• Title/Summary/Keyword: Telescope System

Search Result 455, Processing Time 0.027 seconds

PHOTOMETRIC OBSERVATIONS OF THE CONTACT BINARY SYSTEM CC COM (접촉쌍성 CC Com의 측광학적 관측과 분석)

  • Jeong, Jang-Hae;Kim, Chun-Hwey;Kim, Yong-Gi
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.2
    • /
    • pp.99-110
    • /
    • 2007
  • A total of 824 observations (206 in ${\Delta}B$, 206 in ${\Delta}V$, 206 in ${\Delta}R$, 206 in ${\Delta}I$ for CC Com were made on 3 nights from March 3 to April 3 in 2002 using the 61cm telescope with 2K CCD camera of the Sobaeksan Optical Astronomy Observatory of KASI. From our observations 9 times of minimum light were newly determined. Combined analysis of our new BVRI light curves with the double-lined radial velocity curves of Pribulla et al. (2007) were made with the 2004 Wilson-Devinney(WD) binary model code to yield new physical parameters of the CC Com system. Small asymmetries in light curves were explained with the adoption of two hot spots on the cool secondary.

Satellite Camera Focus Mechanism Design and Verification (위성용 전자광학카메라의 초점제어시스템 설계 및 검증)

  • Park, Jong-Euk;Lee, Kijun
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.2_1
    • /
    • pp.227-236
    • /
    • 2018
  • The focus control mechanism of the multi-purpose camera can be required for the better quality image acquisition. A good image acquisition through the hardware system including the optics and image sensor, has to be processed before the post correction for improvement of image quality. In the case of the high-resolution satellite camera, the focus control is not a necessity, unlike a normal camera due to a fixed optical system, but may be required due to various reasons. Although there is a basic focus control method using a motor for satellite electronic optical camera, a focus control method using thermal control can be a good alternative because of its various advantages in design, installation, operation, contamination, high reliability and etc. In this paper, we describe the design method and implementation results for the focus control mechanism using the temperature sensor and heater installed in the telescope structure. In the proposed focus control method, the measured temperature information is converted into temperature data by the Kalman filter and the converted temperature data are used in PI controller for the thermal focus control.

PHOTOMETRIC OBSERVATIONS OF THE CONTACT BINARY SYSTEM V523 CASSIOPEIAE (접촉쌍성 V523 Cas의 측광학적 관측과 분석)

  • Jeong Jang-Hae;Kim Chun-Hwey;Lee Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.3
    • /
    • pp.177-188
    • /
    • 2006
  • A total of 920 observations (230 in ${\Delta}B$, 230 in ${\Delta}V$, 230 in ${\Delta}R$, 230 in ${\Delta}I$) for V523 Cas were made on 5 nights from January 6 to 24 in 2003 using the 61cm telescope with 2K CCD camera of the Sobaeksan Optical Astronomy Observatory of KASI. From our observations 9 times of minimum light were newly determined. Combined analysis of our new BVRI light curves with the double-lined radial velocity curves of the Rucinski et al.'s (2003) were made with the 2004 Wilson-Devinney (WD) binary model to yield new physical parameters of the V523 system. Small asymmetries in light curves were explained with the adoption of a cool spot on the hot primary and a hot spot on the cool secondary.

The polarimetric study of (331471) 1984QY1: an asteroid in comet-like orbit

  • Kim, Jooyeon;Ishiguro, Masateru;Bach, Yoonsoo P.;Kuroda, Daisuke;Naito, Hiroyuki;Kim, Yoonyoung;Kwon, Yuna G.;Imai, Masataka;Kuramoto, Kiyoshi;Watanabe, Makoto
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.50.2-50.2
    • /
    • 2017
  • Spatial distribution of atmosphereless bodies in the solar system provides an important clue as to their origins, namely asteroids from Mainbelt or comets from outer solar system. It is, however, difficult to distinguish asteroids and dormant comets due to their similar appearances. In this study, we conducted a unique observation to differentiate asteroids and dormant comets in terms of 'polarimetry'. We observed (331471) 1984 QY1 (hereafter QY1) at large phase angles using the Multi-Spectral Imager (MSI) on the 1.6-m Pirka Telescope from UT 2016 May 25 to June 24. QY1 is a dormant comet candidate in terms of the dynamical properties (i.e. the Tisserand parameter with respect to Jupiter, TJ = 2.68). We analyzed the polarization degree of QY1 as a function of phase angle and found its maximum polarization degree, $Pmax=8.68{\pm}0.28%$ and $8.72{\pm}0.38%$, in RC-and V-band, respectively, around the phase angle of ${\alpha}=100^{\circ}$. In addition, we obtained the geometric albedo, $pV=0.16{\pm}0.02$ by means of an empirical slope-albedo law. The polarimetric properties and the albedo value we acquired are similar to those of S-type asteroids rather than cometary nuclei. In this presentation, we introduce our observation and findings. In addition, we further discuss a dynamical transportation process from Mainbelt to the current orbit.

  • PDF

A Study of Globular Cluster Systems in the Coma, Fornax, and Virgo Clusters of Galaxies from HST ACS and WFC3/IR Imaging

  • Cho, Hyejeon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.29.1-29.1
    • /
    • 2017
  • I present new near-infrared (NIR) photometry of globular cluster (GC) systems associated to a cD galaxy NGC 4874 in the core of the Coma cluster and 16 early-type galaxies in the Fornax and Virgo clusters of galaxies using the Infrared Channel of the Wide Field Camera 3 (WFC3/IR) on board the Hubble Space Telescope (HST). Combining these high-resolution NIR data with new HST Advanced Camera for Surveys (ACS) optical photometry for NGC 4874 and existing ACS GC catalogs from the ACS Fornax and Virgo Cluster Surveys, I have examined for the first time the GC systems in a statistically significant optical/NIR sample of galaxies spanning a wide range of luminosities and colors. A primary goal of this study is to explore empirically whether the distributions of purely optical and hybrid optical - NIR color indices for extragalactic GCs have different forms and whether the relations between these color indices are nonlinear, indicating that they behave differently with underlying metallicity. I find that some GC systems of large galaxies in our sample show color bimodalities that differ between the optical and optical - NIR colors, in the sense that they have disparate ratios of "blue" and "red" peak GCs, as well as differing ratios in their color dispersions. Consistent with these results, I find empirically that the dependence of hybrid optical-NIR color on purely optical color is nonlinear, with an inflection at intermediate metallicities. These findings underscore the importance of understanding the nature of galaxy-to-galaxy variations in the GC color distributions and color-color relations, as well as the exact forms of the color-metallicity transformations, in interpreting the observational data on GC color bimodality. Our ACS data for NGC 4874 shows that its GC system exhibits a very strong blue tilt, implying a very steep mass-metallicity scaling, and the centroid of this GC system is offset by $4{\pm}1kpc$ from the luminosity center of NGC 4874, in the direction of NGC 4872. Finally, I discuss the asymmetrical GC distribution around a dwarf elliptical galaxy in Coma that has a very high relative velocity with respect to the cluster mean at small clustercentric radius.

  • PDF

RELATIVE AGE DIFFERENCE BETWEEN THE METAL-POOR GLOBULAR CLUSTERS M53 AND M92

  • CHO, DONG-HWAN;SUNG, HYUN-IL;LEE, SANG-GAK;YOON, TAE SEOG
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.5
    • /
    • pp.175-192
    • /
    • 2016
  • CCD photometric observations of the globular cluster (GC), M53 (NGC 5024), are performed using the 1.8 m telescope at the Bohyunsan Optical Astronomy Observatory in Korea on the same nights (2002 April and 2003 May) as the observations of the GC M92 (NGC 6341) reported by Cho and Lee using the same instrumental setup. The data for M53 is reduced using the same method as used for M92 by Cho and Lee, including preprocessing, point-spread function fitting photometry, and standardization etc. Therefore, M53 and M92 are on the same photometric system defined by Landolt, and the photometry of M53 and M92 is tied together as closely as possible. After complete photometric reduction, the V versus B − V , V versus V − I, and V versus B − I color-magnitude diagrams (CMDs) of M53 are produced to derive the relative ages of M53 and M92 and derive the various characteristics of its CMDs in future analysis. From the present analysis, the relative ages of M53 and M92 are derived using the Δ(B − V ) method reported by VandenBerg et al. The relative age of M53 is found to be 1.6 ± 0.85 Gyr younger than that of M92 if the absolute age of M92 is taken to be 14 Gyr. This relative age difference between M53 and M92 causes slight differences in the horizontal-branch morphology of these two GCs.

DESIGN AND STRUCTURAL ANALYSIS OF DOME ENCLOSURE FOR TRACKING ARTIFICIAL SPACE OBJECTS (인공우주물체 추적용 완전 개폐형 돔의 설계 및 구조해석)

  • Seol, K.H.;Kim, S.J.;Jang, M.;Min, S.W.;Mun, B.S.;Baek, K.M.
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.4
    • /
    • pp.211-217
    • /
    • 2007
  • We have been making dual dome enclosures which are useful to track artificial space objects at SSNT (Space Science and Technology Lab.) Kyung Hee University. We verified the safety of the dome enclosures using basic design and structure analyses before manufacturing them, and then performed an optimization analysis for economic and safe systems. The dome enclosure has a fully-open type structure to smoothly operate a telescope made in the style of altazimuth mount with very fast tracking. It is also designed to be safe against extreme weather conditions. The general structure of the observatory system consists of the dual dome enclosures at the top of a container. For the structural analyses, we consider the following two methods: (1) gravitational sustain analysis - how the structure supporting the dome withstand the weight of the dome, and (2) wind load analysis that considers the effect of the wind velocity at the region where the observatory is located. The result of overall deformation is found to be less than 0.551mm and the result of equivalent stress is found to be 20.293Mpa, indicating that the dual dome system is reasonably designed. This means structurally to be safe.

MTF and wavefront error testing of large aperture optical system using unequal path interferometer (경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사)

  • Song, Jong-Sup;Jo, Jae-Heung;Lee, Yun-Woo;Song, Jae-Bong;Yang, Ho-Soon;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2005
  • A method for measuring the wavefront error and the modulation transfer function(MTF) of large aperture optics using an unequal path interferometer is presented. A bidirectional shearing interferometer is used for collimation testing of the measurement system. A large aperture Fizeau interferometer with long optical path difference measures the wavefront error of the optics under test by using a $\Phi$ 400 mm off-axis parabolic mirror. The MTF is also measured at the wavelength of the interferometer by changing the laser light into partially incoherent light. Test results of a $\Phi$ 300 mm Cassegrain type satellite telescope made in Korea are presented.

Performance Evaluation of Thermal Control Subsystem of EOS-D Ver.1.0 from In-orbit Telemetry Data (비행 데이터를 이용한 EOS-D Ver.1.0의 열제어계 성능 평가)

  • Chang, Jin-Soo;Kim, Jong-Un;Kang, Myung-Seok;Kim, Ee-Eul;Yang, Seung-Uk;An, Su-Mi
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.70-79
    • /
    • 2016
  • Satrec Initiative successfully developed a high-resolution electro-optical camera system, EOS-D Ver.1.0. EOS-D Ver.1.0 is the main payload of DubaiSat-2 and Deimos-2, which are developed based on the SI-300 platform of Satrec Initiative. After the launch and early operation (LEOP) of DubaiSat-2 and Deimos-2, we performed refocusing for the telescope of EOS-D Ver.1.0 to compensate for the dimensional change of its metering structure by moisture out-gassing. Before and after refocusing, we conducted the performance evaluation of thermal control system(TCS) for EOS-D Ver.1.0 using the in-orbit telemetry data. The evaluation showed EOS-D Ver.1.0 was under well-controlled thermal environment, which demonstrates TCS was designed and developed to meet all requirements.

Verification of Long-distance Vision-based Displacement Measurement System (장거리 영상기반 변위계측 시스템 검증)

  • Kim, Hong-Jin;Heo, Suk-Jae;Shin, Seung-Hoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.47-54
    • /
    • 2018
  • The purpose of this study is to verify the long - range measurement performance for practical field application of VDMS. The reliability of the VDMS was verified by comparison with the existing monitoring sensor, GPS, Accelerometer and LDS. It showed the ability to accurately measure the dynamic displacement by tracking a motion of free vibration of target. And using the PSD function of measured data, the results in the frequency domain were also analyzed. We judged that VDMS is able to identify the higher system mode and has sufficient reliability. Based on the reliability verification, we conducted tests for long-distance applicability for actual application of VDMS. The distance from the stationary target model structure was increased by 50m interval, and the maximum distance was set to 400m. From the distance of 150m, the image obtained by the commercial camcorder has an error in the analysis, so the measured displacement comparison was performed between the LDS and the refractor telescope measurement results. In the measurement results of the displacement area of VDMS, the data validity was deteriorated due to the data shift by the external force and the quality degradation of the enlarged image. However, even under the condition that the effectiveness of the displacement measurement data of VDMS is low, the first mode characteristic included in the free vibration of the object is clearly measured. If the influence from the external environment is controlled and stable data is collected, It is judged that reliability of long-distance VDMS can be secured.