• Title/Summary/Keyword: Teflon

Search Result 527, Processing Time 0.027 seconds

Failure Behavior of High Strength Concrete under Uniaxial and Biaxial Compression (고강도 콘크리트의 일축 및 이축 압축하의 파괴거동)

  • Lee, Sang-Kuen;Song, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.223-231
    • /
    • 2002
  • The pilot tests for the development of biaxial failure envelope of high strength concrete of reactor containments were performed. To apply biaxial loads to concrete, the plate specimens were used. The technical difficulties encountered on the development of a suitable biaxial test setup were discussed. To decide the optimum thickness of plate specimen, the nonlinear finite element analyses using ABAQUS were performed for a 1/8 model of cylindrical specimen(${\Phi}150{\times}300$) and four 1/4 models of plate Specimens ($200{\times}200{\times}T$(=30, 50, 60, 70)mm) under uniaxial compression. Analytical values and test data of relative strength ratio between those specimens with different geometric shapes were also compared. The various test data were obtained under uniaxial compression, uniaxial tension, and biaxial compression and then the stress-strain responses were plotted. The test data indicated that the strength of concrete under biaxial compression, $f_1/f_2=-1/-1$, is 15 percent larger than that under uniaxial compression and the poisson's ratio of concrete is 0.16. Teflon pads employed to eliminate friction between test specimen and loading platens showed an excellent effect under biaxial compression.

Case Study on Sound Absorption Rate Measurement Method of PTFE Membrane Material (테프론(PTFE) 막재료의 흡음율 측정방법에 대한 연구)

  • Park, Hye-Na;Kim, Jung-Joong;Shon, Jang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.645-648
    • /
    • 2005
  • The grounds of multipurpose practical use degree are built much holding world cup 2002 but material that is used in this building most external membrane ceiling is accomplishing PTEE A master and servant. Therefore, this research analyzed assessment about sound absorption special quality that measure ventilation quantitys of 10 act material and analyze correlation with Air Permeability and the sound absorption rate, and follow in change of layer of air of inside facts material. Result is as following. When Air Permeability good dimension is 5$\sim$15 cc/cm$^2$/sec and acoustic absorptivity is the best as Air Permeability result that measure acoustic absorptivity of inside facts material particularly firstly, could know 8$\sim$9 cc/cm$^2$/sec love. When establish sound absorption inside facts in external membrane as result that measure acoustic absorptivity of inside (acts material secondly, could know that acoustic absorptivity is good though become about minimum back layer of air 900mm.

  • PDF

Development of Phosphorus-compound $CaSO_4$ : Dy(KCT-300) TL Pellets

  • Yang, Jeong-Seon;Kim, Doo-Young;Kim, Jang-Lyul;Lee, Jung-ll;Kim, Bong-Whan;Chang, Si-Young;Park, Jae-Woo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.142-145
    • /
    • 2002
  • CaSO$_4$:Dy thermoluminescence dosimeter (TLD) is widely used as a personal or environmental dosimeter because of its high sensitivity to radiation. There are many methods to make pellets from the TL phosphorss[l-5]. Sintered pellets were made from a mixture of CaSO$_4$:Dy phosphor and Teflon powder is the most common method. But this method has disadvantage that CaSO$_4$:Dy pellet does not have very high sensitivity because of large amounts of Teflon in Pellets. This Paper described development of a new type of CaSO$_4$:Dy pellets by using P- compounds as a bonding material (KCT-300), and compared the TL sensitivity with that of the commercialized Teledyne CaSO$_4$: Dy pellets. Sensitivity of a new developed KCT-300 shows about 6 times than Teledyne ones, and can be used to measure very low radiation dose.

Evaluation of Effects on Tritium Measurement According to HTO Type Sample Preparation Conditions (HTO 형태 시료 조제 조건에 따른 삼중수소 계측에 미치는 영향 평가)

  • An, Eun-Mi;Kim, Jung-Hoon;Lee, Hong-Yeon;Han, Sang-Jun;Kim, Bo-Gil
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.381-387
    • /
    • 2021
  • In this study, for the measurement of 3H(tritium) radioactivity concentration, a study was conducted on whether the type of cocktail and the material of the vial had an effect on the measurement before liquid scintillation counter measurement on HTO-type samples that had undergone physical and chemical pretreatment. As a result of the study, the efficiency according to the type of cocktail was higher in Ultima Gold LLT than Ultima Flo-AP cocktail with polyethylene (1.49%), glass (5.10%), and teflon (6.58%), respectively. Regarding the effect according to the type of vial, the efficiency and SQP(E) of both Ultima Gold LLT and Ultima Flo-AP showed the highest values in the order of teflon, polyethylene, and glass.

Analysis of Power Generation Characteristics of TENG (Triboelectric Nanogenerator) Suitable for Domestic Transport Environment (국내 수송환경에 적합한 마찰전기 나노발전기의 발전특성 분석)

  • Jong-Min, Park;Hyun-Mo, Jung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.193-199
    • /
    • 2022
  • Sustainable energy supplies without the recharging and replacement of charge storage device have become increasingly important. Among various energy harvesters, the triboelectric nanogenerator (TENG) has attracted considerable attention due to its high instantaneous output power, broad selection of available materials, eco-friendly and inexpensive fabrication process, and various working modes customized for target applications. The TENG harvests electrical energy from wasted mechanical energy in the ambient environment. TENG devices are very likely to be used in next-generation renewable energy and energy harvesting. TENG devices have the advantage of being able to manufacture very simple power devices. In this experiment, various organic dielectrics and inorganic dielectrics were used to improve the open voltage of TENG, Among the various organic dielectrics, Teflon-based FEP, which has the highest electron affinity, showed the highest open voltage and Al electrode was fabricated on Teflon substrate by sputtering deposition process. And AAO (Anodized Aluminum Oxide) nanostructures were applied to maximize the specific surface area of the TENG device. The power generation of TENG within the acceleration level (0.25, 0.5, 1.0, 1.5 and 2 G) and the frequency range (5-120 Hz) of the domestic transport environment was up to 4 V.

Temperature Effect On Warm Deep Drawability of Rectangular Cup Using Local Heating of Dies (금형의 국부적인 가열에 의한 사각통의 온간 디프로드로잉 성형성에 미치는 온도의 효과)

  • Kim, Chang-Ho;Park, Dong-Hwan;Kang, Sung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.5
    • /
    • pp.53-59
    • /
    • 1996
  • Warm deep drawing of single-action dies using local heating has appeared to be an alternative attractive production method of multi-operation die sets generally used at room temperature in deep drawing of rectangular cup. Uniaxial tensile tests and deep drawing tests of various materials are carried out and the effect of temperature on tensile properties and drawability are examined at temperatures up to 200 .deg. C under three kinds of lubricants of teflon film, vinyl film and drawing oil. Good formability is achieved when punch and die temperature were differentiated intentionally in order to get large tensile strength(TS) at punch shoulder protion and small TS at die side. Throughout the experiments, it has been shown that the limiting drawing height of STS316L was increased with heating die and blank holder at 100 .deg. C, but that of STS430 wasn't. When vinyl or teflon film was attached on the plates, the drawability was increased considerably.

  • PDF

Sampling Method for Individual Particle Analysis of Atmospheric Aerosol (개별입자 분석을 위한 대기에어로졸의 시료채취법)

  • Seong-Woo Cheon;Jeong-Ho Park
    • Journal of Environmental Science International
    • /
    • v.33 no.2
    • /
    • pp.113-119
    • /
    • 2024
  • In this study, the most suitable sampling methods for the bimodal mass distribution characteristics and individual particle analysis of atmospheric aerosols were investigated. Samples collected in Quartz, Teflon, and Nuclepore filters were analyzed for individual particles using scanning electron microscopy with an energy-dispersive X-ray spectrometer (SEM/EDS). Then, the pore diameter of the filter and the collection flow rate were determined using the theoretical collection efficiency calculation formula for two-stage separation sample collection of coarse and fine particles. The Nuclepore filter was found to be the most suitable filter for identifying the physical and chemical characteristics of atmospheric aerosols since it was able to separate the sample and count the different sized particles better than either Quartz or Teflon. Nuclepore filters with 8.0 ㎛ and 0.4 ㎛ pores were connected in series and exposed to a flow rate of 16.7 L/min for two-stage separation sampling. The results show that it is possible to separate and collect both coarse and fine particles. We expect that the proposed methodology will be used for future individual particle analysis of atmospheric aerosols and related research.

Teflon Felt Strip Mitral Valve Repair as an Alternative to Expensive Commercial Rings (테플론 펠트를 사용한 승모판막 성형술: 고가의 상업적 제품에 대한 대체물로 가능한가?)

  • Park, Kook-Yang;Jeon, Yang-Bin;Park, Chul-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.216-222
    • /
    • 2008
  • Background: Prosthetic annuloplasty rings are used for the reconstruction of the mitral valve annulus. However, there is controversy over the best ring to use for reconstruction. In this study, we evaluated the long term result of using a Teflon felt strip as an alternative to commercial rings. Material and Method: From 1996 to 2007, we enrolled 47 patients with pure mitral regurgitation greater than grade III. All patients had an ejection fraction of 40% or more. Patients with congenital heart disease or other valvular heart disease were excluded from this study. They were divided into two groups; the commercial ring group (Group CR) and the Teflon felt ring group (Group TF). Result: There was no mortality. The postoperative echocardiography showed no significant change in the overall ejection fraction (from $58.0{\pm}11.2%\;to\;42.8{\pm}8.4%$). There were no significant differences between the two groups with regard to morbidity, the reoperation rate and recurrence of mitral regurgitation greater than grade II. Conclusion: The long term results from this study showed that posterior mitral annuloplasty using Teflon felt had similar results compared to annuloplasty using commercial rings.

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

Significance of Intraoperative BAEPs Monitoring during Microvascular Decompression Surgery (미세혈관 감압술중 뇌간청각유발전위 감시장치의 유용성)

  • Kim, Tae Joon;Ko, Yong;Kim, Young Soo;Oh, Seong Hoon;Kim, Kwang Myung;Kim, Nam Kyu;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.5
    • /
    • pp.635-639
    • /
    • 2000
  • Objective : Surgery for the microvascular decompression is mostly concerned with injury to the cranial nerves or brain stem by cerebellar retraction. Intraopeartive brain stem auditory evoked potentials(BAEPs) has been continuously monitored on surgery to evaluate the extent of injury, recovery of the nerves and prognosis. Methods : Of the 161 cases of CP angle surgery from Feb. 1996 to Apr. 1998, 103 cases were monitored during operation. Thirty five patients who had undergone similar surgery were selected and evaluated ; 23 patients were monitored and 12 were not during surgery. If monitor showed more than 0.5 mSec delay of latency, surgeon was given a warning not to retract brain any more. If more than 1mSec delay, surgeon was informed to stop surgery and wait for the returning of evoked potentials. The level of amplitudes and delay of latencies during the initial stage of operation, opening the dura, insertion of teflon patches, and closing the dura and recovery were then compared. Resuls : Twenty patients were male and 15 were female. Their average age was 50.26 years. Mean amplitude during the initial stage of operation was $0.60{\pm}0.25mV$, at opening the dura $0.56{\pm}0.26$, after teflon patches insertion $0.49{\pm}0.20$, and after closure of dura $0.47{\pm}0.28mV$. Mean latency during the early stage of operation was $6.08{\pm}0.67mSec$, at opening of dura $6.38{\pm}0.55$, insertion of teflon $6.97{\pm}0.59$, and closing the dura $6.17{\pm}0.54$. There was statistical significance in the difference of amplitudes between each procedures, and in the difference of latencies. For the complete recovery of amplitude and latency, it usually took average 5.65 minutes(0-20 min). In monitored group, only one patient required more than 20 minutes to recover and suffered from hearing disturbance after surgery. Others were recovered within 10 minutes without complications. However, 4 out of 12 patients who were not monitored showed hearing disturbance, and 1 patient had temporary facial palsy and dizziness(p=0.000). Conclusion : The results indicate that continuous intraoperative monitoring of BAEPs during CP angle surgery is seen mandatory procedure to prevent operative complications.

  • PDF