• Title/Summary/Keyword: Temperature

Search Result 88,259, Processing Time 0.101 seconds

An Electric Load Forecasting Scheme with High Time Resolution Based on Artificial Neural Network (인공 신경망 기반의 고시간 해상도를 갖는 전력수요 예측기법)

  • Park, Jinwoong;Moon, Jihoon;Hwang, Eenjun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.11
    • /
    • pp.527-536
    • /
    • 2017
  • With the recent development of smart grid industry, the necessity for efficient EMS(Energy Management System) has been increased. In particular, in order to reduce electric load and energy cost, sophisticated electric load forecasting and efficient smart grid operation strategy are required. In this paper, for more accurate electric load forecasting, we extend the data collected at demand time into high time resolution and construct an artificial neural network-based forecasting model appropriate for the high time resolution data. Furthermore, to improve the accuracy of electric load forecasting, time series data of sequence form are transformed into continuous data of two-dimensional space to solve that problem that machine learning methods cannot reflect the periodicity of time series data. In addition, to consider external factors such as temperature and humidity in accordance with the time resolution, we estimate their value at the time resolution using linear interpolation method. Finally, we apply the PCA(Principal Component Analysis) algorithm to the feature vector composed of external factors to remove data which have little correlation with the power data. Finally, we perform the evaluation of our model through 5-fold cross-validation. The results show that forecasting based on higher time resolution improve the accuracy and the best error rate of 3.71% was achieved at the 3-min resolution.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

A Study on the Oxidation Behaviors of Power Plant Valve Materials under the Ultra Super Critical Condition (초초 임계 화력 발전소용 밸브 소재의 산화 거동)

  • Lee, J.S.;Cho, T.Y.;Yoon, J.H.;Joo, Y.G.;Song, K.O.;Cho, J.Y.;Kang, J.H.;Lee, S.H.;Uhm, K.W.;Lee, J.W.
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.1
    • /
    • pp.26-33
    • /
    • 2009
  • Recently ultra-supercritical steam power plants operate at $1000^{\circ}F$ ($538^{\circ}C$) and 3500 psi (24.1 MPa). Thermal efficiency of power plant will be increased about 2% if steam temperature increases from $1000^{\circ}F$ to $1150^{\circ}F$ ($621^{\circ}C$). In this study valve materials Incoloy901 (IC901) and Inconel718 (IN718) were nitrided to improve the surface hardness and solid lubrication function of the valve materials. The hardness of both IC901 and IN718 increased about two times by ion nitriding. IC901, IN718 and their nitrided specimens were corroded under ultra super-critical condition (USC) of $621^{\circ}C$. and 3600 psi (24.8 MPa) for 2000 hours. Oxidations of both IC901 and IN718 were very small due to the formation of protective oxide layer on the surface. But the corrosion resistance of both nitrided specimens decreased because of the formation of non-protective nitride layer of $Fe_{4}N$, $Fe_{2}N$ and CrN on the surface layer. The hardness of both nitrided IC901 and IN718 at $20{\mu}m$ depth from the surface decreased about 30% and 20% respectively by USC 2000 hours.

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

Long-term Tilt Prediction Model for the L-type Retaining Wall Adjacent to Urban Apartments (도심지 아파트 L형 옹벽의 장기 경사거동 예측모델)

  • Koo, Ki Young;Seong, Joo Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.134-142
    • /
    • 2012
  • This paper presents a study of system identification on the tilt response of the L-type retaining wall located at Tanhyun 11th ACE Apartment, Ilsan in order to understand mechanism how the structure behaves in operational conditions and to provide a reference tilt values for assessing structural abnormality. The retaining wall was extraordinarily tall (14m) in urban area so the long-term monitoring system had been installed with 3 tilts-meters and 9 temperature sensors operational from Oct 2004 upto Nov 2007. By using 5-months continuous data in which all the 12 channels were up and running, the two prediction models, 1) the linear model, and 2) the state-space equation (SSE) model, have been identified by finding the best fitness model among all possible 511 combinations of input temperatures out of the 9 temperatures. The linear model which was simple in the model structure achieved the validation fittness of 68% due to the fact that the static model wasn't able to represent thermal dynamics. The SSE model achieved the validation fitness of 90% which was quite accurate considering various unexpected noises happening in field measurements.

Design of Music Recommendation System Considering Context-Information in the Home Network (홈 네트워크에서 상황정보를 고려한 음악 추천 시스템 설계)

  • Song Chang-Woo;Kim Jomg-Hun;Lee Jung-Hyun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.9
    • /
    • pp.650-657
    • /
    • 2006
  • The music is a part of our daily life in these days. And when the people listen to the music, they are affected by the context. However, previous researches on the music recommendation system have the problem that they didn't consider the proper contextual information efficiently. They only used the content-based filtering or the method to use musical metadata (genre, artist, etc.). Recently, there are some researches about the music recommendation system which applies the status(temperature, humidity, etc.) of environments. But, it is difficult to be accepted by the contextual information. Therefore, we propose the music recommendation system that is dynamically applied by the contextual information as well as the metadata in the previous researches. And the system can provide users with the music that they want to listen to, and then the users can be more satisfied. Also, the services can be improved by the feedback of the users. In order to solve this problem, the context-information for selecting a music list is defined and the music recommendation system is designed by using the content-based filtering method. The system is suitable for the user's taste and the context. The music recommendation system we are proposing uses an OSGi framework in the home network. As a result, the satisfaction of users and the quality of services will be improved more efficiently by supporting the mobility of services as well as the distributed processing.

AN EXPERIMENTAL STUDY ON THE CYTOTOXICITY OF CAVITY LINERS (이장재의 세포독성에 관한 실험적 연구)

  • Kim, Jeong-Hye;Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.77-92
    • /
    • 1990
  • The purpose of this study was to evaluate the cytotoxic effects of 6 cavity liners in vitro. Human fibroblasts were cultured in ${\alpha}$-MEM and each liner was manually mixed and filled in glass ring cylinder ($8{\times}8mm$ in diameter, in height). The cylinders filled with the liners were placed in the center of the dish (35mm in diameter) containing 3ml of ${\alpha}$-MEM. Millipore filters (pore size $0.22{\mu}m$) to simulate dentin barrier were also placed between the bottom of cylinder and the dish. Then the culture dishes were stored in 5% $CO_2$ containing incubator for 5 and 10 days at the temperature of $36.6^{\circ}C$. The results of the experiments were analyzed by counting the cells in the period of 5 and 10 days respectively, and were assessed by calculating the cell multiplication rate and the relative growth rate. The experiemntal groups and the control group were compared statistically. The results of the study were summarized as follows: 1. The cell number of Zinc oxide-eugenol was $(4.13{\pm}1.31){\times}10^4$ cells/ml at 5 days and $(4.32{\pm}1.61){\times}10^4$ cells/ml at 10 days. 2. The cell number of Cavitec was ($8.35{\pm}2.87{\times}10^4$ cells/ml and $(10.08{\pm}5.10){\times}10^4$ cells/ml at 5 and 10 days respectively. 3. The cell number of Dycal was $(13.56{\pm}3.89){\times}10^4$ cells/ml at 5 days and $(34.75{\pm}8.85){\times}10^4$ cells/ml at 10 days. 4. The cell number of life was $(11.46{\pm}3.32){\times}10^4$ cells/ml and $(21.92{\pm}6.18){\times}10^4$ cells/ml at 5 and 10 days. 5. The cell number of Base cement was $(13.73{\pm}3.73){\times}10^4$ cells/ml and $(36.68{\pm}5.20){\times}10^4$ cells/ml at 5 and 10 days. 6. The cell number of Dentin cement was $(13.58{\pm}3.90){\times}10$ cells/ml and $(66.95{\pm}24.09){\times}10$ cells/ml at 5 and 10 days. 7. The cell multiplication rate of zinc oxide-eugenol cements was significantly less than that of the calcium hydroxide and glass ionomer cement. (P < 0.05)

  • PDF

MICROLEAKAGE AND MARGINAL HYBRID LAYER OF DENTIN ADHESIVES (상아질 접착제의 미세누출과 변연부 혼화층)

  • Cho, Young-Gon;Kim, Young-Kwan;Ahn, Jong-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.34-43
    • /
    • 2002
  • The purpose of this study was to compare microleakage and marginal hybrid layer in class V restorations using two one-bottle adhesives and one self-etching adhesive. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were pre-pared on buccal and lingual surfaces of 30 extracted human molar teeth. Prepared teeth were randomly divided into three treatment groups (n=30) and restored with three adhesives and composites: Single Bond/Filtek Z-250 (Group 1), Prime&BondNT/Esthet.X (Group 2), UniFil Bond/UniFil F (Group 3). For microleakage, samples were stored in room temperature water for 24 hours, thermocycled stained with 2% methylene blue dye, sectioned into halves, scored and analysed using Mann-whitney test and Wilcoxon signed rank sum test. For marginal hybrid layer, samples were sectioned into halves, treated with 10% phosphoric acid for 5 seconds, stored in 5% NaOCL solution for 24 hours, dried and gold coated. Occlusal and gingival margins of each sample were inspected under SEM. The results of this study were as follows ; 1. Microleakage at the occlusal margins was not evident in group 1 and group 2, but it showed in group 3 (p<0.05). 2. Microleakage in group 1 and group 3 was significantly lower than in group 2 at gingival margins (p<0.05). 3. Microleakage at gingival margins was greater than at occlusal margins in group 1 and group 2, but microleakage at occlusal margins was greater than at gingival margins in group 3 (p<0.05). 4. In group 1 and group 2, no gaps at occlusal margins showed. But gaps showed in group 3. Occlusal margins were free from a hybrid layer in all groups 5. The thickness of the marginal hybrid layers was 2.5~5 $\mu\textrm{m}$ thick in group 5 $\mu\textrm{m}$ thick in group 2 and 1.5 $\mu\textrm{m}$ thick in group 3. 6 There was no corelation between microleakage and thickness of marginal hybrid layer. In coclusion, the effect of dentin adhesives on microleakge in class V composite restorations was excellent when one-bottle adhesives were applied on enamel margin, and it was good when a self-etching adhesive was applied on dentinal margin. There was no corelation between microleakage and thickness of marginal hybrid layer.

MARGINAL MICROLEAKAGE OF SELF-ETCHING PRIMER ADHESIVES AND A SELF-ETCHING ADHESIVE (자가 산부식 프라이머와 자가 산부식 접착제의 변연 미세누출)

  • Cho, Young-Gon;Cho, Kong-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.493-501
    • /
    • 2002
  • This study evaluated the microleakage performance of four self-etcing primer adhesives(Clearfil SE Bond, Clearfil Liner Bond 2, UniFil Bond, and FL Bond) and one self-etching adhesive(Prompt L-Pop). Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 50 extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of five adhesives and composite resins: Prompt L-Pop/Filtek Z 250(Group 1), Clearfil SE Bond/Clearfil AP-X(Group 2), Clearfil Liner Bond 2/Clearfil AP-X(Group 3), UniFil Bond/UniFil F(Group 4), and FL Bond/Filtek Z 250(Group 5). Following one day storage in room temperature water, the restored teeth were thermocycled for 500 cycles between 5$^{\circ}C$ and 55$^{\circ}C$. Marginal microleakage was assessed by dye penetration using 2% methylene blue dye. After 24 hours, the teeth were sectioned longitudinally and evaluated for microleakage under steromicroscope The data were statistically analysed by Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked tests. The results of this study were as follows ; 1. The microleakges at both enamel and dentinal mal$.$gins were the lowest in group 4. increasing among groups in the following order: group 2, follwed by group 5, follwed by group 1, and the highest in group 3. 2. At the enamel margins, the microleakage of group 3 was significantly higher than those of groups 2. 4 and 5(p<0.05), and also the microleakage of group 1 was statistically higher than those of groups 2 and 5(p<0.05). 3. At the dentinal margins, microleakage of group 3 was signincantly higher than microleakages of groups 1, 2, 4 and 5(p<0.05). 4. Compared with microleakages between the enamel and dentinal margins of each group, groups 1, 4 and 5 at enamel margin and group 2 and group 3 at dentinal margin were higher microleakage. But there was no significant difference between enamel and dentinal microleakages of each group(p>0.05).

Thermodynamic Characteristics of Snowfall Clouds using Dropsonde Data During ICE-POP 2018 (ICE-POP 2018 기간 드롭존데 자료를 활용한 강설 구름의 열역학적 특성)

  • Jung, Sueng-Pil;Lee, Chulkyu;Kim, Ji-Hyoung;Yang, Hyo Jin;Yun, Jong Hwan;Ko, Hee Jong;Hong, Seong-Eun;Kim, Seung-Bum
    • Atmosphere
    • /
    • v.30 no.1
    • /
    • pp.31-46
    • /
    • 2020
  • The aircraft observation campaign was performed to investigate thermodynamic conditions of snowfall cloud over the East Sea of Korean peninsula from 2 February to 16 March 2018. During this period, four snowfall events occurred in the Yeongdong region and three cases were analyzed using dropsonde data. Snowfall cases were associated with the passage of southern low-pressure (maritime warm air mass) and expansion of northern high-pressure (continental polar air mass). Case 1 and Case 2a were related to low-pressure systems, and Case 2b and Case 3 were connected with high-pressure systems, respectively. And their thermodynamic properties and horizontal distribution of snowfall cloud were differed according to the influence of the synoptic condition. In Case 1 and Case 2a, atmospheric layers between sea surface and 350 hPa contained moisture more than 15 mm of TPW with multiple inversion layers detected by dropsonde data, while the vertical atmosphere of Case 2b and Case 3 were dry as TPW 5 mm or less with a single inversion inversion layer around 750~850 hPa. However, the vertical distributions of equivalent potential temperature (θe) were similar as moist-adiabatically neutral condition regardless of the case. But, their values below 900 hPa were about 10 K higher in Case 1 and Case 2a (285~290 K) than in Case 2b and Case 3 (275~280 K). The difference in these values is related to the characteristics of the incoming air mass and the location of the snowfall cloud.