• Title/Summary/Keyword: Targeting

Search Result 5,130, Processing Time 0.033 seconds

The Personalized(targing) Service of HD Broadcasting and 3D Mesh Contents using RMPI (Personalized(targeting) 맞춤형 방송 및 3차원 Mesh Data 컨텐츠 서비스)

  • Jung, Joing-Jin;Lim, Tae-Bum;Lee, Suk-Pil
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.304-306
    • /
    • 2004
  • With the developing of current multimedia broadcasting, user will be provided for lots of various content through the various channel and media. Content provider and consumer want the various service using content with the better quality which is fit to users' preference. For transmitting this content in the limited transmission channel capacity, it needs to transmit the highly compressed content. The content of 3D mesh model-based on MPEG-4 enables the various content service that provides the lower size and the resonable quality, and Personalize(Targeting) service just provide the contents that user more wants and likes. This paper presents the study on the targeting service using compression of 3D mesh model-based on MPEG-4 and the adaptation of Embedded Graphic application program using it.

  • PDF

GROUND TRACK MAINTENANCE MANEUVER SIMULATIONS FOR THE KOMPSAT SPACECRAFT

  • Lee, Byoung-Sun;Lee, Jeong-Sook
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.1
    • /
    • pp.197-208
    • /
    • 1998
  • Ground track manintenance maneuver simulations for the KOMPSAT spacecraft are performed for three and half years. Both longitude targeting and time targeting strate-gies are applied for in-plane maneuvers. The nominal longitude bands of maneuvers for $\pm5km$ and $\pm10km$ are applied for the longitude targeting and the 21-day maneuver time duration is used for the time targeting. Daily solar flux values for the simulation period are derived from the previous solar cycle values. Atmospheric drag formula for the KOMPSAT orbit altitude is derived from Jacchia model using polynomial and sinusoidal curve fitting. Total required delta velocity and proper time between successive maneuvers are estimated during ground track maintenance maneuver simulations.

  • PDF

사이버나이프의 Targeting 에러의 평가

  • Jang, Ji-Seon;Gang, Yeong-Nam;Lee, Tae-Gyu;Choe, Byeong-Ok;Lee, Gyeong-Jin;Choe, Il-Bong;Kim, Mun-Chan;Gwon, Su-Il
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.87-88
    • /
    • 2005
  • 사이버나이프를 이용한 두경부와 체부 등의 정위방사선수술에서는 목표점의 식별 및 위치 추적에 대하여 높은 정확성을 요구한다. 본 연구에서는 사이버나이프의 targeting의 정확성을 평가하고자 한다. 사이버나이프의 targeting의 정확성을 평가하기 위하여 두상 팬텀을 사용하였다. 환자 치료시와 동일한 CT 영상 프로토콜로 두상 팬텀의 영상을 얻어 치료계획을 세웠다. 팬텀에 radiochromic 필름을 삽입한 뒤 수립된 치료계획에 맞춰 팬텀에 방사선을 조사하였다. 방사선 조사시 위치 추적은 skull과 fiducial 추적의 두 가지 방법을 사용하였다. 방사선에 조사된 radiochromic 필름을 분석하여 정확성을 평가하였다. 본 연구를 통하여 실시간 영상유도 기술을 사용하는 사이버나이프는 약 1 mm의 targeting 에러를 보였다.

  • PDF

Synthesis and Characterization of HPMC Derivatives as Novel Duodenum-Specific Coating Agents

  • Huang Yuan;Zheng ling Ii;Liu Jun;Zhang Zhi rong
    • Archives of Pharmacal Research
    • /
    • v.28 no.3
    • /
    • pp.364-369
    • /
    • 2005
  • HPMC (Hydroxypropyl methylcellulose) was chemically modified, using maleic anhydrides, to obtain pH-sensitive HPMCAM (Hydroxypropyl methylcellulose acetate maleate) polymers for use as novel duodenum-specific coating agents. The pharmaceutical properties of HPMCAM, such as film forming, acid values, pH-sensitive values, water vapor permeability, tensile strength and Tg, were investigated, and found to show good film forming properties. The pH­sensitive values were 3.0 to 3.7. In vitro results demonstrate that HPMCAM could completely suppress drug release within 2h in a simulated gastric fluid (pH 1.2) and rapidly release the drug in a simulated pathological duodenal fluid (pH 3.4). These results indicate that HPMCAM might be a useful material for a duodenum-specific drug delivery system.

CR 2945-Conjugated Liposomes for Targeting of Human Pancreatic Cancer Cells

  • Yoon, Na-Young;Kim, Jin-Seok
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.6
    • /
    • pp.459-463
    • /
    • 2004
  • CR 2945, a $gastrin/CCK_B$ receptor antagonist, was conjugated to liposome and tested for the targeting of pancreatic cancer cells in vitro. Successful conjugation was confirmed by FTIR and NMR. The size of CR 2945-conjugated liposome was about 500 nm in diameter, with the zeta-potential being -16.5 mV. In vitro anti-cancer activity of this formulation with or without gemcitabine encapsulated was tested on human pancreatic cancer cells, PANC-1. The growth inhibitory effect of gemcitabine-encapsulating CR 2945-conjugated liposome was found to be 10-fold more potent than that of gemcitabine-encapsulating non-conjugated liposome, suggesting that CR 2945 could be used as a potential cancer targeting moiety by conjugating into liposome.

Research Ethics on the Psychological and Clinical Study Targeting Children and Adolescents

  • Seong-Gon KIM
    • Journal of Research and Publication Ethics
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • Purpose: Psychological and clinical studies targeting children and adolescents have become increasingly important in recent years as researchers strive to understand better the psychological and physiological development of children and teens. The purpose of the study is to explore significant research ethics on the psychological and clinical study targeting children and adolescents. In addition to these ethical considerations, international and national codes of ethics and regulatory bodies guide ethical research practices with children and adolescents. Research design, data, and methodology: The present study used the qualitative textual collection through investigating the past and current literature review. Numerous prior studies have conducted this research design to obtain the right prior studies. Results: Previous Research has indicated there are four research ethics on the psychological and clinical study targeting children and adolescents. (1) Respect for autonomy, (2) Respect for privacy and confidentiality, (3) Respect for vulnerability, (4). Respect for beneficence. Conclusions: In conclusion, research ethics are essential for protecting children and adolescents when conducting psychological and clinical studies. In the future, research should focus on developing innovative methods to ensure the safety of children and adolescents while still allowing them to participate in research.

Research Progress of CXCR4-Targeting Radioligands for Oncologic Imaging

  • Yanzhi Wang;Feng Gao
    • Korean Journal of Radiology
    • /
    • v.24 no.9
    • /
    • pp.871-889
    • /
    • 2023
  • C-X-C motif chemokine receptor 4 (CXCR4) plays a key role in various physiological functions, such as immune processes and disease development, and can influence angiogenesis, proliferation, and distant metastasis in tumors. Recently, several radioligands, including peptides, small molecules, and nanoclusters, have been developed to target CXCR4 for diagnostic purposes, thereby providing new diagnostic strategies based on CXCR4. Herein, we focus on the recent research progress of CXCR4-targeting radioligands for tumor diagnosis. We discuss their application in the diagnosis of hematological tumors, such as lymphomas, multiple myelomas, chronic lymphocytic leukemias, and myeloproliferative tumors, as well as nonhematological tumors, including tumors of the esophagus, breast, and central nervous system. Additionally, we explored the theranostic applications of CXCR4-targeting radioligands in tumors. Targeting CXCR4 using nuclear medicine shows promise as a method for tumor diagnosis, and further research is warranted to enhance its clinical applicability.

Trends in Protein Engineering for Gene Targeting: Homing Endonucleases and Zinc Finger Nucleases (유전자 표적화를 위한 단백질공학 연구동향: Homing Endonucleases and Zinc Finger Nucleases)

  • Cheong, Dea-Eun;Kim, Geun-Joong
    • KSBB Journal
    • /
    • v.25 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • Monogenic diseases are resulted from modifications in a single gene of human cells. Because their treatment with pharmacological medicine have a temporary effect, continuous nursing care and retreatment are required. Gene therapy, gene targeting and induced pluripotent stem cell (iPSC) are considered permanent treatment methods of them. In gene therapy, however, retroviral vectors that have potential toxicity caused by random insertion of harmful virus are used as vehicles for transferring genetic materials. On the other hand, gene targeting could replace and remove the modified gene though homologous recombination (HR) induced by site-specific endonucleases. This short review provides a brief overview on the recently tailored endonucleses with high selectivity for HR.

Gallic acid-mitochondria targeting sequence-H3R9 induces mitochondria-targeted cytoprotection

  • Bae, Yoonhee;Kim, Goo-Young;Jessa, Flores;Ko, Kyung Soo;Han, Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.26 no.1
    • /
    • pp.15-24
    • /
    • 2022
  • The development of selective targeting of drug molecules towards the mitochondria is an important issue related to therapy efficacy. In this study, we report that gallic acid (GA)-mitochondria targeting sequence (MTS)-H3R9 exhibits a dual role as a mitochondria-targeting vehicle with antioxidant activity for disease therapy. In viability assays, GA-MTS-H3R9 showed a better rescue action compared to that of MTS-H3R9. GA-MTS-H3R9 dramatically exhibited cell penetration and intercellular uptake compared to MTS and fit escape from lysosome release to the cytosol. We demonstrated the useful targeting of GA-MTS-H3R9 towards mitochondria in AC16 cells. Also, we observed that the antioxidant properties of mitochondrial-accrued GA-MTS-H3R9 alleviated cell damage by reactive oxygen species production and disrupted mitochondrial membrane potential. GA-MTS-H3R9 showed a very increased cytoprotective effect against anticancer activity compared to that of MTS-H3R9. We showed that GA-MTS-H3R9 can act as a vehicle for mitochondria-targeting and as a reagent for therapeutic applications intended for cardiovascular disease treatment.

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF