• 제목/요약/키워드: Teflon

검색결과 526건 처리시간 0.034초

산소압력이 테프론 휨성 기판위에 형성된 ZRO 투명박막의 전기적 특성에 미치는 영향 (Effect of Oxygen Pressure on the Electrical Properties of ZnO Transparent Thin Films on Flexible Teflon Substrate)

  • 서광종;장호정
    • 한국재료학회지
    • /
    • 제15권4호
    • /
    • pp.271-274
    • /
    • 2005
  • We investigated the crystalline and electrical properties of ZnO thin films for transparent electrode as a function of the oxygen pressures during the deposition. The ZnO thin films were deposited on a flexible teflon substrates by the pulsed laser deposition. From the X-ray diffraction, ZnO films showed c axis oriented ZnO(0002) crystal structure. The FWHM (full width at half maximum) values decreased from $0.51^{\circ}\;to\;0.34^{\circ}$ as the oxygen pressure increased from 0.1 mTorr to 10.0 mTorr showing the improvement of crystallinity. The resistivity and hall mobility of ZnO film deposited at the oxgen pressure of 0.1 mTorr at $200^{\circ}C$ was about $5\times10^{-4}\Omega{\cdot}cm\;and\;20cm^2/V{\cdot}s$, respectively. The optical transmittance of the ZnO films on flexible teflon substrate was found to be above $85\%$.

테프론 모울딩법 에 의한 S .I .F.의 광탄성 실험해석 - 이차원 S .I .F. 문제에 대한 실험방법 의 정도평가 - (Photoelastic Determination of Stress Intensity Factors by Teflon Molding Method - Evaluation of The Method In Terms of Two Dimensional Mode I and Mode II -)

  • 최선호;황재석;채영석
    • 대한기계학회논문집
    • /
    • 제7권1호
    • /
    • pp.1-10
    • /
    • 1983
  • The photoelastic determination of S.I.F. in Fracture mechanics has been regarded as one of the most effective and practical experimental methods in which stresses are read directly, except a few shortcomings involved in the process of experiment; the difficulties of making a sharp crack tip similar to the practical one and nearly impossibilities of carving an arbitrarily shaped crack on the test plate, etc. To eliminate flaws mentioned above, recently, Kitagawa and Watanabe of Tokyo Univ.developed a new method named"Teflon Insert Method". which has improved experimental accuracy to a considerable extent byt remaining still room for further improvement, that is, the elimination of bonding boundary scars which render photoelastic fringes obscure. In this paper, a newly exploited"Teflon Molding Method" was attempted for the completion of teflon-epoxy experimental method. The experimental results obtained by this method are compared with existent theoretical and experimental values to evaluate its accuracy. As result, 1-6% of margin of errors were appeared in a series of photoelastic experiments which defied any other conventional method in terms of experimental accuracy.perimental accuracy.

자동차용(自動車用) Door guide rail 표면의 마찰마모 특성에 관한 연구 (Study on the Friction Wear Characteristic of the Surface of Door guide rail for Automobile)

  • 한창우;손재환
    • 한국산업융합학회 논문집
    • /
    • 제10권1호
    • /
    • pp.33-38
    • /
    • 2007
  • Door guide rail is the core part which guides window when it moves up and down. But when the method of grease lubrication in the core has been used for a long times, its lubrication performance has been weakened. Therefore the method of the solid lubrication such as teflon(PTFE) coating in the rail has been studied to be increased the performance in these days. In this study the friction wear characteristic the surface with teflon coating of door guide rail for automobile has been researched. In 1, 20 Hz frequency friction wear tests the friction coefficient are below 0.188 and 0.213. In indicate test the wear depth is very slight. Therefore the durability to the friction wear in the surface with teflon coating of door guide rail is good. In addition to, the result of this study can make efficient use to a basic study to develop method of test evaluation to door guide rail surface grade. Especially this study will contribute to improve the quality of automobile parts.

  • PDF

테플론 코팅과 오일 담지를 이용한 알루미늄 양극산화피막의 응축 열전달 향상 (Enhancement of Condensation Heat Transfer of Anodized Aluminum by Teflon Coating and Oil-Impregnation)

  • 강민주;이종훈;차수진;신예지;김동현;김경자;이정훈
    • 한국표면공학회지
    • /
    • 제54권2호
    • /
    • pp.90-95
    • /
    • 2021
  • Surface modification technique enabling the control of condensation provides various benefit in various engineering systems, such as heat transfer, desalination, power plants, and so on. In this study, lubricant oil-impregnation into Teflon-coated nanoporous anodic oxide layer of aluminum to enhance a de-wetting and mobility of water droplet on surface. Due to the surface treatment improving water-repellency, the condensation mode is changed to dropwise, thus the frequency of sliding condensed water droplet on surface is increased. For these reasons, the surface of oil-impregnated Teflon-coated nanoporous anodic aluminum oxide shows significantly enhanced condensation heat transfer compared to bare aluminum surface. In addition, the porosity of anodic aluminum oxide affected the mobility of water droplet even with oil-impregnation and Teflon-coating, indicating that the optimization of porous structure of anodic oxide is required for maximizing the condensation heat transfer.

접촉각 측정을 통한 불화 유기박막의 특성 평가 (Characterization of Fluorocarbon Thin Films by Contact Angle Measurements)

  • 박진구;차남구;신형재;박장호
    • 마이크로전자및패키징학회지
    • /
    • 제6권1호
    • /
    • pp.39-49
    • /
    • 1999
  • Monolayer 두께의 불화된 유기박막의 특성을 접촉각 측정을 통해 분석 하였다. 정접촉각을 표면장력의 다른 세 가지의 극성(water, formamide), 비극성(diiodomethane) 용액을 이용하여 Teflon, Spin coating된 FC막, 기상증착된 PFDA와 FC막위에 측정하였다. Aluminum위에 증착된 불화 유기박막이 물에 대해 $130^{\circ}$가 넘는 가장 큰 정접촉각을 나타내었다. 반면에 산화막위에 증착된 유기박막은 $70^{\circ}$미만의 낮은 접촉각을 갖었다. Teflon은 $108^{\circ}$, Spin coating된 막은 $121^{\circ}$로 측정되었다. 이들 측정된 값을 이용 Lewis acid/base 이론에 적용 박막의 표면에너지를 계산한 결과 Teflon의 경우는 18 dynes/cm, Spin coating된 유기박막은 8.4 dynes /cm의 낮은 에너지 값이 계산되었다. 실리콘과 산화막위에 증착된 유기박막은 상대적으로 높은 31~35 dynes /cm의 값을 나타내었으나 aluminum위에 증착된 막에서는 Lewis base 항이 큰 음수 값을 갖는 이례적인 경우가 발생하였다. 이때 음수값을 무시한 경우 계산된 aluminum 상의 증착된 유기박막의 표면에너지 PFDA가 13dynes / cm 이였다. 이는 동접촉각과 AFM 측정결과 다른 표면과는 다르게 aluminum강의 유기박막의 비균질성과 표면의 높은 거칠기에 기인함을 알 수 있었다.

  • PDF

테프론의 가열에 의한 C-V 열화 특성에 관한 연구 (A Study on Properties of C-V Degradation due to Heating in Teflon)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제27권11호
    • /
    • pp.730-735
    • /
    • 2014
  • In this study, the temperature characteristics of electrostatic capacity and dielectric loss for the sample of Teflon film which is degradated at the $120^{\circ}C{\sim}200^{\circ}C$ temperature range in the oven for 10 hours has been measured in through the applied frequency range of 0.1 kHz~4,800 kHz at temperature of $50^{\circ}C$, $90^{\circ}C$, $130^{\circ}C$, $170^{\circ}C$. Also, in the same conditions, the frequency characteristics of electrostatic capacity and dielectric loss for the sample of Teflon film has been measured in through the applied temperature range of $30^{\circ}C{\sim}70^{\circ}C$ on setting frequency of 0.1 kHz, 1 kHz, 10 kHz, 100 kHz. The results of this study are as follows. When the frequency range of 0.1 kHz~4,800 kHz applied to the sample of Teflon film, the electrostatic capacity has been measured at the temperature of $50^{\circ}C$, $90^{\circ}C$, $130^{\circ}C$, $170^{\circ}C$. Through this measurement, it found that the electrostatic capacity decreased with increasing temperature. Regarding this result, may be it is because the electromagnetic coupling is degraded by thermal degradation. When the sample of Teflon film heated at $280^{\circ}C$ for 10 hours in oven, the dielectric loss has changed from unstable status to stabilizing status with increasing the degradation temperature in the $120^{\circ}C$, $160^{\circ}C$, $200^{\circ}C$ range. In this measurement, the two spectrums of dielectric loss appeared. It considers that this spectrum of dielectric loss appeared in 300 Hz is caused by the molecular motion of the C-F or OH group. Through this study, It found that the electrostatic capacity decreased with increasing frequency and temperature, and there is no change in dielectric loss, although the frequency increases.

Bioglue-Coated Teflon Sling Technique in Microvascular Decompression for Hemifacial Spasm Involving the Vertebral Artery

  • Lee, Seong Ho;Park, Jae Sung;Ahn, Young Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권5호
    • /
    • pp.505-511
    • /
    • 2016
  • Objective : Microvascular decompression (MVD) for hemifacial spasm (HFS) involving the vertebral artery (VA) can be technically challenging. We investigated the therapeutic effects of a bioglue-coated Teflon sling technique on the VA during MVD in 42 cases. Methods : A bioglue-coated Teflon sling was crafted by the surgeon and applied to patients in whom neurovascular compression was caused by the VA. The radiologic data, intra-operative findings with detailed introduction of the procedure, and the clinical outcomes of each patient were reviewed and analyzed. Results : The 42 patients included in the analysis consisted of 22 females and 20 males, with an average follow-up duration of 76 months (range 24-132 months). Intraoperative investigation revealed that an artery other than the VA was responsible for the neurovascular compression in all cases : posterior inferior cerebellar artery (PICA) in 23 patients (54.7%) and anterior inferior cerebellar artery (AICA) in 11 patients (26.2%). All patients became symptom-free after MVD. Neither recurrence nor postoperative neurological deficit was noted during the 2-year follow-up, except in one patient who developed permanent deafness. Cerebrospinal fluid (CSF) leak occurred in three patients, and one required dural repair. Conclusion : Transposition of the VA using a bioglue-coated Teflon sling is a safe and effective surgical technique for HFS involving the VA. A future prospective study to compare clinical outcomes between groups with and without use of this novel technique is required.

의료용 가이드 와이어의 테프론 코팅 장치 개발 (Development of Teflon Coating Equipment Used in Medical Treatment)

  • 최정주
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.344-349
    • /
    • 2018
  • 본 논문은 의료용 시술에 사용되는 가이드 와이어의 테프론 코팅 장치의 주요 설계변수 설정방법에 대해 제안하였다. 제안된 장치는 가이드 와이어가 코팅 및 열처리 등을 연속적으로 수행하는 릴투릴(Reel to reel)방식으로 진행되도록 제작되었다. 이때 이송되는 가이드 와이어는 롤러 사이에서 진동을 하게 되고 이는 코팅 품질에 영향을 주게 된다. 따라서 본 논문에서는 길이방향으로 이송되는 가이드 와이어의 동역학 식을 제안하고 이를 바탕으로 이송 시 가이드 와이어의 진동 진폭이 최소화 될 수 있는 이송 속도 및 와이어를 지지하는 롤러의 간격을 설계하였다. 제안된 방법에 의해 제작된 코팅 장치를 바탕으로 의료용 가이드 와이어의 테프론 코팅을 진행하였다. 본 연구에서는 가이드 와이어의 코팅 두께 목표를 원주방향으로 $10{\mu}m$ 이내로 제작될 수 있도록 설정하였고 광학현미경을 사용하여 그 결과를 검토하였다.

GHz용 적층 LC필터의 삽입손실에 대한 Test Board의 영향 (Effect of Test Board on Insertion Loss of GHz Multilayer LC-Filter)

  • 전명표;조정호;김병익
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.173-175
    • /
    • 2005
  • The effects of PCB Board on the filter characteristics such as insertion loss and transmission characteristics were investigated for the measurement of 5GHz LC filter. Insertion loss measured with PCB Board of Teflon is 0.3 dB lower in comparion with FR-4. The filter characteristics measured in the passband were different from the calculated results. In comparison with the calculated value, the measured value shows that center frequency is 20MHz lower, passband is narrower and insertion loss is larger. The difference of Insertion loss between Teflon and FR-4 increases with increasing measurement frequency.

  • PDF

세균성 동맥내막염을 동반한 개방성 동맥관의 치험예 (Surgery of the Infected Patent Ductus Arteriosus with Teflon Wrapping)

  • 조범구
    • Journal of Chest Surgery
    • /
    • 제5권1호
    • /
    • pp.25-28
    • /
    • 1972
  • Patent ductus arteriosus is one of the most common congenital heart diseases, which treated operatively has excellent results. Treatment by surgical means is common and invariably successful. However,infected PDA cases present problems and surgeons operating must face the possibility of adhesions,aneurysmal dilatation and friabiilty of tissue with tearing of the pulmonary arterial end, especially, which causes a fatal hemorrhagic ccmplication. In the earlier days of cardiac surgery, many surgeons deferred operative treatment infected PDA because of frequent complications, high postoperative morbidity and mortality. This continued until Touroff et al. successfully divided the infected PDA in 1940. In 1944, Harper et aI. have used Cellophane for the wrapping of the infected PDA. This surgical procedure has become a single, simple and safe method for treating infected PDA, since that time. In the Teflon wrapping technique, a cardiothoracic team of Yonsei University Severance Hospital used Teflon felt instead of Cellophane in one case of infected PDA and this method proved intractable to antibiotic treatment for 40 days.

  • PDF