• 제목/요약/키워드: Temperature Difference Energy

검색결과 1,101건 처리시간 0.028초

옥상녹화가 PV모듈 발전량에 미치는 영향 고찰 (A study on the effect that the green roof has on the performance of PV module)

  • 유동철;이응직
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.113-119
    • /
    • 2012
  • This study aims to examine the effect of the combined application of green roof and PV system on the PV efficiency by measuring the temperature and performance of PV module in order to reduce the temperature on the roof using roof planting system and determine the potential of efficient increase in solar-light power generation. In the experimental methodology, either monocrystalline or polycrystalline PV module was installed in green roof or non-green roof, and then the surface temperature of PV was measured by TR-71U thermometer and again the performance, module body temperature, and conversion efficiency were measured by MP-160, TC selector MI-540, and PV selector MI-520, respectively. As a result, the average body temperature of monocrystalline module was lower by $6.5^{\circ}C$ in green roof than in non-green roof; that of polycrystalline module was lower by $8.8^{\circ}C$ in green roof than in non-green roof. In the difference of generation, the electricity generation of monocrystalline module in green roof was 46.13W, but that of polycrystalline module was 68.82 W, which indicated that the latter produced 22.69W more than the former.

차세대에너지시스템 구축을 위한 도시기상조건 시계열분석 (A Time Series Analysis on Urban Weather Conditions for Constructing Urban Integrated Energy System)

  • 김상옥;한경민;이정재;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.26-31
    • /
    • 2009
  • This study was analysed influence of urban higher temperature in Busan about time series analysis of AWS data. The results are as follows. (1) The temperature of Busan show min $13.2^{\circ}C$ ~max $15.8^{\circ}C$ by 50 years, it is on the rise. (2) The seasonal adjustment series, summer appeared min $17.5^{\circ}C$ ~max $28.9^{\circ}C$ with primitive series similarly. The winter was min $-11.4^{\circ}C$ ~max $17.9^{\circ}C$, the minimum temperature was more lowly than primitive series and maximum temperature was more higher than primitive series. The results, seasonal adjustment series is guessed with influence difference urban structural element beside seasonal factor. (3) Regional analytical result, January appeared with range of min 28% ~max 196% of the seasonal factor and August appeared min 90% ~ max 106%. One of the case which is of 100% or more of the seasonal factor January 12nd~17th, August appears at the 15~17th.

  • PDF

SOFC용 고온 적층 단열재의 해석적 고찰 (An Analysis Using Numerical Model of Composite Multi-Layer Insulation for SOFC)

  • 최종균;황승식;최규홍
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.540-548
    • /
    • 2019
  • This study was conducted to develop insulation for solid oxide fuel cell (SOFC). The developed insulation is based on the lamination technology and the radiation shielding technology of the satellite insulation. The insulation material is consisting of insulation material for conduction resistance, spacer, and radiation shielding material. The experimental apparatus consisting vacuum bell jar, pump, heater and temperature recording device has developed to verify the performance of the insulation. The experimental values were used as reference data for the modeling development. In this paper, heat transfer is assumed to be one- dimensional phenomena for the prediction of insulation performance and internal temperature distribution in high temperature region of SOFC. The developed model was used to compare the performance difference of insulation types according to composition materials. The analysis result shows that the insulation including spacer and radiation shielding has better heat insulation performance than other cases. In this study, the thickness reduction effect of about 20% was shown compared to the insulation including only conductive material. It is noted that the radiant shielding material should be carefully selected for durability, because SOFC insulation should be used for a long time at high temperature.

도시 수목식재와 미기후 개선의 상관성 구명 (Exploring Relationships between Urban Tree Plantings and Microclimate Amelioration)

  • 조현길;안태원
    • 한국조경학회지
    • /
    • 제34권5호
    • /
    • pp.70-75
    • /
    • 2006
  • The purpose of this study is to explore the effects of difference in urban tree plantings on microclimate amelioration, and to suggest essential information for quantifying urban energy budgets and energy savings. This study was focused on measuring and analyzing air temperature and relative humidity in summer. Daytime air temperatures at places with 8%, 24%, 44%, 79%, and 100% cover of woody plants were, respectively, $0.6^{\circ}C,\;1.3^{\circ}C,\;2.4^{\circ}C,\;3.5^{\circ}C,\;and\;4.8^{\circ}C$ cooler, compared to a place with 0% cover. A 10% increase of woody plant cover was estimated to reduce the temperature by approximately $0.55^{\circ}C$. The temperature reduction effects were relatively greater between places with lower cover of woody plants than between those with higher cover. Woody plant cover and crown volume were the appropriate indicators which quantified the effects of tree plantings on air temperatures, based on the correlation analysis. Regression equations to estimate temperature change ($Y:^{\circ}C$) using woody plant cover ($X_1:%$) or crown volume ($X_2:m^3$) as independent variables are as follows: $$1nY=3.3233-0.0018X_1\;(r^2=0.99,\;p<0.0001)\;Y=27.5297-0.0019X_2\;(r^2=0.96,\;p=0.0007)$$

한강수계 광역상수도 원수관의 지열 영향 조사 (Geothermal Effects on the Underground Water Conveyance Pipe System from Han River)

  • 조용;박진훈;박태진;김영준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.171.2-171.2
    • /
    • 2010
  • Geothermal effects on the underground water conveyance pipe system have been investigated through the multiregional water supply system from Paldang water intake station. To make an investigation of raw water thermal energy, temperature sensors are installed the surface of the pipes of metropolitan area water supply system. In 2009 winter and early spring seasons, the monthly averaged temperatures at Paldang 2 intake stations are $1.94^{\circ}C$ in February, $4.96^{\circ}C$ in March, and $10.56^{\circ}C$ in April. After the transfer in 26.0 km distance of tunnel and buried pipe, the raw water temperatures are raised to $3.13^{\circ}C$, $6.04^{\circ}C$, and $11.39^{\circ}C$ respectively. As the temperature difference between the raw water and the air reduces, the temperature increasement is reduced by $1.19^{\circ}C$ in Feb., $1.08^{\circ}C$ in Mar., and $0.83^{\circ}C$ in Apr. Since the flowrate is over 1,150,000 $m^3$/day, it is estimated that the water exchanges a huge amount of heat over 1.0 Tcal a day with the ground.

  • PDF

고온고압수중에서 접촉형상에 따른 마멸거동 분석 (Analysis of Wear Behaviour Corresponding to Contact Shape in High Temperature and High Pressure Environment)

  • 송주선;김형규;이영호;김재훈
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.31-36
    • /
    • 2004
  • In this paper, fretting wear tests were conducted in air at room temperature (RT) and in water at high temperature and high pressure (HTHP) environment to analyze the wear characteristic. As for the supporting condition between the tube and spring/dimple, the gap of 0.2 mm in air at RT and the normal force of 10 N and the slip of $50\;{\mu}\;m$ in water at HTHP were applied. Four different shapes of spring/dimple specimen (type A, B, C, D) were used. Detail eaxamination of wear scar was also performed using SEM micrographs. As a result, in the case of the spring of truncated wedge, severer wear occurs than the others. Protrusion part was found and larger in air at RT. It is thought that the difference in the wear volume and the protrusion is caused by the different wear mechanism corresponding to the different environment.

  • PDF

물-에너지 넥서스기반 국내 댐 가능최대 수열에너지 산정 (Estimation of the Probable Maximum Water Thermal Energy in Korean Dams based on the Water-Energy Nexus Concept)

  • 정영훈
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.45-53
    • /
    • 2018
  • Demand for essential resources including water, energy and food is rapidly increasing due to climate change, population growth and urbanization. To solve this problem, the concept of water-energy-food nexus has been introduced, and many countries have been trying to acquire the Nexus technology that can maximize the efficiency by analyzing the interconnection between resources. In this regard, this study attempted to estimate the probable maximum water thermal energy in the dam based on the water-energy nexus concept. The estimation of the probable maximum water thermal energy was implemented to monthly water storage of the largest dams in the four major river systems. As a result of analyzing the estimated monthly water thermal energy from 2000 to 2016, Soyang River dam has the largest probable maximum water thermal energy, and Sumjin River dam has the smallest. However, the probable maximum water thermal energy was small in common between March and April, between September and October due to the small temperature difference between the ambient air and the dam water. Also, according to the characteristics of the dam, Daecheong dam and Soyang River dam were beneficial for supplying water thermal energy for heating, and Sumjin River dam and Andong dam were advantageous for supplying water thermal energy for cooling. Our findings can be useful to realize the water-energy-food nexus by increasing the utilization and value of water resources as well as expanding the roles and functions of dams as a starting point to use dam water thermal energy.

X-ray tube 내 열유동 해석에 관한 연구 (A study on the analysis of heat flow in X-ray tube)

  • 윤동민;서병석;전용한
    • Design & Manufacturing
    • /
    • 제15권1호
    • /
    • pp.26-31
    • /
    • 2021
  • As the aging ages, the disease also increases, and the development of AI technology and X-ray equipment used to treat patients' diseases is also progressing a lot. X-ray tube converts only 1% of electron energy into X-ray and 99% into thermal energy. Therefore, when the cooling time of the anode and the X-ray tube are frequently used in large hospitals, the amount of X-ray emission increases due to temperature rise, the image quality deteriorates due to the difference in X-ray dose, and the lifespan of the overheated X-ray tube may be shortened. Therefore, in this study, temperature rise and cooling time of 60kW, 75kW, and 90kW of X-ray tube anode input power were studied. In the X-ray Tube One shot 0.1s, the section where the temperature rises fastest is 0.03s from 0s, and it is judged that the temperature has risen by more than 50%. The section in which the temperature drop changes most rapidly at 20 seconds of cooling time for the X-ray tube is 0.1 seconds to 0.2 seconds, and it is judged that a high temperature drop of about 65% or more has occurred. After 20 seconds of cooling time from 0 seconds to 0.1 seconds of the X-ray tube, the temperature is expected to rise by more than 3.7% from the beginning. In particular, since 90kW can be damaged by thermal shock at high temperatures, it is necessary to increase the surface area of the anode or to require an efficient cooling system.

드라이쿨러를 적용한 외기냉수냉방 시스템 설계에 관한 연구 (A study on design for free cooling system using dry cooler)

  • 윤정인;백승문;허정호;김영민;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1027-1031
    • /
    • 2014
  • 외기냉수냉방 시스템은 공조나 산업공정에 사용되는 냉수를 저온의 외기를 이용하여 냉각하는 시스템으로 에너지를 절감하기위해 사용되며, 냉각시스템과 외기와 냉수가 열교환을 하는 드라이쿨러로 구성되어있다. 외기냉수냉방 시스템은 지속적인 냉방이 필요한 곳에 에너지절감효과가 뛰어나나 국내의 경우, 외기냉수냉방 시스템에 설계 기준과 자료가 미비하다. 따라서 본 연구에서는 상용프로그램 HYSYS를 이용하여, 드라이쿨러를 이용한 외기냉수냉방 시스템의 요소변화에 따른 성능을 비교 분석했으며 그 결과는 다음과 같다. 드라이쿨러의 냉각능력은 외기온도, 요구냉수온도, 열교환기의 LMTD (Logarithmic Mean Temperature Difference, 대수평균온도차)에 따라 변한다. 드라이쿨러는 외기온도가 낮을 수록 그 냉각능력이 증가하며, LMTD가 낮은 드라이쿨러가 LMTD가 높은 것에 비하여 고온의 외기온도에서 사용이 가능하였다. 외기온도가 극히 낮은 지역에서는 글리콜이 함유된 부동액을 사용해야하며 국내의 외기온도를 고려하였을 때, 글리콜농도 34%의 부동액이 적절한 것으로 판단된다. 냉동기에 적용될 작동유체의 경우, R22, R134a, R407C의 압축일을 비교했으며, R134a가 환경관련 규제와 에너지 사용측면에서 우수한 냉매로 사료된다.

농어촌지역 미활용에너지의 부존량과 이용 가능량 분석 (A Study on Analysis of Reserves and Available Capacity of Unutilized Energy in Rural Community)

  • 박미란;류연수;김진욱;이용욱;배성돈;채갑병
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.19-25
    • /
    • 2014
  • Alternative sources of energy take a higher interest in order to reduce the greenhouse gas under the Climate Change Convention, fossil fuel consumption, and lower social anxiety about nuclear power such as crisis involving the Fukushima plant, problem of obsolete equipment. The energy consumption of agriculture, forestry and fisheries in South Korea is 3,082,000toe by 2011, reliance on electrical energy(35%) and oil(57.2%) is very high with 92.2%. In this study, we examined reserves and available capacity of temperature difference energy for thermal discharge from plant, treated sewage, river water, dam, and agricultural reservoir in rural community. Reserves of unutilized energy are 455,735Tcal/yr in rural community, these accounts for 78% of total reserves 582,385Tcal/y. Thermal discharge from plant has the most reserves of unutilized energy in rural community, it is estimated that it has the reserves of 277,410Tcal/y. Available capacity of unutilized energy in rural community is total 134,147Tcal/y, thermal discharge from plant available for heating is the most 128,035Tcal/y, and it shows in the order of treated sewage 4,318Tcal/y, river water 1,653Tcal/y, and reservoir 141Tcal/y. Elevating temperature area of green house by 2012 is 21,208ha. The amount of energy required for heating the greenhouse a year is dbout 11,365Tcal/y with 8.5% of the total available capacity of unutilized energy.