• 제목/요약/키워드: Temperature Evaluation

검색결과 4,698건 처리시간 0.027초

도로변 가로녹지 유형이 기상에 미치는 영향 (A Study on the Temperature Reduction Effect of Street Green Area)

  • 김정호;최원준;윤용한
    • 한국환경과학회지
    • /
    • 제26권12호
    • /
    • pp.1363-1374
    • /
    • 2017
  • Global climate change caused by industrialization has caused abnormal weather conditions such as urban temperatures and tropical nights, urban heat waves, heat waves, and heavy rains. Therefore, the study tried to analyze climate conditions and weather conditions in the streets and analyze climate factors and meteorological factors that lead to inconvenience to citizens. In the case of trees, the overall temperature, surface temperature, solar irradiance, and net radiation were measured low, and the temperature was lower in the Pedestrian road than in roads. The dry bulb temperature, the black bulb temperature, and the wet bulb temperature for the thermal evaluation showed the same tendency. In the case of thermal evaluation, there was a similar tendency to temperature in WBGT, MRT, and UTCI, and varied differences between types. Although the correlation between the meteorological environment and the thermal environment showed a statistically significant significance, the difference between the measured items was not significant. The study found that the trees were generally pleasant to weather and thermal climate in the form of trees, and the differences were mostly documented.

Effects of heat stress on body temperature, milk production, and reproduction in dairy cows: a novel idea for monitoring and evaluation of heat stress - A review

  • Liu, Jiangjing;Li, Lanqi;Chen, Xiaoli;Lu, Yongqiang;Wang, Dong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권9호
    • /
    • pp.1332-1339
    • /
    • 2019
  • Heat stress exerts a substantial effect on dairy production. The temperature and humidity index (THI) is widely used to assess heat stress in dairy operations. Herein, we review the effects of high temperature and humidity on body temperature, feed intake, milk production, follicle development, estrous behavior, and pregnancy in dairy cows. Analyses of the effects of THI on dairy production have shown that body temperature is an important physiological parameter in the evaluation of the health state of dairy cows. Although THI is an important environmental index and can help to infer the degree of heat stress, it does not reflect the physiological changes experienced by dairy cows undergoing heat stress. However, the simultaneous measurement of THI and physiological indexes (e.g., body temperature) would be very useful for improving dairy production. The successful development of automatic detection techniques makes it possible to combine THI with other physiological indexes (i.e., body temperature and activity), which could help us to comprehensively evaluate heat stress in dairy cows and provide important technical support to effectively prevent heat stress.

해상용 태양열 시스템 개발을 위한 일사량 평가 (The Radiation Evaluation for Development of Solar System by Using Solar on the Sea)

  • 강일권
    • 한국해양공학회지
    • /
    • 제14권2호
    • /
    • pp.13-18
    • /
    • 2000
  • Recently due to the environmental pollution and the requirement for the substitute energy the interest for development of the solar energy system has been highly escalated It has been approved that the solar energy is a very useful on e because of purity and low cost. Some studies about the evaluation of solar radiation on the land has been carried out but few studies on the sea. This paper deals with a study on the evaluation of solar radiation on the sea. The experiments were carried out on the training vessel on the adjacent water of Korea Japan and China for twenty days. The distributions of solar radiation from the sea were changed into nonlinear in from according to the temperature. The solar radiation on the sea has a great influence on the velocity of wind as well as the temperature The distribuition of solar radiation has higher values on the track of the coastal sea than the open sea at same conditions.

  • PDF

4kW급 상용차량용 전력전자 냉방장치의 열 환경 성능평가 (Thermal environmental performance evaluation of 4kW power electronic cooling system for commercial vehicle)

  • 한근우;김성곤;이충훈;최명현;정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.290-291
    • /
    • 2017
  • This study deals with an evaluation method for testing the robustness of the 4 kW commercial power electronic cooling system to the thermal environment. The power electronic cooling system consists of a cascaded push-pull DC / DC converter, a three-phase DC / AC inverter, and an electric compressor. The system manufactured by the thermal environment evaluation test (heat distribution test, thermal impact test, high temperature operation test, temperature cycle test, low temperature operation test) for the commercial electric power cooling system for commercial vehicle proves that it is robust against thermal environment.

  • PDF

최적화 기법을 활용한 열전달계수의 측정 (A study on the Evaluation of Heat Transfer Coefficient by Optimization Algorithm)

  • 김정태;임채호;최정길
    • 소성∙가공
    • /
    • 제15권9호
    • /
    • pp.679-685
    • /
    • 2006
  • New method for evaluation of heat transfer coefficient is proposed. In general, many researchers have been studied about inverse problem in order to calculate the heat transfer coefficient on three-dimensional heat conduction problem. But they can get the time-dependent heat transfer coefficient only through inverse problem. In order to acquire temperature-dependent heat transfer coefficient, it requires much time for numerous repetitive calculation and inconvenient manual modification. In order to solve these problems, we are using the SQP(Sequential Quadratic Programming) as an optimization algorithm. When the temperature history is given by experiment, the optimization algorithm can evaluate the temperature-dependent heat transfer coefficient with automatic repetitive calculation until difference between calculated temperature history and experimental ones is minimized. Finally, temperature-dependent heat transfer coefficient evaluated by developed program can used on various heat transfer problem.

유도 전동기의 열적 과도상태의 해석 (A Study on the Thermal Transient Analysis of Induction Motors)

  • 천장성;김형섭;이철균;한송엽;원종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.59-62
    • /
    • 1993
  • The evaluation of the temperature of the motor in operation is necessary for smaller and lighter design of motors and for the determination of insulation class. And the evaluation of the temperature in thermal transient state is necessary for the determination of the intermittent rating and the protection from the thermal overload. The temperature can be calculated exactly by considering the loss distribution, the thermal resistances and the thermal capacities dependent on temperature. Using the detailed thermal equivalent circuit, the temperature of any local part of the motor can be evaluated. The comparison between the calculated results and the experiments is performed to verify the validity of the analysis.

  • PDF

여름철 실내외 온도차에 따른 인체의 온열쾌적성 평가 (Evaluation of Thermal Comfort on Temperature Differences between Outdoor and Indoor Thermal Conditions in Summer)

  • 금종수;김동규;최광환;이낙범;임재중;최호선;배동석
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.890-896
    • /
    • 2002
  • Purpose of this study is to clarify the evaluation of thermal comfort based on temperature differences between outdoor and indoor thermal conditions in summer. The experiments were performed to evaluate temperature difference between indoor and outdoor thermal conditions (29, 31, $33^{\circ}$) by physiological and psychological responses of human. According to physiological responses, TSV (thermal sensation vote) and CSV (comfort sensation vote) and psychological responses, ECG (electrocardiogram), MST (mean skin temperature) of human, it was clear that the optimum temperature difference is about $5^{\circ})\;and\;7^{\circ}$).

Statistical Evaluation of Fracture Characteristics of RPV Steels in the Ductile-Brittle Transition Temperature Region

  • Kang, Sung-Sik;Chi, Se-Hwan;Hong, Jun-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.364-376
    • /
    • 1998
  • The statistical analysis method was applied to the evaluation of fracture toughness in the ductile-brittle transition temperature region. Because cleavage fracture in steel is of a statistical nature, fracture toughness data or values show a similar statistical trend. Using the three-parameter Weibull distribution, a fracture toughness vs. temperature curve (K-curve) was directly generated from a set of fracture toughness data at a selected temperature. Charpy V-notch impact energy was also used to obtain the K-curve by a $K_{IC}$ -CVN (Charpy V-notch energy) correlation. Furthermore, this method was applied to evaluate the neutron irradiation embrittlement of reactor pressure vessel (RPV) steel. Most of the fracture toughness data were within the 95% confidence limits. The prediction of a transition temperature shift by statistical analysis was compared with that from the experimental data.

  • PDF

공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가 (Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment)

  • 이철희;나환선;정훈;김강식
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

안전조치 검증장비의 극한 온도환경 적용성 평가 (Evaluation of Usability in Extreme Temperature Environments of Safeguards Equipment)

  • 백희균;이진원;신중기
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.71-78
    • /
    • 2024
  • For most commercial radiation measurement equipment, manufacturers specify an operating temperature in the range of 0 to +40℃. However, in environments that exceed the quality assurance performance of the safeguards equipment, such as the winter environment in North Korea, the performance of the equipment deteriorates or normal use is impossible. In this study, safeguards equipment measurements were performed by creating an extreme temperature environment using a constant temperature and humidity test chamber. The safeguards equipment used in the evaluation was MIRION's Inspector-2000-based equipment, which evaluated the usability in extreme temperature environments using three types of detection units: NaI(Tl), CZT, and HPGe.