• Title/Summary/Keyword: Technology Transfer

Search Result 6,738, Processing Time 0.032 seconds

[ $LaNbO_4$ ] : X (X = Bi, Eu)형광체의 발광 및 저 전압 음극선 발광 특성 (Photoluminescent and low voltage cathodoluminescent properties of $LaNbO_4$ : X (X = Bi, Eu) phosphors)

  • On Ji-Won;Kim Youhyuk
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.1
    • /
    • pp.32-37
    • /
    • 2006
  • Rare-earth niobates, ag (Ln = Y, La, Gd) are well-known self-activated phosphors due to charge transfer in $NbO^{3-}_4$ showing a broad and strong emission band in the spectral region around 410 nm. In order to find new blue and red phosphors for FED, $LaNbO_4$ : X (X = Bi, Eu) phosphors are prepared through solid-state reactions at high temperature. The optimum reaction condition for these phosphors to give maximum emission intensity is obtained when it is first fired at $1250^{\circ}C$ for 2 h followed by second firing at $1400^{\circ}C$ for 1 h. Under irradiation at 254 nm, $1mol\%\;Bi^{3+}$ doped $LaNbO_4$ phosphor shows strong blue emission band with a range of $420\~450nm$. Also $10mol\%\;Eu^{3+}$ doped $LaNbO_4$ phosphor shows the maximum emission intensity at about 610 nm. Emission peaks at $415\~460nm$, $530\~560nm$and $570\~620nm$are observed in phosphors below $10mol\%\;Eu^{3+}$ doped $LaNbO_4$. Similar results are obtained in cathodoluminescent property of these phosphors.

Discharge header design inside a reactor pool for flow stability in a research reactor

  • Yoon, Hyungi;Choi, Yongseok;Seo, Kyoungwoo;Kim, Seonghoon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2204-2220
    • /
    • 2020
  • An open-pool type research reactor is designed and operated considering the accessibility around the pool top area to enhance the reactor utilization. The reactor structure assembly is placed at the bottom of the pool and filled with water as a primary coolant for the core cooling and radiation shielding. Most radioactive materials are generated from the fuel assemblies in the reactor core and circulated with the primary coolant. If the primary coolant goes up to the pool surface, the radiation level increases around the working area near the top of the pool. Hence, the hot water layer is designed and formed at the upper part of the pool to suppress the rising of the primary coolant to the pool surface. The temperature gradient is established from the hot water layer to the primary coolant. As this temperature gradient suppresses the circulation of the primary coolant at the upper region of the pool, the radioactive primary coolant rising up directly to the pool surface is minimized. Water mixing between these layers is reduced because the hot water layer is formed above the primary coolant with a higher temperature. The radiation level above the pool surface area is maintained as low as reasonably achievable since the radioactive materials in the primary coolant are trapped under the hot water layer. The key to maintaining the stable hot water layer and keeping the radiation level low on the pool surface is to have a stable flow of the primary coolant. In the research reactor with a downward core flow, the primary coolant is dumped into the reactor pool and goes to the reactor core through the flow guide structure. Flow fields of the primary coolant at the lower region of the reactor pool are largely affected by the dumped primary coolant. Simple, circular, and duct type discharge headers are designed to control the flow fields and make the primary coolant flow stable in the reactor pool. In this research, flow fields of the primary coolant and hot water layer are numerically simulated in the reactor pool. The heat transfer rate, temperature, and velocity fields are taken into consideration to determine the formation of the stable hot water layer and primary coolant flow. The bulk Richardson number is used to evaluate the stability of the flow field. A duct type discharge header is finally chosen to dump the primary coolant into the reactor pool. The bulk Richardson number should be higher than 2.7 and the temperature of the hot water layer should be 1 ℃ higher than the temperature of the primary coolant to maintain the stability of the stratified thermal layer.

The Convergence effect of job stress of counselors on sexual orientation -Focusing on ego resilience- (성폭력 관련기관 상담원의 직무스트레스가 이직 의도에 미치는 융합적 영향 -자아탄력성 매개중심으로-)

  • Park, Yoo-Beom
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.6
    • /
    • pp.193-199
    • /
    • 2017
  • The research is aimed at finding out the relationship between vocational stress and willingness to engage in vocational stress, which measures vocational stress and the ability to cope with the job, and how the job stress relates to job mobility. First of all, the job stress and willingness to transfer jobs related to sexual harassment related agencies have a positive correlation, while self-exploitation, job stress, and willingness to move jobs have shown negative correlation. Second, the self-assessment of self-assessment of ego resilience has served as a complete parameter in relation to the relationship between employee motivation and willingness to leave the job, which is the job of occupational duties. Based on this study, it is important to note that self-reference is an important factor in determining the role of job stress in the workforce because of its self-reference of job stress and motivation in relation to job stress.

A Preliminary Study on the Fire Safety Testing Method for Fire-resistance Paints Using an X-ray Analysis Method (X-선 분석법을 이용한 내화도료의 화재안전성 평가 방법에 관한 기초연구)

  • Shim, Ji-Hun;Cho, Nam-Wook;Kim, Kang-Woo
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.58-63
    • /
    • 2014
  • Fire-resistance paints are supposed to become intumescent and diminish heat transfer along the steel frames in case of a fire. If unsatisfactory fire-resistance paints which do not satisfy their standard specification are used, it may result in a severe disaster. Because satisfactory fire-resistance paints are hardly discriminated from the unsatisfactory ones by a simple visual inspection, more reliable and convenient onsite evaluation methods are necessary. Here we report the preliminary study result on the fire safety testing method for fire-resistance paints using an X-ray analysis method. It was found that the existence and quantity of effective constituents in fire-resistance paints can be detected by the X-ray analysis method. X-ray fluorescence (XRF) analyses showed that P and Cl elements are much more enriched in fire-resistance paints, compared to normal paints. X-ray diffraction (XRD) analyses showed that ammonium polyphosphate is present as the main crystalline material in fire-resistance paints, but absent in normal paints. The X-ray analysis method is expected to be used for the onsite inspection of fire-resistance paints with the upcoming availability of portable XRF and XRD instruments.

Evaluation of Ground Thermal Conductivity by Performing In-Situ Thermal Response test (TRT) and CFD Back-Analysis (현장 열응답 시험(TRT)과 CFD 역해석을 통한 지반의 열전도도 평가)

  • Park, Moonseo;Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.5-15
    • /
    • 2012
  • In this study, a series of CFD (Computational Fluid Dynamics) numerical analyses were performed in order to evaluate the thermal performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju. The circulation HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The simulation results provide a verification for the in-situ thermal response test (TRT) data. The CFD numerical back-analysis with the ground thermal conductivity of 4 W/mK yielded better agreement with the in-situ thermal response tests than with the ground thermal conductivity of 3 W/mK.

A study on job-satisfaction and Turn-over(Transferability) of Dental Technicians in Korea (한국 치과기공사의 직무만족과 직장이동에 관한 연구)

  • Lim, Byung-Chul
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.71-81
    • /
    • 1989
  • This study was aimed for bettering productivity and technical level of the dental 1 aboratory, and helping the dental technician's benefits and rights, and then endowing them some belonged atmospher and stability on their post by Improving job- satisfaction and maintaining the transferability of one's post at a proper limitation. Therefore, 320 dental technicians extracted randomly from all the technicians working at 494 dental laboratories were subjected for this study. The approach to the study was a way through some postal questionaires executed from March 29, 1988 until May 4, the same year, in which total 254 technicians answered, showing 79% resp"nserate. responserate. The data-analysis was done by a model of the dental technician's transferability from their post, as considering Mobley's(1978)-model of post-transferability, and results through the study are as follows : 1. Satisfaction at a given post showed that the married is better than the unmarried(<0.05), and the experienced is better than the inexperienced(P<0.01). 2. Age, sex, educational experience, and one's service-duration did not affect significantly to the respondent's satisfaction on their post, statistically. 3. Satisfaction at a given post differed in adccordance with given conditions of one's post, i. e.,it stowed high when the monthly payment was good(P<0.05), and when too much duty on their job was given, it was the worst as shown in an example of the next order, too much

  • PDF

Impact of Group Delay in RF BPF on Impulse Radio Systems (임펄스 라디오 시스템에서 RF 대역 통과 필터의 군지연 영향 분석)

  • Myoung Seong-Sik;Kwon Bong-Su;Kim Young-Hwan;Yook Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.380-388
    • /
    • 2005
  • This paper presents analysis results of the effects of RF filter characteristics on the system performance of impulse radio. The impulse radio system transmits modulated pulses having very short time duration and information can be extracted in receiver side based on cross-correlation between received and transmitted pulses. Accordingly, the pulse distortion due to in-band group delay variation can cause serious system performance degradation. In general, RF bandpass filters inevitably cause group delay difference to the signal passing through the filter which is proportional to its skirt characteristic due to its resonance phenomenon. For time as well as frequency domain analysis, small signal scattering parameter $S_{21}$ and its Fourier transform are used to characterize output pulse waveform under the condition that the input and output ports are matched. The output pulse waveform of the filter is predicted based on convolution integral between input pulse and filter transfer function, and resulting BER performances in the BPM and PPM based impulse radio system are calculated.

Extracting Foundation Input Motion Considering Soil-Subterranean Level Kinematic Interaction (지하층-지반 운동학적 상호작용을 고려한 기초저면의 설계지반운동 산정)

  • Sadiq, Shamsher;Yoon, Jinam;Kim, Juhyong;Park, Duhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.11
    • /
    • pp.31-37
    • /
    • 2018
  • Most of tall building systems are composed of above-ground structure and underground structure used for parking and stores. The underground structure may have a pronounced influence on tall building response, but its influence is still not well understood. In a widely referred report on seismic design of tall buildings, it is recommended to model the underground structure ignoring the surrounding ground and to impose input ground motion calculated considering the underground structure-soil kinematic interaction between at its base. In this study, dynamic analyses are performed on 1B and 5B basements. The motions at the base are calculated to free field responses. The motions are further compared to two procedures outlined in the report to account for the kinematic interaction. It is shown that one of the procedure fits well for the 1B model, whereas both procedures provide poor fit with 5B model analysis result.

High-Tech Cluster Evolution and the Role of the Triple-Helix Actors : The Case of the Research Triangle Park, USA (클러스터 진화와 트리플 힐릭스 주체의 역할 - 미국 리서치트라이앵글파크 사례 -)

  • Lee, Chulwoo;Lee, Jong-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.20 no.3
    • /
    • pp.256-258
    • /
    • 2014
  • This paper aims at examining the role of university, industry and government, which constitute the triple-helix innovation system in hi-tech cluster, based on the case of the Research Triangle Park, North Carolina, USA. Firstly, the state government has played a catalytic role by building the horizontal governance of triple-helix actors. By doing so, the state government has made it possible for not only growing but also transforming the RTP as an high-tech cluster. Secondly, universities in the triangle area have played to some extent a limited role in sustaining the evolution of cluster. Thirdly, the RTP has long been dominated by a small group of large firms. However, the situation has been changed since 1990s, because new start-ups from universities and local large firms and the technology transfer activities between universities and firms have been increased in the RTP and its surrounding area. Finally, it argues that the continuous evolution of the RTP has been to some or large extent influenced by the transition from the exogenous development model to the endogenous development model.

  • PDF

A study on the reliability enhancement of Ultrasonic water treatment system to boiler (보일러 초음파 수처리장치의 신뢰성향상에 관한 연구)

  • Kim, Dae-Ryong;Lee, Keun-Oh
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.287-293
    • /
    • 2013
  • This study was carried out to diminish the formation of scale in boilers which is one of the defect elements when they are operating. The defect relating to scale can cause a fatal impact on the explosion of boilers due to the overheating of their tubes, or it can affect the flow of water inside boilers with its bad circulation and result in a disparity of water inside the equipment. Heat transfer in the scale is low comparing to the boiler material, so it can lead to energy losses and has also impact on the global warming. In 2005, the Korean government introduced a system which requires boiler users to install the equipment which can prevent or eliminate the formation of scale to improve the management of water quality in boilers. The study on the techniques for preventing or eliminating the formation of scale started in 1821 and since then subsequently there have been lots of similar studies. The first one was about the scale reduction using potato starch. Since an ultrasonic scale preventer developed by a scientist from a Russian acoustic institute was introduced in1993, a variety of equipment of this kind have been disseminated in Korea. There has been a need to demonstrate the condition for the best performances of such equipment. Boilers are mostly composed of the main body and 288 the tube with a circular curved surface. I carried out a demonstration study on a circular tube which affects the scale defect the most among the boiler components. As a result of it, I found out the fact that the ultrasonic wave needs to reach a certain level of sound pressure and frequency to affect the formation of scale.