• 제목/요약/키워드: Temperature Check

검색결과 578건 처리시간 0.021초

Cryogenic Thermal Cycling Test on IGRINS cross-disperser VPH Grating

  • 정현주;임주희;이성호;;박수종;육인수
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.156-156
    • /
    • 2011
  • VPH (Volume Phase Hologram) grating is one of the transmission gratings and is known as its remarkable efficiency (>90%). It has two different densities of gelatins causing interference patterns. The VPH grating is favored in many astronomical instruments these days and also IGRINS, which is up coming near infrared high-resolution spectroscope expected to see the first light next year, uses the VPH grating as its cross-disperser. The infrared astronomical instruments operate at cryogenic temperature (~100K) in order to cut down thermal noise and the optical components of IGIRNS will be operated at 130K. The VPH grating is sandwiched in between fused silica or glass and glued together using optical adhesive. IGRINS is expected to go through 50 times of thermal cycling in 10 years including the performance test and this research is to check whether the physical characteristic such as the adhesion or dichromatic gelatin does not break and change from the several cryogenic thermal cycling. The two identical test gratings provided from Kaiser Optical System, Inc. are used in this test. One VPH grating is cooled down to 100K for 2 hours with maximum dT/dt = 5 and warmed up to the room temperature and another grating is kept stored in the room temperature and used as a control sample. In order to check the change, we inspected the grating with eyes and checked its efficiency and transmission at the room temperature every 10 cycling. From the 40 times of cryogenic temperature cool down cycling, the VPH grating showed no signs of change within the error compared to the control sample. We concluded the VPH grating is durable through several cryogenic thermal cycling.

  • PDF

온도센서를 이용한 농.식품 유통관리를 위한 Smart RFID Tag 개발 (An implementation of Smart RFID Tag using temperature sensor for agri-food distribution management)

  • 이창원;이승준;정경권;이현관;엄기환
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.231-234
    • /
    • 2011
  • 최근 세계적으로 RFID tag에 외부환경 정보를 습득 할 수 있는 Smart RFID tag 기술에 대한 관심도가 증가하고 있다. 본 논문에서는 온도센서를 이용한 Smart RFID tag를 제안한다. Smart RFID tag는 13.56Mhz의 안테나, 온도센서, 데이터를 처리하는 컨트롤러로 구성되어져 있으며, 안테나 설계 및 PCB 제작으로 소형화함으로서 농 식품 포장에 적용될 수 있도록 제작하였다. Smart RFID tag는 농 수산식품 포장지에 부착 되어 유통되며 소비자에게 판매되는 과정에서 생긴 온도변화를 체크하게 된다. 실시간으로 온도변화를 체크하기 때문에 식품의 신선도 및 운반상태를 확인할 수 있다. 응용사례로써 Smart RFID tag를 활용한 smart 냉장고 시스템을 제안하였다.

  • PDF

영상장치 센서 데이터 QC에 관한 연구 (A study on imaging device sensor data QC)

  • 윤동민;이재영;박성식;전용한
    • Design & Manufacturing
    • /
    • 제16권4호
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

물리적 처리에 따른 낙엽송 방부원주목의 표면할렬 방지효과 (Surface Checking Reduction Effect of Preservative-treated Korean Larch Round-woods with Various Physical Treatments)

  • 방성준;오정권;이상준;박준호;장성일;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권1호
    • /
    • pp.107-115
    • /
    • 2017
  • 본 연구에서는 국산 낙엽송 방부원주목을 대상으로 물리적 처리(인사이징, 배할, 열기건조)에 따른 표면할렬 방지효과와 장기 사용연한 확보 가능성을 실험적으로 검토하였다. 표면할렬이 목재 내 외부의 급격한 수분경사로 인해 발생하기 때문에 본 연구에서는 국내 최저 평형함수율 조건[온도($2^{\circ}C$), 습도(44.6%)]에서 시험편이 평형함수율(8.6%)에 도달할 때까지 실험을 진행하였다. 물리적 처리에 따른 표면할렬 방지효과를 검토한 결과, 무처리 시험편(Type C)의 경우, 모든 시험편에서 약제 침투 깊이보다 깊은 할렬이 발생하여 장기 내부후성을 확보할 수 없는 것으로 나타났다. 한편, 약제침투도 개선을 위해 사용하는 인사이징 처리만으로도 시험편의 80%에서 약제침투깊이보다 깊은 표면할렬을 방지하는 효과가 있었다. 그러나 국내에서 할렬을 방지하고자 사용하는 배할 처리는 인사이징 처리에 비하여 약제 침투깊이보다 깊은 표면할렬을 야기하였다.

가속수명시험을 이용한 쇼트피닝가공 알루미늄 합금의 신뢰성 평가에 관한 연구 (A Study on the Reliability Evaluation of Shot Peened Aluminium Alloy Using Accelerated Life Test)

  • 남지헌;강민우;정성균
    • 대한기계학회논문집A
    • /
    • 제30권12호
    • /
    • pp.1534-1542
    • /
    • 2006
  • In this paper, the concept of accelerated life test, which is a popular research field nowadays, is applied to the shot peened material. To predict the efficient and exact room temperature fatigue characteristics from the high temperature fatigue data, the adequate accelerated model is investigated. Ono type rotary bending fatigue tester and high temperature chamber were used for the experiment. Room temperature fatigue lives were predicted by applying accelerated models and doing reliability evaluation. Room temperature fatigue tests were accomplished to check the effectiveness of predicted data and the adequate accelerated life test models were presented by considering errors. Experimental result using Arrhenius model, fatigue limit obtain almost 5.45% of error, inverse power law has about 1.36% of error, so we found that inverse power law is applied well to temperature-life relative of shot peened material.

Combustion Characteristics of Heavy Fuel Oil-water Emulsion

  • Kim Houng-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.88-92
    • /
    • 2006
  • This study is intended to check the flame temperature to raise in burning grade C heavy fuel oil and emulsion fuel oil in a boiler and to measure the concentration of Dry Shoot(DS) and Soluble Organic Fraction(SOF) after collecting the Particulate Matters (PM). The flames temperature in boiler was measured by burning grade C heavy oil and oil-water emulsion (C heavy oil $70\%\;and\;30\%$ of water) Combustion characteristics of two fuels was also compared by trapping particulate matters (PM) in exhaust gas and measuring the generated quantities of DS and SOF in fuel gas.

FA-50 경공격기 전기체 지상 고/저온시험 (Ground High/Low Temperature Test for FA-50 Aircraft)

  • 안종훈;김태호;우승철;조영균;김도완
    • 시스템엔지니어링학술지
    • /
    • 제6권1호
    • /
    • pp.41-46
    • /
    • 2010
  • The ground high/low temperature test objective is to check the normal ground operation of FA-50 aircraft in the extreme ground ambient conditions. The aircraft was exposed in climatic conditions of the basic climatic category according to the MIL-HDBK-310. For verified normal operation in the extreme high temperature, the high temperature test was performed in the hot regional type conditions and accentuated solar radiation heat. This test was performed at the test chamber in ADD where is in Haemi. This paper was described about the test procedure of FA-50 high/low temperature including preparation, testing and results.

  • PDF

A Study on the Distribution and Time Dependent Change of Wood Temperature by Solar Radiation

  • Xu, Hui Lan;Kang, Wook;Chung, Woo Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권2호
    • /
    • pp.141-147
    • /
    • 2009
  • The fluctuation of physical properties in wood or wood composites is an important subject when the materials in building and construction. Sorption and desorption occur in wood when exposed to the open air, and the temperature distribution in wood can fluctuate as a result of changes in environmental temperature, solar radiation, humidity, and wind velocity. In this study, the temperature difference and fluctuation caused by outdoor environment among different wood species were analyzed using a numerical method. The effect on the process of heat transfer in wood caused by environmental factors was investigated using 1-dimensional partial differential equation with real boundary and initial conditions. The experimental data have been used to check the accuracy of programming code. Through analysis, it was found out that density and moisture content have a negative effect on thermal diffusivity of wood.

Corrosion Behavior of Nickel-Plated Alloy 600 in High Temperature Water

  • Kim, Ji Hyun;Hwang, Il Soon
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.61-67
    • /
    • 2008
  • In this paper, electrochemical and microstructural characteristics of nickel-plated Alloy 600 were investigated in order to identify the performance of electroless Ni-plating on Alloy 600 in high-temperature aqueous condition with the comparison of electrolytic nickel-plating. For high temperature corrosion test of nickel-plated Alloy 600, specimens were exposed for 770 hours to typical PWR primary water condition. During the test, open circuit potentials (OCP's) of all specimens were measured using a reference electrode. Also, resistance to flow accelerated corrosion (FAC) test was examined in order to check the durability of plated layers in high-velocity flow environment at high temperature. After exposures to high flow rate aqueous condition, the integrity of surfaces was confirmed by using both scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). For the field application, a remote process for electroless nickel-plating was demonstrated using a plate specimen with narrow gap on a laboratory scale. Finally, a practical seal design was suggested for more convenient application.

초전도 케이블용 Aluminum Cryostat 제조기술 개발 (The Development of Manufacturing Technology of Aluminum Cryostat for Superconducting Cable)

  • 김수연;이창호;김도운;장현만;김동욱
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.243-245
    • /
    • 2003
  • The method to fabricate the cryostat of superconducting cable is extrusion type which is used Aluminum ingot under high temperature such as 45$0^{\circ}C$ and the cryostat is formed above cable core and MLI layer. In this case, it is expected to occur thermal injury in cable core and MLI layer, so it is necessary to study to prevent thermal injury. So in this paper, using simulation on radiation and convection which are accompany with fabricating cryostat, it is suggested to reduce the thermal injury. By measuring simulation temperature and real temperature, it is possible to check the temperature on cable core and MLI layer and using these temperature, it is possible to predict whether thermal injury is occurred or not on cable core and MLI layer.

  • PDF