• Title/Summary/Keyword: Temperature Trend

Search Result 1,284, Processing Time 0.025 seconds

Comparison of temperature Derived from the Microwave Sounding Unit and Radiosonde Observation Data in Korea (한반도 지역의 마이크로파 위성자료와 고층관측자료의 비교)

  • 김소현;황병준;안명환;정효상;김금란
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.1
    • /
    • pp.47-54
    • /
    • 2000
  • We compared the satellite observed temperature with the radiosonde observed temperature in the Korean Peninsula. The radiosonde observed data were obtained from four upper air observation stations in the Korean Peninsula from 1981 to 1998, and were compared with the satellite observed data of the channel-2 and channel-4 of microwave sounding unit(MSU) on board NOAA series of polar-orbiting satellites. The radiosonde data were reconstructed from radiosonde T$_b$ using MSU weighting function. The monthly climatology shows radiosonde T$_{b2}$ is higher than MSU T$_{b2}$ in summer. The correlation between MSU T$_{b2}$ and radiosonde T$_{b2}$ is 0.72-0.76 and 0.73-0.81 between MSU T$_{b4}$ and radiosonde T$_{b4}$. The T$_{b2}$ show a positive trend and the T$_{b4}$ has a negative trend during the 18 years.

Verification of Freezing Index and Frost Penetration Depth with Temperature Data of Korea LTPP (국내 LTPP 온도 자료를 이용한 동결지수와 동결깊이 검증 연구)

  • Kim, Boo-Il;Jeon, Sung-Il;Lee, Moon-Sup;Lim, Kwang-Su
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.143-152
    • /
    • 2009
  • The purpose of this study is to evaluate the freezing index and frost penetration depth. The freezing index and frost penetration depth were analyzed using air temperature and temperature profile of pavement system in Korea LTPP-SPS(Long Term Pavement Performance-Specific Pavement Study) site. The predicted frost penetration depth were then compared with the measured one from the LTPP sites. And the trend of annual freezing index was analyzed using the temperature data of meteorological stations located in the vicinity of Korea LTPP-SPS site. The result showed that the freezing index was rapidly decreased since 1987, and it was known that the use of freezing index determined from the past 30 years temperature data could cause the over estimates in the pavement thickness design. The temperature profile measured at 3 sections of LTPP-SPS sites showed that the temperature of subbase layer was above $0^{\circ}C$, even though anti-frost layers were found in these sections. Comparing the measured and calculated frost depth, the frost depth calculated from the subgrade frost penetration permissible method showed a similar trend with the measured frost depth.

  • PDF

Climatic Characteristics of August and Summer of 2007 and Long Term Trend of August and Summer Climate (한반도의 2007년 8월과 2007년 여름의 기후특성 및 8월과 여름의 장기 기후변화)

  • Shin, Im Chul;Kim, Tae Ryong;Lee, Eun-Jung;Kim, Eun-Hee;Kim, Eun Suk;Park, Yeon Ok;Bae, Sun-Hee;Yi, Hi-Il
    • Atmosphere
    • /
    • v.17 no.4
    • /
    • pp.471-481
    • /
    • 2007
  • Temperature and precipitation, particularly August and summer, in the Korean peninsular are analyzed. The analyzed period is 1973-2007 for the Korean peninsular (that is, 60 meteorological station average). In addition, 100 year record (1908-2007) of temperature and precipitation in Seoul are also analyzed. Results indicate that the temperatures (mean, maximun, and minimum) of August and summer of 2007, both in Korean peninsular and Seoul, are higher than normal. The increasing rate of minimum temperature for the August and summer during the period from 1973 to 2007 shows greater than the mean and maximum temperature both in Korean peninsular and Seoul due to the global warming and urbanization. Number of tropical night days, defined by the days with above $25^{\circ}C$ in minimum temperature, shows increasing trend both in August and summer from 1973 to 2007 due to the combination effect of the global warming and urbanization. The amount of precipitation, both in August and summer, for Korean peninsular and Seoul shows increasing trend from 1973 to 2007, and 1908 to 2007, respectively. Amount of precipitation and rainy days, both August and summer, during 2000s show greater than those of the 1970s both in Korean peninsular and Seoul. Extreme rainy days (greater than 120mm/day, greater than 80mm/day, greater than 30mm in any 1-hour period and greater than 10mm in any 10-minute period) show increasing trend from 1973 to 2007 for both in August and in summer.

Temperature Control of an Oil Cooler System For Machine Tools Using a Fuzzy- Logic-Based Algorithm

  • Kim, Sun-Chul;Hong, Dae-Sun;Lee, Choon-Man;Kim, Gyu-Tak
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1006-1011
    • /
    • 2004
  • Recently, technical trend in machine tools is focused on enhancing of speed, accuracy and reliability. Such high speed usually results in thermal displacement and structural deformation. To minimize such thermal effect, most precision machine tools adopt high precision cooling system. This study proposes a temperature control for an oil cooler system using PI control with fuzzy logic. In a cooler system, the refrigerant flow rate is controlled by rotational speed of the compressor, where the outlet oil temperature is selected as the control variable. The fuzzy control rules iteratively correct PID parameters to minimize the error, difference between the outlet temperature and the reference one. Here, the ambient temperature is used as the reference one. To show the effectiveness of the proposed method, a series of experiments are conducted for an oil cooler system of machine tools, and the results are compared with the ones of a conventional PID control. The experimental results show that the proposed method has advantages of smaller overshoot and smaller steady state error.

  • PDF

Effect of Heat Treatment on the Mechanical Properties of Carbon Fiber (탄소섬유의 기계적 특성에 대한 열처리의 영향)

  • Kim, Bu-An;Moon, Chang-Kwon;Choi, Young-Min
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.13-19
    • /
    • 2017
  • The effect of heat treatment temperature (HTT) on the mechanical properties of polyacrylonitrile (PAN)-based carbon fiber had been investigated. The heat treatment on the carbon fiber was conducted under high vacuum atmosphere of $10^{-6}mmHg$, and the range of temperature of $1,000^{\circ}C$ to $2,000^{\circ}C$. As a results, The tensile strength of carbon fiber and carbon fiber composites showed increasing tendency with the rise of heat treatment temperature. And, the shape parameter of Weibull distribution for the strength of carbon single fiber showed an increasing trend until $1,800^{\circ}C$. But the shape parameter of Weibull distribution for the strength of carbon fiber composites showed no clear tendency with the rise of heat treatment temperature. The cause of reinforcement effect of the carbon fiber by the heat treatment was regarded as the carbonization of carbon single fiber.

A numerical study on the transient operation of high temperature heat pipe with a switching heat source (열원이 바뀌는 고온용 히트파이프의 천이 과정 동작에 관한 수치적 연구)

  • Park, Jong-Heung;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.68-78
    • /
    • 1997
  • A numerical study on the transient vapor flow and heat transfer is performed to investigate the ideal switching operation of heat source in a high temperature heat pipe. The cylindrical 2-dimensional compressible laminar vapor flow is assumed for the vapor space and the conjugate heat transfer for the heat pipe wall, wick and vapor space is calculated. The different boundary conditions such as constant heat flux, convective or radiative boundary at the outer wall are used respectively to compare the influence of boundary conditions on the transient operation. The transient temperature profile and the internal flow of the entire pipe for the switching operation are described as a result. The results show that the transient time is not significantly affected by the boundary conditions at the outer wall in present study. During the transition, two independent flows are observed temporarily on the right side and left side of the heat pipe. It is also found that the trend of temperature variation in the vapor region is different from the variation in the wick and wall region.

The Characteristics of Pulverized Coal Combustion in the Two Stage Cyclone Combustor

  • Joo, Nahm-Roh;Kim, Ho-Young;Chung, Jin-Taek;Park, Sang-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1112-1120
    • /
    • 2002
  • Numerical investigations on air staging and fuel staging were carried out with a newly designed coaxial cyclone combustor, which uses the method of two stage coal combustion composed of pre-combustor and main combustor. The pre-combustor with a high air/fuel ratio is designed to supply gas at high temperature to the main combustor. To avoid local high temperature region in this process, secondary air is injected in the downstream. Together with the burned gas supplied from the pre-combustor and the preheated air directly injected into main combustor, coals supplied through the main burner react rapidly at a low air/fuel ratio. Strong swirling motion of cyclone combustor keeps the wall temperature high, which makes slagging combustion possible. Alaska, US coal is used for calculations. Predictions were made for various coal flow rates in the main combustor for fuel staging and for the various flow rate of secondary air in the pre-combustor for air staging. In-scattering angles are also chosen as a variable to increase residence times of coal particles. Temperature fields and particle trajectories for various conditions are described. Predicted temperature variations at the wall of the combustor are compared with corresponding experimental data and show a similar trend. The in-scattering angle of 20° is recommended to increase the combustion efficiency in the main chamber.

Effect of Quenching and Tempering Temperatures on Mechanical Properties of A487 Cast with Different C Contents (C 함량이 다른 A487 주강품의 열처리 조건에 따른 기계적 및 부식 특성)

  • Jung, Woo-Jin;Jeong, Dae-Ho;Lee, Young-Cheol;Lee, Jae-Hyun;Kim, Sang-Shik
    • Journal of Korea Foundry Society
    • /
    • v.35 no.4
    • /
    • pp.88-98
    • /
    • 2015
  • The effects of quenching and tempering temperatures on the tensile, impact and corrosion properties of A487 alloy cast with different C contents of 0.16, 0.19 to 0.23 wt.% were examined. The impact tests were conducted at $25^{\circ}C$ and $-60^{\circ}C$ and the immersion test was performed using 3.5% NaCl solution for 14 days. The quenching temperature affected the mechanical properties of A487 alloy cast, while the magnitude of change varied depending on the C content. The increase in tempering temperature showed the typical trend of decreasing tensile strength and increasing impact properties. The change in quenching and tempering temperature in this study did not affect the corrosion properties of A487 alloy significantly. The change in mechanical and corrosion properties of A487 with different C contents was discussed based on the microstructural and fractographic observation.

Finite Element Analysis and Experimental Confirmation of Warm Hydroforming Process (온간 하이드로포밍에 관한 유한요소해석 및 실험적 검증)

  • Kim, B.J.;Park, K.S.;Choi, K.H.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.277-280
    • /
    • 2006
  • The hydroformability of aluminum alloy sheets at elevated temperatures have been investigated in this study. It is necessary to analyze the variations of the mechanical properties that depend on the forming temperature and the heat conduction during warm hydroforming. Therefore, in this study a coupled simulation of plastic deformation and temperature distribution in the warm hydroforming process is performed and compared with experimental data. The multi-purpose code DEFORM-2D can handle this type of calculations but it takes high computation time if contact heat transfer between die, tube and pressure medium occurs. Experiments were conducted by high temperature tribometer(pin-on-disk) allowing measuring the friction coefficients of the aluminum alloys at several temperatures and these results are applied to the coupled simulation by which the optimal process parameters such as internal pressure and preset temperature on hydroformability can be determined. The comparison of the FE analysis with the experimental results has shown that hydroformability given by bulge height, and temperature distribution of the tube specimen make a little difference with the FE results but the trend predicted by simulation agrees well with experiments.

  • PDF

A Statistical Approach to Examine the Impact of Various Meteorological Parameters on Pan Evaporation

  • Pandey, Swati;Kumar, Manoj;Chakraborty, Soubhik;Mahanti, N.C.
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.3
    • /
    • pp.515-530
    • /
    • 2009
  • Evaporation from surface water bodies is influenced by a number of meteorological parameters. The rate of evaporation is primarily controlled by incoming solar radiation, air and water temperature and wind speed and relative humidity. In the present study, influence of weekly meteorological variables such as air temperature, relative humidity, bright sunshine hours, wind speed, wind velocity, rainfall on rate of evaporation has been examined using 35 years(1971-2005) of meteorological data. Statistical analysis was carried out employing linear regression models. The developed regression models were tested for goodness of fit, multicollinearity along with normality test and constant variance test. These regression models were subsequently validated using the observed and predicted parameter estimates with the meteorological data of the year 2005. Further these models were checked with time order sequence of residual plots to identify the trend of the scatter plot and then new standardized regression models were developed using standardized equations. The highest significant positive correlation was observed between pan evaporation and maximum air temperature. Mean air temperature and wind velocity have highly significant influence on pan evaporation whereas minimum air temperature, relative humidity and wind direction have no such significant influence.