• Title/Summary/Keyword: Temperature Monitor

Search Result 683, Processing Time 0.026 seconds

Design and Implementation of M2M-based Smart Factory Management Systems that controls with Smart Phone (스마트폰과 연동되는 M2M 기반 스마트 팩토리 관리시스템의 설계 및 구현)

  • Park, Byoung-Seob
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.4
    • /
    • pp.189-196
    • /
    • 2011
  • The main issues of the researches are monitoring environment such as weather or temperature variation and natural accident, and sensor gateways which have mobile device, applications for mobile health care. In this paper, we propose the SFMS(Smart Factory Management System) that can effectively monitor and manage a green smart factory area based on M2M service and smart phone with android OS platform. The proposed system is performed based on the TinyOS-based IEEE 802.15.4 protocol stack. To validate system functionality, we built sensor network environments where were equipped with four application sensors such as Temp/Hum, PIR, door, and camera sensor. We also built and tested the SFMS system to provide a novel model for event detection systems with smart phone.

Out-of-Plane Deformation Measurement of TPS in Vehicle Using ESPI (ESPI를 이용한 자동차 TPS 면외변형 계측)

  • Han, Sang-Kil;Ham, Hyo-Shick;Ham, Sang-Hyun;Lee, Jong-Hwang;Jung, Won-Wook;Lee, Chang-Hee;Lee, Sang-Bong;Choi, Sung-Eul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.423-428
    • /
    • 2010
  • In this paper, we analyzed the characteristics of thermal deformation of the TPS which is a core part of engine in vehicle by measuring out-of-plane deformation using ESP!. Inspection area of a test piece was minimized to 5 cm by 5 cm by using a high resolution CCD and a zoom lens. 4-step phase shifting method was used along with phase unwrapping algorithm to get a continuous phase map, configurations and deformations were displayed as 3D images. When heating the test pieces while maintaining the temperature at about $70^{\circ}C$, the out-of-plane deformations were measured. The results showed that a test piece with longer distance traveled tends to show larger thermal deformation, we could observes a convex shaped deformation on the surface. The inner defect sample, we could monitor discontinuous pattern phase map, and a concave shaped deformation on the surface.

Early Alterations of Chlorophyll Fluorescence by Light-Chilling in Cucumber (Cucumis sativus) Leaves and Their Usage as Stress Indicators (오이 잎에서 저온 광저해에 의한 형광유도과정의 초기 변이와 스트레스 지표)

  • Ha, Suk-Bong;Young-Jae Eu;Choon-Hwan Lee
    • The Korean Journal of Ecology
    • /
    • v.19 no.2
    • /
    • pp.151-163
    • /
    • 1996
  • To investigate the early symptoms of light-chilling, alterations of chlorophyll fluorescence transients were monitored in cucumber (Cucumis sativus L. cv. Ilmichungjang) leaves. During 24 h chilling, decreases in (Fv)m/Fm, qE and qQ, and an increase in Fo were observed. The chilling effects were not recovered at room temperature, and a significant increase in Fo was observed during the recovery period. After 6 h chilling, ‘dip’(D) level of the transients became obscure, and the negative slope after ‘peak’(P) disappeared. The first derivative (dFv/dt) of the fast fluorescence rise curve was used to obtain more accurate information about the changes in the transients. The maximal rate of the fluorescence increase in the D-p rise curve (Fr) has been the most frequently used chilling stress indicator. However, a correct value of Fr could not be measured when the D level became obscure. This problem was overcome by introducing a new indicator, HFr (dFv/dt at Fv = 1/2 (Fv)m), and HFr gave very similar values to Fr. To monitor the changes in curvature around D level, another new parameter, ${\Delta}S$(D-Fr), was also introduced. These three parameters decreased very sensitively during light-chilling. In addition, increases in these parameters were observed during the first 2 h chilling, but this increase in Fr was also observed in pea leaf discs dark-chilled for 15 min, suggesting that this very early change is a common response to chilling in both pea and cucumber leaves. Quenching coefficients were also very sensitive to chilling, especially qE. Discussion on the usage of these parameters as chilling stress indicators is given in the text.

  • PDF

Analysis of the Satisfaction with Computer Based Test Program and Test Environment in Medical School (의과대학의 컴퓨터기반시험 프로그램 및 시험환경 만족도 분석)

  • Kim, Soon Gu;Lee, Aehwa;Hwang, Ilseon
    • Korean Medical Education Review
    • /
    • v.22 no.3
    • /
    • pp.198-206
    • /
    • 2020
  • This study aimed to identify needed improvements to current evaluation methods in medical school computer-based test (CBT) programs and test environments. To that end, an analysis of the importance and satisfaction was conducted through a survey of 3rd and 4th year medical students who had sufficient experience with CBT programs. Importance performance analysis methodology using the correlation coefficient was applied to assess average satisfaction and importance. The first quadrant (keep up the good work) was a factor of review and time management and test facilities among the conveniences of the CBT program. The second quadrant (concentrate here) was a factor of the convenience of the CBT program and computer monitor and chair factor within the test facilities. The third quadrant (low priority) was a factor of cheating and computer failure. The fourth quadrant (possible overkill) was the location, spacing, and temperature factors of the test facilities. Improvements are needed to reduce 'eye fatigue' and help students focus and understand the questions in the CBT programs. It is necessary to improve computer monitors, desks and chairs, and consider the subject's body type and manager in order to cope with computer breakdown and peripheral failures. Spare computers are needed. These findings are meaningful in that they have been able to identify factors that require improvement in the CBT program and test environment resulting from changes in assessment tools.

Development of On-line Monitoring Techniques for Fumaric Acid and Succinic Acid by Flow Injection Analysis (흐름주입분석기술에 의한 푸마르산과 숙신산의 모니터링 기술 개발)

  • 손옥재;김춘광;이종일
    • KSBB Journal
    • /
    • v.18 no.5
    • /
    • pp.377-384
    • /
    • 2003
  • On-line monitoring techniques for fumaric acid and succinic acid were developed by flow injection analysis (FIA). For the determination of fumaric acid, two enzymes, fumarase and malic dehydrogenase were immobilized on VA-epoxy Biosynth E3-carrier and integrated into a FIA-system with a fluorescence detector. For the analysis of succinic acid, isocitrate lyase and isocitrate dehydrogenase were also immobilized on VA-epoxy polymer support and used in a FIA system. The immobilized enzymes in two FIA systems were characterized systematically, e.g. optimum pH and temperature, inhibitory effects etc. Two FIA systems were also used to on-line monitor the concentrations of fumaric acid and succinic acid in biotechnological processes. Good agreement between on-line monitored data and off-line data measured by HPLC showed extensive application of the FIA systems in bioprocesses.

Design and Implementation of a ubiquitous health care system (유비쿼터스 헬스 케어 시스템의 설계 및 구현)

  • Kim, Jeong-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.921-924
    • /
    • 2007
  • In this paper, we have implemented a ubiquitous healthcare system that can measure and check human's health in anytime and anywhere. The implemented prototype are composed of both front-end and back-end. The front-end have several groups: environment sensor group such as temperature, humidity, photo, voice sensor, health sensor group such as blood pressure, heart beat, electrocardiogram, spo2 sensor, gateway for wired/wireless communication, and RFlD reader to identify personal. The back-end has a serial forwarder to propagate measurment results, monitor program, and medical information server. The implemented sensor node constructs a sensor network using the Zigbee protocol and is ported the TinyOS. The data gathering base node is linux-based terminal that can transfer a sensed medial data through wireless LAN. And, the medical information server stores the processed medical data and can promptly notify the urgent status to the connected medical team. Through our experiments, we've confirmed the possibility of ubiquitous healthcare system based on sensor network using the Zigbee.

  • PDF

Early Life History of the Sevenband Grouper, Epinephelus septemfasciatus from Korea

  • Park, Jae-Min;Cho, Jae-Kwon;Han, Kyeong-Ho;Kim, Na-Ri;Hwang, Hyung-Kyu;Kim, Kyong-Min;Myeong, Jeong-In;Son, Maeng-Hyun
    • Development and Reproduction
    • /
    • v.18 no.1
    • /
    • pp.13-23
    • /
    • 2014
  • This study is conducted to monitor the morphological developmental features of the egg development, larvae and juvenile of Epinephelus septemfasciatus, the fertilized eggs were gotton using artificial insemination. Matured parents are collected from marine caged fish farms in Geomun-ri, Samsan-myeon, Yeosu-si, Jeollanamdo Korea in June 2012. The fertilized eggs were pelagic eggs containing one oil globule, and measured 0.81~0.89 mm ($0.85{\pm}0.04mm$, n=50) in diameter. In regard to rearing environment, the water temperature is $21.0{\sim}23.0^{\circ}C$ and the salinity is 32.0~33.2‰. Hatching was observed from 48 hours after fertilization, the mouth and anus of prelarvae was not opened but had egg yolk at newly hatched. 4 days after hatching, the mouth and anus of postlarvae was opened and began to eat Rotifer and was measured 2.40~2.49 mm ($2.45{\pm}0.03mm$ n=10) in total length. 12 days after hatching, postlarvae was measured 3.77~4.67 mm ($4.27{\pm}0.33mm$) in total length, its the second pole tide of dorsal fin and the first pole tide of pelvic fin was extended longitudinally. 71 days after hatching, juvenile was measured 40.5~45.4 mm ($42.6{\pm}2.04mm$) in total length. Seven bands were observed in body, and pole tides of dorsal and pelvic fins were shortened.

Development of a Respiration Sensor Using Plastic Optical Fiber (플라스틱 광섬유를 이용한 호흡센서의 개발)

  • Yoo, Wook-Jae;Baek, Ji-Yun;Cho, Dong-Hyun;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Cho, Young-Ho;Park, Byung-Gi;Moon, Joo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.489-494
    • /
    • 2009
  • In this study, we fabricated a plastic optical fiber based sensor which can monitor the respiration of a patient. The circumference changes of the abdomen were measured using a mirror, a light source and optical detectors because the circumferences of the abdomen could be varied with respiration. The intensity of the reflected lights were measured according to the changes of distance between mirror and plastic optical fiber connected to a light source and a photodiode-amplifier system using a Y-coupler. The respiration signals of fiber-optic sensor system were compared with those of the respiratory and temperature transducers of the $BIOPAC^{(R)}$ system. It is expected that a fiber-optic respiration sensor could be developed for real time respiration monitoring during MRI procedure based on this study.

Fabrication and characteristics of NOx gas sensors using WO3 and In2O3 thick films to monitor air pollution

  • Son, M.W.;Choi, J.B.;Hwang, H.I.;Yoo, K.S.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.263-268
    • /
    • 2009
  • With the increasing number of automobiles, the problem of air pollution from the exhaust gases of automobiles has become a critical issue. The principal gases that cause air pollution are nitrogen oxide or NO$_x$(NO and NO$_2$), and CO. Because NO$_x$ gases cause acid rain and global warming and produce ozone(O$_3$) that leads to serious metropolitan smog from photochemical reaction, they must be detected and reduced. Mixtures of WO$_3$ and $In_2O_3$(WO$_3$:$In_2O_3$=10:0, 7:3, 5:5, 3:7, and 0:10 in wt.%), which are NO$_x$ gas-sensing materials, were prepared, and thick-film gas sensors that included a heater and a temperature sensor were fabricated. Their sensitivity to NO$_x$ was measured at 250$\sim$400$^{\circ}C$ for NO$_x$ concentrations of 1$\sim$5 ppm. The $In_2O_3$ thick-film sensor showed excellent sensitivity($R_{gas}/R_{air}$=10.22) at 300$^{\circ}C$ to 5-ppm NO. The response time for 70 % saturated sensitivity was about 3 seconds, and the sensors exhibited very fast reactivity to NO$_x$.

Breakdown Properties in Physiological Saline by High Voltage Pulse Generator

  • Byeon, Yong-Seong;Song, Ki-Baek;Uhm, Han-Sup;Shin, Hee-M.;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.333-333
    • /
    • 2011
  • We have investigated the breakdown properties in liquids by high voltage pulse system. High voltage pulse power system is consisted of the Marx-generator with two capacitors (0.5 ${\mu}F$, withstanding voltage is 40 kV), to which the charging voltage can be applied to maximum 30 kV DC, spark gap switch and charging resistor of 20 $M{\Omega}$. We have made use of tungsten pin electrodes of anode-cathode (A-K), which are immersed into the liquids. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current monitor (IPC CM-1.S). Especially the high speed breakdown or plasma propagation characteristics in the pulsed A-K gap have been investigated by using the high speed ICCD camera. We have measured the electron temperature through the Boltzmann plot method from the breakdown spectrums. Here the A-K gap has been changed by 1 mm, 2 mm, and 3 mm. The used liquids are distilled water and solution of salt (0.9 %). The output voltage and current signals at breakdown in distilled water are shown to be bigger than those in saline solution. The breakdown voltage and current characteristics in liquids will be discussed in accordance with A-K gap distances. It is also found that the electron temperatures and plasma densities in liquids are decreased in conformity with A-K gap.

  • PDF