• Title/Summary/Keyword: Telescopic double crown

Search Result 13, Processing Time 0.017 seconds

Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture (상악의 소수 잔존치와 실패한 하악의 임플란트 오버덴처의 재수복 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • Double crown prostheses can be used in patients who have a few remaining teeth and poor periodontal condition because of secondary splinting of abutments, vertical loading, decrease of the length of lever arm due to fulcrum line located on margin of inner and outer crown. Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth and implant overdenture using a small number of implants have been reported. In this case, there were a few remaining teeth with a very poor periodontal condition in maxilla, and there were a failed implant with severe alveolar bone resorption and shrinkage in the mandible. The main objective of this report is to introduce our case because a double crown partial denture showed satisfactory results in functional and esthetical aspects during more than one-year follow-up period.

Periodontal prosthesis on medically compromised patient with few remaining teeth: hybrid telescopic double crown with friction pin method (의과적 문제가 있고 소수 잔존치를 가지는 환자에서의 치주보철 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.359-365
    • /
    • 2014
  • Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth have been reported in several journals. A double crown removable partial denture can be an alternative treatment for the patients with a poor periodontal condition of remaining teeth. Since a double crown removable partial denture can be applied without the risk of surgical operation to the medically compromised patients with a poor periodontal condition which is inadequate for dental implants, it has psychological and economical advantages. In this case, there were sufficient remaining teeth to be restored with fixed prostheses in maxilla, while there were a few remaining teeth with a very poor periodontal condition so that it was almost impossible to restore with a clasp removable partial denture using these remaining teeth in mandible. In addition, the patient had the medical history of surgical operation due to osteomyelitis in the mandibular anterior areas a year ago, thus difficult to conduct an implant placement. The main objective of this report is to introduce our case because a double crown partial denture using a few mandibular remaining teeth showed satisfactory results in functional and esthetical aspects during more than two years follow-up period in this unfavorable condition.

Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

  • Rinke, Sven;Buergers, Ralf;Ziebolz, Dirk;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.329-337
    • /
    • 2015
  • PURPOSE. This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS. In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS. One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: $5.9{\pm}2.2years$), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION. Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required.