• Title/Summary/Keyword: Tau imaging

Search Result 33, Processing Time 0.027 seconds

Role of MR Neurography for Evaluation of the Lumbosacral Plexus: A Scoping Review (요천추 신경총에 대한 자기공명신경조영술의 역할: 주제 범위 문헌고찰)

  • Seon Gyeong Kim;Joon-Yong Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1273-1285
    • /
    • 2022
  • Purpose MR neurography (MRN) is an imaging technique optimized to visualize the peripheral nerves. This review aimed to discover an optimized protocol for MRN of the lumbosacral plexus (LSP) and identify evidence for the clinical benefit of lumbosacral plexopathies. Materials and Methods We performed a systematic search of the two medical databases until September 2021. 'Magnetic resonance imaging', 'lumbosacral plexus', 'neurologic disease', or equivalent terms were used to search the literature. We extracted information on indications, MRN protocols for LSP, and clinical efficacy from 55 studies among those searched. Results MRN of the LSP is useful for displaying the distribution of peripheral nerve disease, guiding perineural injections, and assessing extraspinal causes of sciatica. Three-dimensional short-tau inversion recovery turbo spin-echo combined with vascular suppression is the mainstay of MRN. Conclusion Future work on the MRN of LSP should be directed to technical maturation and clinical validation of efficacy.

An optimized radiosynthesis of 18F-THK-5351 for routine production on TRACERlab™ FXFN

  • Park, Jun Young;Son, Jeongmin;Yun, Mijin;Chun, Joong-Hyun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.91-97
    • /
    • 2017
  • $^{18}F-THK-5351$ is a PET radiotracer to image the hyperphosphorylated tau fibrillar aggregates in human brain. This protocol describes the optimized radiosynthesis of $^{18}F-THK-5351$ using a commercial GE $TRACERlab^{TM}$ $FX_{FN}$ radiosynthesis module. $^{18}F-THK-5351$ was prepared by nucleophilic [$^{18}F$]fluorination from its protected tosylate precursors, (S)-(2-(2-methylaminopyrid-5-yl)-6-[[2-(tetrahydro-2H-pyran-2-yloxy)-3-tosyloxy]propoxy] quinolone(THK-5352), at $110^{\circ}C$ for 10 min in dimethyl sulfoxide, followed by deprotection with 1 N HCl. The average radiochemical yield of $^{18}F-THK-5351$ was $31.9{\pm}6.7%$(decay-corrected, n = 10), with molar activity of $198.1{\pm}33.9GBq/{\mu}mol$($5.4{\pm}0.9Ci/{\mu}mol$, n = 10). The radiochemical purity was determined to be above 98%. The overall production time including HPLC purification is approximately 70 min. This fully-automated protocol is validated for clinical use.

Characteristics of Atmospheric Aerosol Optical Thickness over the Northeast Asia Using TERRA/MODIS Data during the Year 2000~2005 (동북아시아 지역에서 TERRA/MODIS 위성자료를 이용한 2000~2005년 동안의 대기 에어러솔 광학두께 변화 특성)

  • Lee, Dong Ha;Lee, Kwon Ho;Kim, Jeong Eun;Kim, Young Joon
    • Atmosphere
    • /
    • v.16 no.2
    • /
    • pp.85-96
    • /
    • 2006
  • The six-year (2000~2005) record of aerosol optical thickness (AOT or $\tau$) data from the Moderate Resolution Imaging Spectroradiometer (MODIS) was analyzed over the Northeast Asia. The MODIS AOT standard products (MOD04_L2) over both ocean and land were collected to evaluate the spatial and temporal variability of the atmospheric aerosols over the study region ($32^{\circ}N{\sim}42^{\circ}N$ and $115^{\circ}E{\sim}133^{\circ}E$). The monthly averaged AOT result revealed slight changes(${\pm}0.002{\tau}/month$), which was almost unchangeable, over Korea. In contrast, the large AOT values (> 0.6) and a significant AOT increase (> 0.004 ${\tau}/month$) over East China were observed. For the analysis of spatio-temporal variability of AOT values, study area was divided by six sectors (I: North-East China, II: East China, III: Yellow Sea, IV: Korea Peninsular, V: East Sea, and VI: South Sea and Western part of Japan). The considerable result showed that particularly high AOT contribution was observed over sector I (32.5%) and II (25.5%) where some major urban and industrialized areas and agricultural fields are located and other cases were observed 13.2%, 14.6%, 7.1%, 7.0% over sector III, IV, V, and VI, respectively. In addition, yearly AOT changes based on seasons are observed differently at each sector but increasing trends reveal in summer and fall over all sectors.

Optimized production method of [18F]flortaucipir injection for imaging tau pathology in patients with Alzheimer's disease

  • Kyung Rok Nam;Sang Jin Han;Nam Hun Lee;Min Yong Lee;Youngduk Kim;Kyo Chul Lee;Yong Jin Lee;Young Hoon Ryu;Jae Yong Choi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.2
    • /
    • pp.61-68
    • /
    • 2020
  • Aggregated neurofibrillary tangles (NFTs) are a pathological hallmark in Alzheimer's disease (AD) and many radiopharmaceuticals targeting NFTs have been developed so far. Among these, [18F]flortaucipir (TAUVIDTM) is the first approved radiopharmaceutical in the Food and Drug Administration (FDA) to image tau pathology. In the present study, we describe the optimized radiosynthetic method for the routine production of [18F] flortaucipir using a commercialized automation module (i.e. GE TRACERlabTM FXFN pro). [18F]Flortaucipir was prepared by nucleophilic substitution from its N-tert-butoxycarbonyl protected nitro precursor, tertbutyl 7-(6-nitropyridin-3-yl)-5H-pyrido[4,3-b]indole-5-carboxylate, at 130℃ for 10 min in dimethyl sulfoxide. The mean radiochemical yield was 20 ± 4.3% (decay-corrected, n = 47) with the molar activity of 218 ± 32 GBq/µmol at the end of synthesis. The radiochemical purity was determined to be above 95%. The overall production time including quality control is approximately 100min. The final produced [18F]flortaucipir injection meets the USP criteria for quality control. Thus, this fully automated system is validated for clinical use.

Ginsenoside Rg1 attenuates cerebral ischemia-reperfusion injury due to inhibition of NOX2-mediated calcium homeostasis dysregulation in mice

  • Han, Yuli;Li, Xuewang;Yang, Liu;Zhang, Duoduo;Li, Lan;Dong, Xianan;Li, Yan;Qun, Sen;Li, Weizu
    • Journal of Ginseng Research
    • /
    • v.46 no.4
    • /
    • pp.515-525
    • /
    • 2022
  • Background: The incidence of ischemic cerebrovascular disease is increasing in recent years and has been one of the leading causes of neurological dysfunction and death. Ginsenoside Rg1 has been found to protect against neuronal damage in many neurodegenerative diseases. However, the effect and mechanism by which Rg1 protects against cerebral ischemia-reperfusion injury (CIRI) are not fully understood. Here, we report the neuroprotective effects of Rg1 treatment on CIRI and its possible mechanisms in mice. Methods: A bilateral common carotid artery ligation was used to establish a chronic CIRI model in mice. HT22 cells were treated with Rg1 after OGD/R to study its effect on [Ca2+]i. The open-field test and poleclimbing experiment were used to detect behavioral injury. The laser speckle blood flowmeter was used to measure brain blood flow. The Nissl and H&E staining were used to examine the neuronal damage. The Western blotting was used to examine MAP2, PSD95, Tau, p-Tau, NOX2, PLC, p-PLC, CN, NFAT1, and NLRP1 expression. Calcium imaging was used to test the level of [Ca2+]i. Results: Rg1 treatment significantly improved cerebral blood flow, locomotion, and limb coordination, reduced ROS production, increased MAP2 and PSD95 expression, and decreased p-Tau, NOX2, p-PLC, CN, NFAT1, and NLRP1 expression. Calcium imaging results showed that Rg1 could inhibit calcium overload and resist the imbalance of calcium homeostasis after OGD/R in HT22 cells. Conclusion: Rg1 plays a neuroprotective role in attenuating CIRI by inhibiting oxidative stress, calcium overload, and neuroinflammation.

The Development of Theoretical Model for Relaxation Mechanism of Sup erparamagnetic Nano Particles (초상자성 나노 입자의 자기이완 특성에 관한 이론적 연구)

  • 장용민;황문정
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.39-46
    • /
    • 2003
  • Purpose : To develop a theoretical model for magnetic relaxation behavior of the superparamagnetic nano-particle agent, which demonstrates multi-functionality such as liver- and lymp node-specificity. Based on the developed model, the computer simulation was performed to clarify the relationship between relaxation time and the applied magnetic field strength. Materials and Methods : The ultrasmall superparamagnetic iron oxide (USPIO) was encapsulated with biocompatiable polymer, to develop a relaxation model based on outsphere mechanism, which was resulting from diffusion and/or electron spin fluctuation. In addition, Brillouin function was introduced to describe the full magnetization by considering the fact that the low-field approximation, which was adapted in paramagnetic case, is no longer valid. The developed model describes therefore the T1 and T2 relaxation behavior of superparamagnetic iron oxide both in low-field and in high-field. Based on our model, the computer simulation was performed to test the relaxation behavior of superparamagnetic contrast agent over various magnetic fields using MathCad (MathCad, U.S.A.), a symbolic computation software. Results : For T1 and T2 magnetic relaxation characteristics of ultrasmall superparamagnetic iron oxide, the theoretical model showed that at low field (<1.0 Mhz), $\tau_{S1}(\tau_{S2}$, in case of T2), which is a correlation time in spectral density function, plays a major role. This suggests that realignment of nano-magnetic particles is most important at low magnetic field. On the other hand, at high field, $\tau$, which is another correlation time in spectral density function, plays a major role. Since $\tau$ is closely related to particle size, this suggests that the difference in R1 and R2 over particle sizes, at high field, is resulting not from the realignment of particles but from the particle size itself. Within normal body temperature region, the temperature dependence of T1 and T2 relaxation time showed that there is no change in T1 and T2 relaxation times at high field. Especially, T1 showed less temperature dependence compared to T2. Conclusion : We developed a theoretical model of r magnetic relaxation behavior of ultrasmall superparamagnetic iron oxide (USPIO), which was reported to show clinical multi-functionality by utilizing physical properties of nano-magnetic particle. In addition, based on the developed model, the computer simulation was performed to investigate the relationship between relaxation time of USPIO and the applied magnetic field strength.

  • PDF

Development of Fluorescent Small Molecules for Imaging of Alzheimer's Disease Biomarkers (알츠하이머병의 영상 진단을 위한 형광 프로브의 개발)

  • Min, Changho;Ha, Heonsu;Jeon, Jongho
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Alzheimer's disease (AD), an irreversible degenerative disorder, is associated with accumulation and aggregation of amyloid-β peptides, hyperphosphorylated tau proteins, and high level of metal ions in the brain. Up to date, there is no effective therapeutic agent to stop the progress of the disease and thus early and accurate diagnosis of AD has gained increasing attention in recent years. Among several diagnostic methods, an optical imaging using fluorescent probes is one of the most promising tools to visualize AD biomarkers. In this review, we will introduce fluorescent probes that can be applied to in vivo brain imaging of AD models and also their structure. It is expected that the present review will provide useful information to many scientists in the related research fields.

Transient osteoporosis of the hip with a femoral neck fracture during follow-up: a case report

  • Yusuke Tabata;Shuhei Matsui;Masabumi Miyamoto;Koichiro Omori;Yoichiro Tabata;Tokifumi Majima
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.2
    • /
    • pp.212-217
    • /
    • 2023
  • We report a case of transient osteoporosis of the hip with a femoral neck fracture found during follow-up. A 53-year-old man presented with left hip pain without trauma. The pain did not improve after 2 weeks and he was brought to our hospital by ambulance. Magnetic resonance imaging (MRI) of the left hip joint showed diffuse edema in the bone marrow, which was identified by low signal intensity on T1-weighted images, high signal intensity on T2-weighted images, and increased signal intensity on short tau inversion recovery. This edema extended from the femoral head and neck to the intertrochanteric area. He was diagnosed with transient osteoporosis of the left hip. Rest gradually improved his pain; however, 3 weeks later, his left hip pain worsened without trauma. X-ray, computed tomography, and MRI results of the hip joint demonstrated a left femoral neck fracture, and osteosynthesis was performed. Differential diagnoses included avascular necrosis of the femoral head, infection, complex regional pain syndrome, rheumatoid arthritis, leukemia, and other cancers. Transient osteoporosis of the hip generally has a good prognosis with spontaneous remission within a few months to 1 year. However, a sufficient length of follow-up from condition onset to full recovery is necessary to avoid all probable complications such as fractures.

Alzheimer Dementia and Microvascular Pathology: Blood-Brain Barrier Permeability Imaging (알츠하이머 치매와 미세뇌혈관병리: 혈액뇌장벽 투과도 영상)

  • Won-Jin Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.488-500
    • /
    • 2020
  • Accumulating evidence suggests that Alzheimer's disease (AD) is not only caused by accumulation of abnormal proteins, including amyloid and tau, but is also closely associated with abnormalities in the microvascular environment including the blood-brain barrier (BBB), both of which lead to neuroinflammation and neurodegeneration. Application of in vivo magnetic resonance imaging (MRI) has recently increased to assess BBB permeability in AD and related diseases. Here, we provide a narrative review of BBB permeability-related pathology in Alzheimer dementia and recent MRI research on BBB permeability changes in AD and related diseases. Furthermore, we briefly introduce the measurement of BBB permeability using MRI and its methodological issues.

Correlation between Magnetic Resonance Image Signal Changes and Electromyographic Findings after Sciatic Nerve Transection in the Rat (백서의 좌골신경 절단 후 비복근의 자기공명영상 신호강도 변화와 근전도 소견의 관계)

  • Lee, Joo Hwan;Lee, Jang Chul;Kim, Dong Won;Park, Ki Young;Lee, Sung Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.101-107
    • /
    • 2000
  • Objectives : The evaluation of peripheral nerve injuries has traditionally relied on a clinical history, physical examination, and electrodiagnostic studies. The purpose of the present study was to examine serial magnetic resonance image(MRI) changes following acute muscle denervation under experimental conditions and to identify potential advantages and disadvantages of this use of MRI. Methods : An experimental transection of right sciatic nerve on Spargue-Dawley rats was performed. MRI was performed with T1-weighted spin-echo and STIR sequences. The imaging findings were compared with EMG in order to determine its sensitivity relative to this standard procedure. A simultaneous histopathological study provided information about the morphological basis of the imaging findings. Signal intensities were expressed as a ratio of abnormal to normal. Results : The signal intensity ratio of muscles with the STIR sequence was increased significantly at 2 weeks after sciatic nerve transection(p<0.05), although definite signal change was seen as early as 4 days postdenervation in one. EMG revealed significant denervation potential from 3 days after nerve transection. Diffuse cell atrophy was revealed hostologically at 2 weeks after transection, which was at the same time of significant signal change in MRI. Conclusion : MRI signal changes in denervated muscles secondary to nerve injury correlate with the degree of muscle atrophy on histologic examination. In addition to EMG, MRI can document the course of muscle atrophy and mesenchymal abnormalities in denervation. These results indicate that MRI can play a complementary role in the evaluation of patients with denervation.

  • PDF