Fire-after-earthquake resistance of steel structures using rotational capacity limits

  • Pantousa, Daphne;Mistakidis, Euripidis
    • Earthquakes and Structures
    • /
    • v.10 no.4
    • /
    • pp.867-891
    • /
    • 2016
  • This paper addresses numerically the behavior of steel structures under Fire-after-Earthquake (FAE) loading. The study is focused on a four-storey library building and takes into account the damage that is induced in structural members due to earthquake. The basic objective is the assessment of both the fire-behavior and the fire-resistance of the structure in the case where the structure is damaged due to earthquake. The combined FAE scenarios involve two different stages: during the first stage, the structure is subjected to the ground motion record, while in the second stage the fire occurs. Different time-acceleration records are examined, each scaled to multiple levels of the Peak Ground Acceleration (PGA) in order to represent more severe earthquakes with lower probability of occurrence. In order to study in a systematic manner the behavior of the structure for the various FAE scenarios, a two-dimensional beam finite element model is developed, using the non-linear finite element analysis code MSC-MARC. The fire resistance of the structure is determined using rotational limits based on the ductility of structural members that are subjected to fire. These limits are temperature dependent and take into account the level of the structural damage at the end of the earthquake and the effect of geometric initial imperfections of structural members.

A Study on the Linear Counting Ratemeter (선형 계수율계에 관한 연구)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.6
    • /
    • pp.8-16
    • /
    • 1971
  • This paper describes the transistorized linear counting ratemeter which can be uses to indicate on the meter or record the counting rates of the nuclear radiations produced from the atomic reactor or from the radio isotopes. Tte feature of this ratemeter is the use of the transistor chopper for good stabilization. At the input stage of the a. c. amplifier a composite emitter follower buffer stage has been used to give the high input impedance. A hybrid parameter equivalent circuit was modeled for the analysis of this buffer stage. The counting rates can be linearly measured from few CPS up to 100KCPS in 4 ranges. The resolution is less than 0.5$\mu$sec and the output drift at the room temperature with 7-hour continuous operation is in the order of $\pm$0.5$\mu$A.

  • PDF

Effect of Dissolved Gases on Liquid Droplet Heat Transfer Enhancement (액적 열전달 향상에 미치는 Dissolved 가스의 영향에 관한 연구)

  • Lee, Jung-Ho;Kim, Jung-Ho;Kiger, Kenneth T.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1491-1498
    • /
    • 2003
  • Droplet evaporation can be used to transfer large amounts of energy since heat is transferred across a thin liquid film. Spreading the drop over a larger area can enhance this heat transfer. One method of accomplishing this is to dissolve gas into the liquid. When the drop strikes the surface, a gas bubble nucleates and can grow and merge within the liquid, resulting in an increase in the droplet diameter. In this study, time and space resolved heat transfer characteristics for a single droplet striking a heated surface were experimentally investigated. The local wall heat flux and temperature measurements were provided by a novel experimental technique in which 96 individually controlled heaters were used to map the heat transfer coefficient contour on the surface. A high-speed digital video camera was used to simultaneously record images of the drop from below. The measurements to date indicate that significantly smaller droplet evaporation times can be achieved. The splat diameter was observed to increase with time just after the initial transient dies out due to the growth of the bubble, in contrast to a monotonically decreasing splat diameter for the case of no bubbles. Bursting of the bubble corresponded to a sudden decrease in droplet heat transfer.

  • PDF

Implementation of Low-Power Ubiquitous Health System based on Real-Time Embedded Linux using ZigBee wireless communication (ZigBee를 이용한 실시간 임베디드 리눅스 기반의 저전력형 U-Health 시스템 구현)

  • Kwon, Jong-Won;Ayurzana, Odgerel;Park, Yong-Man;Koo, Sang-Jun;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.436-438
    • /
    • 2007
  • As the sensors and communication technology get advance, the remote health diagnosis for patients and senior persons at home are possible now without visiting doctors in hospitals. A low-power ubiquitous health check device was developed adapting Real-Time Embedded Linux is developed. This ubiquitous device is consisted of three sensors. The wrist type health checking terminal acquires periodically the health data by using a blood pressure sensor, a pulse sensor and a body temperature sensor. It transmits the health data to the access point located at the home center through the ZigBee wireless communication modem. This health data collector or access point device sends the data again to the main server operated in a hospital or health care organization. The health server control continuously the input data and sends an alarm signal to the assigned. doctor and responsible persons using cellular SMS when any dangerous events occur. This wrist type health check device has an embedded linux OS using Intel PAX255 MPU. The developed U-Health system is applicable for checking patients health in remote at home. And their family or related persons in remote site can check the patients health status at any time. They can be assured by receiving SMS record and alarm of emergency case which is transmitted from the health server.

  • PDF

The Effect of Mixture Component in a Gasoline Engine on Output (The Effect of Ignition Delay and Combustion Period) (가솔린 기관(機關)의 혼합기(混合氣) 성분(成分)이 출력(出力)에 미치는 영향(影響) (점화지연(点火遲延) 및 연소(燃燒) 기간(期間)에 미치는 영향(影響)))

  • Song, J.I.
    • Journal of ILASS-Korea
    • /
    • v.3 no.1
    • /
    • pp.19-26
    • /
    • 1998
  • The effect of mixture component makes a nelay time and a long total combustion period $\tau_{p\;max}$. The flame propagation delay $\tau_{df}$ was determined by the record of current ion. The pressure release delay $\tau_{dp}$ and $\tau_{p\;max}$ were determined by the indicated pressure diagram in constant volume of the combustion chamber. The results are as follows: 1) The ignition delay $\tau_t$ time takes the minimum value around $\Phi=1.15$. 2) $\tau_{df}$ and $\tau_t$ time increased according to the increases of the concentrated dilution gases, because the adiabatic flame temperature decreased due to the increases of the heat capacity. But dilution gases have little effect on flame nucleus formation delay 3) The relation between $\tau_t$ time and reciprocal laminar burning velocity is almost linear. 4) The increase of the propagation length is accompanied with increased ratio of the $\tau_{df},\;\tau_{dp},\;\tau_{t},\;\tau_{p\;max}$.

  • PDF

EFFECTS OF MECHANICAL PROPERTY VARIABILITY IN LEAD RUBBER BEARINGS ON THE RESPONSE OF SEISMIC ISOLATION SYSTEM FOR DIFFERENT GROUND MOTIONS

  • Choun, Young-sun;Park, Junhee;Choi, In-Kil
    • Nuclear Engineering and Technology
    • /
    • v.46 no.5
    • /
    • pp.605-618
    • /
    • 2014
  • The effects of variability of the mechanical properties of lead rubber bearings on the response of a seismic isolation system are investigated. Material variability in manufacturing, aging, and operation temperature is assumed, and two variation models of an isolation system are considered. To evaluate the effect of ground motion characteristics on the response, 27 earthquake record sets with different peak A/V ratios were selected, and three components of ground motions were used for a seismic response analysis. The response in an isolation system and a superstructure increases significantly for ground motions with low A/V ratios. The variation in the mechanical properties of isolators results in a significant influence on the shear strains of the isolators and the acceleration response of the superstructure. The variation provisions in the ASCE-4 are reasonable, but more strict variation limits should be given to isolation systems subjected to ground motions having low A/V ratios. For application of seismic isolation systems to safety-related nuclear structures, the variation in the material and mechanical properties of the isolation system should be properly controlled during the manufacturing and aging processes. In addition, special consideration should be given to minimize the accidental torsion caused by the dissimilarity in the stiffness variations of the isolators.

Structures of a Solar Filament Observed with FISS on 2010 July 29

  • Song, Dong-Uk;Chae, Jong-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.38.2-38.2
    • /
    • 2011
  • In general, solar filaments are divided into two parts; one spine and several barbs. Barbs are seen as if they protrudes from the spine. Until now there are many controversies about the structures of a barb and spine. Recently, New Solar Telescope was installed at Big Bear Solar Observatory. Its clear aperture is about 1.6m and it is the largest telescope among ground-based solar telescopes. Fast Imaging Solar Spectrograph (FISS) developed by SNU and KASI was also installed in a vertical optical table in Coude room of the 1.6m NST. It is simultaneously able to record two lines; $H{\alpha}$ and Ca II 8542A lines. On 2010 July 29, we observed a portion of a solar filament located in northern hemisphere with FISS and it had a well-developed barb. And we also observed a potion of a spine. In order to analyze the data, we used the cloud model and obtained physical quantities of the solar filament. Temperature of the solar lament ranged between 4500K and 12000K and non-thermal velocity ranged between 3km/s and 6.5km/s. By comparing physical quantities of a barb and spine, we try to understand these structures of the solar filament.

  • PDF

Impact of maternal crowd on the reproductive performance of an ecto-pupal parasitoid Nesolynx thymus (Hymenoptera: Eulophidae)

  • Siddaiah, Aruna Ambadahalli;Danagoudra, Manjunath
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.29 no.1
    • /
    • pp.128-134
    • /
    • 2014
  • Nesolynx thymus Girault (Hymenoptera: Eulophidae) is one among 20 hymenopteran parasitoids reported to attack the uzi fly, Exorista bombycis, which in turn infests the silkworm, Bombyx mori accounting a cocoon yield loss of 10-20%. A host of factors viz., age and size of host, age and size of parasitoid, availability of host, temperature and quality of host are reported to influence the reproductive efficiency of the parasitoids. In the present study an attempt was made to record the influence of foraging parasitoid density on their reproductive performance. Three day-old uzi pupae were offered to varying numbers (1 - 10) of 2 day old Nesolynx thymus adults for parasitization. The progeny production per pupa (84.44 - 132.77) increased significantly with increase in the number of foraging parasitoid adults (1 - 10) however, progeny production per female decreased. The sex ratio (M : F) (1:25.49 - 1:1.53) decreased significantly with increase in foraging parasitoid adults. The morphometric parameters except female abdomen width of first generation parasitoid showed significant negative correlation with number of foraging adults. However, correlation between the parasitoid size in first generation and their reproductive performance was nonsignificant.

Analysis of habitat characteristics of mosquitoes in Danwongu, Ansan city, Korea, based on civil complaint data

  • KIM, Jeong Eun;BAE, Yeon Jae;LEE, Hwang Goo;KIM, Dong Gun
    • Entomological Research
    • /
    • v.48 no.6
    • /
    • pp.540-549
    • /
    • 2018
  • Climate change due to global warming and changes in land use increase the development time and distribution, as well as the abundance, of mosquitoes, thereby negatively affecting human life and health. In this study, we investigated the habitat characteristics of mosquito occurrence sites in Danwon-gu, Ansan city, Korea, based on a daily record of civil pest complaints lodged at the Danwon-gu Community Health Center. We considered two types of factors (natural and artificial) known to affect mosquito occurrence. We confirmed a total of 554 cases of mosquito occurrence from March 2014 to August 2017. The total study area was $49.11km^2$, with urban areas constituting the largest proportion. Additionally, we investigated habitat preferences of mosquitoes in terms of terrain factors; generally, mosquitoes occurred at low elevations and on low slopes. Regarding the preference of oviposition sites, mosquitoes occurred at higher rates near streams and crops lands. The rate of mosquito occurrence tended to increase in areas with dense human populations. Regarding climatic factors, the rate of mosquito occurrence increased in areas with high temperature and low precipitation.

Warm Start Up Time Reduction Through the Increase of Boiler Water Circulating Pump Inlet Water Temperature Rate of the Thermal Power Plant (관수온도 상승률 증가에 의한 발전용 보일러의 온간기동시간 단축에 관한 연구)

  • Kang, Hee-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2014
  • The national capacity of electricity of Korea was 81,737 MW and the peak demand was renewed by the record of 71,230 MW in 2012 which has been increasing since the first lighting ceremony had taken place in the Royal Palace(Kyung-Bok Goong) in 1887. Aa the counteract on the rapid increasing of the demand, Korean government is constructing and operating the high capacity nuclear and thermal power plants, however, the operating reserve on weekdays is small while those of weekends are more than 40% of capacity, so they are providing the pumped-storage power plants with the surplus electricity during weekends and operating the power plants which cost higher production price and located in the capital area with WSS (Weekly Start and Stop) mode including the Seoul Thermal Power Plant. Since the Seoul Thermal Power Plant is spending huge amount of expenses for more than 30 times of the WSS annually due to the high production cost even though it is in Seoul, the core of the demand, I chose the power plant unit #5 which was on the grid in 1969 for the case to confirm reducing 23% of the warm start-up time by applying the "Start-up time management program", and that reducing 35% of the water temperature increasing time by accelerate the increasing rate of the inlet temperature of the water circulating pump.

  • PDF