A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Comparison of the Survey of Teaching Demand for Distance Education Support for the 2021 and 2022 Academic Years : For D Community Colleges in Daegu (2021학년도와 2022학년도 원격교육지원에 대한 교수 수요도 조사 비교: 대구지역 D전문대학을 대상으로)

  • Park, Jeong-Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.491-497
    • /
    • 2022
  • In this study, we tried to secure basic data to create an environment necessary for distance learning through a survey on professor demand. Among the 184 full-time faculty members of the university, 73 (39.89%) respondents in 2021 and 87 (47.28%) in 2022 were included. As a result of the research on professor demand, in the 2021 school year, 27 people (37%) were classified as LMS improvement items when checking attendance, 38 people (23.3%) were pin-mics as content development support items, and 26 people (35.6%), 33 people (45.2%) of GOM Mix and 25 people (34.2%) of the distance education support center wanted to learn video editing program as the item of video editing program they are currently using. In the 2022 school year, 27 people (31.03%) said mobile upgrade as an LMS improvement item, 52 people (59.8%) of pin-microphone as a content development support item, 33 people (37.9%), but currently using the content creation intention using a studio. As for the video editing program they are working on, 47 people (54%) of GOM Mix Pro and 23 people (26.4%) of the distance education support center want to learn content creation method. In addition, the intention to produce content using the studio for the 2021 and 2022 academic year and the desired educational topic of the distance education support center in the future appeared insignificant (p > 0.05). In this distance education support center, we are working to solve the class of LMS attendance, upgrade mobile, and plan to distribute pin microphones. We are planning to increase the usability of the studio and provide training on how to use video editing programs and how to create video content. In order for a smooth class to take place in a university distance class, the university authorities should seek ways to support the instructor so that he/she does not have difficulties in performing his/her role as a teaching designer, such as setting learning goals, organizing and organizing content, motivating learning, and establishing effective class participation plans. there is a need

Comparison of Image Quality among Different Computed Tomography Algorithms for Metal Artifact Reduction (금속 인공물 감소를 위한 CT 알고리즘 적용에 따른 영상 화질 비교)

  • Gui-Chul Lee;Young-Joon Park;Joo-Wan Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.541-549
    • /
    • 2023
  • The aim of this study wasto conduct a quantitative analysis of CT image quality according to an algorithm designed to reduce metal artifacts induced by metal components. Ten baseline images were obtained with the standard filtered back-projection algorithm using spectral detector-based CT and CT ACR 464 phantom, and ten images were also obtained on the identical phantom with the standard filtered back-projection algorithm after inducing metal artifacts. After applying the to raw data from images with metal artifacts, ten additional images for each were obtained by applying the virtual monoenergetic algorithm. Regions of interest were set for polyethylene, bone, acrylic, air, and water located in the CT ACR 464 phantom module 1 to conduct compare the Hounsfield units for each algorithm. The algorithms were individually analyzed using root mean square error, mean absolute error, signal-to-noise ratio, peak signal-to-noise ratio, and structural similarity index to assess the overall image quality. When the Hounsfield units of each algorithm were compared, a significant difference was found between the images with different algorithms (p < .05), and large changes were observed in images using the virtual monoenergetic algorithm in all regions of interest except acrylic. Image quality analysis indices revealed that images with the metal artifact reduction algorithm had the highest resolution, but the structural similarity index was highest for images with the metal artifact reduction algorithm followed by an additional virtual monoenergetic algorithm. In terms of CT images, the metal artifact reduction algorithm was shown to be more effective than the monoenergetic algorithm at reducing metal artifacts, but to obtain quality CT images, it will be important to ascertain the advantages and differences in image qualities of the algorithms, and to apply them effectively.

A Study of Physicochemical Characteristics and Adsorption properties of Cs and Sr of Natural Zeolite from Kuryongpo in Korea (한국 구룡포산 천연 제올라이트의 이화학적 특성 및 Cs과 Sr 흡착 특성 연구)

  • Bayarsaikhan Battsetseg;Hu Sik Kim;Hyeon Uk Choo;Jong Sam Park;Woo Taik Lim
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.2
    • /
    • pp.117-124
    • /
    • 2023
  • X-ray diffraction analysis, X-ray fluorescence analysis, thermal differential and thermos gravimetric analysis, cation exchange capacity analysis, and Cesium (Cs), Strontium (Sr) adsorption experiments were performed to investigate the physical and chemical properties of natural zeolite from Guryongpo in Korea. As a result of X-ray diffraction analysis, minerals such as mordenite, heulandite, clinoptilolite, and illite are contained, and as a result of X-ray fluorescence analysis, elements such as SiO2, Al2O3, CaO, K2O, MgO, Fe2O3 and Na2O are contained, and the cation exchange capacity was 148.6 meq/100 g. As a result of thermal differential and thermos gravimetric analysis, it was confirmed that the thermal stability was excellent up to 600 ℃. As a result of the adsorption equilibrium experiment over time, the equilibrium was reached within 30 min. for Cesium (Cs) and within 8 hr. for Strontium (Sr), and the adsorption rates of Cesium (Cs) and Strontium (Sr) were 80% and 18%, respectively. As a result of the single-component isothermal adsorption experiment, in conformed to the Langmuir model, and the maximum Cesium (Cs) adsorption amount was 131.5 mg/g, which was high, while the Strontium (Sr) maximum adsorption amount was 29.5 mg/g, which was low. In the case of the natural zeolite used in this study, the content of minerals including 8-rings such as clinoptilolite, heulandite, and mordenite is high, showing high selectivity for Cesium (Cs).

Development of Rabbit Brain Tumor Model Using VX2 Cells and Verification with the MRI in Neuroradiologic Research (Neuroradiology 연구를 위한 VX2 세포를 이용한 토끼 뇌종양 모델 제작과 MRI를 이용한 검증)

  • Yong-Woo Kim;Seon Hee Choi;Hak Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.441-453
    • /
    • 2023
  • Purpose To evaluate the development, location, and volume of a VX2 carcinoma using four inoculation methods in a rabbit brain. Materials and Methods Inoculation of a VX2 cell suspension was performed 1) on the appointed day, 2) seven days after storing a VX2 carcinoma in a freezer or 3) seven days after storing a VX2 carcinoma in a deep freezer after sacrificing the donor rabbits. 4) Without sacrificing the rabbits, the VX2 cell suspension was obtained using a gun biopsy, inoculation was performed on the appointed day. MR imaging was performed 10 days after inoculation. Brain tissues were obtained the day after. The development, location, and volume of the tumor were evaluated. Results Seventeen of the 18 rabbits inoculated on the appointed day developed tumors (average tumor volume, 106.32 mm3). One of five inoculated seven days after storing the VX2 tumor in the freezer, and three of five inoculated seven days after storing the VX2 tumor in the deep freezer developed tumors. Inoculation with a VX2 cell suspension obtained with a gun biopsy from five rabbits revealed development of tumors in only two rabbits. The tumors mostly developed in the superficial cortex. Conclusion TVX2 rabbit brain tumor model is easy to develop and revealed variable reproducibility. This model can be applicable in radiologic imaging, treatment planning, interventional treatment and drug delivery research. VX2 cell can be successfully innoculated into the brain using variable methods under researcher's variable conditions.

The Study on the Independent Predictive Factor of Restenosis after Percutaneous Coronary Intervention used Drug-Eluting Stent : Case on MDCT Calcium-Scoring Implementation Patient (약물용출 스텐트를 이용한 관상동맥중재술 후 재협착의 독립적 예측인자에 관한 연구 : MDCT calcium-scoring 시행 환자 대상으로)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo;Jang, Young-Ill
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.37-44
    • /
    • 2010
  • We sought to confirm an independent factor about in-stent restenosis (ISR) in the patients who underwent drug-eluting stent (DES) and know a possibility as a predictor of measured coronary artery calcium score by MDCT. A total of 178 patients (159 men, $61.7{\pm}10.0$ years of age) with 190 coronary artery lesions were included in this study out of 1,131 patients who underwent percutaneous coronary intervention (PCI) with DES implantation for significant stenosis on MDCT at Chonnam National University Hospital between May 2006 and May 2009. All lesions were divided into two groups with the presence of ISR : group I (re ISR, N = 57) and group II (no ISR, N = 133). Compared to group II, group I was more likely to be older ($65.8{\pm}9.0$ vs. $60.2{\pm}9.9$ years, p = 0.0001), diabetic (21.8% vs. 52.6%, p = 0.0001), have old myocardial infarction (8.8% vs. 2.3%, p = 0.040), left main stem disease (5.3% vs. 0.8%, p = 0.047), and smaller stent size ($3.1{\pm}0.3\;mm$ vs. $3.3{\pm}0.4\;mm$, p = 0.004). Group II was more likely to be smokers (19.3% vs. 42.1%, p = 0.003), have dyslipidemia (8.8% vs. 23.3%, p = 0.019). Left ventricular ejection fraction, lesion complexity, and stent length were not different between the two groups. Total CAC score was $389.3{\pm}458.3$ in group I and $371.2{\pm}500.8$ in group II (p = 0.185). No statistical difference was observed between the groups in CAC score in the culprit vessel, left main stem, left anterior descending artery, left circumflex artery, and right coronary artery. On multivariate logistic regression analysis, left main stem disease (OR = 168.0, 95% CI = 7.83-3,604.3, p = 0.001), male sex (OR = 36.5, 95% CI = 5.89-2,226.9, p = 0.0001), and the presence of diabetes (OR = 2.62, 95% CI = 1.071-6.450, p = 0.035) were independent predictors of ISR after DES implantation. In patients who underwent DES implantation for significant coronary stenosis on MDCT, ISR was associated with left main stem disease, male sex, and the presence of diabetes. However, CAC score by MDCT was not a predictor of ISR in this study population.

A Review of Personal Radiation Dose per Radiological Technologists Working at General Hospitals (전국 종합병원 방사선사의 개인피폭선량에 대한 고찰)

  • Jung, Hong-Ryang;Lim, Cheong-Hwan;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.137-144
    • /
    • 2005
  • To find the personal radiation dose of radiological technologists, a survey was conducted to 623 radiological technologists who had been working at 44 general hospitals in Korea's 16 cities and provinces from 1998 to 2002. A total of 2,624 cases about personal radiological dose that were collected were analyzed by region, year and hospital, the results of which look as follows : 1. The average radiation dose per capita by region and year for the 5 years was 1.61 mSv. By region, Daegu showed the highest amount 4.74 mSv, followed by Gangwon 4.65 mSv and Gyeonggi 2.15 mSv. The lowest amount was recorded in Chungbuk 0.91 mSv, Jeju 0.94 mSv and Busan 0.97 mSv in order. By year, 2000 appeared to be the year showing the highest amount of radiation dose 1.80 mSv, followed by 2002 1.77 mSv, 1999 1.55 mSv, 2001 1.50 mSv and 1998 1.36 mSv. 2. In 1998, Gangwon featured the highest amount of radiological dose per capita 3.28 mSv, followed by Gwangju 2.51 mSv and Daejeon 2.25 mSv, while Jeju 0.86mSv and Chungbuk 0.85 mSv belonged to the area where the radiation dose remained less than 1.0 mSv In 1999, Gangwon also topped the list with 5.67 mSv, followed by Daegu with 4.35 mSv and Gyeonggi with 2.48 mSv. In the same year, the radiation dose was kept below 1.0 mSv. in Ulsan 0.98 mSv, Gyeongbuk 0.95 mSv and Jeju 0.91 mSv. 3. In 2000, Gangwon was again at the top of the list with 5.73 mSv. Ulsan turned out to have less than 1.0 mSv of radiation dose in the years 1998 and 1999 consecutively, whereas the amount increased relatively high to 5.20 mSv. Chungbuk remained below the level of 1.0 mSv with 0.79 mSv. 4. In 2001, Daegu recorded the highest amount of radiation dose among those ever analyzed for 5 years with 9.05 mSv, followed by Gangwon with 4.01 mSv. The area with less than 1.0 mSv included Gyeongbuk 0.99 mSv and Jeonbuk 0.92 mSv. In 2002, Gangwon also led the list with 4.65 mSv while Incheon 0.88 mSv, Jeonbuk 0.96 mSv and Jeju 0.68 mSv belonged to the regions with less than 1.0 mSv of radiation dose. 5. By hospital, KMH in Daegu showed the record high amount of average radiation dose during the period of 5 years 6.82 mSv, followed by GAH 5.88 mSv in Gangwon and CAH 3.66 mSv in Seoul. YSH in Jeonnam 0.36 mSv comes first in the order of the hospitals with least amount of radiation dose, followed by GNH in Gyeongnam 0.39 mSv and DKH in Chungnam 0.51 mSv. There is a limit to the present study in that a focus is laid on the radiological technologists who are working at the 3rd referral hospitals which are regarded to be stable in terms of working conditions while radiological technologists who are working at small-sized hospitals are excluded from the survey. Besides, there are also cases in which hospitals with less than 5 years since establishment are included in the survey and the radiological technologists who have worked for less than 5 years at a hospital are also put to survey. We can't exclude the possibility, either, of assumption that the difference of personal average radiological dose by region, hospital and year might be ascribed to the different working conditions and facilities by medical institutions. It seems therefore desirable to develop standardized instruments to measure working environment objectively and to invent device to compare and analyze them by region and hospital more accurately in the future.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.