The duct system has an important relation to room temperature and duct wall temperature.

  • PDF

Analysis and Measurement of Rough Surface Temperature Rise in Lubricated Condition (거친 표면의 마찰온도 해석 및 온도측정 실험에 관한 연구)

  • Lee, Sang-Don;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.23 no.2
    • /
    • pp.56-60
    • /
    • 2007
  • The main object of this study is to compare the results that have been concluded by the experiment and to estimate the temperature rise that can cause the contacting surface to be damaged. The former studies are based on the Blok and Jaeger formula. By these formulas we assume that two of the contacted objects are a kind of semi-infinite solid and with this assumption we can make a temperature analysis. But this method doesn't consider lubrication conditions and the calculation time requires a lot of time in that we have to face many difficulties in measuring the actual temperature rise. In this study we combines the semi-infinite solid method and the finite volume method to analyze the temperature of the contacting surface. And we measure temperature rise of the contact surface by dynamic thermocouple.

A Study on the Power Loss Simulation of IGBT for HVDC Power Conversion System

  • Cho, Su Eog
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_1
    • /
    • pp.411-419
    • /
    • 2021
  • In this study, IGBT_Total_Loss and DIODE_Total_Loss were used to analyze the slope of the junction temperature for each section for temperature and duty variables in order to simply calculate the junction temperature of the power semiconductor (IGBT). As a result of the calculation, IGBT_Max_Junction_Temp and DIODE_Max_Junction_Temp form a proportional relationship with temperature for each duty. This simulation data shows that the power loss of a power semiconductor is calculated in a complex manner according to the current dependence index, voltage dependence index, and temperature coefficient. By applying the slope for each condition and section, the junction temperature of the power semiconductor can be calculated simply.

Study of Pd substitution in orthorhombic-NiSi/Si (010) structure: First principles calculation (Orthorhombic-NiSi/Si (010) 구조의 Pd 치환 연구: 제 1 원리 계산)

  • Kim, Dae-Hee;Kim, Dae-Hyun;Seo, Hwa-Il;Kim, Yeong-Cheol
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.4
    • /
    • pp.41-44
    • /
    • 2008
  • NiSi is less stable than the previously-used $CoSi_2$ at high temperature. Some noble metals, such as Pd and Pt, have been added to NiSi to improve its thermal stability. We employed a first principles calculation to understand the Pd segregation at the interface. An orthorhombic structure of NiSi was used to construct an orthorhombic-NiSi/Si (010). Lattice parameters along a- and c-axes in orthorhombic-NiSi were matched with those of Si for epitaxy contact. The optimized $1\times4\times1$ orthorhombic-NiSi (010) and $1\times2\times1$ Si (010) superstructures were put together to construct the orthorhombic-NiSi/Si (010), and the superstructure was relieved in calculation to minimize its total free energy. The optimized interface thickness of the superstructure was $1.59\AA$. Pd atom was substituted in Ni and Si sites located near interface. Both Ni and Si sites located at the interface were favorable for Pd substitution.

  • PDF

Verification Experiment and Calculation of Cooling Load for a Test Space (시험공간에 대한 냉방부하 실증실험 및 계산)

  • 유호선;현석균;김용식;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.641-651
    • /
    • 2003
  • In order to assess the reliability of a building energy simulation program (TRNSYS) from the standpoint of user, a set of verification experiment and calculation of cooling load for a test space is carried out. This work is a complement of the previous study that dealt with heating load for the same space. The test space is kept airtight to eliminate the source of uncertainties in modeling. A window-mounted, on/off controlled air-conditioner is used for cooling, whose performance has been established a priori. The calculation encompasses two models for evaluating cooling load in TRNSYS: energy rate control and temperature level control. Comparison of the total cooling loads obtained from different sets of experimental data enables to validate the measurements. The experimental result shows that the latent load is fairly large even in the absence of apparent air change in the space, which needs to be clarified. Each of hourly and daily accumulated sensible loads is compared between the experiment and two calculation models. Despite an inconsistency associated with solar irradiation, both of the models agree favorably with the experiment within a tolerance, illustrating their capability of properly predicting space thermal loads.

Study on the Temperature Drift Adaptive Compensation Algorithm of a Magneto-Electric Encoder Based on a Simple Neuron

  • Wang, Lei;Hao, Shuang-Hui;Song, Bao-Yu;Hao, Ming-Hui
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1254-1262
    • /
    • 2014
  • Magneto-electric encoders have been widely used in industry and military applications because of their good shock resistance, small volume, and convenient data processing. However, the characteristics of a magneto-electric encoder's signal generator and hall sensor changes minimally with temperature variation. These changes cause an angle drift. The main purpose of this study is to construct the compensation system of a neural network and constantly update weight coefficients of temperature correction by finite iteration calculation so that the angle value modified can approach the angle value at the target temperature. This approach is used in adaptive correction of the angle value.