• 제목/요약/키워드: Temperature/humidity

검색결과 4,305건 처리시간 0.03초

A Study on the Plasma Biochemical Indices of Heat-Stressed Broilers

  • Lin, H.;Du, R.;Gu, X.H.;Li, F.C.;Zhang, Z.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권9호
    • /
    • pp.1210-1218
    • /
    • 2000
  • Four experiments were conducted to evaluate the effect of temperature and humidity on biochemical indices of Arbor Acres broilers at different weeks of age. The alkaline phosphatase (AKP), acid phosphatase (ACP), lactic dehydrogenase (LD), creatine kinase (CK), plasma glucose (Glu), calcium (Ca), potassium (K), chloride (Cl), urea nitrogen (UN), uric acid (UA), plasma thyroxin (T4), triiodothyronine (T3) and insulin levels were determined in all the four experiments. In experiment 1, the plasma Glu, LD and CK levels were increased by heat exposure ($35{^{\circ}C}$ and 35, 60, or 85% RH, 2 h) and this effect was aggravated by longer exposure (24 h). No significant changes (p>0.05) were found in Ca concentration, activity of AKP and ACP. In experiment 2, temperature (10, 20, 30, $33{^{\circ}C}$) had significant effect on the levels of K, Cl, UN, UA levels and the activity of LD (p<0.01), but had no significant influence on the activity of CK (p>0.05). The UN, UK and LD levels were elevated by low temperature $(10{^{\circ}C})$ (p<0.01), Cl content was increased by high temperature ($(33{^{\circ}C})$ (p<0.01), and K level was decreased by high ($(33{^{\circ}C})$ or low $(10{^{\circ}C})$ temperature and increased by medium temperature $(30{^{\circ}C})$ (p<0.01). The humidity (35, 85% RH) only had significant effect on Cl concentration which was decreased by high humidity (p<0.01). In experiment 3, the result showed that only the LD and CK activity were significantly increased (p<0.01) by high temperature (7, 24, 28, $32{^{\circ}C}$) or high humidity (35, 85% RH). Temperature and humidity had no significant effect on K, Cl, UA, UN and Glu levels (p>0.05). In experiment 4 (24, 27, 30, $33{^{\circ}C}$; 30, 45, 60, 75, 90% RH), plasma T3 level was declined by high temperature $(33{^{\circ}C})$, and this phenomena disappeared in birds under high temperature and high humidity environment. T4 concentration in plasma was not affected by temperature (p>0.05), but was increased by high or low humidity (p<0.01). Neither temperature nor humidity had significant effect on plasma insulin concentration (p>0.05). The results of the four experiments suggested that broilers at different growth periods might have different thermal requirements and would response differently to heat exposure. The plasma biochemical indices themselves had big variation; the reaction of the indices to thermal exposure treatment differed with the age of broilers. The big variation of biochemical indices themselves might cover the response of indices to temperature and humidity treatments.

Electrical impedance-based crack detection of SFRC under varying environmental conditions

  • Kang, Man-Sung;An, Yun-Kyu;Kim, Dong-Joo
    • Smart Structures and Systems
    • /
    • 제22권1호
    • /
    • pp.1-11
    • /
    • 2018
  • This study presents early crack detection of steel fiber-reinforced concrete (SFRC) under varying temperature and humidity conditions using an instantaneous electrical impedance acquisition system. SFRC has the self-sensing capability of electrical impedance without sensor installation thanks to the conductivity of embedded steel fibers, making it possible to effectively monitor cracks initiated in SFRC. However, the electrical impedance is often sensitively changed by environmental effects such as temperature and humidity variations. Thus, the extraction of only crack-induced feature from the measured impedance responses is a crucial issue for the purpose of structural health monitoring. In this study, the instantaneous electrical impedance acquisition system incorporated with SFRC is developed. Then, temperature, humidity and crack initiation effects on the impedance responses are experimentally investigated. Based on the impedance signal pattern observation, it is turned out that the temperature effect is more predominant than the crack initiation and humidity effects. Various crack steps are generated through bending tests, and the corresponding impedance damage indices are extracted by compensating the dominant temperature effect. The test results reveal that propagated cracks as well as early cracks are successfully detected under temperature and humidity variations.

완전제어형(完全制御型) 실험용(實驗用) 작물생육장치(作物生育裝置)의 개발(開發)(I) -온(溫)·습도(濕度) 제어(制御) 시스템- (Development of a Fully-Controlled Phytotrons -Temperature and Humidity Control System-)

  • 이규철;유관희;노상하;홍순호
    • Journal of Biosystems Engineering
    • /
    • 제17권1호
    • /
    • pp.55-64
    • /
    • 1992
  • The aim of this study was to develop a phytotron for studying the effects of environmental factors such as temperature and humidity on plant growth. This equipment consists of the growth chamber, and the measurement and control system including control algorithms required for optimum operation. As the first step of the study, a temperature and humidity control system was developed. The results of this study are summarized as follows ; 1. Pt-100 was selected to measure temperature and a linearized op-amp circuit was developed for signal conditioning. 2. Pt-100 wet bulb thermometer based on Asmann's principle was developed to measure relative humidity. 3. Temperature and relative humidity conditions were controlled by ON-OFF and PWM operation using a PID controller. And an autotuning algorithm using the characteristics of step response was developed to determine optimal PID constants which were independent of the size of apparatus and environmental factors. 4. Under the ambient temperature of $20^{\circ}C{\sim}25^{\circ}C$, the temperature was kept within the error of ${\pm}0.3^{\circ}C$ in the range of $10^{\circ}C{\sim}40^{\circ}C$, and the relative humidity was kept within the error of ${\pm}5%$ in the range of ${\pm}50%{\sim}90%$.

  • PDF

철도 전동차내의 쾌적성 평가에 관한 연구 - 온도 및 습도를 중심으로 - (Evaluation of Comfortableness in Railroad Electric Rolling Stock - Focused on Temperature and Humidity -)

  • 박덕신;배상호;정병철;이주열
    • 한국철도학회논문집
    • /
    • 제6권1호
    • /
    • pp.41-48
    • /
    • 2003
  • Most of people spends their times in indoor about 85% of a day. Thus, indoor is more serious than outdoor concerned with the health. We discussed comfortableness in a railroad electric rolling stock, and focused on temperature and humidity. Electric rolling stock is one of major public transportation system because of an increasing in population and heavy traffic problems. The passengers are under the influence of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system in electric rolling stock should be designed for the health and comfort. One of the main aims is to create an acceptable thermal environment without draught problem. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in electric rolling stork is turbulent. Temperature and humidity gradients in electric rolling stock have been studied. And, the difference between mean temperature and rotative humidity measured at 0.7, 0.9, 1.2, 1.7m above the floor. It has been found that temperature and relative humidity with large fluctuations caused more draught complaints.

Effects of Curing Temperature on Autogenous Shrinkage, Relative Humidity, Pore Structure of Cement Pastes

  • Park Ki-Bong
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.853-856
    • /
    • 2005
  • A low water/cement ratio leads to autogenous shrinkage of cement paste at an early age. This autogenous shrinkage is related to the change of relative humidity in the pore structure that is formed during the hydration process. The relationship between autogenous shrinkage and relative humidity change are relatively well defined today, but the effects of temperature on autogenous shrinkage, relative humidity, and pore structures have been studied less systematically. This study focused on correlating alterations of these properties of cement paste hydrated at constant temperatures of 20, 40, and $60^{\circ}C$. The test results clearly indicate that increasing curing temperature resulted in increased porosity, particularly for pores between 5 to 50 nm as measured by MIP, and increased autogenous shrinkages, as a consequence of a reduction of relative humidity at early ages.

3D 프린팅을 활용한 재료조합에 따른 온습도 변화 분석 (Analysis of Changes in Temperature and Humidity by Material Combination Using 3D Printing)

  • 이희란;김소영;이예진;이옥경
    • 한국의류산업학회지
    • /
    • 제24권1호
    • /
    • pp.127-137
    • /
    • 2022
  • Recently, various clothing items are being developed using 3D printing technology, but comfort has become an issue while wearing them for a long time. Therefore, this study researched on how the temperature and humidity of the devices developed by 3D printing change depending on the material combination. Five types of material combinations (EVA foam, TPU density 10%, TPU density 30%, EVA foam+TPU density 10%, and EVA foam+TPU density 30%) were selected as variables, and the experiment was conducted for two different cases with and without a cover. All the ten types of samples were placed on the hot plate set at 36℃, and the surface temperature and humidity were measured at three different points for 10 minutes. As a result, the case with only TPU showed the greatest temperature change while the case with 100% EVA foam showed the least temperature change. The humidity of the surface layer gradually decreased with time for 100% EVA foam. For the case with TPU materials, the moisture was transferred to the surface layer at first, thereby increasing the humidity but then dropped significantly. Meanwhile, the cases with the cover on showed similar tendencies of change in both temperature and humidity where the overall temperature and humidity delivery were slow.

증발기의 압력강하에 대한 상대습도의 영향 (Effects of Relative Humidity on the Evaporator Pressure Drop)

  • 김창덕;강신형;박일환;이진호
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.397-407
    • /
    • 2004
  • It is well known that some key parameters, such as evaporating temperature, refrigerant mass flow rate, face velocity and inlet air temperature, have significant influence on the evaporator performance. However performance studies related to a humid environment have been very scarce. It is demonstrated that the refrigerant mass flow rate, heat flux, water condensing rate and air outlet temperature of the evaporator significantly increase with air inlet relative humidity. As the air inlet relative humidity increases, the latent and total heat transfer rates increase, but the sensible heat transfer rate decreases. The purpose of this study is to provide experimental data on the effect of air inlet relative humidity on the air and refrigerant side pressure drop characteristics for a slit fin-tube heat exchanger. Experiments were carried out under the conditions of inlet refrigerant saturation temperature of 7 $^{\circ}C$ and mass flux varied from 150 to 250 kg/$m^2$s. The condition of air was dry bulb temperature of 27$^{\circ}C$, air Velocity Varied from 0.38 to 1.6 m/s. Experiments Showed that air Velocity decreased 8.7% on 50% of relative humidity 40% of that at degree of superheat of 5$^{\circ}C$, which resulted that pressure drop of air and refrigerant was decreased 20.8 and 8.3% for 50% of relative humidity as compared to 40%, respectively.

유통중 온습도 변화에 따른 골판지 상자의 압축강도에 대한 연구 (Effect of Relative Humidity and Temperature on the Compression Strength of Corrugated Boxes on Distribution Channel)

  • 이명훈;김종경
    • 펄프종이기술
    • /
    • 제35권2호
    • /
    • pp.33-38
    • /
    • 2003
  • In order to design the high strength corrugated fiberboard containers for agricultural products that can be used for the cold chain system, a large number of individual boxes were placed in various humidity environments at two different temperature of 5 and $20^{\circ}C$. The results indicated that temperature changes do not effect on physical strength of corrugated fiberboard containers as much as humidity changes did. The main conclusion from this study was that compression strength of corrugated fiberboard containers dropped significantly at high humidity condition, but the rates varied depending on the number of walls, temperature, and perimeter of containers. The packaging designer must consider the corrugated fiberboard boxes are also greatly affected by dimensional variations such as the length versus width ratio. Based on this study, water-resistant board would not be necessary if the ambient relative humidity does not reach to a critical point, 85 percent in the cold chain system. However, the designer must count for the unexpected fluctuation of rotative humidity resulting in severe loss of the compression strength of corrugated fiberboard container.

혼합형 고체 추진제 온$cdot$습도 노화 특성 (Temperature and Humidity Aging Characteristics of Composite Solid Propellant)

  • 이경주
    • 한국추진공학회지
    • /
    • 제9권2호
    • /
    • pp.46-53
    • /
    • 2005
  • 혼합형 고체 추진제의 온도 및 습도 가속노화 시험을 수행하여, 그 결과를 분석하였다 수명 평가를 위해서 온도 가속 노화 시험을 수행하였고, 산화제인 AP의 흡습성에 의해 추진제가 연화되는 특성을 분석하기 위해 상대습도 10, 30, $50\%$에서 습도 노화 시험을 수행하였다 온도 가속 노화 시험은 시편을 제작하여 시험하였고, 습도 시험은 실제 모터와 유사한 추진제 블록을 만들어 시험하였다. 온도 가속 노화 결과 $60^{\circ}C$에서 4개월 저장 결과가 $20^{\circ}C$에서 10년 저장한 결과로 예측되었다 HTPB 바인더를 사용한 혼합형 고체 추진제는 시간에 따라 경화되는 경향을 나타내었으며, 상대 습도 $50\%$까지는 습기의 영향이 크게 나타나지 않았다.

비분산 적외선 이산화탄소 가스센서 특성의 온·습도 영향 (Effects of Temperature and Humidity on NDIR CO2 Gas Sensor)

  • 김진호;이승환
    • 센서학회지
    • /
    • 제26권3호
    • /
    • pp.179-185
    • /
    • 2017
  • This article describes the characteristics of nondispersive infrared carbon dioxide gas sensor according to the temperatures and humidifies. In this researches, a thermopile sensor that included application-specific integrated circuit (ASIC) was used and the White-cell structure was implemented as an optical waveguide. The developed sensor modules were installed in gas chamber and then the temperature of gas chamber has been increased from 283 K to 313 K with 10K temperature step. In order to analyze the effects of humidity levels, the relative humidity levels were changed from 30 to 80%R.H. with small humidifier. Then, the characteristics of sensor modules were acquired with the increment of carbon dioxide concentrations from 0 to 2,000 ppm. When the initial voltages of sensors were compared before and after humidifying the chamber at constant temperature, the decrements of the output voltages of sensors are like these: 9mV (reference infrared sensor), 41 mV (carbon dioxide sensor), 2 mV (temperature sensor). With the increment of ambient temperature, the averaged output voltage of carbon dioxide sensor was increased 19 mV, however, when the humidity level was increased, it was decreased 14mV. Based upon the experimental results, the humidity effect could be alleviated by the increment of temperature, so the effects of humidity and temperature could be only compensated by the ambient temperature itself. The estimated carbon dioxide concentrations showed 10% large errors below 200 ppm, however, the errors of the estimations of carbon dioxide concentrations were less than ${\pm}5%$ from 400 to 2,000 ppm.