• 제목/요약/키워드: Temperature Difference Ratio

검색결과 786건 처리시간 0.025초

복부 지방율과 하복부 온도와의 관계 (The relations between Waist-to-Hip Ratio(WHR) and the abdominal temperature)

  • 최은미;조정훈;장준복;이경섭
    • 대한한방체열의학회지
    • /
    • 제2권1호
    • /
    • pp.56-62
    • /
    • 2003
  • Objectives : We intented to know the relations between Waist-to-Hip Ratio(WHR) and the abdominal temperature. Methods : Among the patients who visited the oriental gynecological department in Conmaul oriental medical hospital from 2002. 10. 10 to 2002. 11. 9. 130 women were selected for this study. We measured the abdominal temperature by D.I.T.I and Waist-to-Hip Ratio(WHR) by Inbody. Results and Conclusions 1. As WHR was higher, the abdominal temperature became lower. But there was no significant difference between WHR and the abdominal temperature of the abdominal obesity group and the non-abdominal obesity group in the each state. 2. There was significant difference in the abdominal temperature related with the abdominal obesity The abdominal temperature of the non-abdominal obesity group was higer than that of abdominal obesity group. 3. There was significant difference in the WHR according to the age, but no significant difference in the abdominal temperature according to the age. 4. This study showed that the abdominal temperature became lower among the 30-39 year-old women, as WHR was higher.

  • PDF

저온도차 모형 스털링 엔진의 최대출력 설계조건 (DESIGN OF A LOW TEMPERATURE DIFFERENCE STIRLING ENGINE)

  • 정평석;원민영;김수연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.420-423
    • /
    • 2003
  • A low temperature difference model Stirling engine is a small Stirling engine running with several degree of temperature difference without power output. In this study, the design parameters to give maximum power are discussed. As results, the phase angle is about 100 degree, and compression ratio is 1.5% of the ratio of heat source temperatures at maximum power condition.

  • PDF

각종 Nozzle을 통하여 저장조내로 유입되는 BUOYANT JETS의 유동해석 (Flow analysis of Buoyant Jets into Storage Tank through Variable Nozzles)

  • 박이동;조운
    • 태양에너지
    • /
    • 제9권2호
    • /
    • pp.42-50
    • /
    • 1989
  • The Buoyant Jets were analysed experimentally changing flow rate (0.0291/s, 0.0371/s, 0.0451/s), ratio of nozzle tip area to throat area (aspect ratio ${\beta}$=0.4, 1.0, 1.9), and also the temperature difference (${\Delta}T=Ti-T{\infty}$) between the temperature of the inflow water into the storage tank ($1m{\times}1m{\times}3m$) and the mean temperature of the water in the storage tank were changed as $25^{\circ}C,\;35^{\circ}C$ and $45^{\circ}C$. The more aspect ratio decreased, the more the trajectories of Buoyant Jets center-line were decreased and not the more the trajectories of Buoyant Jets centerline were influenced by the increment of the difference of the temperature. The more aspect ratio decreased, the more the half widths and dilution ratio of Buoyant Jets were increased and not the more the half widths and dilution ratio of Buoyant Jets were influenced by the increment of the difference of the temperature. Fr number is the factor that can predict the flow pattern over the whole flow field. And yet for the consideration the near field of Buoyant Jets flow pattern is dominated by magnitude of momentum and buoyancy force.

  • PDF

흡수기내 용액 냉각기가 흡수식 냉동기의 용액 결정화 온도차와 냉각 용량에 미치는 효과 (An Effect on the Solution Crystallization Temperature Difference and Cooling Capacity of the Absorption Chiller by a Solution Cooler in the Absorber)

  • 진성민;이재헌;정종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1518-1523
    • /
    • 2003
  • The objective of the present work is to investigate an effect on the solution crystallization temperature difference and the cooling capacity of the absorption chiller by a solution cooler in the absorber. The cooling capacity of the absorption chiller can be higher, with the enhanced performance of the solution heat exchangers. But, because the solution crystallization temperature difference becomes smaller at the absorber inlet, the heat capacity of the solution heat exchangers might be limited by the danger of crystallization, which can cause the serious damages. In this paper, the heat capacity ratio of the solution cooler is defined as the ratio of the heat capacity of the solution cooler to that of the absorber. If it becomes larger in the additional type solution cooler, the solution crystallization temperature difference is augmented and the cooling capacity is also increased.

  • PDF

Parametric studies on convection during the physical vapor transport of mercurous chloride ($Hg_2Cl_2$)

  • Kim, Geug-Tae;Lee, Kyong-Hwan
    • 한국결정성장학회지
    • /
    • 제14권6호
    • /
    • pp.281-289
    • /
    • 2004
  • The temperature hump is found to be most efficient in suppressing parasitic nucleation. With the temperature humps, there are found to be observed in undersaturations along the transport path for convective-diffusive processes ranging from $D_{AB}$ = 0.0584 $\textrm{cm}^2$/s to 0.584 $\textrm{cm}^2$/s, axial positions from 0 to 7.5 cm. With decreasing Ar = 5 to 3.5, the temperature difference is increased because of the imposed nonlinear temperature profile but the rate is decreased. For 2 $\leq$ Ar $\leq$ 3.5, the rate is increased with the aspect ratio as well as the temperature difference. Such an occurrence of a critical aspect ratio is likely to be due to the effect of sidewall and much small temperature difference. The rate is decreased exponentially with the aspect ratio for 2 $\leq$ Ar $\leq$ 10. Also, the rate is exponentially decreased with partial pressure of component B, P for 1 $\leq$ P $\leq$ 100 Torr.$ B/ $\leq$ 100 Torr.

Effect of aspect ratio on solutally buoyancy-driven convection in mercurous chloride $(Hg_2Cl_2)$ crystal growth processes

  • Kim, Geug-Tae;Lee, Kyoung-Hwan
    • 한국결정성장학회지
    • /
    • 제16권4호
    • /
    • pp.149-156
    • /
    • 2006
  • For an aspect ratio (transport length-to-width) of 5, Pr = 2.89, Le = 0.018, Pe = 2.29, Cv = 1.11, $P_B$=40 Torr, solutally buoyancy-driven convection $(Gr_s=3.03{\times}10^5)$ due to the disparity in the molecular weights of the component A $(Hg_2Cl_2)$ and B (He) is stronger than thermally buoyancy-driven convection $(Cr_t=1.66{\times}10^4)$. The crystal growth rate is decreased exponentially for $2.5\;{\leq}\;Ar\;{\leq}\;5$, with (1) the linear temperature profile and a fixed temperature difference, (2) the imposed thermal profile, a fixed crystal region and varied temperature difference. This is related to the finding that the effects of side walls tend to stabilize convection in the growth reactor. But, with the imposed thermal profile, a fixed source region and varied temperature difference, the rate is increased far $2\;{\leq}\;Ar\;{\leq}\;3$, and remains nearly unchanged for $3\;{\leq}\;Ar\;{\leq}\;5$.

열환경 완화를 통한 주택지내 쾌적성 확보에 관한 연구 (A Study on Thermal Comfortable Following the Thermal Environment Migration in Detached Housing Area)

  • 류지원;정응호;호야노 아키라;김대욱
    • 한국주거학회논문집
    • /
    • 제24권1호
    • /
    • pp.51-59
    • /
    • 2013
  • This study aims to improve the thermal comfort level of detached housing area by reducing the impact of thermal environment. The study focused on reducing surface temperature that is generated in buildings and adjacent spaces as a result of sensible heat load and presented a proposal on implementing planting method considering its outdoor condition and structure and composed materials. To perform the study, we utilized 3D-CAD to examine the outdoor condition and structure and composed materials that impact on surface temperature and conducted space design after reflecting climatic elements in simulations. The result is as follows. In reviewing temperature distribution of Heat Island Potential (HIP) of buildings and adjacent spaces, in case where green coverage ratio is increased, there was a $6^{\circ}C$ temperature difference and in regard to changes in the thermal environment in detached housing area, in case where rooftop planting, surface improvement, planting, and overall green coverage ratio is increased, there was a $10^{\circ}C$ temperature difference. In addition, there was difference in temperature in detached housing area following the changes in wind.

NATURAL CONVECTION AROUND A HEAT CONDUCTING AND GENERATING SOLID BODY INSIDE A SQUARE ENCLOSURE WITH DIFFERENT THERMAL BOUNDARIES

  • NITHYADEVI, NAGARAJAN;UMADEVI, PERIYASAMY
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제19권4호
    • /
    • pp.459-479
    • /
    • 2015
  • Two-dimensional steady laminar natural convection around a heat conducting and generating solid body inside a square enclosure with different thermal boundaries is performed. The mathematical model is governed by the coupled equation of mass, momentum and energy. These equations are discretized by finite volume method with power-law scheme and solved numerically by SIMPLE algorithm with under-relaxation technique. Effect of Rayleigh number, temperature difference ratio of solid-fluid, aspect ratio of solid-enclosure and the thermal conductivity ratio of solid-fluid are investigated numerically for Pr = 0.7. The flow and heat transfer aspects are demonstrated in the form of streamlines and isotherms respectively.

PbO-B$_2$O$_3$-TiO$_2$-BaO계의 유리화에 대한 전이온도 및 성분 원소비의 영향 (Effects of Transition Temperature and Atomic Ratio on Glass Formation Tendency in the PbO-B$_2$O$_3$-TiO$_2$-BaO System)

  • 이선우;심광보;오근호
    • 한국세라믹학회지
    • /
    • 제35권12호
    • /
    • pp.1274-1279
    • /
    • 1998
  • The glass forming ability of the PbO-B2O3-TiO3-BaO system was investigated in relation to transitieon tem-peratures and the atomic ratio between constituents. Glass forming tendency was improved as the tem-peratures and the atomic ratio between constituents. Glass forming tendency was improved as the tem-perature differences between liquidus temperature and crystallization(or glass transition) temperature de-creased and the temperature difference between crystallization and glass transition temperature increases. The atomic ratio could be used as a criterion to deign glass systems. The interposition of B and Ba atoms between Pb and Ti atoms was one of important factors in glass formation.

  • PDF

용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰 (Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.