• 제목/요약/키워드: Temperature Record

검색결과 164건 처리시간 0.025초

벼의 냉수피해 감소를 위한 관개수온 조사와 대책수립 (Measurement of Irrigation Water Temperature and Preventive Measure against Cold Watter Damage to Paddy Rice)

  • 정상옥
    • 한국농공학회지
    • /
    • 제41권1호
    • /
    • pp.52-59
    • /
    • 1999
  • Paddy rice is semi-tropical crop and requires warmirrigation water. If mean water temperature at the water source during the growing period is below 18$^{\circ}C$, sime kinds of water warming mechanism should be taken. In this study irrigation water temperature is measured and preventive measures to cold water damage on paddy rice are suggested. Field observations were performed at 100ha field area downtream of the Unmoon reservoir during the growing season of 1997. Land use, canal system, water temperature at irrigation canals. reservoir, and paddy fields were observed. In addition, growth and yield of the rice at selected plots were observed. Accordingly to the record, cold water damage occurred in this area due to the cold irrigation water supply in 1996. It did not occur because of the effective irrigation water management practice in 1997. However, several preventive measures such as pontoon intake system, using existing weir and construting a new warming pond, are suggested to prevent cold water damage in the future. If a new warming pond is construted to raise irrigation water temperature by 2 $^{\circ}C$, a pond area of 2.94 ha is required.

  • PDF

Variations of the Polar Temperature in the Lower Stratosphere during 1955-2004

  • Choi, Wookap;Kim, Dongjoon
    • 대기
    • /
    • 제18권4호
    • /
    • pp.429-439
    • /
    • 2008
  • The lower-stratospheric polar temperature in winter and spring for both hemispheres is investigated based on the NCEP/NCAR 50-year reanalysis data with respect to the strength of the stratospheric eddy heat flux. Both the polar temperature and the eddy heat flux show significant variation on the decadal and year-to-year time scales except during the Southern Hemisphere winter. The year-to-year variation in the polar temperature is mainly determined by the eddy heat flux convergence. The eddy heat flux convergence is compared with the diabatic heating rate obtained from a two-dimensional model. Radiative heating caused by absorption of solar radiation is comparable to the heating caused by the eddy heat flux convergence in the Southern Hemisphere. The effect of ozone depletion on diabatic heating has been found to be secondary in the Northern Hemisphere, even in March 1997 when the record depletion of ozone took place.

간섭파 자극후의 말초혈류량 변화 (The Effects of Interferential Current Stimulation on Peripheral Blood Flow)

  • 고경현;김주철;이충휘
    • 대한물리치료과학회지
    • /
    • 제1권1호
    • /
    • pp.121-127
    • /
    • 1994
  • The purpose of this study was to determine whether vasodilation occurs when interferential current is applied to the cervical sympathetic chain and peripheral sympathetic nerves. A digital thermometer was used to record skin temperature change. The protocols used for interferential stimulation were 90-100 Hz, applied for 20 minutes via two pairs of electrodes 1) to the throat and 2) to the forearm. Forty subjects were stimulated at each of the two sites. There was no significant correlation between inital skin temperature, sex or age and temperature change. Even though there was a statistically significant temperature increase with cervical sympathetic chain stimulation, this had no clinical vasodilatory effect. More research on interferential current stimulation is needed so that the potential benefits to normal subjects and patients is better understood.

  • PDF

High-Temperature-Tolerant Fungus and Oomycetes in Korea, Including Saksenaea longicolla sp. nov.

  • Nam, Bora;Lee, Dong-Jae;Choi, Young-Joon
    • Mycobiology
    • /
    • 제49권5호
    • /
    • pp.476-490
    • /
    • 2021
  • Global temperatures are steadily increasing, leading to significant changes in microbial diversity and ecology. In the present study, we isolated high-temperature-growing fungi and fungi-like group (Oomycota) strains from freshwater environments of Korea and identified them based on cultural, morphological, and multilocus phylogenetic analyses. As a result, we introduce Saksenaea (Fungi) isolates as a new species, Saksenaea longicolla sp. nov. and record Phytophthora chlamydospora and P. lagoariana (Oomycota) new to Korea. In the growth experiments, they exhibited high-temperature tolerance, which can grow at 35-40 ℃ but become inactive at 4 ℃ and below. This study confirms the presence of high-temperature-tolerant fungi and oomycetes in Korea and suggests that the Korean climate conditions are changing in favor of these species. This indicates that climate warming is altering microbial distributions in freshwater environments.

딥러닝을 활용한 마스크 착용 얼굴 체온 측정 시스템 (Masked Face Temperature Measurement System Using Deep Learning)

  • 이민정;김유미;임양미
    • 한국멀티미디어학회논문지
    • /
    • 제24권2호
    • /
    • pp.208-214
    • /
    • 2021
  • Since face masks in public were mandated during COVID-19, more people have taken temperature checks, with their masks on. The study has developed a contactless thermal camera that accurately measures temperatures of people wearing different kinds of masks, detect people wearing masks wrong, and record the temperature data. The built-in system that identifies people wearing masks wrong is what masks our contactless thermal camera differentiated from other thermal cameras. Also our contactless thermal camera can keep track of the number of mask wearers in different regions and their temperatures. Thus, the analysis of such regional data can significantly contribute to stemming the spread of the virus.

측정부 온도 부하에 따른 광용적맥파 파형 요동 특성 분석 (Analysis for the Fluctuation of the Photoplethysmographic Waveform derived by Temperature Stress of Measuring Position)

  • 이충근;신항식
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.304-309
    • /
    • 2015
  • Applicable range of Photoplethysmography (PPG) becomes wider as a non-invasive physiological measurement technique. However, PPG waveform is easy to be distorted by ambient light or vascular variation from temperature changes. Especially, irregular variation of PPG waveform caused by ambient temperature not only severely distorts the PPG, but also leads miss interpretation in clinical applications. Therefore, the investigation of between temperature and PPG waveform is quite important in using PPG. The purpose of this research is to quantify the PPG waveform characteristic and to investigate the waveform variation following the temperature change on measuring site. To quantify the fluctuation of PPG waveform, we use two techniques; detrended fluctuation analysis (DFA) and AC/DC analysis of PPG. We record PPG under temperature stress, which applied by medical use heat pack ($40^{\circ}C$) and ice pack ($0^{\circ}C$). Ten participants were applied to the experiment, and the result was evaluated to approve the temperature effect with statistical method, Wilcoxon signed rank test. The result shows that the AC component (p<0.05) and perfusion index DFS scale exponent (p<0.01) of PPG have the significance to temperature stress except for a DC component of PPG.

체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현 (Development for body temperature sensor and monitoring telemetry system)

  • 이정현;성기웅;김명남;조진호
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

평지붕 건물 축소모형의 지붕색에 대한 표면 온도의 비교평가: 쿨루프 성능평가 차원에서 (Comparative Evaluation of Surface Temperature among Rooftop Colors of Flat Roof Building Models : Towards Performance Evaluation of Cool Roof)

  • 류택형;엄정섭
    • KIEAE Journal
    • /
    • 제13권6호
    • /
    • pp.83-91
    • /
    • 2013
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. It is specifically proposed that the changing trends of rooftop surface temperature in the flat roof building model could be used effectively as an indicator to reduced cooling load reduced by cool roof since it can present stable temperature record, that is not influenced according to the nearby physical as well as human variables. The temperature of cool roof in summer was lower around $20^{\circ}C$, compared to the general roofs. Such a seasonal or daily comparative study for rooftop temperature in the building model will highlight that the cool roof efficiency could be calculated in much area-wide context according to rooftop color distribution in urban residential area. It is anticipated that this research output could be used as a valuable reference in identifying energy saving by cool roof since an objective monitoring has been proposed based on the rooftop temperature in the building model, fully quantitative performance of thermal infrared image.

자동차 후면 유리 열선의 열전달특성에 따른 성애제거 성능평가 및 성능검증 방법에 관한 연구 (A Study on the Performance Test and Verification of Heat Transfer characteristics in Automobile Rear Window Heater)

  • 전환영;이찬규;배효준;이상재
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.73-80
    • /
    • 2005
  • Both theoretical and experimental investigations were conducted to analyze defrosting behavior of a window heater operating in the low outdoor temperature($-20^{\circ}C$). To achieve this purpose, first a warm-chamber experiment($23^{\circ}C$) was performed to measure inner and outer surface temperature of the rear window(heated by the electric heater supplying 195 W) as functions of both time and position. Secondly, a cold chamber experiment was made to continuously record defrosting process of the frosted window. From the comparisons of the two experimental results, it was found that there was a similarity between the spatial distributions of both temperature and remaining frost. Thus, the temperature data from the warm-chamber experiments can be utilized to predict an expected zone covered with remaining frosts, and this approach can also be adopted in the inspection process in order to economically guarantee optimized performance of the window heater. Finally, an analytical model based on one-dimensional, steady-state heat transfer theories was proposed and successfully predicted the outer surface temperature of the rear window surrounded by cold air($-20^{\circ}C$) for the given operating conditions(heater power, inside and outside heat transfer coefficients, and surrounding air temperature, etc.).

  • PDF

양생온도 이력 기록장치를 이용한 현장타설 콘크리트의 품질검사 (Quality Inspection for Cast-In-Place Concrete with the Device to Record Curing Temperature)

  • 조영권;김관호;김명원;이준구;유정훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.351-354
    • /
    • 2005
  • Quality of concrete required to achieve the desired levels of strength and durability depend on the effectiveness of the curing method. During cold weather, the concrete at the time of placement should be taken to prevent damage to concrete due to freezing. Since the cement-water reaction is exothermic by nature, the temperature within mass concrete can be quite high. The temperature control for massive sections should be taken more careful than for shallow sections. However, in the constructing hydraulic structures, the curing temperature control for concrete had been very difficult to be taken in a proper way because the conditions constructing them are poor and contractors are small enterprises. For several. reasons including above, Rural Research Institute has developed a device and program for recording curing temperature history in cold weather concrete and mass. As there are two major advantages of the device, namely cheapness and availability, this program and device has been recommended to the use of curing temperature control in cold weather concrete and mass.

  • PDF