• Title/Summary/Keyword: Temperature Variation Rate

Search Result 994, Processing Time 0.032 seconds

A study on the characteristics of environmental factors of granite dome models with different envelope structures in winter (외피 유형별 석재 모형돔의 동절기 환경 특성에 관한 연구)

  • 공성훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.642-646
    • /
    • 1999
  • Factors governing the rate of heat exchange comprise the air temperature, the speed of air movement, relative humidity, and relation indoors. Recently, there are many researches on the transient analysis of indoor environmental factors such as the dry bulb temperature, relative humidity and air velocity in miniature models. The purpose of this study is to measure the environmental factors and to analyze and evaluate the characteristics of indoor environment with the different envelope structures using a granite dome model. According to the variation of humidity, the state of interior relative humidity for clay model has an equal tendency, although a little range of variation is shown in comparison to the cement model.

  • PDF

Performance Analysis of a 5 RT Air-Cooled $NH_3-H_2O$ Absorption Chiller with the Variations of Heat Input and Ambient Temperature (5 RT 공랭형 $NH_3-H_2O$ 흡수식 냉동기의 발생기 입력 열량과 외기온도 변화에 따른 성능분석)

  • 윤희정;김성수;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.438-443
    • /
    • 2004
  • The objective of this paper is to study the effects of the input gas flow rate and the ambient temperature variation on the absorption cycle performance. An air-cooled NH$_3$-$H_2O$ absorption chiller is tested in the present study. The nominal cooling capacity of the single effect maching is 17.6 ㎾ (5.0 USRT). The cooling capacity, coefficient of performance, burner efficiency, and each state point are measured with the variations of the heat input and the ambient temperature. It is found that the COP and cooling capacity increase with increasing the generator exit temperature up to a certain temperature and then decrease. It is also found that the COP and the cooling capacity decrease with increasing the ambient temperature. The maximum COP of 0.51 is obtained from the present experiment.

Prediction of Oil Lifetime due to Overheating of Oil and Bearing Housing in a Pump (펌프 베어링하우징에서 베어링과 오일의 과열 및 오일수명 예측)

  • 한상규;강병하;이봉주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.408-413
    • /
    • 2004
  • An experimental study has been carried out to investigate overheating of oil and bearing housing during pump operation. This problem is of particular interest in the pre diction of lifetime and failure of pump. Transient variation of oil temperature as well as bearing housing temperature is measured to study the effect of oil viscosity, oil amount, and discharge flow rate of pump. It is found that optimal oil quantity as well as proper viscosity of oil is required to keep the safe temperature level of oil and bearing housing in a pump. The oil temperature at steady state is almost not affected by discharge flow rate in the range of discharge flow rates considered in the present study.

Mechanical Properties of Aluminium Alloy with Cellular Structure. (미세기공 알루미늄 소재의 기계적 성질)

  • 윤성원;이승후;강충길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.695-698
    • /
    • 2002
  • Induction heating process is one of the most efficient heating process in terms of temperature control accuracy and heating time saving. In the past study, fabrication process of cellular 6061 alloys by powder metallurgical route and induction heating process was studied. To supplement the framing conditions that studied in past study, effect of induction heating capacity and holding time at foaming temperature were investigated. Under the achieved framing conditions, teamed 6061 alloys were fabricated for variation of foaming temperature, and porosities(%)-foaming temperature curves were obtained by try-error experimental method. Uniaxial compression tests were performed to investigate the relationship between porosities(%) and stress-strain curves of framed 6061 alloy. Also, energy absorption capacity and efficiency were calculated from stress-strain curves to investigated. Moreover, dependence of plateau stress on strain rate was investigated in case of cellular 6061 alloy with low porosities(%)

  • PDF

Characteristics of Dynamic Strain Aging(DSA) in SA106Gr.C Piping Steel

  • Kim, Jin-Weon;Kim, In-Sup
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.771-776
    • /
    • 1995
  • Tensile and J-R tests were carried out to estimate the effects of dynamic strain aging(DSA) on SA106Gr.C piping steel. Tensile tests were performed under temperature range RT to $400^{\circ}C$ md strain rates from $1.39{\times}10^{-4}\;to\;6.95{\times}10^{-2}/s$. Fracture toughness was tested in the temperature range RT to $350^{\circ}C$ and load-line displacement rates 0.4 and 4mm/min. The effects of DSA on the tensile properties were clearly observed for phenomena such serrated flow, variation of ultimate and yield stress, and negative stram rate sensitivity. However, the magnitude of serration and strength increase by DSA was relatively small. this may be due to high ratio of Mn to C. In addition, crack initiation resistance, Ji and crack growth resistance, dJ/da were reduced in the range of $200-300^{\circ}C$, where DSA appeared as serrated flow and UTS hardening. The temperature corresponding to minimum fracture resistance was shifted to higher temperature with increasing loading rate.

  • PDF

Thermal Design Analysis of an Absorption Heat Transformer for using Waste Hot Water (폐온수 이용 제 2 종 흡수식 열펌프의 열역학적 설계해석)

  • Kang, Byung-Ha;Kim, Young-In;Lee, Chun-Sik
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.4
    • /
    • pp.285-292
    • /
    • 1985
  • A computer program for thermal design analysis has been developed to predict the performance of an absorption heat transformer. The effects of temperature boost, cooling water temperature and effectiveness of components on the performance were investigated. Not only the detailed thermodynamic states such as temperatures, concentration of the solution, and mass flow rate at each point of the process but also the heat transfer rate in each component could be easily determined with given input parameters. The system's coefficient of performance (COP) was seen to increase with increased effectiveness of components, decreased temperature boost of hot water, and decreased cooling water temperature. Even though the COP increases with increased effectiveness of the components, the variation in the COP is not substantial above certain values of the effectiveness. A reference design point can be selected on this basis.

  • PDF

Characteristics of $\beta$-glucosidase Immobilized on the Diazotized Chitin in Bioreactors (Diazotized Chitin에 고정된 $\beta$-glucosidase의 생물 반응기에서의 동특성)

  • 김종덕;이경희송승구
    • KSBB Journal
    • /
    • v.6 no.2
    • /
    • pp.147-156
    • /
    • 1991
  • Diazotized chitin (CHITN) was synthesized reacting with NaN3 and HCl to alkaline hydrolyzed chitin for the support of immobilized enzyme. Immobilized $\beta$-glucosidase on diazotized chitin(CHITN-Gase) was produced reacting with glutaraldehyds as bifunctional reagent. CHITN-Gase activities were determined reacting with p-nitrophenol-$\beta$-D-glucopyranoside in plug flow reactor as a reference. Optimum temperature, optimum pH, reaction constant and deactivation rate were determined with variation of flow rate and H/D. The particle size of immobilized enzyme in the best was, 35 mesh (CHITN35-Gase). The optimum conditions of immobilized enzyme were $70^{\circ}C$ in temperature and 5.0 in pH. Diameter and flow rate of plug flow reactor in the best was 8.5mm in diameter and 0.8ml/min in flow rate. Reaction constant was mainly influenced by electrostatic force. The best glucose hydrolizing activities of CHITN3 5-Gase was 3.34$\times$10-5 M/1. while that of native-$\beta$-glucosidase was 2.44$\times$10-5 M/1.

  • PDF

A Numerical Study on the Growth and Composition of InGaAs, InGaP and InGaAsP Films Grown by MOCVD (MOCVD에 의한 InGaAs, InGaP 및 InGaAsP필름의 성장 및 조성변화에 대한 수치해석 연구)

  • Im, Ik-Tae;Kim, Dong-Suk;Kim, Woo-Seung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.1 s.10
    • /
    • pp.43-48
    • /
    • 2005
  • Metaloganic chemical vapor deposition, also known as metalorganic vapor phase epitaxy has become one of the main techniques for growing thin, high purity films for compound semiconductors such as GaAs, InP, and InGaAsP. In this study, the distribution of growth rate and composition of InGaAsP, InGaP, and InGaAs films are studied using computational method. The influences of process parameters such as pressure, temperature and precursors' partial pressure on the growth rate and composition distributions are analyzed. The film growth rate is increased in the upstream part according to the increase of temperature but not in the downstream part. The Ga composition in InGaAsP film shows an asymptotic behavior for temperature variation but As composition varies significantly within the temperature range considered in the present study. The overall film growth rates of InGaP, InGaAs and InGaAsP are decreased with increasing the Ga/In ratios of the source gases. Pressure variation does not seem to be a significant parameter to the film growth. Film growth characteristics of tertiary films such as InGaP and InGaAs show similar trends to the quaternary film, InGaAsP.

  • PDF

Varietal Variation of Alkali Digestion Value and Its Relationship with Gelatinization Temperature and Water Absorption Rate of Milled Rice Grain (쌀 알칼리붕괴반응의 품종간 변이와 호화온도 및 수분흡수율과의 관계)

  • Kwang-Ho Kim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.1
    • /
    • pp.28-36
    • /
    • 1992
  • Fifty rice varieties were tested for alkali digestibility of milled rice grain at four different KOH levels, and twenty-four varieties selected were tested again for alkali digestibility at different degrading times and KOH levels. Gelatinization rate at several heating times and heating temperatures, and water absorption rate at 21$^{\circ}C$ and 77$^{\circ}C$ water temperatures were observed using rice samples of twenty-four varieties to clarify the relationship between alkali digestibility response, gelatinization rate and water absorption rate. Varietal difference of ADV in Japonica and Tongil tye rices was biggest at KOH 1.2%, but it was better to test at KOH 1.2% and 1.4% levels to know the exact alkali digestibility response of rice varieties. Rice varieties tested could be classified into three groups, low, intermediate and high, based on their alkali digestibility response at four KOH levels, and most of Korean cultivated rice varieties were belonged to intermediate or high ADV group. Varietal variation was also found in alkali degrading response at different soaking times in alkali solution. Low ADV varietal group showed higher gelatinization temperature and needed longer heating time for complete gelatinization compared with intermediate or high ADV group. Same trends was found between intermediate and high ADV groups, but varietal variation in the same ADV group was also found in gelatinization temperature and heating time needed for complete gelatinization of rice grain. Water absorption rate of low ADV group was lower than intermediate or high ADV group both at 21$^{\circ}C$ and 77$^{\circ}C$ water temperatures, and intermediate ADV group showed lower absorption rate than high ADV group only in initial water absorption stage at 21$^{\circ}C$.

  • PDF

A Study on Annealing Cycle Control Temperature of Hi - CON/2 BAF and HNx BAF (Hi-CON/H2 BAF와 HNx BAF의 소둔사이클 제어온도에 관한 연구)

  • 김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.114-122
    • /
    • 1994
  • A cold temperature control system for the BAF(batch annealing furnace) has been established in order to reduce energy consumption to imrpove productivity and stabilize the properties of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, changing annealing cycle time according to BAF temperature with time during heating and actual temperature measurements cold spot during soaking. The results of the temperature variation effect on the batch annealing are as follows. 1) Cooling rate is increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component. Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas and annealing cycle time is reduce to 2.7 times. 2) With enlarging the difference between furnace temperature and soaking temperature at the HNx BAF, heating time becomes short, but cooling time is indifferent. 3) If temperature difference of 300.deg. C in the temperature change of cold spot according to the annealing cycle control temperature, Hi-CON/H2BAF is interchanging at each other at 26hours, but HNxBAF at 50 hours. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1219 mm width coil must be 2.5 hours longer then that of 914mm width coil for the same coil weight at Hi-CON/H2BAF. But, it is necessary to make 2 hours longer at HNxBAF.

  • PDF