• 제목/요약/키워드: Temperature Difference Measurement

검색결과 446건 처리시간 0.025초

데오도라이트 시스템의 측정 불확도 연구 (A Study on Measurement Uncertainty of Theodolite System)

  • 이건탁;이동주;박흥철;오재명
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.229-233
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is 0.5 mm or better for distance 0 ~ 100m. And the system is used for a product of middle and large scale. This study is performed for the measurement uncertainty of the system. We could know that the main uncertainty factors are temperature, illumination and skill. And, we perform the study for the effect according to the height difference of scale bar. And, we calculated the measurement uncertainty with those factors.

  • PDF

고정밀 공작기계의 열적효과 측정 및 불확도 추정에 관한 연구 (A Study on the Thermal Effects Measurement and Uncertainty Estimation for High Precision Machine Tools)

  • 손덕수;김상화;박일환
    • 한국기계가공학회지
    • /
    • 제12권2호
    • /
    • pp.107-113
    • /
    • 2013
  • When the main spindle of high precision machine tools are run many hours, heat is generated in bearing parts of the inside of the spindle. Also, headstock is appeared distortion by inside and outside temperature difference of a machine. This paper studies method to measure behavior of machine tool about these thermal effects. In addition, it estimates measurement uncertainty factors which can be appeared in thermal effects measurement. Finding the factor of thermal affect measurement is important for estimation of measurement uncertainty. This paper measures thermal effects of high precision machine tools and evaluates the important factors of uncertainty.

UV Laser Rayleigh Scattering을 이용한 $C_3H_8/O_2$ 화염에서 가스 성분의 농도 및 온도 분포 계측에 관한 실험적 연구 (Am Experimental Study on Measurement of Number Density and Temperature Distributions in $C_3H_8/O_2$ Flame by UV Laser Rayleigh Scattering)

  • 진성호;남기중;김회산;장래각;박승한;김웅;박경석;김경수
    • 한국자동차공학회논문집
    • /
    • 제5권2호
    • /
    • pp.60-68
    • /
    • 1997
  • Rayleigh Scattering Cross Sections($\sigma$i) of various gases and the temperature distributions of premixes C3H8/O2 flame are measured by high power KrF(248nm) Exci- mer laser and ICCD camera. Results show that $\sigma$i of O2 and Propane(C3H8) gases agree well in the 5% error range, but of H2 has the more or less difference from the calcul- ated value by other groups. This is attributed to the low RS signal of H2 to Nosie level(S/N ratio). The temperature distributions of flame range out between 300K in the air and about 2000K in the burned area. In this temperature range, out system has the about 250K temperature resolution. Because low RS signals in the reaction area with high temperature are affected highly by noises, temperature uncertainty of this area is relatively high to another part of flame. Experimental results show that UV Rayleigh Scattering can be used for the measurement of mixing ratio of mixed gases and the temperature distributions of flame. Especially, this technique can be applied for the measurement of the mixing ratio of air/fuel before the ignition and the flame structure after the ignition inside the Engine.

  • PDF

표준백금저항온도계를 이용한 온도측정능력 상호비교 (Inter-comparison of temperature measurement capability using standard platinum resistance thermometers)

  • 감기술;강주식;이용재;이광복;김용규;박승남
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.86-94
    • /
    • 2009
  • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.

Measurement of Thermo-Optic Coefficient of a Liquid Using a Cascade of Two Different Fiber Bragg Gratings

  • Kim, Kwang Taek;Kim, In Soo
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.95-99
    • /
    • 2013
  • We proposed and demonstrated a fiber optic sensor for detecting the thermo-optic coefficient of a liquid, based on a cascade of two different FBGs. One of the two FBGs was etched, and its cladding was removed, for evanescent wave coupling with an external liquid. The Bragg wavelength of the non-etched FBG was used as a reference for the temperature of the surrounding liquid. The refractive index (RI) and thermo-optic (T-O) coefficient of a liquid can be detected from the difference between the Bragg wavelengths of the two FBGs, and the variation of the difference in accordance with temperature.

CFD를 이용한 대형매장 냉열원 주변의 공기유동에 관한 연구 (A Study on the Airflow near the Cold Heat Source Using CFD in Merchandising Store)

  • 조성우;박민용;임영빈
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.629-634
    • /
    • 2005
  • This paper performed to predict vertical temperature distribution and air flow near cold heat source in the mass merchandising store. At the height of 150 cm, the vertical air temperature difference between the results of CFD and of measurement field showed $10\%$ near the refrigeration zone and $8.8\%$ near the freezing zone. Therefore, it regarded as appropriate for the using CFD to investigate airflow near the heat sources. The 3 kinds of CFD model were divided by the disposition of diffuser/exhaust and diffuser air temperature. At the refrigeration and freezing zone in the Model 2 and 3, the temperature difference between the front and the back of human model were showed $6.8^{\circ}C\;and\;3.9^{\circ}C$ with diffuser air temperature $17^{\circ}C$ and were showed $6.8^{\circ}C$ and $4^{\circ}C$ with diffuser air temperature $19^{\circ}C$.

온도측정에 의한 SPD용 배리스터의 성능평가에 관한 연구(I) (A Study on Performance Evaluation of SPD Varistor by Temperature Measurement(I))

  • 여인식;고영민;이기식
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.490-494
    • /
    • 2009
  • In this paper, how the temperature of a varistor changes when $10/350{\mu}s$ surge currents and/or DC leakage currents are applied on it, respectively, are investigated. The temperature change in varistor is related with injection energy and leakage current. which is the integration of power in time. By the surge current test, we found that the temperature jump is proportional to the level of surge current with slant 52.535 and has no relation with the ambient temperature. And by the DC leakage current test, the difference in temperatures between varistor and ambient is proportional to the magnitude of leakage current. The slope of measured line(the temperature difference vs. the leakage current) shows alteration around $100{\mu}A$. The varistors can not be used more than $100{\mu}A$ region any more. From the above experimental results, we can conclude that data of the surge current test and also those of DC leakage current test can predict the performance of varistors of which the surge protective devices are made.

인터페로미터 방향 탐지기의 디지털 위상차 측정 기법 성능 분석 (Performance Analysis on Digital Phase Difference Measurement Techniques for Interferometer Direction Finder)

  • 강종진;박성균;노지현
    • 한국정보통신학회논문지
    • /
    • 제22권8호
    • /
    • pp.1076-1082
    • /
    • 2018
  • 본 논문은 서로 다른 안테나로부터 수신되는 무선 신호의 위상차를 계산하여 신호의 도래방향을 측정하는 인터페로미터 방향 탐지 장치에 관한 것이다. 최신의 전자전용 방향 탐지기는 위상차 측정에 있어서 온도에 따른 위상측정 편차가 작고, 낮은 신호 대 잡음비 환경 에서도 비교적 위상측정 성능이 우수한 디지털 위상차 측정 방법이 적용되고 있다. 시스템에서 요구되는 방향 탐지 정확도 성능 달성을 위한 위상차 측정 허용 오차를 도출하고, 디지털 위상차 측정 방법에 대하여 소개하였다. 샘플 개수, 신호 대 잡음비, 간섭신호 유입에 따른 성능을 정량적으로 분석하였고, 시뮬레이션을 통하여 주파수 영역 측정방법이 시간영역 대비 낮은 SNR 및 간섭신호 유입 환경에서 더 좋은 성능을 보임을 확인하였다. 제안한 방법은 인터페로미터 방향 탐지 장치의 성능 결정에 활용 할 수 있을 것이다.

공기유동에 대한 고온상태의 비원형 도과내에서의 열전달 및 압력강하의 측정 (Measurement of Heat Transfer and Friction Coefficients for Flow of Air in Noncircular Ducts At High Surface Temperatures.)

  • 이동렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.552-562
    • /
    • 2001
  • Measurement of average of heat transfer and friction coefficients were obtained with air flowing through electrically heated ducts having square, rectangular(aspect ration, 5), and triangular cross section for range of surface temperature from $540^{\circ}$to $1780^{\circ}$ R and Reynolds number from 1000 to 330,000. The results indicates that the effect of heat flux on correlations of the average heat transfer and friction coefficients is similar to that obtained for circular tubes in previous investigation and was nearly eliminated by evaluating the physical properties and density of the air a film temperature halfway between the average surface and fluid bulk temperatures, With the Nusselt and Reynolds numbers on the hydraulic diameter of the ducts, the data for the noncircular ducts could be represented by the same equations obtained in the previous investigation for circular tubes. Correlation of the average difference between the surface corner and midwall temperatures for the square duct was in agreement with predicted values from a previous analysis. However, for the rectangular and triangular ducts, the measured corner temperature was greater by approximately 20 and 35 percent, respectively, than the values predicted by analysis.

  • PDF

웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발 (Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging)

  • 안미숙;한용희
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.