• Title/Summary/Keyword: Tc-99m-MAA scan

Search Result 18, Processing Time 0.038 seconds

A Case of Hepatopulmonary Syndrome Diagnosed by $^{99m}Tc-MAA$ Perfusion Lung Scan ($^{99m}Tc-MAA$ 폐관류스캔으로 진단한 간폐증후군)

  • Oh, Hyung-Tae;Lee, Moo-Yong;Song, Il-Han;Park, Seok-Gun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.203-208
    • /
    • 2002
  • In patients with chronic liver disease, hepatopulmonary syndrome, the right to left shunt without previous pulmonary and cardiac disease, can develope and cause respiratory distress. Tools to prove shunt are contrast echocardiography, pulmonary angiography, and $^{99m}Tc-MAA$ perfusion lung scan. Among them, $^{99m}Tc-MAA$ scan is a simple and safe method detecting the right to left shunt. At the same time, quantitation of shunt amount is possible by this method. We report a case of hepatopulmonary syndrome confirmed by $^{99m}Tc-MAA$ scan and contrast echocardiography with review of literlatures.

Hot Spots on Tc-99m MAA Perfusion Lung Scan (Tc-99m 거대응집알부민을 이용한 폐관류 스캔에서 관찰되는 다발성 열소)

  • Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.288-290
    • /
    • 2001
  • A 61 year-old woman underwent perfusion and inhalation lung scan for the evaluation of pulmonary thromboembolism. Tc-99m MAA perfusion lung scan showed multiple round hot spots in both lung fields. Tc-99m DTPA aerosol inhalation lung scan and chest radiography taken at the same time showed normal findings (Fig. 1, 2). A repeated perfusion lung scan taken 24 hours later demonstrated no abnormalities (Fig. 3). Hot spots on perfusion lung scan can be caused by microsphere clumping due to faulty injection technique or by radioactive embolization from upper extremity thrombophlebitis after injection. Focal hot spots can signify zones of atelectasis, where the hot spots probably represent a failure of hypoxic vasoconstriction. Artifactual hot spots due to microsphere clumping usually appear to be round and in peripheral location, and the lesions due to a loss of hypoxic vasoconstriction usually appear to be hot uptakes having linear $borders^{1-3)}$. Although these artifactual hot spots have been well-known, we rarely encounter them. This report presents a case with artifactual hot spots due to microsphere clumping on Tc-99m MAA perfusion lung scan.

  • PDF

A Study on the Intrapulmonary Shunt Measured by $^{99m}Tc$-MAA Perfusion Lung Scan ($^{99m}Tc$-MAA관류폐주사를 이용한 폐내단락에 관한 연구)

  • Choi, Jin-Myung;Kang, Chan-Kyu;Lee, Young-Hyun;Choi, Soo-Bong;Chung, Jae-Chun;Kim, Chong-Suhl
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.163-169
    • /
    • 1986
  • Intrapulmonary shunt was measured by $^{99m}Tc$-MAA perfusion tung scan. The study was included 76 patients. Significant amount of intrapulmonary shunt was observed in the pulmonary disease patients and liver disease patients. The shunt amount was correlated well with $PaO_2$ and $AaDO_2$ level. Further study is needed to search the various factors affecting the amount of intrapulmonary shunt.

  • PDF

A Case of the Hepatic Hydrothorax in the Absence of Ascites Confirmed by Tc-99m Macroaggregated Serum Albumin Scan (Tc-99m MAA scan으로 증명된 복수를 동반하지 않은 간성수흉증 1예)

  • Chung, Jae-Ho;Seo, Hye-Sun;Park, Moo-Suk;Ko, Won-Ki;Lee, Sun-Min;Yang, Dong-Gyoo;Ahn, Chul-Min;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.117-121
    • /
    • 2001
  • Pleural effusion due to hepatic cirrhosis with ascites is well known, although hepatic hydrothorax in the absence of ascites is a rare condition, the pathogenesis of which is still unknown. We report a case of hepatic hydrothorax without ascites confirmed by the intraperitoneal injection of Tc-99m mecroaggregated serum albumin (Tc-99m MAA) that demonstrated the passage of Tc-99m MAA into the right pleural cavity.

  • PDF

$^{99m}TC-MAA$ Pulmonary Perfusion Scan in the Canine Single Luhg Transplant (개에서 시행한 한쪽 이식 폐의 $^{99m}TC-MAA$ 관류스캔)

  • Zeon, S.K.;Ryu, J.G.;Park, C.K.;Yoo, Y.S.;Jung, D.S.;Lee, J.K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.365-371
    • /
    • 1997
  • The aim of this study is to evaluate the efficiency of the pulmonary perfusion scan(Pp scan) in the experimental animal single lung transplantation. Eight left lung transplanted mongrel dogs were included in this study. The serial Pp scan with 111MBq $^{99m}TC-MAA$ were done at the periods of immediate postoperative period, POD 3 days, and POD 10-14 days and finally autopsy was done in each cases. The transplanted lung perfusion was analysed as a percentage radioactivity of trans planted/native lung(T/N) ratio. The Pp scan of a donor mongrel dog was used as a reference(left/right lung (T/N) ratio 85.2%). The average T/N ratio of all cases on immediate postoperative state(reperfusion injury) : 19.2%, three acute rejections. 12.6%, three bronchial dehiscences 6.1% and two pulmonary thromboses : 2.0%. Two cases showed moderate improvement of reperfusion injury as increasing the T/N ratio in POD 3 days Pp scan. The T/N ratio showed sequentially decreased in six cases. As a conclusion, the Pp scan could be a non-invasive method in the evaluation of the experimental one-lung transplanted mongrel dog.

  • PDF

Intraarterial Scintigraphy in Recurrent Cervix Cancer - The Evaluation of Radionuclide Therapeutic Trials - (자궁경부재발암 환자의 국소동맥 주입식 동위원소 검사 -방사성 동위원소의 치료시도를 위한 평가-)

  • Kim, Eun-Young;Suh, Jin-Suck;Park, Chang-Yun;Lee, Jong-Tae;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.293-298
    • /
    • 1990
  • We performed 17 intraarterial scintigraphies in six patients with recurrent cervix cancer. With Seldinger method, the agent (four different radiopharmaceuticals) was perfused at the same speed of infusion of anticancer drugs (25 cc/hour) through internal iliac artery. There were four different radiopharmaceuticals; I-131-Lipiodol, Tc (Technetium)-99m-HSa (Human Serum Albumin), $^{99m}Tc-Sucralfate$ and $^{99m}Tc-MAA$ (Macroaggraegated Albumin). We evaluate the distribution pattern of radioactivity by the use of ratio of Tumor/Extratumor uptake (T/ET ratio). Our results reveals that $^{99m}Tc-MAA$ scan showed the highest T/ET ratio and the other were not ideal agents for intraarterial therapy of recurrent cervix cancer. In conclusion, an ideal radioisotope and tracer which can block capillary, for example MAA, should be re-evaluated or produced in order to treat the patient with recurrent cervix cancer.

  • PDF

Diagnostic Value of Pulmonary Perfusion Scan in Patients of Airway Foreign Body (기관지 이물 환자에서 폐장관류주사(pulmonary perfusion scan)의 적용 의의)

  • 최종욱;정광윤;민헌기;황찬승;김혜정
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.75-81
    • /
    • 1995
  • To evaluate the diagnostic value of pulmonary perfusion scan, we obtained 99mTc MAA per-fusion lung scan from 25 cases of airway foreign bodies. The results were as follows. 1) Significant changes in blood gases were not observed after the establishment of regional hypoperfusion caused by airway foreign body. 2) Near total or total defect was noted on perfusion scan from most of the airway foreign body. 3) There was correspondance of findings of perfusion lung scan and duration of airway foreign body. 4) After the removal of airway foreign bodies, perfusion scan abnormalities were reversed in parallel with the recovery of pulmonary blood flow. We concluded that pulmonary perfusion scan may be valuable for detection of foreign body and reversible hypoperfusion.

  • PDF

Hepatic Arterial Perfusion Scintigraphy with Tc-99m-Macroaggregated Albumin in Hepatocellular Carcinoma (Tc-99m-MAA를 이용한 간세포암의 경동맥 관류스캔)

  • Kim, Gang-Deuk;Sohn, Kwang-Joon;Min, Kyung-Yoon;Kwon, Young-Mi;Kim, Chang-Guhn;Noh, Byung-Suk;Won, Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.350-356
    • /
    • 1994
  • Purpose : Hepatic arterial perfusion scintigraphy with Tc-99m-macroggregated albumin (HAPS) study was carried out in 16 patients with hepatocellular carcinoma(HCC) and in six patients without liver tumor to evaluate HAPS findings of hepatocellular carcinoma and usefullness of HAPS. Materials and Methods : HAPS with planar and SPECT study were performed in 22 patients after conventional hepatic or celiac arteriography. For HAPS study, 4-5 mCi of MAA mixed with 2ml of saline was injected into proper hepatic artery or its distal branches at the rate of approximately 1ml/sec. We analysed 21 HCCs over 2cm in diameter(average diameter; 6.4cm) and 17 of 21 HCCs were over 4cm in diameter(Table 1). CT, sonography and angiography were performed within two week in all 16 patients and liver scan was performed in 12 patients. Results : Three different pattern of tumor perfusion were observed in 16 patients with HCC (Table 2). 1) diffuse increased perfusion in 16 of 21(76%)(Fig. 1) 2) increased peripheral perfusion in 4 of 21(19%) (Fig. 2) 3) diffuse decreased perfusion in 1 of 21 (5%) Arteriovenous shunt indicated by lung uptake of MAA were observed in 9 of 16(56%)(Fig. 4). In contrast, angiography demonstrates arteriovenous shunt in 2 of 16(13%). There was no accumulation of radioactivity on RBC-blood pool scan in all six patients with HCC examined (Fig. 1). Conclusion : HAPS is useful study in evaluation of perfusion pattern or vascularity of HCC and in detection of arteriovenous shunt.

  • PDF

Comparison of Inhalation Scan and Perfusion Scan for the Prediction of Postoperative Pulmonary Function (수술후 폐기능 변화의 예측에 대한 연무 흡입스캔과 관류스캔의 비교)

  • Cheon, Young-Kug;Kwak, Young-Im;Yun, Jong-Gil;Zo, Jae-Ill;Shim, Young-Mog;Lim, Sang-Moo;Hong, Sung-Woon;Lee, Choon-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.111-119
    • /
    • 1994
  • Background: Because of the common etiologic factor, such as smoking, lung cancer and chronic obstructive pulmonary disease are often present in the same patient. The preoperative prediction of remaining pulmonary function after the resectional surgery is very important to prevent serious complication and postoperative respiratory failure. $^{99m}Tc$-MAA perfusion scan has been used for the prediction of postoperative pulmonary function, but it may be inaccurate in case of large V/Q mismatching. We compared $^{99m}Tc$-DTPA radioaerosol inhalation scan with $^{99m}Tc$-MAA perfusion scan in predicting postoperative lung function. Method: Preoperative inhalation scan and/or perfusion scan were performed and pulmonary function test were performed preoperatively and 2 month after operation. We predicted the postoperative pulmonary functions using the following equations. Postpneurnonectomy $FEV_1$=Preop $FEV_1x%$ of total function of lung to remain Postlobectomy $FEV_1$=Preop $FEV_1{\times}$(% of total 1-function of affected lung${\times}$$\frac{Number\;of\;segments\;to\;be\;resected}{Number\;of\;segments\;of\;affected\;lung})$ Results: 1) The inhalation scan showed good correlations between measured and predicted $FEV_1$, FVC and $FEF_{25-75%}$. (correlation coefficiency; 0.94, 0.91, 0.87 respectively). 2) The perfusion scan also showed good correlations between measured and predicted $FEV_1$, FVC and $FEF_{25-75%}$. (correlation coefficiency; 0.86, 0.72, 0.87 respectively). 3) Among three parameters, $FEV_1$ showed the best correlations in the prediction by lung scans. 4) Comparison between inhalation scan and perfusion scan in predicting pulmonary function did not show any significant differneces except FVC. Conclusion: The inhalation scan and perfusion scan are very useful in the prediction of postoperative lung function and don't make a difference in the prediction of pulmonary function a1though the former showed a better correlation in FVC.

  • PDF

A Study on the Measurement of Intrapulmonary Shunt in Liver Diseases by the Nucleotide Method (핵의학적 방법에 의한 간질환자(肝疾患者)의 폐장내 단락양 측정에 관한 연구)

  • Yun, Sung-Chul;Ahn, Jae-Hee;Choi, Soo-Bong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.199-205
    • /
    • 1987
  • The fact there are increase of intrapulmonary arterioveneous shunt amount in the liver cirrhosis patient has been known since 1950. And the method of shunt amount calculation by radionuclide method using $^{99m}Tc-MAA$ was introduced in the middle of 1970. We measured intrapulmonary shunt amount by means of perfusion lung scan using $^{99m}Tc-MAA$ in the various type of liver diseases especially in chronic liver diseases and acute liver disease. The results were as followed. 1) The amount of arteriovenous intrapulmonary shunt in the total case of liver disease was $9.3{\pm}3.9%$, and that of in the control group was $4.6{\pm}2.1%$. 2) The amount of arteriovenous intrapulmonary shunt in the chronic liver disease was $10.8{\pm}4.4%$, and that of in the acute liver disease was $7.2{\pm}2.8%$. We observed significant differences between normal control group and liver disease group, and between chronic liver disease group and acute liver disease group in the amount of shunt by the nucleolide method.

  • PDF