• 제목/요약/키워드: Temperature Simulation

검색결과 4,529건 처리시간 0.028초

선박의 거주구역 화재시 연기거동 및 온도변화에 관한 시뮬레이션 연구 (A Simulation Study on Distributions of Smoke and Temperature in Accommdation on Shipboard Fires)

  • 김원욱;김종수;오세진;김성환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.293-294
    • /
    • 2006
  • This paper aims to simulate by FDS(Fire Dynamics Simulator) the distributions of temperature and smoke on fires in accommodations on boards. The paper focuses on analysis of temperature at fire occurrence and soot density. The purpose of this study is to predict the possibility of safe escape and efficient fire extinguishing method using fire simulation results.

  • PDF

벼의 횡류 연속식 건조 모델 개발 (Development of Continuous Cross-Flow Rice Drying Model)

  • 송대빈;고학균
    • Journal of Biosystems Engineering
    • /
    • 제22권3호
    • /
    • pp.279-288
    • /
    • 1997
  • This study was worked out to obtain fundamental data needed for developing a continuous type dryer. The drying process in a cross-flow type continuous dryer was expressed as partial differential equations, and a drying simulation model for predicting rice moisture content, rice temperature, drying air absolute humidity, drying air temperature was developed by using the finite difference method. To validate the performance of the drying simulation model, a prototype continuous dryer was constructed in this study. The size of the test dryer was one-tenth to that of a commercial continuous dryer. The difference in the outlet rice moisture content between the predicted values and the measured values was within 0.5%, that of outlet rice temperature was below $3^{\circ}C$, that of drying air temperature in drying bed was within $8^{\circ}C$ and that of relative humidity of outlet drying air was big because of the different measuring point. In addition, a drying simulation model for a actual size continuous dryer with double flow was developed in this study. This drying simulation model included the rice mixing effect in the middle of drying length. The difference of outlet moisture content between the predicted and the measured values showed below 0.5% in this study.

  • PDF

열원이 존재하는 작업장내 기류 및 온도장 예측 (Prediction of Airflow and Temperature Field in a Room With Convective Heat Source)

  • 정유진;하현철;김태형;유근종
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.78-84
    • /
    • 2001
  • A CFD simulation of airflow and temperature field in a heated room has been described in this paper. The thermal wall jet created by a radiator greatly influences the airflow pattern, temperature distribution. The area close La a heat source has a higher risk of air-borne contamination and imposes a harmful effect on occupants in that area. The predicted flow field, temperature results show good agreement with the measured data. As the results were compared with experimental data, the applicability of CFD was satisfactorily verified. Also, the CFD simulation can capture the natural convective flow features. If a CFD simulation is applied ventilation design with a heat source, An effective design will be attained. Further study is required to improve the accuracy of CFD simulation.

  • PDF

여객 열차 화재의 수치해석을 위한 민감도 분석 (A Study on Sensitivity Analysis for Numerical Solution of Passenger Train Fire)

  • 김우석;노삼규;정우성
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.1-6
    • /
    • 2009
  • 본 연구의 목적은 화재 예측모델로 널리 사용되는 FDS(Fire Dynamics Simulation) ver. 4.07을 여객열차 화재예측에 적용하기 위하여 민감도 분석(Sensitivity analysis)을 수행하는 것이다. 주요 분석 변수(Parameter)는 격자 크기(Grid size)와 Solid angle number이다. 분석결과, 격자크기의 변화는 온도(Plume temperature 상부층 온도(Upper layer temperature), 연기층 높이(Layer height)결과 값에 약$10{\sim}20%$의 차이를 갖게 하는 주요 민감도 변수이며 Solid angle number는 민감도에 영향을 크게 미치지 않는 것으로 분석되었다. 또한, 0.05m의 Grid size가 0.1m보다 결과 해상도가 높은 것으로 나타났다.

Thermal-hydraulic and load following performance analysis of a heat pipe cooled reactor

  • Guanghui Jiao;Genglei Xia;Jianjun Wang;Minjun Peng
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1698-1711
    • /
    • 2024
  • Heat pipe cooled reactors have gained attention as a potential solution for nuclear power generation in space and deep sea applications because of their simple design, scalability, safety and reliability. However, under complex operating conditions, a control strategy for variable load operation is necessary. This paper presents a two-dimensional transient characteristics analysis program for a heat pipe cooled reactor and proposes a variable load control strategy using the recuperator bypass (CSURB). The program was verified against previous studies, and steady-state and step-load operating conditions were calculated. For normal operating condition, the predicted temperature distribution with constant heat pipe temperature boundary conditions agrees well with the literature, with a maximum temperature difference of 0.4 K. With the implementation of the control strategy using the recuperator bypass (CSURB) proposed in this paper, it becomes feasible to achieve variable load operation and return the system to a steady state solely through the self-regulation of the reactor, without the need to operate the control drum. The average temperature difference of the fuel does not exceed 1 % at the four power levels of 70 %,80 %, 90 % and 100 % Full power. The output power of the turbine can match the load change process, and the temperature difference between the inlet and outlet of the turbine increases as the power decreases.

화력발전소 배관시스템의 운전 및 기후조건에 따른 에너지절감에 관한 시뮬레이션 (A simulation on the energy saving based on different temperature tracing method and weather condition in electrical power plant)

  • 한규일
    • 수산해양기술연구
    • /
    • 제50권1호
    • /
    • pp.67-74
    • /
    • 2014
  • Most of steam power plants in Korea are using the method of heating the feed water whenever the ambient temperature around the power plant area below $5^{\circ}C$ to prevent freezing water flowing in the pipe in winter time. But this kind of heat supplying system is not useful to save energy. If we take the method that the temperature of the each pipe is controled by direct measure of temperature by attaching sensor on the outside surface of the feed water tubes, then we can expect that a plenty of energy can be saved. In this study, the computer simulation is used to compare the energy consumption loads of both systems. Energy saving rate is calculated for the location of Incheon area in winter season. Four convection heat transfer coefficients for the ambient air and three initial flowing water temperature inside the tube were used. The result shows that the temperature control system using sensor represents more than 95% of energy saving rate in Incheon area. Even in the severe January weather condition, the energy saving rate is almost 75% in two days basis and even 83% in one day basis.

초기 입력 자료에 따른 WRF 기상장 모의 결과 차이 - ERA-Interim과 FNL자료의 비교 (Impact of Meteorological Initial Input Data on WRF Simulation - Comparison of ERA-Interim and FNL Data)

  • 문정혁;이화운;전원배;이순환
    • 한국환경과학회지
    • /
    • 제26권12호
    • /
    • pp.1307-1319
    • /
    • 2017
  • In this study, we investigated the impact of different initial data on atmospheric modeling results using the Weather Research and Forecast (WRF) model. Four WRF simulations were conducted with different initialization in March 2015, which showed the highest monthly mean $PM_{10}$ concentration in the recent ten years (2006-2015). The results of WRF simulations using NCEP-FNL and ERA-Interim were compared with observed surface temperature and wind speed data, and the difference of grid nudging effect on WRF simulation between the two data were also analyzed. The FNL simulation showed better accuracy in the simulated temperature and wind speed than the Interim simulation, and the difference was clear in the coastal area. The grid nudging effect on the Interim simulation was larger than that of the FNL simulation. Despite of the higher spatial resolution of ERA-Interim data compared to NCEP-FNL data, the Interim simulation showed slightly worse accuracy than those of the FNL simulation. It was due to uncertainties associated with the Sea Surface Temperature (SST) field in the ERA-Interim data. The results from the Interim simulation with different SST data showed significantly improved accuracy than the standard Interim simulation. It means that the SST field in the ERA-Interim data need to be optimized for the better WRF simulation. In conclusion, although the WRF simulation with ERA-Interim data does not show reasonable accuracy compared to those with NCEP-FNL data, it would be able to be Improved by optimizing the SST variable.

고성능 흡수냉동 사이클의 특성 시뮬레이션 (Simulation of the Characteristics of High-Performance Absorption Cycles)

  • 윤정인;오후규;이용화
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.231-239
    • /
    • 1995
  • This paper describes a computer simulation of the triple effect, water-lithium bromide absorption cooling cycles. The performance of the absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature, the working solution concentrations, the ratio of the amount of the weak solution to the high, middle and low temperature generators, and the temperature difference of each solution heat exchanger. The efficiency of different cycles has been studied and the simulation results show that higher coefficient of performance could be obtained for the parallel cycle of constant solution distribution rate. As a result of this analysis, the optimum designs and operating conditions were determined based on the operating conditions and coefficient of performance.

벼의 순환병류건조기(循環竝流乾操機)의 시뮬레이션 (Simulation of Rice Circulating Concurrent-flow Dryer)

  • 금동혁;이왕석
    • Journal of Biosystems Engineering
    • /
    • 제13권3호
    • /
    • pp.59-70
    • /
    • 1988
  • A computer simulation model for rice circulating concurrent-flow dryer was developed and verified by conduction a series of pilot-scale experiment. The effects of design parameter and operating conditions on dryer performance were analyzed by using simulation. The results indicated that the developed model was found suitable for analyzing operating characteristics. The other results from simulation also showed that; 1) an increse in the initial moisture content resulted in an increase in the drying rate and a reduction in the grain temperature and total energy requirements. 2) an increase in the drying air temperature resulted in an increase in the drying rate and grain temperature. 3) an increase in air flow rate resulted in an radical increase in drying rate, fan power requirements and total energy requirements but an radical decrease in final head rice yield. 4) an increase in the bed depth resulted in an increase in fan power requirements and a lowering of the final head rice yield.

  • PDF

유한체적법(FVM)의 시뮬레이션을 활용한 LED 벌브의 열 특성 고찰 (Investigation of the Thermal Characteristics of LED Bulb Utilizing Simulation of Finite Volume Method (FVM))

  • 박경민;문철희
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.1-8
    • /
    • 2014
  • Heat dissipation of the high power LED is a critical issue. To estimate the junction temperature of the LED chip is most important in characterizing the heat dissipation, but it is impossible to directly measure it. In this study, surface temperatures of the 12.8W LED bulb was measured for 5 points using a data logger and compared with the simulated results using a thermal simulator based on FVM (finite volume method) to secure a reliability of the simulation. Effects of some factors such as lens, emissivity and air inlet were investigated using simulation works and then the results were analysed.