• Title/Summary/Keyword: Target spot

Search Result 163, Processing Time 0.031 seconds

Compact Anode Design with the Heat Capacity Performance in Rotating Anode X-ray Tube for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2015
  • We studied the compact anode design to develop 100 kW rotating anode X-ray tube with large focal spot 1.2 mm, small focal spot 0.6 mm and tube voltage 150 kV for large hospital digital radiography using computer thermal simulation. The larger thermal radiation effect in a high vacuum can reduce the temperature of anode so the method to increase the surface area of anode is investigated. The anode has the multi-tier shape at the back side of TZM body of anode and also bigger diameter of anode. The number of multi-tiers was varied from 6 to 15 and the diameter of anode was also varied from ${\Phi}74$ to ${\Phi}82$. From ANSYS transient thermal simulation result, we could obtain $1056.4^{\circ}C$ anode maximum temperature when applying 100 kW input power at 0.1 second on target focal track which is less than $1091^{\circ}C$ of the conventional 75 kW X-ray tube with reduced anode weight by 15.5% than the conventional anode. The compact anode of reduced anode weight is able to improve the unwanted noise when the rotor is rotating at high-speed and also reduce the rotational torque which the cost effective stator-coil is possible. It is believed that the anode with 15 ea multi-tiers using ${\Phi}82$ can satisfy with the specification of the anode heat capacity. From the results of this paper, it has been confirmed that the proposed compact anode can be used as the anode of 100 kW rotating anode X-ray tube for digital radiography.

CNT-BASED FIELD EMISSION X-RAY SOURCE

  • Kim, Hyun Suk;Lee, Choong Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.433-433
    • /
    • 2016
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission. CNT yarns have demonstrated its potential as excellent field emitters. It was demonstrated that a small focal spot size was achieved by manipulating some electrical parameters, such as applied bias voltage at the mesh gate, and electrostatic focal lenses, geometrical parameters, such as axial distances of the anode, and the electrostatic focal lens from the cathode assembly, and the dimension of the opening of the electrostatic lens. Electrical-optics software was used to systematically investigate the behavior of the electron beam trajectory when the aforementioned variables were manipulated. The results of the experiment agree with the theoretical simulation results. Each variable has an individual effect on the electron beam focal spot size impinging on the target anode. An optimum condition of the parameters was obtained producing good quality of X-ray images. Also, MWCNT yarn was investigated for field emission characteristics and its contribution in the X-ray generation. The dry spinning method was used to fabricate MWCNT yarn from super MWCNTs, which was fabricated by MW-PECVD. The MWCNT yarn has a significant field emission capability in both diode and the triode X-ray generation structure compared to a MWCNT. The low-voltage-field emission of the MWCNT yarn can be attributed to the field enhancing effect of the yarn due to its shape and the contribution of the high-aspect-ratio nanotubes that protrude from the sides of the yarn. Observations of the use of filters on the development of X-ray images were also demonstrated. The amount of exposure time of the samples to the X-ray was also manipulated. The MWCNT yarn can be a good candidate for use in the low voltage field emission application of X-ray imaging.

  • PDF

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

Reverse Design of F-Theta Lens for Compact Laser Scanner (소형 2차원 레이저 스캐너용 F-theta 렌즈 역설계)

  • Choi, Hae Woon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.3
    • /
    • pp.213-218
    • /
    • 2017
  • In this study, a reverse design of the F-theta lens was proposed for a 2D scanner in remote welding applications. The curvature and distance of the lens were set as variables, and the focal length of the lens was set as the marginal ray height. The ZEMAX commercial software was used to perform a simulation with unlimited iterations for the optimization process. The target value was optimized using the internal Merit function with the weight factors of focal length and spot diameter. The number of lenses was four, and the focal length obtained from the results was 135mm that is slightly less than that of the commercial lens, which is set with a focal length of 185 mm. The calculated spot diameters are $1.3{\mu}m$, $6.2{\mu}m$, and $16.1{\mu}m$ for $0^{\circ}$, $12.5^{\circ}$ and $23^{\circ}$ of incident laser beam, respectively. It is expected that an optimized lens design is possible by performing the reverse design of a lens by the ray tracing method.

Identifying the potential target substance of physical developer (PD) for reagent reliability test and a study on storage period of TWEEN® 20 based PD working solution (Physical Developer(PD)의 신뢰성 테스트(reagent reliability test)를 위한 타겟물질 탐색과 TWEEN® 20 기반 PD 작업용액의 보관기간에 관한 연구)

  • Soo-Jeong Ahn;Ye-jin Lee;Je-Seol Yu
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.113-120
    • /
    • 2023
  • Physical developer (PD) is an effective technique that can develop fingerprints even on wet or very old paper. However, it has not been known which substance reacts with PD. Also, the timing of optimization according to the storage period of the PD working solution has not been known. The present research has done a spot test with 7 eccrine components and 5 sebaceous components that known as fingerprint components and figured out the mixture of palmitic acid and lysine gave the strongest positive reaction. Also, paper treated with PD was treated in 1,2-indanedione/zinc (1,2-IND/Zn) working solution and showed lysine was not dissolved in water. To find out the timing of optimization according to the storage period of the TWEEN® 20 based PD working solution, the mixture of palmitic acid and lysine was used for the target of reagent reliability test. As the result, working solution of 14 days storage period showed better result than other working solutions.

Profiling of Metabolites and Proteins from Eschscholtzia californica induced by Yeast Extract (Yeast Extract로 처리된 Eschscholtzia californica의 Metabolite와 Protein의 변화)

  • Cho Hwa-Young;Park Jeong-Jin;Yoon Sung-Yong;Part Jong Moon
    • KSBB Journal
    • /
    • v.20 no.4
    • /
    • pp.285-290
    • /
    • 2005
  • Benzophenanthridine alkaloids - sanguinarine, chelirubine, macarpine, and chelerythrine are produced from Eschscholtzia californica (Californica Poppy, used as a sedative by Native Americans) and most of them are derived from dihydrosanguinarine. The properties of sanguinarine are the basis of its antimicrobial activity and its use in chemosurgery and skin cancer excision. For overproduction of sanguinarine from E. californica, yeast extract was used as elicitor and the elicited cell's metabolites were checked. Sanguinarine production was increased intracelluarly about 8 times in the cell and 5 times extracelluarly. We have peformed proteomic analysis of proteins sequentially extracted from E. califormica suspended cells which were cultured with elicitor, an increase of spot intensity was seen at 24 hours following elicitation. These proteins were separated by two-dimensional electrophoresis (2-DE). We found several spots that were expected to be related to benzophenanthridine alkaloids production by comparing the production profiles of metabolites such as sanguinarine. These results demonstrate the use of metabolite analysis as a tool for detecting target proteins related to metabolites production pathway.

DEEP-South: Performance of Moving Object Detection Program in Different Observation Modes

  • Oh, Young-Seok;Bae, Yeong-Ho;Kim, Myung-Jin;Roh, Dong-Goo;Jin, Ho;Moon, Hong-Kyu;Park, Jintae;Lee, Hee-Jae;Yim, Hong-Suh;Choi, Young-Jun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.48.3-49
    • /
    • 2016
  • We have five different types of observation modes with regard to the Deep Ecliptic Patrol of the Southern Sky (DEEP-South); Opposition Census (OC) for targeted photometry, Sweet Spot Survey (S1) for discovery and orbit characterization of Atens and Atiras, Ecliptic Survey (S2) for asteroid family studies and comet census, NEOWISE follow-up (NW) for near simultaneous albedo measurements in the visible bands, and Target of Opportunity (TO) observation for follow-up either for unpredictable events or targets of special interests. Different exposures with such different modes result in a wide range of background noise level, the number of background stars and the mover's projected speed in each image. The Moving Object Detection Program (MODP) utilizes multiple mosaic images being taken for the same target fields at different epochs at the three KMTNet sites. MODP employs existing software packages such as SExtractor (Source-Extractor) and SCAMP (Software for Calibrating Astrometry and Photometry); SExtractor generates object catalogs, while SCAMP conducts precision astrometric calibration, then MODP determines if a point source is moving. This package creates animated stamp images for visual inspection with MPC reports, the latter for checking whether an object is known or unknown. We evaluate the astrometric accuracy and efficiency of MODP using the year one dataset obtained from DEEP-South operations.

  • PDF

Growth of ZnTe Thin Films by Oxygen-plasma Assisted Pulsed Laser Deposition

  • Pak, Sang-Woo;Suh, Joo-Young;Lee, Dong-Uk;Kim, Eun-Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.185-185
    • /
    • 2011
  • ZnTe semiconductor is very attractive materials for optoelectronic devices in the visible green spectral region because of it has direct bandgap of 2.26 eV. The prototypes of ZnTe light emitting diodes (LEDs) have been reported [1], showing that their green emission peak closely matches the most sensitive region of the human eye. Another application to photovoltaics proved that ZnTe is useful for the production of high-efficiency multi-junction solar cells [2,3]. By using the pulse laser deposition system, ZnTe thin films were deposited on ZnO thin layer, which is grown on (0001) Al2O3substrates. To produce the plasma plume from an ablated ZnO and ZnTe target, a pulsed (10 Hz) YGA:Nd laser with energy density of 95 mJ/$cm^2$ and wavelength of 266 nm by a nonlinear fourth harmonic generator was used. The laser spot focused on the surface of the ZnO and ZnTe target by using an optical lens was approximately 1 mm2. The base pressure of the chamber was kept at a pressure around $10^{-6}$ Torr by using a turbo molecular pump. The oxygen gas flow was controlled around 3 sccm by using a mass flow controller system. During the ZnTe deposition, the substrate temperature was $400^{\circ}C$ and the ambient gas pressure was $10^{-2}$ Torr. The structural properties of the samples were analyzed by XRD measurement. The optical properties were investigated by using the photoluminescence spectra obtained with a 325 nm wavelength He-Cd laser. The film surface and carrier concentration were analyzed by an atomic force microscope and Hall measurement system.

  • PDF

Profit Margin Hedging Strategy in Crude Oil Purchasing (이윤율헤징을 이용한 원유 구매 전략)

  • Yang, Ji Hye;Kim, Hyun Seok
    • Environmental and Resource Economics Review
    • /
    • v.26 no.4
    • /
    • pp.499-517
    • /
    • 2017
  • The purpose of this article is to show profit margin hedging can be an optimal strategy in crude oil purchasing. This study theoretically analyzes profit margin hedging strategy is optimal in crude oil purchasing using expected target utility function and conducts simulations to show if the profit margin hedging is profitable. In addition, this study tests existence of mean reversion of crude oil futures prices to confirm the theory that profit margin hedging is more profitable than other strategies, such as always hedging or buying at expiration with spot price, if futures prices are mean reverting. The simulation results show that the expected utility of profit margin hedging higher than other strategies. Although we cannot find any evidence that crude oil futures prices follow mean reverting process, we can conclude that profit margin hedging can be optimal strategy in crude oil purchasing based on theoretical proof and simulation results.