• Title/Summary/Keyword: Target level of safety

Search Result 299, Processing Time 0.038 seconds

Analysis of Human Casualties on the Ground in Urban Area due to UAM Crash (UAM 추락 시 인구 밀접 지역 지상 인명피해 분석)

  • Kim, Youn-sil;Choi, In-ho
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.5
    • /
    • pp.281-288
    • /
    • 2022
  • This study quantitatively analyzed the human casualties that can occur when a multicopter-type Urban Air Mobility (UAM) with a weight of about 1 ton and a speed of about 100 km/h falls in an urban area. Based on the population density and building database in Seoul, the population exposed to collisions in the event of a UAM crash was derived. Through the ballistic descent model, the accident impact radius of the UAM fall was calculated. In addition, the change in human casualties on the ground was analyzed when the accident impact radius increased. Finally, the ground risk map was created for Seoul, and it was confirmed that about 1 to 10 people could be injured when a UAM crash.

Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections With Intermediate Moment Frame Details (중간모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가)

  • Kim, Seon Hoon;Cho, Jong;Oh, Hyo Keun;Choi, Seok Dong;Yeo, Un Yong;Lee, Deuck Hang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.129-137
    • /
    • 2023
  • This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.

Analytical Study for Seismic Capacity Enhancement for Non-structural Elements in Power Plants (발전플랜트 시설 내부 비구조요소의 내진 안전성 향상을 위한 해석적 연구)

  • Bang, Jin Soo;Kwon, Yangsu;Yim, Hong Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • In the case of power plant facilities, seismic stability of non-structural elements is important. In particular, Cabinet structures to which electrical equipment is attached, should have functional safety against earthquakes. Therefore, in this study the dynamic characteristics of non-structural elements inside existing power plant buildings were identified and the response level generated during dynamic behavior was analyzed. In addition, The steel plate dampers were adopted and adjusted to suit the size of the target equipment. In order to derive the optimal seismic reinforcement, the variables according to the attachment location were set and the responses were analyzed by the seismic movement input before and after reinforcement.

Evaluation of Service Life in RC Column under Chloride Attack through Field Investigation: Deterministic and Probabilistic Approaches (염해 실태조사를 통한 철근 콘크리트 교각의 내구수명 평가 - 결정론적 및 확률론적 해석방법)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.67-74
    • /
    • 2015
  • RC (Reinforced Concrete) structures are considered as cost-benefit and durable however performances of structural safety and durability are degraded due to steel corrosion. Service life in RC structure is differently evaluated due to different local environmental conditions even if it is exposed to the same chloride attack. In the paper, 25 concrete cores from field investigation are obtained from 4 RC columns with duration of 3.5~4.5 years exposed to sea water. Through total chloride content measurement, surface chloride contents and apparent diffusion coefficients are evaluated. Service life of the target structure is estimated through deterministic method based on Fick's $2^{nd}$ Law and probabilistic method based on durability failure probability, respectively. Probability method is evaluated to be more conservative and relatively decreased service life is evaluated in tidal zone and splash zone over 40.0 m. Chloride penetration behavior with coring location from sea level and the present limitations of durability design method are investigated in the paper.

Effects of Glufosinate-Ammonium to Earthworms, Soil Microorganisms and Crops (제초제 glufosinate-ammonium의 지렁이 및 토양 미생물과 작물에 미치는 영향)

  • Kim, Yong-Seog;Jeon, Yong-Bae;Choi, Hae-Jin;Kim, Song-Mun;Kim, Sung-Min
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.2
    • /
    • pp.76-83
    • /
    • 2006
  • In order to investigate the impacts of non-selective herbicide, glufosinate-ammonium (ammonium 4-[hydroxy(methyl)phosphinoyl] -DL-homoalaninate, GLA) to the non-target organisms, earthworm was exposed to GLA in the field soil for a month, and microbial populations in the soil were investigated after application of GLA. Simultaneously, the residues of GLA and its metabolite, 3-MPP were analyzed in the same soil. Meanwhile, to elucidate the influence of GLA to the growth of non-target crops incase of inter-furrow application, the amounts of carotenoid, chlorophyll, amino acid, proteins and sugars in the leaves of potato and chinese cabbage grown in the same field were investigated. In result, the dead earthworm was not observed during the test period, and the increasing rates of bodyweight were $9.410{\sim}11.603%$ in GLA-treated plots and 5.645% in GLA-untreated plots. The populations of fungi, bacteria and actinomycetes in the GLA-treated soils were $6.2{\times}10^4$, $1.5{\times}10^6$ and $5.7{\times}10^4$, respectively. They maintained relatively similar levels to the control which were $3.7{\times}10^4$, $3.7{\times}10^5$ and $3.7{\times}10^4$, respectively. In residue analysis, the limit of detection of GLA was 0.02 mg $kg^{-1}$, that of 3-MPP was the same level, and the half-life of GLA was 15 days in sandy clay loam soil. This result indicates that GLA was degraded very quickly in field soil. On the other hand, the amounts of physiological, biochemical components such as carotenoid, amino acid, chlorophyll, protein and sugar were ranged from 90.0 to 104.3% in potato and from 99.0 to 112.7% in chinese cabbage. Comparing with hand-weeded plots, it is indicated that GLA had not affected to the growth of non-target crops when applied at inter-furrow in crops-growing field.

Seismic Performance Evaluation and a Comparative Study on the Design Wind and Earthquake Loads for Power Transmission Towers (송전철탑의 내진성능평가 및 설계 풍하중과 지진하중의 비교 연구)

  • Hwang, Kyeong-min;Chun, Nak-hyun;Jang, Jung-bum;Yun, Kwan-hee;Kim, Tae-kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.2
    • /
    • pp.75-81
    • /
    • 2019
  • In this study 24 power transmission towers were selected by considering various variables such as power transmission capacity, height and structural type to evaluate their seismic performance using the standard design response spectrum recently announced by the government. In addition, the stresses and sectional forces generated by the current design wind loads and revised seismic ones were compared to review the effects on the design of power transmission towers when the government-required seismic standards were raised. The results of seismic performance evaluation for the target power transmission towers showed that they had seismic capacity of 0.31~0.91g, and that they met the level of the earthquake-resistant special grade, which is the 2,400-year earthquake return periods and secured seismic safety. Further, the sectional forces caused by earthquakes in the towers were 33~82.5% of the ones due to wind loads, and it was also confirmed that the design wind loads were more dominant than design earthquake ones under the elevated seismic standards.

A Study on Analysis of Damaged Facilities in Rural Area by Storm and Flood Hazard (풍수해에 의한 농촌지역 피해시설 현황 분석)

  • Lim, Chang-Su;Oh, Yun-Kyung;Lee, Seung Chul;Kim, Eun-Ja;Choi, Jin-Ah
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.2
    • /
    • pp.19-29
    • /
    • 2016
  • Disasters that occur most frequently in rural areas are drought, flood, damages from wind and cold weather. Among these, damages from storm and flood and drought are the main disasters and recently, these are occurring on a large scale due to unusual weather conditions. Under such circumstances, projects and researches on disasters in rural areas are under way but they are mostly targeting one area or making approaches focusing on repair facilities, maintenance project of facilities in small streams, and disaster management, so there have not been enough studies on the current status of overall damaged facilities in the rural areas. Against this backdrop, through the analysis of the current status of damaged facilities due to storm and flood in rural areas, this study aims to provide base data for policies needed for disaster recovery planning and maintenance work of rural areas. For the analysis of damaged facilities due to storm and flood in rural areas, using the annual report on disasters issued by Ministry of Public Safety and Security and based on the occurrence rate of estimated damage in each city and district for the past 10 years(2004~2013), 8 areas with the highest number of occurrence and cost of damage were found from each province and target areas were selected. Then, regarding the selected target areas, the General Plan for Reducing Damages from Storm and Flood, which is the report on top-level plan for preventing disasters, was secured and the current status of damaged facilities were analyzed. After organizing the analysis of current status, the tendency of damaged facilities due to storm and flood in rural areas, the items of damaged facilities depending on the types of storm and flood damages, and risk factors were suggested. Based on this result, in order to generalize the results of follow-up researches, it is thought that disaster recovery planning and establishing the system of remodeling items necessary for maintenance work would be possible by analyzing damage investigation items recorded in additional researches on rural areas, researches on natural disasters, and recovery plan instructions and by conducting on-site investigation on the damaged villages from storm and flood in rural areas.

A Study on the Analysis of the Walking Environment in the Residential Area for the Elderly in Busan Using Spatial Analysis (공간 분석 기법을 적용한 부산 노인 주거지의 보행환경 분석에 대한 연구)

  • Whiho LEE;Jihyun KIM
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.4
    • /
    • pp.251-265
    • /
    • 2023
  • The purpose of this study is to deduce key indicators in evaluating the pedestrian environment for the elderly in Busan, which has entered an aging society, and to propose policy improvement measures. The key indicators were selected based on prior research and surveys, and the effectiveness of those indicators were measured through evaluations conducted on three places which have the highest proportion of the elderly population in Busan. The summaries of analysis are as follow. First, the three places are hillslide residential areas, and areas of activity that the elderly have were very narrow due to the restrictions on their movement caused by slope. Second, the areas were filled with a number of illegally parked vehicles. And the degree of segregation of pedestrian and vehicle and the level of safety were very low. Third, the streets with steep slopes of the target site force the elderly to move vertically, and for this reason, the elderly are expressing difficulties in outdoor activities. Fourth, it was found that the target site lacked a space for relaxation during outdoor activities. The poor walking environment not only limit the essential and social activities of the elderly, but also adversely affects the health and quality of life of the elderly. In order to maintain the health of the elderly and improve the quality of life, actions should be taken to improve the walking factors that affect the movement and external activities of the elderly.

Collapse Modes of Steel Ordinary Concentrically Braced Frames According to Unbalanced Forces (불균형력에 따른 철골보통중심가새골조의 붕괴모드)

  • Park, Jin-Young;Kim, Seo-Yeon;Hong, Suk-Jae;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.249-257
    • /
    • 2015
  • The KBC2009 first introduces the requirements about vertical unbalanced forces into the design for steel ordinary concentrically braced frames(steel OCBFs), which forces them to easily meet the target seismic performance, called as the life safety performance objective under design based earthquakes(DBEs) pursuing in the KBC2009. However, there is little information on the effects of vertical unbalanced forces to the collapse prevention performance objective under maximum considered earthquakes(MCEs) which is another target seismic performance level implicitly prescribed in ASCE 7-10. It is valuable that the collapse capacities of steel OCBFs designed according to the KBC2009 are investigated. In this paper, the collapse modes of inverted V shaped steel OCBFs excited by MCEs are investigated. The prototype buildings of 5 story steel OCBFs are designed with different site conditions and three types of unbalanced forces are considered in the design stages. The prototype buildings are evaluated their seismic performances and collapse modes by nonlinear static analyses and nonlinear dynamic analyses. Analysis results show that the unbalanced forces significantly affect the seismic performance of the prototype buildings and proper considerations of unbalanced forces are required to achieve the desirable collapse mode and the collapse prevention performance objective.

Selecting Aquifer Artificial Recharge Methods Based on Characteristics of the Target Aquifer (주입대상 대수층의 특성을 고려한 인공함양 방법 선정 연구)

  • Lee, Yeoung-Dong;Shin, Dong-Min;Kim, Byeong-Jun;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.483-494
    • /
    • 2019
  • This study aimed to determine the extent of artificial aquifer recharge and to evaluate appropriate recharge techniques based on field investigations and comparative analysis of each recharge method. Characteristics of the aquifer determine the target aquifer and the recharge method for artificial groundwater recharge. Electrical conductivity surveys, drilling, permeability tests, and grain-size analysis indicate that the hydraulic conductivity of weathered soil and weathered rock is higher than that of upper unconsolidated soil. Pumping tests indicate that the groundwater level was stable at a depth of 12 m until 9 hours of pumping, but after that it dropped again, indicating anisotropic aquifer characteristics. Three types of artificial recharge method were reviewed, including recharge wells, ditches, and ponds, and a combination of two methods is proposed: a recharge well system directly injecting into weathered soil and rock sections with good permeability, and an injection ditch that can increase the recharge effect by line-type injection in the upstream area. The extent of groundwater recharge by the selected methods will be evaluated through on-site tests and if their applicability is verified, they will contribute to securing water in areas of water shortage.