• Title/Summary/Keyword: Telemetry System

Search Result 347, Processing Time 0.043 seconds

ECG Telemetry System by Mobile Communication (이동통신망을 이용한 원격 심전도 시스템)

  • Gu, Ja-Heon;Seo, Hee-Don;Park, Jun-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.15-18
    • /
    • 2002
  • This paper presents an ECG (electrocardiogram) telemetry system, in which patients can be monitored in nearly any environment by mobile communication. The ECG is transmitted to a monitor center via a built-in CDMA modem and forwarded to a cardiologist for diagnosis. Also this paper designed and implemented the receiving server which receives the ECG from the ECG aquisition module of patients by Internet. The server puts the ECG into a database. This telemetry system significantly increases the patient's safety and comfort.

  • PDF

FRONT-END TELEMETRY DATA ACQUISITION UNIT FOR KSLV-I UPPER STAGE

  • Jung Hae-Seung;Kim Joonyun;Lee Jae-Deuk
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.337-340
    • /
    • 2004
  • Upper stage telemetry system of KSLV- I (Korea Space Launch Vehicle I) is composed of MDU (Master Data Unit), RDU (Remote Data Unit), SRU (Shock Recorder Unit) and Transmitter. RDU is the front-end telemetry data acquisition unit which gathers analog/discrete signals from various sensors and other units, and transmits the processed data to MDU via MIL-STD-I553B data bus. In order to acquire useful data from analog signal, signal conditioning circuits, such as anti-aliasing or amplifying, should be implemented. For this purpose, SCM (Signal Conditioning Module) had been developed. This paper describes hardware structure of SCM and analog signal conditioning circuits for various sensors. Also, sampling time scheme for different sampling rates were designed and tested.

  • PDF

Implementation of Implantable Bluetooth Bio-telemetry System for Transmitting Acoustic Signals in the Body with Wireless Recharging Function (무선 충전 가능한 블루투스 방식의 체내 음향신호 전송용 이식형 바이오 텔레메트리 시스템 구현)

  • Lee, Sang-June;Kim, Myoung Nam;Lee, Jyung Hyun;Lim, Hyung-Gyu;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.5
    • /
    • pp.652-662
    • /
    • 2015
  • It is necessary to develop small, implantable bio-telemetry systems which can measure and transmit patients' bio-signals from internal body to external receiver. When measuring bio-signals, like electrical bio-signals, acoustic bio-signal measurement has also a big clinical usefulness. But, sound signal has larger frequency bandwidth than any other bio-signals. When considering these issues, a wireless telemetry system which has rapid data transmission rate proportional to wide frequency bandwidth is necessary to be developed. The bluetooth module is used to overcome the data rate limitation caused by the large frequency bandwidth. In this paper, a novel multimedia bluetooth biotelemetry system was developed which consists of transmitter module located in the body and receiver device located outside of the body. The transmitter consists of microphone, bluetooth, and wireless charging device. And the receiver consists of bluetooth and codec system. The sound inside the skin is captured by microphone and sent to receiver by bluetooth while charging. The wireless charging system constantly supplies the electric power to the system. To verify the performance of the developed system, an in vitro experiment has been performed. The results show that the proposed biotelemetry system has ability to acquire the sound signals under the skin.

The Method for 3-D Localization of Implantable Miniaturized Telemetry Module by Analysis of Nonlinear Differential Equations (비선형 연립방정식에 의한 체내 삽입형 초소형 텔레메트리 모듈의 3차원 위치추적 방법)

  • Park, J.C.;Nam, H.W.;Park, H.J.;Song, B.S.;Won, C.H.;Lee, S.H.;Choi, H.C.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.249-257
    • /
    • 2003
  • The bio-telemetry technologies, that use the wireless miniaturized telemetry module implanted in the human body and transmits several biomedical signal from inside to outside of the body, have been expected to solve the problem such as the patient's inconvenience and the limit for diagnosis. In the case of transceiver system using the wireless RF transmission method, the method of three-dimensional localization for implantable miniaturized telemetry module is necessary to detect the exact position of disease. A new method for three-dimensional localization using small loop antenna in the implantable miniaturized telemetry module was proposed in this paper. We proposed a method that can accurately determine the position of telemetry module by analyzing the differences in the strength of signal, which is received at each of the small size RF receiver array installed on the body surface.

Modeling of Reaction Wheel Using KOMPSAT-1 Telemetry (KOMPSAT-1 Telemetry를 활용한 반작용휠 모델링)

  • Lee, Seon-Ho;Choi, Hong-Taek;Yong, Gi-Ryeok;Oh, Si-Hwan;Rhee, Seung-U
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.45-50
    • /
    • 2004
  • The design of reaction wheel control logic is critical to achieve the spacecraft attitude stabilization and performance requirements for the successful mission. Due to various uncertainties on orbit there exist limitation to obtain the model parameters through the ground tests and to design the associated control logic. Thus, the model parameter correction using on-orbit data is essential to the control performance on orbit. This paper performs the system identification using KOMPSAT-1 telemetry data and extracts the model parameters of the reaction wheel. Moreover, the reaction wheel is remodeled and compared with the ground test results.

A Telemetry System for Ammunition (화포탄용 원격측정 시스템 개발)

  • Han, Dong phil;Kim, Young won;Oh, Jong soo;Kim, Wan Joo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.275-282
    • /
    • 2015
  • Recently, telemetry systems are used to test and evaluate of ammunition. When a transmitting signal from a small transmitter mounted inside the ammunition is sent out, the receiving equipments get real-time RF data. This paper relates to the development of a small high-G endurable transmitter and a portable receiving equipment. The system was tested and confirmed 00 km communication range.

어군행동 원격감시 시스템의 개발에 관한 연구 ( 3 ) - 정치망내에서의 숭어의 행동 - ( Development of the Underwater Telemetry System to Monitor the Behavior of Fish ( 3 ) - Behavior of the Striped Mullet ( Mugil Cephalus ) in Setnet - )

  • 신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.4
    • /
    • pp.283-291
    • /
    • 1994
  • This paper describes about the behavior of the Striped mullet (Mugil cephalus) in the setnet by telemetry techniques. The telemetry system consists of a pinger of 50KHz, three omni-directional hydrophones and ultrasonic receivers, a single board computer for the signal processing, two RF transceivers for the data comunication and a personnel computer. The fish tagged the pinger was tracked by the LBL method, and its location was calculated by the hyperbolic method. The fish escaped from sea surface to 7m deep right after release and had been swum near the sea surface after 30 minutes being released. Also, in horizontal movements, the fish stayed long time around the enterance of the square net in setnet, and showed the escaping behavior repeatly. The average speed of the fish was about 0.41m/sec(1.1 times of the body length)

  • PDF

어군행동 원격감시 시스템의 개발에 관한 연구 ( 2 ) - 양어장에서의 어류 행동 - ( Development of the Underwater Telemetry System to Monitor the Behavior of Fish ( 2 ) - Behavior of the Fish in the Aquafarm )

  • 신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.4
    • /
    • pp.273-282
    • /
    • 1994
  • This paper describes about the behavior of the lseraeli carp (Cyprinus cartio. body length 43cm) and the Red seabream (Chrysophrys major. body length 35cm) aquacultured by telemetry techniques. The telemetry system consists of a pinger of 50kHz, three omni-directional hydrophones and ultrasonic receivers, a single board computer for the signal processing, two RF transceivers for the data communication, and a personnel computer. Those fish tagged the pingers were tracked by the LBL method, and its location was calculated by the hyperbolic method. The average speed of the lsraeli carp was about 1.0 times of the body length in a farming water tank (24$\times$24$\times$1m), and the Red seabream 1.3 times of the body length in a farming raft (10$\times$10$\times$5m). A variation of the speed of the lsraeli carp was higher than the other one.

  • PDF

Description of Range Control System in Space Center

  • Yun, Sek-Young;Choi,Yong-Tae;Lee, Hyo-Keun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.53.2-53
    • /
    • 2002
  • NARO Space Center is being developed as a national project for the Korea Space Development Program. Among the major missions of the Space Center, the Range Control System is the focal point for all command and control operation of the Space Center. The acquired data from the Tracking Stations and the on-site facilities is processed and distributed in the Control Center. Data processing or data fusion is needed for the exact tracking of the Launch Vehicle from several tracking systems. The first phase, which is the best telemetry source is selected among data streams that are received from each telemetry stations using some pre-defined criterion. Trajectory data and major telemetry parameters...

  • PDF