• Title/Summary/Keyword: Teflon

Search Result 526, Processing Time 0.031 seconds

Effect of Oxygen Pressure on the Electrical Properties of ZnO Transparent Thin Films on Flexible Teflon Substrate (산소압력이 테프론 휨성 기판위에 형성된 ZRO 투명박막의 전기적 특성에 미치는 영향)

  • Suh Kwang Jong;Chang Ho Jung
    • Korean Journal of Materials Research
    • /
    • v.15 no.4
    • /
    • pp.271-274
    • /
    • 2005
  • We investigated the crystalline and electrical properties of ZnO thin films for transparent electrode as a function of the oxygen pressures during the deposition. The ZnO thin films were deposited on a flexible teflon substrates by the pulsed laser deposition. From the X-ray diffraction, ZnO films showed c axis oriented ZnO(0002) crystal structure. The FWHM (full width at half maximum) values decreased from $0.51^{\circ}\;to\;0.34^{\circ}$ as the oxygen pressure increased from 0.1 mTorr to 10.0 mTorr showing the improvement of crystallinity. The resistivity and hall mobility of ZnO film deposited at the oxgen pressure of 0.1 mTorr at $200^{\circ}C$ was about $5\times10^{-4}\Omega{\cdot}cm\;and\;20cm^2/V{\cdot}s$, respectively. The optical transmittance of the ZnO films on flexible teflon substrate was found to be above $85\%$.

Photoelastic Determination of Stress Intensity Factors by Teflon Molding Method - Evaluation of The Method In Terms of Two Dimensional Mode I and Mode II - (테프론 모울딩법 에 의한 S .I .F.의 광탄성 실험해석 - 이차원 S .I .F. 문제에 대한 실험방법 의 정도평가 -)

  • 최선호;황재석;채영석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 1983
  • The photoelastic determination of S.I.F. in Fracture mechanics has been regarded as one of the most effective and practical experimental methods in which stresses are read directly, except a few shortcomings involved in the process of experiment; the difficulties of making a sharp crack tip similar to the practical one and nearly impossibilities of carving an arbitrarily shaped crack on the test plate, etc. To eliminate flaws mentioned above, recently, Kitagawa and Watanabe of Tokyo Univ.developed a new method named"Teflon Insert Method". which has improved experimental accuracy to a considerable extent byt remaining still room for further improvement, that is, the elimination of bonding boundary scars which render photoelastic fringes obscure. In this paper, a newly exploited"Teflon Molding Method" was attempted for the completion of teflon-epoxy experimental method. The experimental results obtained by this method are compared with existent theoretical and experimental values to evaluate its accuracy. As result, 1-6% of margin of errors were appeared in a series of photoelastic experiments which defied any other conventional method in terms of experimental accuracy.perimental accuracy.

Study on the Friction Wear Characteristic of the Surface of Door guide rail for Automobile (자동차용(自動車用) Door guide rail 표면의 마찰마모 특성에 관한 연구)

  • Han, Chang-Woo;Son, Jae-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • Door guide rail is the core part which guides window when it moves up and down. But when the method of grease lubrication in the core has been used for a long times, its lubrication performance has been weakened. Therefore the method of the solid lubrication such as teflon(PTFE) coating in the rail has been studied to be increased the performance in these days. In this study the friction wear characteristic the surface with teflon coating of door guide rail for automobile has been researched. In 1, 20 Hz frequency friction wear tests the friction coefficient are below 0.188 and 0.213. In indicate test the wear depth is very slight. Therefore the durability to the friction wear in the surface with teflon coating of door guide rail is good. In addition to, the result of this study can make efficient use to a basic study to develop method of test evaluation to door guide rail surface grade. Especially this study will contribute to improve the quality of automobile parts.

  • PDF

Enhancement of Condensation Heat Transfer of Anodized Aluminum by Teflon Coating and Oil-Impregnation (테플론 코팅과 오일 담지를 이용한 알루미늄 양극산화피막의 응축 열전달 향상)

  • Kang, Minjoo;Lee, Jonghoon;Cha, Soojin;Shin, Yeaji;Kim, Donghyun;Kim, Kyung-Ja;Lee, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.2
    • /
    • pp.90-95
    • /
    • 2021
  • Surface modification technique enabling the control of condensation provides various benefit in various engineering systems, such as heat transfer, desalination, power plants, and so on. In this study, lubricant oil-impregnation into Teflon-coated nanoporous anodic oxide layer of aluminum to enhance a de-wetting and mobility of water droplet on surface. Due to the surface treatment improving water-repellency, the condensation mode is changed to dropwise, thus the frequency of sliding condensed water droplet on surface is increased. For these reasons, the surface of oil-impregnated Teflon-coated nanoporous anodic aluminum oxide shows significantly enhanced condensation heat transfer compared to bare aluminum surface. In addition, the porosity of anodic aluminum oxide affected the mobility of water droplet even with oil-impregnation and Teflon-coating, indicating that the optimization of porous structure of anodic oxide is required for maximizing the condensation heat transfer.

Characterization of Fluorocarbon Thin Films by Contact Angle Measurements (접촉각 측정을 통한 불화 유기박막의 특성 평가)

  • 박진구;차남구;신형재;박장호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.1
    • /
    • pp.39-49
    • /
    • 1999
  • Monolayer thick fluorocarbon films were characterized by the contact angle measurements. The contact angles of three different liquids, water, formamide and diiodomethane were measured on spun coated, vapor phased deposited films and Teflon surface. The highest contact angle over $130^{\circ}$was observed on fluorocarbon films deposited on Al substrates while the lowest angles below $70^{\circ}$deposited on oxide. The surface energies were calculated based on Lewis acid /base theory. The surface energies of Teflon and spin coated FC films were calculated to have 18 and 8.4 dynes /cm, respectively. Higher energies of 31 to .35 dynes /cm were calculated on vapor phase deposited films on silicon and oxide. However vapor phase deposited films on aluminum only showed a large Lewis base energy term. It might be explained by the surface roughness and heterogeneity as observed by dynamic contact angles and AFM measurements.

  • PDF

A Study on Properties of C-V Degradation due to Heating in Teflon (테프론의 가열에 의한 C-V 열화 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.730-735
    • /
    • 2014
  • In this study, the temperature characteristics of electrostatic capacity and dielectric loss for the sample of Teflon film which is degradated at the $120^{\circ}C{\sim}200^{\circ}C$ temperature range in the oven for 10 hours has been measured in through the applied frequency range of 0.1 kHz~4,800 kHz at temperature of $50^{\circ}C$, $90^{\circ}C$, $130^{\circ}C$, $170^{\circ}C$. Also, in the same conditions, the frequency characteristics of electrostatic capacity and dielectric loss for the sample of Teflon film has been measured in through the applied temperature range of $30^{\circ}C{\sim}70^{\circ}C$ on setting frequency of 0.1 kHz, 1 kHz, 10 kHz, 100 kHz. The results of this study are as follows. When the frequency range of 0.1 kHz~4,800 kHz applied to the sample of Teflon film, the electrostatic capacity has been measured at the temperature of $50^{\circ}C$, $90^{\circ}C$, $130^{\circ}C$, $170^{\circ}C$. Through this measurement, it found that the electrostatic capacity decreased with increasing temperature. Regarding this result, may be it is because the electromagnetic coupling is degraded by thermal degradation. When the sample of Teflon film heated at $280^{\circ}C$ for 10 hours in oven, the dielectric loss has changed from unstable status to stabilizing status with increasing the degradation temperature in the $120^{\circ}C$, $160^{\circ}C$, $200^{\circ}C$ range. In this measurement, the two spectrums of dielectric loss appeared. It considers that this spectrum of dielectric loss appeared in 300 Hz is caused by the molecular motion of the C-F or OH group. Through this study, It found that the electrostatic capacity decreased with increasing frequency and temperature, and there is no change in dielectric loss, although the frequency increases.

Bioglue-Coated Teflon Sling Technique in Microvascular Decompression for Hemifacial Spasm Involving the Vertebral Artery

  • Lee, Seong Ho;Park, Jae Sung;Ahn, Young Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.505-511
    • /
    • 2016
  • Objective : Microvascular decompression (MVD) for hemifacial spasm (HFS) involving the vertebral artery (VA) can be technically challenging. We investigated the therapeutic effects of a bioglue-coated Teflon sling technique on the VA during MVD in 42 cases. Methods : A bioglue-coated Teflon sling was crafted by the surgeon and applied to patients in whom neurovascular compression was caused by the VA. The radiologic data, intra-operative findings with detailed introduction of the procedure, and the clinical outcomes of each patient were reviewed and analyzed. Results : The 42 patients included in the analysis consisted of 22 females and 20 males, with an average follow-up duration of 76 months (range 24-132 months). Intraoperative investigation revealed that an artery other than the VA was responsible for the neurovascular compression in all cases : posterior inferior cerebellar artery (PICA) in 23 patients (54.7%) and anterior inferior cerebellar artery (AICA) in 11 patients (26.2%). All patients became symptom-free after MVD. Neither recurrence nor postoperative neurological deficit was noted during the 2-year follow-up, except in one patient who developed permanent deafness. Cerebrospinal fluid (CSF) leak occurred in three patients, and one required dural repair. Conclusion : Transposition of the VA using a bioglue-coated Teflon sling is a safe and effective surgical technique for HFS involving the VA. A future prospective study to compare clinical outcomes between groups with and without use of this novel technique is required.

Development of Teflon Coating Equipment Used in Medical Treatment (의료용 가이드 와이어의 테프론 코팅 장치 개발)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.344-349
    • /
    • 2018
  • This paper proposes a method of designing the main parameters of the Teflon coating equipment of a guide wire used in medical treatment. The proposed device was designed to be guided by a reel-to-reel method in which the guide wire performs all processes continuously, such as Teflon coating and heat treatment. At this time, the conveyed guide wire vibrates between the rollers, which affects the quality of the coating. Therefore, this paper proposes a dynamic equation of the guide wire to be transported in the longitudinal direction, and design parameters setting method of the feed speed and the interval of the roller supporting the wire is proposed to minimize the vibration amplitude of the guide wire during transport. The Teflon coating of the medical guide wire was carried out based on the developed coating equipment. The target coating thickness of the guide wire was set to less than $10{\mu}m$ in the circumferential direction, and the results were examined by optical microscopy.

Effect of Test Board on Insertion Loss of GHz Multilayer LC-Filter (GHz용 적층 LC필터의 삽입손실에 대한 Test Board의 영향)

  • Chun, Myoung-Pyo;Cho, Jung-Ho;Kim, Byung-Ik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.173-175
    • /
    • 2005
  • The effects of PCB Board on the filter characteristics such as insertion loss and transmission characteristics were investigated for the measurement of 5GHz LC filter. Insertion loss measured with PCB Board of Teflon is 0.3 dB lower in comparion with FR-4. The filter characteristics measured in the passband were different from the calculated results. In comparison with the calculated value, the measured value shows that center frequency is 20MHz lower, passband is narrower and insertion loss is larger. The difference of Insertion loss between Teflon and FR-4 increases with increasing measurement frequency.

  • PDF

Surgery of the Infected Patent Ductus Arteriosus with Teflon Wrapping (세균성 동맥내막염을 동반한 개방성 동맥관의 치험예)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.5 no.1
    • /
    • pp.25-28
    • /
    • 1972
  • Patent ductus arteriosus is one of the most common congenital heart diseases, which treated operatively has excellent results. Treatment by surgical means is common and invariably successful. However,infected PDA cases present problems and surgeons operating must face the possibility of adhesions,aneurysmal dilatation and friabiilty of tissue with tearing of the pulmonary arterial end, especially, which causes a fatal hemorrhagic ccmplication. In the earlier days of cardiac surgery, many surgeons deferred operative treatment infected PDA because of frequent complications, high postoperative morbidity and mortality. This continued until Touroff et al. successfully divided the infected PDA in 1940. In 1944, Harper et aI. have used Cellophane for the wrapping of the infected PDA. This surgical procedure has become a single, simple and safe method for treating infected PDA, since that time. In the Teflon wrapping technique, a cardiothoracic team of Yonsei University Severance Hospital used Teflon felt instead of Cellophane in one case of infected PDA and this method proved intractable to antibiotic treatment for 40 days.

  • PDF