• Title/Summary/Keyword: Tc-99 m Pertechnetate

Search Result 66, Processing Time 0.026 seconds

Effect of Propranolol on Portal Vein Pressure in Patients with Chronic Liver Disease: Evaluation by Perrectal Portal Scintigraphy (만성 간질환에서 Propranolol의 문맥압 감소 효과: 경직장 문맥 신티그라피를 이용한 평가)

  • Rho, Young-Ho;Han, Shin;Kim, Hak-Su;Yoon, Su-Jin;Kim, Yun-Kwon;Kim, So-Yon;Kim, Yeong-Jung;Cho, Min-Koo;Park, Byong-Yik;Lee, Gwon-Jun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.388-397
    • /
    • 1999
  • Purpose: Propranolol is known to decrease portal pressure by reducing blood flow of portal vein. Perrectal portal scintigraphy with Tc-99m pertechnetate has been introduced to evaluate the portal circulation and early diagnosis of liver cirrhosis. We evaluated the effects of propranolol on portal circulation by using per-rectal portal scintigraphy. Materials and Methods: We analyzed the portal hemodynamics by per-rectal portal scintigraphy in 51 patients with liver cirrhosis, 10 chronic hepatitis and 10 normal subjects. 38 patients with cirrhosis underwent per-rectal portal scintigraphy before and after propranolol medication. Perrectal portal scintigraphy was performed after per-rectal administration of 370 MBq of Tc-99m pertechnetate. The shunt index was calculated as the ratio, expressed as a percentage of heart radioactivity to the sum of heart and liver radioactivity during the first 30 seconds. Results: The shunt index in 40 patients with cirrhosis ($59.8{\pm}27.2%$) was significantly higher than that of normal control ($5.0{\pm}1.2%$. p<0.01) and chronic hepatitis ($11.4{\pm}3.5%$, p<0.01). Shunt index was significantly different according to Child's classification and the degree of esophageal varix (p<0.01). After propranolol medication, shunt index was significantly decreased from $59.9{\pm}27.3%$ to $51.3{\pm}15.3%$ (p<0.01) in 38 patients with liver cirrhosis. There was no significant difference of the amount of shunt index reduction after propranolol according to Childs' classification and the degree of esophgageal varix. Conclusion : The effect of propranolol on portal circulation was demonstrated as decreasing shunt index on per-rectal portal scintigraphy in patients with liver cirrhosis. Per-rectal portal scintigraphy may be useful to evaluate the portal circulation and to predict the effect of propranolol in patients with liver cirrhosis.

  • PDF

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF

Evaluation of Extraosseous Abnormalities Detected in Bone Scan ($^{99m}Tc-Methylene$ Diphosphonate (MDP)골(骨)스캔에서 골격외(骨格外) 섭취(攝取) 및 신요로계(腎尿路系) 이상소견(異常所見)에 관(關)한 연구(硏究))

  • Rhim, Sang-Moo;Park, Ran-Jae;Kim, Byung-Tae;Lee, Myung-Chul;Cho, Bo-Yeon;Lee, Hong-Kyu;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 1982
  • The purpose of the present study is to evaluate the clinical and diagnostic significance of incidental findings of renal and urinary tract abnormalities, and extraosseous uptake of bone scans. The authors analyzed bone scans using $^{99m}Tc-MDP$(methylene diphosphonate) in 1238 cases of bone disease from April, 1979 to March, 1981. The results obtained were as follows. 1. Total extraosseous abnormalities were 112 cases (9%), which include 64 cases (5%) of renal and urinary tract abnormalities and 48 case(4%) of other extraosseous uptakes. 2. Renal and urinary tract abnormalities were 32 cases(50%) of obstruction, 14 cases(22%) of nonvisualization, 6 cases of space occupying lesion in kidney, 8 cases of kidney displacement and 4 cases of urinary bladder deformities. 3. Other extraosseous uptakes were 16 cases (33%) of body fluid collection, 15 cases of tumor uptake, 9 cases of free pertechnetate uptake and 8 others.

  • PDF

$^{99m}Tc-Pertechnetate$ Thyroid Scan Findings of Thyroid Cancer (갑상선암의 갑상선주사 소견)

  • Kim, Jong-Deok;Kim, Sang-Soon;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.165-173
    • /
    • 1989
  • 1983년 1월 부터 1987년 12월까지 5년간 부산의 세곳 대학병원(부산의대, 고신의대, 인제의대)에서 병리조직학적으로 확진된 갑상선암 629예중 병력지 관찰이 가능하였던, 478예를 분석하여 1988년 보사부에서 발행한 Five Years' Report for Cancer Registry Programmme in Republic of Korea (1982 7. 1$\sim$1987. 6.30)의 발생빈도와 비교하였으며, 478예중 311예의 갑상선주사 소견을 분류하여 다음과 같은 결과를 얻었다. 1) 전체 악성암에 대한 갑상선암의 발생빈도는 2.54%(629/24.749)이었으며 이는 한국인에 있어서의 발생빈도와 거의 같았다(2.5%). 2) 여자에서 5배 이상 발생하여 (1 : 5.64) 이것 역시 한국인에서의 성별빈도와 매우 유사하였다(1 : 5.22). 3) 연령분포는 10세에서 91세까지로서 87.03%가 20세에서 59세 사이에 있었다. 4) 유두상암이 가장 흔하였고(78.24%),다음이 여포상암(14.44%) 그 다음이 미분화암(22.30%) 이었다. 5) 갑상선주사 소견상 대부분의 암은 solitary cold nodule을 보였다(82.96% : 258/311).

  • PDF

A Case of Thyroid Hemiagenesis (갑상선 반쪽 무형성증 1례)

  • Kim, Joon-Sung;Lee, Kyung-Yeon;Kim, Ja-Hyeong;Park, Sang-Kyu;Jeong, Jin-Young;Oh, Ki-Won
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.244-247
    • /
    • 2009
  • Thyroid hemiagenesis is a rare congenital anomaly in which one thyroid lobe fails to develop. Thyroid hemiagenesis usually does not cause clinical symptoms by itself, therefore, this anomaly is detected incidentally during the evaluation of other thyroid disorders. We describe a rare case of thyroid hemiagenesis in a 1-month-old female infant who presented with prolonged jaundice and abnormal laboratory findings of congenital hypothyroidism. The patient showed the characteristic features of thyroid hemiagenesis of the left lobe in Tc-99m pertechnetate scintigraphy and ultrasonography of the thyroid gland. The patient has improved with supportive care, including thyroid hormone replacement. Further long-term follow-up is required for the investigation of recurrence of thyroid abnormalities.

The Change of the Salivary Function after the High Dobe Radioiodine Treatment in the Patients with Differentiated Thyroid Cancer (갑상선암 환자의 방사성옥소 치료 후 타액선 기능의 변동)

  • Lim, S.M.;Hong, S.W.;Lee, J.O.;Kang, T.W.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.7-12
    • /
    • 1989
  • The pain, swelling of salivary glands and dry mouth are not infrequent complication of the high dose radioiodine treatment in the patients with differentiated thyroid cancer. The purpose of this study was, by the dynamic salivary scintigraphy, to observe the change of the salivary function after the high dose $(150\sim200mci)$ radioiodine treatment. From May 1987 to April 1988, the dynamic salivary scintigraphy with 5mci of $^{99m}Tc-pertechnetate$ and gamma camera was performed before and 7 days after the radiolodine treatment in 7 patients with differentiated thyroid cancer. Just after the dynamic scintigraphy, the stimulation test with vitamin C solution of pH3.0 and poststirnulation scintigraphy were done, and the radioactivity uptake index, excretion fraction and salivary clearance after the stimulation were calculated for each gland. There was positive correlation between the radioactivity uptake index and excretion fraction after the stimulation. The salivary clearance after the stimulation was $18.96{\pm}8.95ml/min$ in the pretreatment state, and $14.37{\pm}7.7ml/min$ after the radioioine treatment. After the radioiodine treatment, the radioactivity uptake index, excretion fraction and salivary clearance after the stimulation were significantly reduced in the parotid glands, but only the excretion fraction was reduced in the submandibular glands. The more the pretreatment salivary clearance after the stimulation was, the % change after the treatment was smaller. Further studies on the relation between the radiation dose in the salivary glands and the change of their function, and the long-term observation for the recovery of function are expected.

  • PDF

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

Clinical Features of Complicated Meckel's Diverticulum Requiring Operation in Children (소아에서 수술을 요한 멕켈게실의 임상상)

  • Lee, Seong-Cheol;Mok, Woo-Kyun;Seo, Jung-Min;Jung, Sung-Eun;Park, Kwi-Won;Kim, Woo-Ki
    • Advances in pediatric surgery
    • /
    • v.1 no.1
    • /
    • pp.33-39
    • /
    • 1995
  • The incidence of Meckel's diverticulum(MD) in general population has been assessed as 2 percent. The major complications of MD are bleeding, perforation, and intestinal obstruction. In spite that the complication rate of Meckel's diverticulum is relatively high(about 4.2% during a lifetime), the preoperative diagnostic rate of complicated MD is very low. Authors investigated the clinical characteristics of complicated MD to improve the diagnostic rate. 16 patients with complicated Meckel's diverticulum who were operated upon at the Department of Pediatric Surgery, Seoul National University Children's Hospital from June 1985 to December 1993 were reviewed. Among the 16 patients with complicated MD, 12 patients(75%) were under 2 year-old and male were predominant(88%). The most common complication was bleeding patients with bleeding MD (8 cases) were diagnosed preoperatively as MD. 8 patients with other complications(perforation : 4 cases, obstruction : 4 cases) could not be suspected as complicated MD except one patient who had previous history of melena. These patients were diagnosed after exploratory laparotomy under the various impression other than MD. Among 12 patients with ulcer related complications such as bleeding and perforation, heterotopic gastric mucosa was found in 11 patients. In conclusion, in any children with unexplained acute abdomen, especially under 2 years old, complicated MD must be included in differential diagnosis. In children with obscure lower gastrointestinal bleeding, $^{99m}Tc$-pertechnetate scintigraphy is a useful diagnostic tool to rule out bleeding MD.

  • PDF

Radionuclide Penogram in Diagnosis of Vasculogenic Impotence (혈관성 발기부전의 진단을 위한 방사성핵종 음경촬영술)

  • Lee, Jae-Tae;Kim, Kwang-Won;Ha, Sung-Woo;Lee, Kyu-Bo;Whang, Kee-Suk;Yoon, Yeo-Deuk;Park, Yoo-Kyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.209-214
    • /
    • 1989
  • Yasculogenic impotence is produced by abnormalities of vascular blood supply or drainage, and is the most common cause of various organic impotences. An increasing awareness of vascular causes of impotence has resulted from development of various diagnostic tests, but precise measurement of penile blood flow is difficult. Radionuclide penogram has been introduced recently to diagnose vasculogenic impotence. Forty-one impotent patients and 12 normal men were studied with radionuclide erection penogram using Tc-99m pertechnetate and an intracavernous injection of papaverine. We defined arteriogenic impotence as arterial index less than 0.66, and venogenic impotence as venous index greater than 0.09. By this criteria, the false positive ratio in normal men was 17%, and the false negative ratio in radically cystectomized patients was 0%. Side effects were small purpura of the penile shaft and dull pain during injection of papaverine. The radionuclide erection penogram was noninvasive and gave a dynamic evaluation of the arterial supply, venous drainage, and blood flow in the corporeal bodies. This method should be considered as a valuable adjunct to evaluate patients with vasculogenic impotence.

  • PDF

Diagnostic Validity of RI Angiocardiography in Cardiac Diseases (심질환(心疾患)의 RI angiocardiography에 관한 진단적(診斷的) 가치(價値))

  • Kim, Kwan-Yop;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.6 no.2
    • /
    • pp.21-39
    • /
    • 1972
  • The employment of gamma-ray scintillation camera with the use of short-lived radioisotopic pharmaceuticals, sucu as $^{99m}Tc$ sodium pertechnetate, have enabled us to perform RI (radioisotopic) angiocardiography. Although conventional cardiac catheterization or angiocardiography using contrast media have been an important diagnostic tool, they may carry some risks or serious complications. The author investigated on RI angiocardiography in twelve normal and twenty five patients with cardiovascular diseases in an effort to evaluate its diagnostic value. The results obtained with this study are as follows; 1. In normal subjects, the scintillation camera transit time of arm-to-right heart was found to be $2.1{\pm}0.67$ seconds, right heart-to-lung $1.5{\pm}0.40$ seconds and lung-to-left heart $3.5{\pm}0.86$ seconds. 2. Transformation or displacement of the heart and the great vessel are easily discriminated by RI angiocardiography. Both in the cases with tricuspid atresia and tetralogy of Fallot, ventricular septal defects are well recongnized by sequential RI angiocardiography. 3. It is also helpful in determinining the site and extent of obstruction, and estimatiing the postoperative course both in the cases with superior vena cava syndrome and pulmonary stenosis. 4. Pericarditis with effusion is readilly diagnosed by RI angiocardiogram showing characteristic "dead space" between intracardiac and intrapulmonary radioactivity. 5. It was found that the diagnostic accuracy of this study was 78.4%. It is concluded that above results obtained are useful and accurate enough for the diagnostic screening methode for clinical practice.

  • PDF