• Title/Summary/Keyword: Tarsal

Search Result 125, Processing Time 0.018 seconds

A New Record of Tarsonemid Mite, Stenotarsonemus spinki (Acari, Tarsonemidae) and Its Damage on Rice in Korea (한국 미기록 벼먼지응애, Steneotarsonemus spinki와 그 피해)

  • 조명래;김덕수;임대준;나승용;임명순
    • Korean journal of applied entomology
    • /
    • v.38 no.2
    • /
    • pp.157-164
    • /
    • 1999
  • A tarsonemid mite. Stet~rotc~r.sot~rrrs~puin.sk i Smiley 1967. is an important rice pest in major rice producing countries of Thailand. Philippine. China, and Taiwan. S. spinki was found first time in Korea from rice grown in environment controlled greenhouse. Rice fed by the mite showed damage symptoms of deformed panicles and inflorescence, lesions on the inner surface of leaf sheath, and browning of rice hulls. Females of S. .spi~lkwi as 263.0 pni (246.5-284.6f 12.2) in body length and 92.4 pm (79.5- 104.9 t 7.6) in body width. Body was elongate and broadest in region of hysterosoma. Body color was pale brown. Legs were robust except for the legs IV which were typical tarsonemid female legs terminating in a whiplike seta two times the length of the leg. Male of S. spir~kiw as 196.5 pm ( 176.5-222.8 + 15.8) in body length and 109.3 ym (98.6- 1 17.7 + 6.4) in body width. Anterior ends of apodemes 111 were extended further than apodemes IV. Femur IV had large inner median lateral flange. and inner anterior and outer median setae were short about equal length. Tarsal claw was stout and curved ventrally.

  • PDF

Correction of High Fold without Skin Excision (피부 제거 없이 시행한 높은 쌍꺼풀의 교정)

  • Oh, Heung Chan;Yoon, Dong Ju;Kang, Cheol Uk;Choi, Chi Won;Choi, Soo Jong;Bae, Yong Chan
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.649-653
    • /
    • 2009
  • Purpose: Double - eyelid operation is one of the most common cosmetic operations among Korean patients. In such operations, however, the complexity of and individual differences in the patients' anatomical structures may cause various complications, such as asymmetry, retraction of the eyelid, and the occurrence of a high fold. A high fold occurs frequently, and its correction is not very simple. Many methods have been developed to correct it, and among these, the operation involving the excision of the skin between the previous double - eyelid line and the new double - eyelid line is usually selected by plastic surgeons. In many cases, however, patients have insufficient eyelid skins for this operation. In this study, the authors introduce an operation procedure for high - fold correction that does not involve skin excision Methods: From June 2005 to June 2009, 246 cases were treated with this procedure. After the incision of the new double - eyelid line, dissection was done between the previous scar tissue and the levator aponeurosis. Then the orbital septum, orbital fat or the retro - orbicularis oculi fat was slid down and sutured with a tarsal plate. Such sutures were repeated at four to five points, including the lateral and medial limbus, to prevent the reattachment of the previous scar and to create a new double - eyelid line at the end of the orbital septum. Results: Most of the high - fold patients were satisfied with the procedure described above. Their previous scar was hidden under the new double - eyelid line after the operation. In the six cases, the scar was visible in the patients who had a very high and deep inner line. As such, scar revision was undertaken three months after the operation. It is known that scar revision is also required after an operation involving skin excision in the case of a very high inner - eyelid line. Conclusion: This method is an appropriative procedure for high - fold correction for patients who have insufficient upper - eyelid skin.

Determination of Pelvic Limb Alignment in Small-breed Dogs (소형견종의 후지정렬 측정)

  • Kim, Jooho;Heo, SuYoung;Na, Jiyoung;Kim, Namsoo;Lee, Kichang;Jeong, Seongmok;Lee, HaeBeom
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.481-485
    • /
    • 2015
  • The present study determined the normal reference ranges for overall pelvic limb alignment of small-breed dogs. For this purpose, 60 cadaveric canine pelvic limbs from normal small-breed dogs (Maltese, Poodle, Shih Tzu, Yorkshire Terrier). A frontal full-limb radiograph of each pelvic limb was obtained, and mechanical tibiofemoral angle (mTFA), mechanical metatarsotibial angle (mMTTA), mechanical axis-femur angle (MAFA), and mechanical axis-metatarsus angle (MAMTA) were measured from each radiograph, along with mechanical deviation of the stifle (SMAD) and tarsal joints (TMAD). The 95% CI for radiographic values of all pelvic limbs were mTFA, 5.7-7.4; mMTTA, $-2.2--0.8^{\circ}$; MAFA, $3.5-4.5^{\circ}$; MAMTA, 1.0-2.0; SMAD, 2.1-2.7%; TMAD, 0.5-1.0%. There values varied among the breeds, except for mTFA. The reference ranges can be used for diagnosing pelvic limb deformities in small-breed dogs and for planning corrective osteotomies.

A Study on the Usefulness of the New Foot Oblique Projection (새로운 발 사방향 검사법의 유용성에 관한 연구)

  • Kim, Min-Suk;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.443-449
    • /
    • 2021
  • In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28~9.56 mm. The qualitative evaluation showed a reliability of 0.95~1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°~60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.

Morphometric Characterization of Newly Defined Subspecies Apis cerana koreana (Hymenoptera: Apidae) in the Republic of Korea (국내 토종벌(Apis cerana koreana) 아종의 형태적 특성 분석)

  • Olga, Frunze;Jung-Eun, Kim;Dongwon, Kim;Eun-Jin, Kang;Kyungmun, Kim;Bo-Sun, Park;Yong-Soo, Choi
    • Korean journal of applied entomology
    • /
    • v.61 no.3
    • /
    • pp.399-408
    • /
    • 2022
  • There has been much debate on the morphometric divergence between the recently identified Apis cerana koreana and Apis cerana honey bees. The aim of this study was to obtain phenotypic information that can be used to compare A. c. koreana data with other A. cerana subspecies data from open resources and determine breeding results on the basis of morphometric traits. To differentiate A. c. koreana, we investigated 22 classic morphological characteristics; royal jelly secretion; and the weight of workers, queens, and drones of A. c. koreana bred in Korea. To define the selection results, we used the geometric morphometric method. The artificially selected A. c. koreana secreted significantly more royal jelly (1.18 times) than the naturally selected A. c. koreana, which positively influenced the health of the colonies. These honey bees were identified more clearly with the geometric morphometric method than with the classic morphometric method, which is traditionally used to determine the subspecies. Large trends were noted for A. c. koreana on the basis of our results and literature from the 1980s regarding A. cerana sizes in Korea (tarsal index, length of forewing, and cubital index were measured). The cluster analysis revealed the proximity of A. c. koreana, A. cerana in China, and A. c. indica on the basis of eight classic characters, which, perhaps, relay the origin of the honey bees. The results of this study defined the morphometric responses of A. c. koreana honey bees to geographic isolation, climate change, and selection, which are important to identify, protect, and preserve honey bee stock in Korea.