• Title/Summary/Keyword: Target detection

Search Result 1,869, Processing Time 0.036 seconds

Effects of stimulus similarity on P300 amplitude in P300-based concealed information test (P300-기반 숨긴정보검사에서 자극유사성이 P300의 진폭에 미치는 영향)

  • Eom, Jin-Sup;Han, Yu-Hwa;Sohn, Jin-Hun;Park, Kwang-Bai
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.541-550
    • /
    • 2010
  • The present study examined whether the physical similarity of test stimuli affects P300 amplitude and detection accuracy for the P300-based concealed information test (P300 CIT). As the participant pretended suffering from memory impairment by an accident, own name was used as a concealed information to be probed by the P300 CIT in which the participant discriminated between a target and other (probe, irrelevant) stimuli. One group of participants was tested in the easy task condition with low physical similarity among stimuli, the other group was tested in the difficult task condition with high physical similarity among stimuli. Using the base-to-peak P300 amplitude, the interaction effect of task difficulty and stimulus type was significant at $\alpha$=.1 level (p=.052). In the easy task condition the difference of P300 amplitude between the probe and the irrelevant stimuli was significant, while in the difficult task condition the difference was not significant. Using peak-to-peak P300 amplitude, on the other hand, the interaction effect of task difficulty and stimulus type was not significant with significant differences of P300 amplitude between the probe and the irrelevant stimuli in both task difficulty conditions. The difference of detection accuracy between task conditions was not significant with both measures of P300 amplitude although the difference was much smaller when peak-to-peak P300 amplitude was used. The results suggest that the efficiency of P300 CIT would not decrease even when the perceptual similarity among test stimuli is high.

  • PDF

Comparison of PCR-Line Probe and PCR-SSCP Methods for the Detection of Rifampicin Resistant Mycobacterium Tuberculosis (Rifampicin 내성 결핵균의 검출에 있어서 PCR-line Probe법과 PCR-SSCP법의 비교)

  • Kim, Ho-Joong;Suh, Gee-Young;Chung, Man-Pyo;Kim, Jong-Won;Shim, Tae-Sun;Choi, Dong-Chull;Kwon, O-Jung;Rhee, Chong-H;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.714-722
    • /
    • 1998
  • Background: Rifampicin (RFP) is a key component of the antituberculous short-course chemotherapy and the RFP resistance is a marker of multi-drug resistant (MDR) tuberculosis. RPoB gene encodes the $\beta$-subunit of RNA polymerase of M. tuberculosis which is the target of RFP. And the mutations of rpoB gene have been found in about 96% of rifampicin resistant clinical isolates of M. tuberculosis. So in order to find a rapid and clinically useful diagnostic method in identifying the RFP resistance, we compared the PCR -line probe method with PCR-SSCP for the detection of the rpoB gene mutation in cultured M. tuberculosis. Methods: 45 clinical isolates were collected from patients who visited Sung Kyun Kwan University Hospital. The RFP susceptibility test was referred to the referral laboratory of the Korean Tuberculosis Institute. 33 were rifampicin resistant and 12 were rifampicin susceptible. The susceptibility results were compared with the results of the PCR-BSCP and PCR-line probe method. Results: We could find rpoB mutations in 27/33(81.8%) RFP-resistant strains by PCR-line probe method, and in 23/33 (69.7%) by PCR-SSCP and there was no significant difference between two methods. There was no mutation in rifampicinn susceptible strains by both methods. Conclusion: PCR-line probe method would be a rapid, sensitive and specific method for the detection of rifampicin resistant Mycobacterium tuberculosis.

  • PDF

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

Feasibility of Granular Activated Charcoal as a Detector in Fluorescent Tracer Tests (입상 활성탄을 이용한 형광물질 추적자시험 적용성 연구)

  • Lee, Jin-Yong;Hwang, Hyoun-Tae;Yi, Myeong-Jae;Kim, Yong-Cheol;Yum, Byoung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.4
    • /
    • pp.86-93
    • /
    • 2007
  • In recent tests using tracer have been frequently conducted by fluorescent tracers. In this study, granular activated charcoal (GAC) as a detector for the fluorescent tracers (rhodamine WT and uranine) was investigated through laboratory and field tests. In the laboratory tests, tracer concentrations of rhodamine WT and uranine determined by the GAC were slightly different from those of standard solutions but they were excellent in linearity. Results show that GAC is excellent as tracer detector when concentration of the fluorescent tracers is greater than 10 & micro; g/L whileas no obvious differences in mixed solutions of the two tracers due to interferences. Compared to conventional methods of water sampling, field results shows a high potential of GAC as a tracer in the field. Our results also show that wet analysis is better for the lower concentrations of tracers whileas dry analysis is good for high concentrations of tracers. This study demonstrates that fluorescent tracer detection using the GAC is very useful and economical for a hydraulic connection between target areas and very longer period of the tracer test.

Assessment of Environmental Pollution in Korean Stream Sediments by Chemical Analyses and Insect Immune Biomarkers

  • Ryoo, Keon-Sang;Byun, Sang-Hyuk;Hong, Yong-Pyo;Cho, Ki-Jong;Bae, Yeon-Jae;Kim, Yong-Gyun
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.4
    • /
    • pp.330-342
    • /
    • 2008
  • A comprehensive quality survey for PCDDs/PCDFs and coplanar PCBs as well as heavy metals (Cu, Zn, Cd and Pb) in sediments has been investigated in August 2006, Korea. Monitoring was undertaken at five streams representing different surrounding environments throughout Juwang and Gapyeong streams (reference sites), Jungrang stream (dense population site), Ansan stream (mixed small population and industrial site), and Siheung stream (heavy industrial site). The levels of heavy metal in samples were found to be significantly higher in sediment from Siheung stream compared to those of other stream sites. The heavy metal concentrations (dry weight basis) in sediment from Siheung stream were as follows; Cd (3.7 ${\mu}g$/g), Pb (1,295 ${\mu}g$/g), Cu (713.4 ${\mu}g$/g) and Zn (358.1 ${\mu}g$/g). Among 12 coplanar PCBs and 17 PCDDs/PCDFs selected as target compounds in this study, PCB (IUPAC no. 118) and OCDD were the most abundant congeners found in all sediment samples, followed by 1,2,3,4,6,7,8-HpCDD, OCDF and 1,2,3,4,6,7,8HpCDF as well as PCB (IUPAC no. 105). These results were shown to be in the same trend as the sediment samples of other countries. The levels of PCDDs/PCDFs/coplanar PCBs in sediment samples were expressed as concentrations and WHO- TEQ values. The PCDDs/PCDFs/coplanar PCBs concentrations and their WHO-TEQ values in sediment from Siheung stream were remarkably high. The levels detected were 788.16 pg/g and 36.080 pg WHO-TEQ/g dry weight for PCDDs/ PCDFs and 314 pg/g and 0.4189 pg WHO-TEQ/g dry weight for coplanar PCBs, respectively, beyond the safety level of sediment value 20 pg WHO-TEQ/g. Sediment samples of the five streams were also monitored by sensitive biomarkers using insect immune responses: hemocyte-spreading behavior and immune-associated enzyme activities of phospholipase A$_2$ (PLA$_2$) and phenoloxidase. Organic extracts of Siheung and Jungrang sediments significantly interfered with the hemocytespreading behavior, whereas those of Ansan, Gapyeong, and Juwang did not. These organic extracts did not inhibit the PLA$_2$ and phenoloxidase activities. However, phenoloxidase was highly susceptible to exposure to aqueous extracts in all site sediments. In comparison, PLA$_2$ activities of the hemocytes were significantly inhibited only by aqueous extracts of Siheung, Jungrang, and Gapyeong sediments, but not by those of Ansan and Juwang. Despite some disparity between bioand chemical monitoring results, the biomarkers can be recommended as a device warning the contamination of biohazard environmental chemicals because of a fast and inexpensive detection method.

Study on the Method to Improve a Maritime Safety by Analysing the Distribution Characteristics of the Ships on Marine Firing Range (해상사격장 선박분포 특성 분석을 통한 해상안전 개선방안에 대한 연구)

  • Baek, Sang Hwa;Lee, Ah Yoon;Park, Ho Jun;Lee, Woo Sung;Choi, Kye Soog
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.79-85
    • /
    • 2020
  • Ahn-heung Proving Ground(APG) of Agency for Defense Development(ADD) is the only weapon test site which has been performing firing tests for many kinds of missile, artillery and ammunition. APG has been performing the firing tests of so many times every year. The tests related to missiles, artillery and ammunitions cover 80% among the quantity of annual test events. The target area of many kinds of missile, artillery and ammunition is on the sea. Therefore, APG has its marine firing ranges which were approved by the ministry of Defense. Both weapons and ships can run into each other on the sea. APG has to monitor and detect the positions of the ships in the specific dangerous zone on the sea. The positions of the ships are detected by Scanter 2001 radar and GPS100 detection radar. Evading the time period when the ships appear very often on the sea may be a good solution to keep the maritime safety. And evading the place where the ships appear very often on the sea may be a good solution as well. This paper is to analyze the ships' distribution characteristics of marine firing range, which are to raise the efficiency of many kinds firing tests which have been performed in APG of ADD. Ship distribution data from February 2014 to December 2016 were used in this paper. Ship distribution was analyzed with monthly data, seasonal data and etc. The number of the ships in approved sea area is higher in the morning than in the afternoon, and in fall than other seasons, and from August to November, and below 0.5 m in the hight of wave. Using the these conditions, we can raise the test efficiency of many kinds firing tests and guarantee maritime safety. The number of the ships in approved sea area is entirely unrelated to visibility of the sea. The time period when the number of the ships are high on the sea is morning. The season when the number of the ships are comparatively high on the sea is fall. APG of ADD could raise the efficiency of the firing tests and improve the maritime safety, using the analysis results of the characteristics on the ship distribution.

Study of Bacteria Associated with Dental Caries Using a 3 Tone Disclosing Agent (세가지 색상차이를 보이는 착색제를 이용한 치아 우식 관련 균에 관한 연구)

  • Lee, Jeongeun;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.32-40
    • /
    • 2018
  • The aim of this study was to determine the efficacy of a 3 tone plaque disclosing gel in assessing the risk of caries related to the population of Streptococcus mutans, Streptococcus sobrinus, and Lactobacillus spp. quantified using a quantitative real-time polymerase chain reaction (qRT-PCR). 15 healthy children of ages 9 - 12 years were randomly examined. The 3 tone plaque disclosing gel was applied on teeth surfaces, which changed the color to pink or red, blue or purple and light blue. Plaque was divided into 3 groups based on staining. Genomic DNA from each sample was subjected to a qRT-PCR assay for quantitative detection of target bacteria. The Kruskal-Wallis test was conducted for correlation between the color of plaque and the number of bacterial species. The levels of S. mutans, S. sobrinus, and Lactobacillus spp. were significantly different in the plaque samples of the 3 groups (p < 0.05). The proportion of S. sobrinus to S. mutans showed correlation to the color of plaque. The different color-dyed plaque was related to the number of acidogenic bacteria. The 3 tone plaque disclosing gel could be used as one of the indicators to assess the clinical risk of caries associated with the population of S. mutans, S. sobrinus, and Lactobacillus spp.

Simultaneous determination of illegal galactagogue adulterants in supplement diets by LC-MS/MS

  • Lee, Ji Hyun;Cho, So-Hyun;Park, Han Na;Park, Hyoung Joon;Kim, Nam Sook;Park, Sung Kwan;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.171-178
    • /
    • 2018
  • Recently, for successful lactation, many breastfeeding mothers seek various products, including herbal medicine, dietary supplements, and prescribed medicines, to improve milk production. As demand for galactogogues grows, it is highly possible that pharmaceutical galactogogues may be adulterated with illegal products to maximize their efficacy. For continuous control and supervision of illegal products, we developed and validated a simple and sensitive LC-MS/MS method capable of simultaneously determining five galactogogues. Chromatographic separation was conducted using an Agilent Poroshell $120SB-C_{18}$ column with a mobile phase consisting of 20 mM ammonium formate (pH 5.4) and 100 % acetonitrile. The total run time was 13 min per analyte. The proposed method was performed according to the guidelines of the International Conference of Harmonization and it produced reliable results. This method showed high sensitivity and specificity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 0.01-0.82 ng/mL and 0.02-2.45 ng/mL, respectively, for the solid- and liquid-type samples. Specificity was evaluated by analyzing matrix-blank samples spiked with the target compounds at LOQ levels, which provided a good separation of all peaks without interference. Additionally, the repeatability and intermediate precision were typically <15 %, whereas the recovery was 80-120 % of the values obtained using blank samples. Thus, we concluded that this method could be used for the identification and quantification of galactogogues in food or herbal products.

Detection of Tuberculous Lesion by Immunoscintigraphy Using Radiolabeled Specific Polyclonal Antibody Against M. bovis BCG in Rabbit: A Preliminary Result (가토에서 방사면역 신티그래피를 이용한 결핵병변의 진단 : 예비보고)

  • Lee, Jong-Doo;Shin, Kyoo-Ho;Cho, Sang-Nae;Shin, Jeon-Soo;Lee, Min-Geol;Yang, Woo-Ick;Park, Chang-Yoon;Yoo, Hyung-Sik;Lee, Jong-Tae;Awh, Ok-Doo;Park, Kyung-Bae;Kim, Jae-Rok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.245-251
    • /
    • 1991
  • 결핵성 병변의 단순 x-ray 촬영이나 CT, MRI 소견은 매우 다양하며, 결핵과 전이암 혹은 원발성 암과 감별이 어려운 경우가 있어 결핵으로 확진하기 위하여서 조직 생검이나 수술 등 침습적인 진단 방법을 이용하여야 하였다. 그러므로 이러한 결핵 병변을 비 침습적인 방법으로 정확히 감별할 수 있는 방법을 연구하던 바, 결핵균에 대한 항체를 동위원소에 부착시켜 신티그래피로 진단할 수 있는지의 가능성을 동물실험을 통하여 알아보고자 하였다. 15마리의 가토에서 M.tuberculosis H37Rv를 슬관절에 주입시켜 결핵병변을 유발시키고, 대조군으로 2마리의 가토의 고환에 T.pallidum을 주입하여 매독병변을 유발시킨 후 M.bovis BCG에 대한 특이항체 (specific polyclonal antibody)와 정상 가토의 immunoglobulin을 I-131에 부착시켜 각각의 가토에 주입하여 preset time 10분간 감마카메라로 주사한 결과 다음과 같은 결과를 얻었다. (1) 8마리의 결핵에 감염된 가토에 M.bovis BCG에 대한 $F(ab')_2$를 1 mCi의 I -131 labeling 시킨후 주사한 결과 모두에서 주사후 2시간 부터 72시간까지 병소가 hot uptake으로 보였으며 주사후 24 시간에 가장 높은 target/background ratio를 보였다. (2) 2마리의 매독에 감염된 가토에서 anti-BCG $F(ab')_2$를 주사한 결과 2시간에서는 병소에 hot activity를 보였으나 24시간부터 급격히 activity가 감소하였다. (3) $F(ab')_2$ 대신에 intact antibody를 결핵에 감염된 가토에 투여한 결과 specific polyclonal antibody나 정상가토의 immunoglobulin 모두 결핵병소에 96시간까지 hot uptake를 보였다. 그러므로 결핵균에 대한 specific antibody fragment를 이용하면 방사면역 신티그램으로 진단이 가능하리라 사료되었고, intact antibody를 사용할 경우 sensitivity는 높으나 specificity는 적을 것으로 사료되었다.

  • PDF

Ultrasensitive serum thyroglobulin the usefulness of evaluation (Ultrasensitive serum thyroglobulin의 유용성 평가)

  • Lee, Sun Ho;Cho, Eun Bit;Shin, Young Kyun;Lee, Young Ji;Yoo, Seun Hee;Kim, Nyun Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.102-107
    • /
    • 2015
  • Purpose Serum Thyroglobulin measurement is a major tool for the follow-up of differentiated thyroid cancer (DTC) patients. Thyroglobulin is Normal thyroid tissue, or thyroid cancer tissue produced only. Thyroid hormone to a halt without Tg differentiation of thyroid cancer recurrence just by measuring how to decide whether there was increasing expectations if I can do it instead. Therefore, in excellent sensitivity Tg new inspection of the functional sensitivity by measuring the looked to evaluate the usefulness of reagents. Thyroidectomy is measuring the numbers Tg (total thyroidectomy) remaining thyroid ablation and radioactive iodine (radioactive iodine remnant ablation, RRA) DTC in patients being diagnosed with or help predict the remaining early detection of thyroid cancer recurrence. Materials and Methods Agent that I'm currently using Tg of the measurements of low clinical specimen for a second drainage of the three (0.08 0.17, 0.98, ng/mL) within the scope of the dilute magnification (2, 4, 8, 16, 32 times) by dilute Intraassy (n=10) and Interassay (n=10) out in no time. Concentration value according to the coefficient of variation and the mean and standard deviation of each measurement (Coefficient of variation, CV) the absolute value of the measured values that corresponds to 20 percent target a coefficient of variation of CV Find the value of the concentration of the functional sensitivity measurement did. Also, analytical sensitivity with recovery rates, Dilution test inspections, and interrelationship, compared. Results Sensitivity is an excellent analytical sensitivity within the prosecutor kit Tg 0.006 ng/mL, and core analytical sensitivity, conducted by the 0.006 ng/mL to same conclusion. Be rather high to 142 percent recovery rate was 60 to measurement and functional sensitivity, 0.01766 ng/mL(Intraassay n=10) was measured at. CBC is relatively good correlation as ($R^2=0.949$) the correlation. Conclusion Recently ultrasensitive thyroglobulin this clinically important indicators of the previous kit and demands are lower than sensitivity to the measurement results. Therefore, ultrasensitive thyroglobulin test is correlated that there would be useful in value in nuclear medicine the thyroid gland.

  • PDF